11 resultados para Ablation Techniques

em BORIS: Bern Open Repository and Information System - Berna - Suiça


Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE OF REVIEW This article summarizes current understanding of the arrhythmia substrate and effect of catheter ablation for infarct-related ventricular tachycardia, focusing on recent findings. RECENT FINDINGS Clinical studies support the use of catheter ablation earlier in the course of ischemic disease with moderate success in reducing arrhythmia recurrence and shocks from implantable defibrillators, although mortality remains unchanged. Ablation can be lifesaving for patients presenting with electrical storm. Advanced mapping systems with image integration facilitate identification of potential substrate, and several different approaches to manage hemodynamically unstable ventricular tachycardia have emerged. Novel ablation techniques that allow deeper lesion formation are in development. SUMMARY Catheter ablation is an important therapeutic option for preventing or reducing episodes of ventricular tachycardia in patients with ischemic cardiomyopathy. Present technologies allow successful ablation in the majority of patients, even when the arrhythmia is hemodynamically unstable. Failure of the procedure is often because of anatomic challenges that will hopefully be addressed with technological progress.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Ventricular tachycardia (VT) refractory to antiarrhythmic drugs and standard percutaneous catheter ablation techniques portends a poor prognosis. We characterized the reasons for ablation failure and describe alternative interventional procedures in this high-risk group. METHODS AND RESULTS Sixty-seven patients with VT refractory to 4±2 antiarrhythmic drugs and 2±1 previous endocardial/epicardial catheter ablation attempts underwent transcoronary ethanol ablation, surgical epicardial window (Epi-window), or surgical cryoablation (OR-Cryo; age, 62±11 years; VT storm in 52%). Failure of endo/epicardial ablation attempts was because of VT of intramural origin (35 patients), nonendocardial origin with prohibitive epicardial access because of pericardial adhesions (16), and anatomic barriers to ablation (8). In 8 patients, VT was of nonendocardial origin with a coexisting condition also requiring cardiac surgery. Transcoronary ethanol ablation alone was attempted in 37 patients, OR-Cryo alone in 21 patients, and a combination of transcoronary ethanol ablation and OR-Cryo (5 patients), or transcoronary ethanol ablation and Epi-window (4 patients), in the remainder. Overall, alternative interventional procedures abolished ≥1 inducible VT and terminated storm in 69% and 74% of patients, respectively, although 25% of patients had at least 1 complication. By 6 months post procedures, there was a significant reduction in defibrillator shocks (from a median of 8 per month to 1; P<0.001) and antiarrhythmic drug requirement although 55% of patients had at least 1 VT recurrence, and mortality was 17%. CONCLUSIONS A collaborative strategy of alternative interventional procedures offers the possibility of achieving arrhythmia control in high-risk patients with VT that is otherwise uncontrollable with antiarrhythmic drugs and standard percutaneous catheter ablation techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: The experience of using radiofrequency ablation (RFA) for the treatment of arrhythmias in children and adolescents is still limited. This study aimed to review the most recent results of RF ablation in children and adolescents in a highly experienced centre with access to both conventional techniques and non-fluoroscopic electroanatomic mapping (CARTO). METHODS AND RESULTS: A total of 154 consecutive patients younger than 19 years treated with RFA during the period 2000-04 were included. Numbers (%) or median (quartiles) are reported. Age was 15 (12-17) years, 70 (45%) were males. Five patients (3%) had congenital heart disease. RFA was successful in 147/154 patients (95%). Arrhythmia recurrence occurred in 11 patients (7%). Procedure time was 55 (35-90) min and fluoroscopy time was 8.8 (4-19) min. Number of RF applications was 4 (2-10) and number of RF applications >20 s was 2 (1-7). One patient (0.7%) had complicating high-grade atrioventricular block. CARTO was used in 18 RF ablation procedures (11%) performed in 15 patients. CONCLUSION: RF ablation can be undertaken in children and adolescents with a high success rate, few recurrences and complications, very short procedure times, and acceptable fluoroscopy times. Non-fluoroscopic electroanatomic mapping is helpful in selected patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to analyze trigger activity in the long-term follow-up after left atrial (LA) linear ablation. BACKGROUND Interventional strategies for curative treatment of atrial fibrillation (AF) are targeted at the triggers and/or the maintaining substrate. After substrate modification using nonisolating linear lesions, the