119 resultados para Laparoscopic Donor Nephrectomy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate possible predictive factors for recurrence after laparoscopic segmental bowel resection for bowel endometriosis. DESIGN Cohort study. SETTING Academic tertiary referral center. METHODS 95 symptomatic women with bowel endometriosis who underwent laparoscopic segmental bowel resection at the Endometriosis clinic, University of Berne, between 2002 and 2012 were enrolled. Since 14 women were lost to follow-up, 81 formed the final cohort. Clinical and histological characteristics were examined as possible predictive factors for disease recurrence. MAIN OUTCOME MEASURES Recurrence, defined as a subsequent operation due to recurrent endometriosis-associated pain with a histologically confirmed endometriotic lesion. RESULTS Recurrence was observed in 13 (16%) patients. Variables that were significantly associated to recurrence by the Cox regression analysis were positive bowel resection margins (hazard ratio 6.5, 95% confidence interval 1.8-23.5, p = 0.005), age <31 years (hazard ratio 5.6, 95% confidence interval 1.7-18.6, p = 0.005) and body mass index ≥23 kg/m(2) (hazard ratio 11.0, 95% confidence interval 2.7-44.6, p = 0.001). CONCLUSIONS Positive bowel resection margins as well as age <31 years and body mass index ≥23 kg/m(2) appear to be independent predictors of disease recurrence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crystal structures of organosulfur donor 2-(5′,6′-dihydro[1,3]dithiolo[4,5-b][1,4]-dithiin-2′-ylidene)-6,7-di-hydro-5H-[1,3]dithiolo[4,5-b][1,4]dithiepine-6,6-dimethanol (D) and its conducting salt D2I3 are described. Conductivity properties of D2I3 are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The minimally invasive approach for hysterectomy with proven benefits and lower morbidity has become the gold standard, even in women with large uterine masses. Most women with a malignant condition present with abnormal vaginal bleeding and/or suspicious imaging such that few are diagnosed by final histopathology after surgery. However, if a malignancy is not diagnosed preoperatively, intraabdominal morcellation for uterus extraction has an increased risk for potential tumor spread and peritoneal metastases, especially in cases of unexpected leiomyosarcoma. We describe a simple method to wrap the uterus in a contained environment with a plastic bag through the posterior vaginal fornix prior to conventional coring morcellation for vaginal extraction in total laparoscopic hysterectomy. We further describe our experience with a risk stratification and treatment algorithm to implement this procedure in daily routine. A video and an illustrating sketch demonstrate the simplicity and safety of the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The impact of cardiopulmonary bypass in level III-IV tumor thrombectomy on surgical and oncologic outcomes is unknown. We determine the impact of cardiopulmonary bypass on overall and cancer specific survival, as well as surgical complication rates and immediate outcomes in patients undergoing nephrectomy and level III-IV tumor thrombectomy with or without cardiopulmonary bypass. MATERIALS AND METHODS We retrospectively analyzed 362 patients with renal cell cancer and with level III or IV tumor thrombus from 1992 to 2012 at 22 U.S. and European centers. Cox proportional hazards models were used to compare overall and cancer specific survival between patients with and without cardiopulmonary bypass. Perioperative mortality and complication rates were assessed using logistic regression analyses. RESULTS Median overall survival was 24.6 months in noncardiopulmonary bypass cases and 26.6 months in cardiopulmonary bypass cases. Overall survival and cancer specific survival did not differ significantly in both groups on univariate analysis or when adjusting for known risk factors. On multivariate analysis no significant differences were seen in hospital length of stay, Clavien 1-4 complication rate, intraoperative or 30-day mortality and cancer specific survival. Limitations include the retrospective nature of the study. CONCLUSIONS In our multi-institutional analysis the use of cardiopulmonary bypass did not significantly impact cancer specific survival or overall survival in patients undergoing nephrectomy and level III or IV tumor thrombectomy. Neither approach was independently associated with increased mortality on multivariate analysis. Greater surgical complications were not independently associated with the use of cardiopulmonary bypass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of expensive and bulky equipment which can hardly be integrated in a surgical scenario. METHODS In this work, we present a novel LRS-based IGS system for laparoscopic liver procedures. A triangulation process is formulated to compute the 3D coordinates of laser points by using the existing IGS system tracking devices. This allows the use of a compact and cost-effective LRS and therefore facilitates the integration into the laparoscopic setup. The 3D laser points are then reconstructed into a surface to register to the preoperative liver model using a multi-level registration process. RESULTS Experimental results show that the proposed system provides submillimeter scanning precision and accuracy comparable to those reported in the literature. Further quantitative analysis shows that the proposed system is able to achieve a patient-to-image registration accuracy, described as target registration error, of [Formula: see text]. CONCLUSIONS We believe that the presented approach will lead to a faster integration of LRS-based registration techniques in the surgical environment. Further studies will focus on optimizing scanning time and on the respiratory motion compensation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present cases of 2 pregnant patients with early-stage cervical cancer who have undergone indocyanine green (ICG) sentinel lymph node (SLN) mapping followed by laparoscopic SLN biopsy, pelvic lymphadenectomy, and cervical conization. Eight milliliters of ICG were injected in the 4 quadrants of the cervix after having obtained an adequate pneumoperitoneum and having inspected the abdominal cavity. SLNs were identified in both