116 resultados para Phonological Contrast


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The diagnostic value of a contrast-enhanced T2-weighted FLAIR sequence (ceFLAIR) in brain imaging is unclear. HYPOTHESIS/OBJECTIVES That the number of brain lesions detected with ceFLAIR would be no greater than the sum of lesions detected with nFLAIR and ceT1W sequence. ANIMALS One hundred and twenty-nine animals (108 dogs and 21 cats) undergoing magnetic resonance imaging (MRI) of the head between July 2010 and October 2011 were included in the study. METHODS A transverse ceFLAIR was added to a standard brain MRI protocol. Presence and number of lesions were determined based on all available MRI sequences by 3 examiners in consensus and lesion visibility was evaluated for nFLAIR, ceFLAIR, and ceT1W sequences. RESULTS Eighty-three lesions (58 intra-axial and 25 extra-axial) were identified in 51 patients. Five lesions were detected with nFLAIR alone, 2 with ceT1W alone, and 1 with ceFLAIR alone. Significantly higher numbers of lesions were detected using ceFLAIR than nFLAIR (76 versus 67 lesions; P = 0.04), in particular for lesions also detected with ceT1W images (53 versus 40; P =.01). There was no significant difference between the number of lesions detected with combined nFLAIR and ceT1W sequences compared to those detected with ceFLAIR (82 versus 76; P =.25). CONCLUSION AND CLINICAL IMPORTANCE Use of ceFLAIR as a complementary sequence to nFLAIR and ceT1W sequences did not improve the detection of brain lesions and cannot be recommended as part of a routine brain MRI protocol in dogs and cats with suspected brain lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In combined clinical optoacoustic (OA) and ultrasound (US) imaging, epi-mode irradiation and detection integrated into one single probe offers flexible imaging of the human body. The imaging depth in epi-illumination is, however, strongly affected by clutter. As shown in previous phantom experiments, the location of irradiation plays an important role in clutter generation. We investigated the influence of the irradiation geometry on the local image contrast of clinical images, by varying the separation distance between the irradiated area and the acoustic imaging plane of a linear ultrasound transducer in an automated scanning setup. The results for different volunteers show that the image contrast can be enhanced on average by 25% and locally by more than a factor of two, when the irradiated area is slightly separated from the probe. Our findings have an important impact on the design of future optoacoustic probes for clinical application.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In practical forensic casework, backspatter recovered from shooters' hands can be an indicator of self-inflicted gunshot wounds to the head. In such cases, backspatter retrieved from inside the barrel indicates that the weapon found at the death scene was involved in causing the injury to the head. However, systematic research on the aspects conditioning presence, amount and specific patterns of backspatter is lacking so far. Herein, a new concept of backspatter investigation is presented, comprising staining technique, weapon and target medium: the 'triple contrast method' was developed, tested and is introduced for experimental backspatter analysis. First, mixtures of various proportions of acrylic paint for optical detection, barium sulphate for radiocontrast imaging in computed tomography and fresh human blood for PCR-based DNA profiling were generated (triple mixture) and tested for DNA quantification and short tandem repeat (STR) typing success. All tested mixtures yielded sufficient DNA that produced full STR profiles suitable for forensic identification. Then, for backspatter analysis, sealed foil bags containing the triple mixture were attached to plastic bottles filled with 10 % ballistic gelatine and covered by a 2-3-mm layer of silicone. To simulate backspatter, close contact shots were fired at these models. Endoscopy of the barrel inside revealed coloured backspatter containing typable DNA and radiographic imaging showed a contrasted bullet path in the gelatine. Cross sections of the gelatine core exhibited cracks and fissures stained by the acrylic paint facilitating wound ballistic analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whereas semantic, logical, and narrative features of verbal humor are well-researched, phonological and prosodic dimensions of verbal funniness are hardly explored. In a 2 × 2 design we varied rhyme and meter in humorous couplets. Rhyme and meter enhanced funniness ratings and supported faster processing. Rhyming couplets also elicited more intense and more positive affective responses, increased subjective comprehensibility and more accurate memory. The humor effect is attributed to special rhyme and meter features distinctive of humoristic poetry in several languages. Verses that employ these formal features make an artful use of typical poetic vices of amateurish poems written for birthday parties or other occasions. Their metrical patterning sounds “mechanical” rather than genuinely “poetic”; they also disregard rules for “good” rhymes. The processing of such verses is discussed in terms of a metacognitive integration of their poetically deviant features into an overall effect of processing ease. The study highlights the importance of nonsemantic rhetorical features in language processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: There is limited information on potential diffusion of local anaesthetic solution after various diagnostic analgesic techniques of the proximal metacarpal region. OBJECTIVE: To document potential distribution of local anaesthetic solution following 4 techniques used for diagnostic analgesia of the proximal metacarpal region. METHODS: Radiodense contrast medium was injected around the lateral palmar or