activity of triggers is unknown. METHODS With the LA linear lesion concept, 129 patients were treated using intraoperative ablation with minimal invasive surgical techniques. Contiguous radiofrequency energy-induced lesion lines involving the mitral annulus and the orifices of the pulmonary veins without isolation were placed under direct vision. RESULTS After a mean follow-up of 3.6 +/- 0.4 years, atrial ectopy, atrial runs, and reoccurrence of AF episodes were analyzed by digital 7-day electrocardiograms in 30 patients. Atrial ectopy was present in all patients. Atrial runs were present in 25 of 30 patients (83%), with a median number of 9 runs per patient/week (range 1 to 321) and a median duration of 1.2 s/run (range 0.7 to 25), without a significant difference in atrial ectopy and atrial runs between patients with former paroxysmal (n = 17) or persistent AF (n = 13). Overall, 87% of all patients were completely free from AF without antiarrhythmic drugs. CONCLUSIONS A detailed rhythm analysis late after specific LA linear lesion ablation shows that trigger activity remains relatively frequent but short and does not induce AF episodes in most patients. The long-term success rate of this concept is high in patients with paroxysmal or persistent AF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Intraoperative radiofrequency (RF) ablation is an effective treatment of atrial fibrillation (AF). However, secondary arrhythmias late after ablation may complicate the patient's course. We report on the incidence, mechanisms, and treatment of gap-related atrial flutter and other secondary arrhythmias during long-term follow-up. METHODS AND RESULTS In 129 patients who underwent intraoperative RF ablation with placement of left atrial linear lesions using minimally invasive surgical techniques, secondary arrhythmias were analyzed during long-term follow-up (20 +/- 6 months). Transient atrial arrhythmias during the first 3 postoperative months were excluded. In 8 (6.2%) of 129 patients, sustained stable secondary arrhythmias were documented. Left atrial, gap-related atrial flutter was observed in 4 patients (3.1%). The flutter was treated by percutaneous RF ablation in 3 patients (2.3%) and with drugs in 1 patient (0.8%). In 2 patients (1.6%), right atrial isthmus-dependent atrial flutter occurred and was treated successfully by percutaneous RF ablation. In 2 patients (1.6%), ectopic right atrial tachycardias occurred and were treated with percutaneous RF ablation. CONCLUSION Late after intraoperative RF ablation of atrial fibrillation, three types of stable secondary arrhythmias were observed in 6% of patients: left atrial gap-related atrial flutter, right atrial isthmus-dependent atrial flutter, and ectopic atrial tachycardia. Gaps after intraoperative RF ablation due to noncontinuous or nontransmural linear lesions may lead to stable left atrial macroreentrant tachycardias, requiring new interventional therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to evaluate irrigated-tip catheter for ablation of intraatrial reentrant tachycardias late after surgical repair of congenital heart disease. BACKGROUND In congenital heart disease patients, the right atrium can be markedly enlarged with areas of low blood flow. Radiofrequency (RF) lesion creation may be hampered by insufficient electrode cooling at sites with low blood flow. METHODS Thirty-six consecutive patients with intraatrial reentrant tachycardia refractory to antiarrhythmic therapy from two centers were included in the study. Entrainment pacing and electroanatomic mapping (CARTO) were used to delineate reentrant circuits and critical isthmus sites. RF ablation was performed using an irrigated-tip catheter (Navistar Thermocool). RESULTS Fifty-two intraatrial reentrant tachycardia circuits were identified, and 48 were targeted with RF ablation. RF ablation was performed using a mean of 13 +/- 11 irrigated RF applications per tachycardia isthmus with a mean power of 36 +/- 8 W. In a historical control group of congenital heart disease patients managed with conventional catheter ablation, the number of lesions per isthmus was higher (23 +/- 11) and mean power was lower (27 +/- 14 W). Acute success was achieved in 45 intraatrial reentrant tachycardias (94% of targeted tachycardias and 87% of all tachycardias). After a mean follow-up of 17 +/- 7 months, 33 (92%) of 36 patients were free of recurrence. Five patients (14%) developed paroxysmal atrial fibrillation. CONCLUSIONS The combination of modern techniques including electroanatomic mapping and catheter irrigation allows safe and highly effective ablation of intraatrial reentrant tachycardia in patients with surgically repaired congenital heart disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electroanatomic mapping system Carto((R)) with its combination of anatomic and electrophysiologic information has substantially improved our understanding of arrhythmia mechanisms and substrates in patients with ventricular tachycardia (VT) and structural