hemipelvises in both patients. In the final pathologic analysis, both SLNs and non-SLNs were negative for metastatic disease. No adverse events from ICG injection were recorded. ICG SLN mapping seems to be feasible in pregnant cervical cancer patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE (99)TC combined with blue-dye mapping is considered the best sentinel lymph node (SLN) mapping technique in cervical cancer. Indocyanine green (ICG) with near infrared fluorescence imaging has been introduced as a new methodology for SLN mapping. The aim of this study was to compare these two techniques in the laparoscopic treatment of cervical cancer. METHODS Medical records of patients undergoing laparoscopic SLN mapping for cervical cancer with either (99)Tc and patent blue dye (Group 1) or ICG (Group 2) from April 2008 until August 2012 were reviewed. Sensitivity, specificity, and overall and bilateral detection rates were calculated and compared. RESULTS Fifty-eight patients were included in the study-36 patients in Group 1 and 22 patients in Group 2. Median tumor diameter was 25 and 29 mm, and mean SLN count was 2.1 and 3.7, for Groups 1 and 2, respectively. Mean non-SLN (NSLN) count was 39 for both groups. SLNs were ninefold more likely to be affected by metastatic disease compared with NSLNs (p < 0.005). Sensitivity and specificity were both 100 %. Overall detection rates were 83 and 95.5 % (p = nonsignificant), and bilateral detection rates were 61 and 95.5 % (p < 0.005), for Groups 1 and 2, respectively. In 75 % of cases, SLNs were located along the external or internal iliac nodal basins. CONCLUSIONS ICG SLN mapping in cervical cancer provides high overall and bilateral detection rates that compare favorably with the current standard of care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The traditional surgical treatment for cervical insufficiency is vaginal placement of a cervical cerclage. However, in a small number of cases a vaginal approach is not possible. A transabdominal approach can become an option for these patients. Laparoscopic cervical cerclage is associated with good pregnancy outcomes but comes at the cost of a higher risk of serious surgical complications. The aim of the present study was to evaluate intraoperative and long-term pregnancy outcomes after laparoscopic cervical cerclage, performed either as an interval procedure or during early pregnancy, using a new device with a blunt grasper and a flexible tip. Methods: All women who underwent laparoscopic cervical cerclage for cervical insufficiency in our institution using the Goldfinger® device (Ethicon Endo Surgery, Somerville, NJ, USA) between January 2008 and March 2014 were included in the study. Data were collected from the patients' medical records and included complications during and after the above-described procedure. Results: Eighteen women were included in the study. Of these, six were pregnant at the time of laparoscopic cervical cerclage. Mean duration of surgery was 55 ± 10 minutes. No serious intraoperative or postoperative complications occurred. All patients were discharged at 2.6 ± 0.9 days after surgery. One pregnancy ended in a miscarriage at 12 weeks of gestation. All other pregnancies ended at term (> 37 weeks of gestation) with good perinatal and maternal outcomes. Summary: Performing a laparoscopic cervical cerclage using a blunt grasper device with a flexible tip does not increase intraoperative complications, particularly in early pregnancy. We believe that use of this device, which is characterized by increased maneuverability, could be an important option to avoid intraoperative complications if surgical access is limited due to the anatomical situation. However, because of the small sample size, further studies are needed to confirm our findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a video of an ultrasound-guided laparoscopic surgical management of a large uterine scar isthmocele connected with the extra-amniotic space in early pregnancy. A case of a pregnant patient who was diagnosed with a large isthmocele connected with the extra-amniotic space on routine ultrasound at 8 weeks of gestational age is presented. The uterine defect was successfully sutured laparoscopically under ultrasound guidance. The pregnancy continued uneventfully, and a healthy baby was delivered via cesarean section at 38 weeks gestational age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herein is presented a technique for minimally invasive sentinel node mapping. The patient had apparently early stage endometrial cancer. Sentinel node mapping was performed using a hysteroscopic injection of indocyanine green followed by laparoscopic sentinel node detection via near-infrared fluorescence. This technique ensures delineation of lymphatic drainage from the tumor area, thus achieving accurate detection of sentinel nodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Patient-to-image registration is a core process of image-guided surgery (IGS) systems. We present a novel registration approach for application in laparoscopic liver surgery, which reconstructs in real time an intraoperative volume of the underlying intrahepatic vessels through an ultrasound (US) sweep process. METHODS An existing IGS system for an open liver procedure was adapted, with suitable instrument tracking for laparoscopic equipment. Registration accuracy was evaluated on a realistic phantom by computing the target registration error (TRE) for 5 intrahepatic tumors. The registration work flow was evaluated by computing the time required for performing the registration. Additionally, a scheme for intraoperative accuracy assessment by visual overlay of the US image with preoperative image data was evaluated. RESULTS The proposed registration method achieved an average TRE of 7.2 mm in the left lobe and 9.7 mm in the right lobe. The average time required for performing the registration was 12 minutes. A positive correlation was found between the intraoperative accuracy assessment and the obtained TREs. CONCLUSIONS The registration accuracy of the proposed method is adequate for laparoscopic intrahepatic tumor targeting. The presented approach is feasible and fast and may, therefore, not be disruptive to the current surgical work flow.