45 resultados para 249903 Instruments and Techniques
em BORIS: Bern Open Repository and Information System - Berna - Suiça
Resumo:
Mechanical thrombectomy provides higher recanalization rates than intravenous or intra-arterial thrombolysis. Finally this has been shown to translate into improved clinical outcome in six multicentric randomized controlled trials. However, within cohorts the clinical outcomes may vary, depending on the endovascular techniques applied. Systems aiming mainly for thrombus fragmentation and lacking a protection against distal embolization have shown disappointing results when compared to recent stent-retriever studies or even to historical data on local arterial fibrinolysis. Procedure-related embolic events are usually graded as adverse events in interventional neuroradiology. In stroke, however, the clinical consequences of secondary emboli have so far mostly been neglected and attributed to progression of the stroke itself. We summarize the evolution of instruments and techniques for endovascular, image-guided, microneurosurgical recanalization in acute stroke, and discuss how to avoid procedure-related embolic complications.
Resumo:
Despite rapid advances in the development of materials and techniques for endovascular intracranial aneurysm treatment, occlusion of large broad-neck aneurysms remains a challenge. Animal models featuring complex aneurysm architecture are needed to test endovascular innovations and train interventionalists.
Resumo:
The design of a high-density neural recording system targeting epilepsy monitoring is presented. Circuit challenges and techniques are discussed to optimize the amplifier topology and the included OTA. A new platform supporting active recording devices targeting wireless and high-resolution focus localization in epilepsy diagnosis is also proposed. The post-layout simulation results of an amplifier dedicated to this application are presented. The amplifier is designed in a UMC 0.18µm CMOS technology, has an NEF of 2.19 and occupies a silicon area of 0.038 mm(2), while consuming 5.8 µW from a 1.8-V supply.
Resumo:
Randomised controlled trials (RCTs) of psychotherapeutic interventions assume that specific techniques are used in treatments, which are responsible for changes in the client's symptoms. This assumption also holds true for meta-analyses, where evidence for specific interventions and techniques is compiled. However, it has also been argued that different treatments share important techniques and that an upcoming consensus about useful treatment strategies is leading to a greater integration of treatments. This makes assumptions about the effectiveness of specific interventions ingredients questionable if the shared (common) techniques are more often used in interventions than are the unique techniques. This study investigated the unique or shared techniques in RCTs of cognitive-behavioural therapy (CBT) and short-term psychodynamic psychotherapy (STPP). Psychotherapeutic techniques were coded from 42 masked treatment descriptions of RCTs in the field of depression (1979-2010). CBT techniques were often used in studies identified as either CBT or STPP. However, STPP techniques were only used in STPP-identified studies. Empirical clustering of treatment descriptions did not confirm the original distinction of CBT versus STPP, but instead showed substantial heterogeneity within both approaches. Extraction of psychotherapeutic techniques from the treatment descriptions is feasible and could be used as a content-based approach to classify treatments in systematic reviews and meta-analyses.
Resumo:
This work applies higher order auxiliary excitation techniques to two types of quadrupole mass spectrometers (QMSs): commercial systems and spaceborne instruments. The operational settings of a circular rod geometry commercial system and an engineering test-bed for a hyperbolic rod geometry spaceborne instrument were matched, with the relative performance of each sensor characterized with and without applied excitation using isotopic measurements of Kr+. Each instrument was operated at the limit of the test electronics to determine the effect of auxiliary excitation on extending instrument capabilities. For the circular rod sensor, with applied excitation, a doubling of the mass resolution at 1% of peak transmission resulted from the elimination of the low-mass side peak tail typical of such rod geometries. The mass peak stability and ion rejection efficiency were also increased by factors of 2 and 10, respectively, with voltage scan lines passing through the center of stability islands formed from auxiliary excitation. Auxiliary excitation also resulted in factors of 6 and 2 in peak stability and ion rejection efficiency, respectively, for the hyperbolic rod sensor. These results not only have significant implications for the use of circular rod quadrupoles with applied excitation as a suitable replacement for traditional hyperbolic rod sensors, but also for extending the capabilities of existing hyperbolic rod QMSs for the next generation of spaceborne instruments and low-mass commercial systems.
Resumo:
BACKGROUND Neuronavigation is an essential tool in cranial neurosurgery. Despite continuing improvements in the technologies used for neuronavigation, certain events can lead to unacceptable mismatches. To provide the best possible outcome for the patients, surgeons need to do everything possible to reduce mismatches. METHODS AND RESULTS Some simple techniques can greatly improve neuronavigation accuracy and patient safety. We describe two simple methods that were developed or refined in the Department of Neurosurgery at Inselspital, Bern, Switzerland: the transdermal navigation landmark and use of bone screws for co-registration. CONCLUSIONS Both techniques are easy to use, do not require expensive additional instruments, and are helpful in procedures involving neuronavigation.