heart disease. Identification of the individual arrhythmogenic substrate and successful ablation guided by the combination of sinus rhythm voltage mapping and conventional electrophysiologic techniques like pace and activation/entrainment mapping are best described for patients with recurrent VT in remote myocardial infarction. In about 75-90% of the patients, the target VT can be ablated with acute success and the patients remain free of any VT recurrence in up to 75%. First results of electroanatomically guided ablation in patients with arrhythmogenic right ventricular dysplasia are promising. Data on ablation of VT in other structural heart diseases are very limited, since the arrhythmogenic substrate is very diffuse, e. g., in dilated cardiomyopathy, or there are only small patient numbers, e. g., for cardiac sarcoidosis or monomorphic VT after repair of congenital heart disease. In this article, the current status of electroanatomically guided endocardial mapping and ablation of VT in patients with structural heart disease is described.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Leaves are arranged according to regular patterns, a phenomenon referred to as phyllotaxis. Important determinants of phyllotaxis are the divergence angle between successive leaves, and the size of the leaves relative to the shoot axis. Young leaf primordia are thought to provide positional information to the meristem, thereby influencing the positioning of new primordia and hence the divergence angle. On the contrary, the meristem signals to the primordia to establish their dorsoventral polarity, which is a prerequisite for the formation of a leaf blade. These concepts originate from classical microsurgical studies carried out between the 1920s and the 1970s. Even though these techniques have been abandoned in favor of genetic analysis, the resulting insights remain a cornerstone of plant developmental biology. Here, we employ new microsurgical techniques to reassess and extend the classical studies on phyllotaxis and leaf polarity. Previous experiments have indicated that the isolation of an incipient primordium by a tangential incision caused a change of divergence angle between the two subsequent primordia, indicating that pre-existing primordia influence further phyllotaxis. Here.. we repeat these experiments and compare them with the results of laser ablation of incipient primordia. Furthermore. we explore to what extent the different pre-existing primordia influence the size and position of new organs. and hence phyllotaxis. We propose that the two youngest primordia (P-1 and P-2) are sufficient for the approximate positioning of the incipient primordium (I-1), and therefore for the perpetuation of the generative spiral, whereas the direct contact neighbours of I-1 (P-2 and P-3) control its delimitation and hence its exact size and position. Finally. we report L I specific cell ablation experiments suggesting that the meristem L-1 layer is essential for the dorsoventral patterning of leaf primordia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laser ablation/ionisation mass spectrometry with a vertical resolution at a nanometre scale was applied for the quantitative characterisation of the chemical composition of additive-assisted Cu electroplated deposits used in the microchip industry. The detailed chemical analysis complements information gathered by optical techniques and allows new insights into the metal deposition process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Detection of extraterrestrial life is an ongoing goal in space exploration, and there is a need for advanced instruments and methods for the detection of signatures of life based on chemical and isotopic composition. Here, we present the first investigation of chemical composition of putative microfossils in natural samples using a miniature laser ablation/ionization time-of-flight mass spectrometer (LMS). The studies were conducted with high lateral (similar to 15 mu m) and vertical (similar to 20-200 nm) resolution. The primary aim of the study was to investigate the instrument performance on micrometer-sized samples both in terms of isotope abundance and element composition. The following objectives had to be achieved: (1) Consider the detection and calculation of single stable isotope ratios in natural rock samples with techniques compatible with their employment of space instrumentation for biomarker detection in future planetary missions. (2) Achieve a highly accurate chemical compositional map of rock samples with embedded structures at the micrometer scale in which the rock matrix is easily distinguished from the micrometer structures. Our results indicate that chemical mapping of strongly heterogeneous rock samples can be obtained with a high accuracy, whereas the requirements for isotope ratios need to be improved to reach sufficiently large signal-to-noise ratio (SNR). Key Words: Biogenicity-Biomarkers-Biosignatures-Filaments-Fossilization. Astrobiology 15, 669-682.