Resumo:
Root canal treatment is a frequently performed dental procedure and is carried out on teeth in which irreversible pulpitis has led to necrosis of the dental pulp. Removal of the necrotic tissue remnants and cleaning and shaping of the root canal are important phases of root canal treatment. Treatment options include the use of hand and rotary instruments and methods using ultrasonic or sonic equipment. OBJECTIVES: The objectives of this systematic review of randomized controlled trials were to determine the relative clinical effectiveness of hand instrumentation versus ultrasonic instrumentation alone or in conjunction with hand instrumentation for orthograde root canal treatment of permanent teeth. MATERIAL AND METHODS: The search strategy retrieved 226 references from the Cochrane Oral Health Group Trials Register (7), the Cochrane Central Register of Controlled Trials (CENTRAL) (12), MEDLINE (192), EMBASE (8) and LILACS (7). No language restriction was applied. The last electronic search was conducted on December 13th, 2007. Screening of eligible studies was conducted in duplicate and independently. RESULTS: Results were to be expressed as fixed-effect or random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated including both clinical and methodological factors. No eligible randomized controlled trials were identified. CONCLUSIONS: This review illustrates the current lack of published or ongoing randomized controlled trials and the unavailability of high-level evidence based on clinically relevant outcomes referring to the effectiveness of ultrasonic instrumentation used alone or as an adjunct to hand instrumentation for orthograde root canal treatment. In the absence of reliable research-based evidence, clinicians should base their decisions on clinical experience, individual circumstances and in conjunction with patients' preferences where appropriate. Future randomized controlled trials might focus more closely on evaluating the effectiveness of combinations of these interventions with an emphasis on not only clinically relevant, but also patient-centered outcomes.
Resumo:
Major modifications in the design and techniques of total ankle replacement have challenged the perception that ankle arthrodesis is the treatment of choice for end-stage ankle arthritis. High complication and revision rates have been reported after both procedures.
Resumo:
Case Description-A 9-year-old spayed female green iguana (Iguana iguana) was evaluated because of a distended coelom and weight loss. History included a single episode of egg binding and subsequent bilateral ovariosalpingectomy.;Clinical Findings-Physical examination revealed a mass within the coelomic cavity. Ultrasonography revealed a large, irregular mass with hypoechoic regions and coelomic effusion. Clinicopathologic derangements included heterophilia, monocytosis, lymphopenia, basophilia, hypocholesterolemia, hypoproteinemia, and hypercalcemia. Results of cytologic evaluation of the mass were suggestive of malignant epithelial neoplasia, but neoplastic cells were not found in the effusion. An ovarian tumor was suspected on the basis of clinical signs, clinicopathologic findings, and results of cytologic evaluation of the mass.;Treatment and Outcome-Surgical exploration revealed a large left ovary, a normal-appearing contralateral ovary, and a mass in the fat body, all of which were removed and submitted for histologic examination. The histologic diagnosis was granulosa cell tumor with metastasis to the fat body. The patient died 11 months after evaluation, and disseminated granulosa cell tumor was confirmed at necropsy; histologic examination at that time also identified systemic mastocytosis.;Clinical Relevance-Granulosa cell tumors are uncommon in reptiles, and this was the first granulosa cell tumor described antemortem cytologically, histologically, and ultrastructurally in an iguana. Findings in this iguana underscored concerns associated with incomplete oophorectomy of iguanas; cytologic and histopathologic findings were similar to those observed in other domestic animals. Oophorectomy should be considered as an alternative to standard ovariosalpingectomy to avoid potential complications in pet reptiles, and use of microsurgical instruments and vascular clips is advised. (J Am Vet Med Assoc 2011239:237-242)
Resumo:
Oncological liver surgery and interventions aim for removal of tumor tissue while preserving a sufficient amount of functional tissue to ensure organ regeneration. This requires detailed understanding of the patient-specific internal organ anatomy (blood vessel system, bile ducts, tumor location). The introduction of computer support in the surgical process enhances anatomical orientation through patient-specific 3D visualization and enables precise reproduction of planned surgical strategies though stereotactic navigation technology. This article provides clinical background information on indications and techniques for the treatment of liver tumors, reviews the technological contributions addressing the problem of organ motion during navigated surgery on a deforming organ, and finally presents an overview of the clinical experience in computer-assisted liver surgery and interventions. The review concludes that several clinically applicable solutions for computer aided liver surgery are available and small-scale clinical trials have been performed. Further developments will be required more accurate and faster handling of organ deformation and large clinical studies will be required for demonstrating the benefits of computer aided liver surgery.
Resumo:
Software systems need to continuously change to remain useful. Change appears in several forms and needs to be accommodated at different levels. We propose ChangeBoxes as a mechanism to encapsulate, manage, analyze and exploit changes to software systems. Our thesis is that only by making change explicit and manipulable can we enable the software developer to manage software change more effectively than is currently possible. Furthermore we argue that we need new insights into assessing the impact of changes and we need to provide new tools and techniques to manage them. We report on the results of some initial prototyping efforts, and we outline a series of research activities that we have started to explore the potential of ChangeBoxes.