medial and lateral palmar metacarpal nerves in 8 mature horses, using 4 different techniques. Radiographs were obtained 0, 10 and 20 min after injection and were analysed subjectively. A mixture of radiodense contrast medium and methylene blue was injected into 4 cadaver limbs; the location of the contrast medium and dye was determined by radiography and dissection. RESULTS: Following perineural injection of the palmar metacarpal nerves, most of the contrast medium was distributed in an elongated pattern axial to the second and fourth metacarpal bones. The carpometacarpal joint was inadvertently penetrated in 4/8 limbs after injections of the palmar metacarpal nerves from medial and lateral approaches, and in 1/8 limbs when both injections were performed from the lateral approach. Following perineural injection of the lateral palmar nerve using a lateral approach, the contrast medium was diffusely distributed in all but one limb, in which the carpal sheath was inadvertently penetrated. In 5/8 limbs, following perineural injection of the lateral palmar nerve using a medial approach, the contrast medium diffused proximally to the distal third of the antebrachium. CONCLUSIONS AND POTENTIAL RELEVANCE: Inadvertent penetration of the carpometacarpal joint is common after perineural injection of the palmar metacarpal nerves, but less so if both palmar metacarpal nerves are injected using a lateral approach. Following injection of the lateral palmar nerve using a medial approach, the entire palmar aspect of the carpus may be desensitised.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the contrast formation in the local contact potential difference (LCPD) measured by Kelvin probe force microscopy (KPFM) on single charge-transfer complexes (CTCs) on a NaCl bilayer on Cu(111). At different tip heights, we found quantitatively different LCPD contrasts that characterize different properties of the molecule. In the small distance regime, the tip penetrates the electron density of the molecule, and the contrast is related to the size and topography of the electron shell of the molecule. For larger distances, the LCPD contrast corresponds to the electrostatic field above the molecule. However, in the medium-distance regime, that is, for tip heights similar to the size of the molecule, the nonspherical distribution of π- and σ-electrons often conceals the effect of the partial charges within the molecule. Only for large distances does the LCPD map converge toward the simple field of a dipole for a polar molecule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE In contrast to conventional breast imaging techniques, one major diagnostic benefit of breast magnetic resonance imaging (MRI) is the simultaneous acquisition of morphologic and dynamic enhancement characteristics, which are based on angiogenesis and therefore provide insights into tumor pathophysiology. The aim of this investigation was to intraindividually compare 2 macrocyclic MRI contrast agents, with low risk for nephrogenic systemic fibrosis, in the morphologic and dynamic characterization of histologically verified mass breast lesions, analyzed by blinded human evaluation and a fully automatic computer-assisted diagnosis (CAD) technique. MATERIALS AND METHODS Institutional review board approval and patient informed consent were obtained. In this prospective, single-center study, 45 women with 51 histopathologically verified (41 malignant, 10 benign) mass lesions underwent 2 identical examinations at 1.5 T (mean time interval, 2.1 days) with 0.1-mmol kg doses of gadoteric acid and gadobutrol. All magnetic resonance images were visually evaluated by 2 experienced, blinded breast radiologists in consensus and by an automatic CAD system, whereas the morphologic and dynamic characterization as well as the final human classification of lesions were performed based on the categories of the Breast imaging reporting and data system MRI atlas. Lesions were also classified by defining their probability of malignancy (morpho-dynamic index; 0%-100%) by the CAD system. Imaging results were correlated with histopathology as gold standard. RESULTS The CAD system coded 49 of 51 lesions with gadoteric acid and gadobutrol (detection rate, 96.1%); initial signal increase was significantly higher for gadobutrol than for gadoteric acid for all and the malignant coded lesions (P < 0.05). Gadoteric acid resulted in more postinitial washout curves and fewer continuous increases of all and the malignant lesions compared with gadobutrol (CAD hot spot regions, P < 0.05). Morphologically, the margins of the malignancies were different between the 2 agents, whereas gadobutrol demonstrated more spiculated and fewer smooth margins (P < 0.05). Lesion classifications by the human observers and by the morpho-dynamic index compared with the histopathologic results did not significantly differ between gadoteric acid and gadobutrol. CONCLUSIONS Macrocyclic contrast media can be reliably used for breast dynamic contrast-enhanced MRI. However, gadoteric acid and gadobutrol differed in some dynamic and morphologic characterization of histologically verified breast lesions in an intraindividual, comparison. Besides the standardization of technical parameters and imaging evaluation of breast MRI, the standardization of the applied contrast medium seems to be important to receive best comparable MRI interpretation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Native-MR angiography (N-MRA) is considered an imaging alternative to contrast enhanced MR angiography (CE-MRA) for patients with renal insufficiency. Lower intraluminal contrast in N-MRA often leads to failure of the segmentation process in commercial algorithms. This study introduces an in-house 3D model-based segmentation approach used to compare both sequences by automatic 3D lumen segmentation, allowing for evaluation of differences of aortic lumen diameters as well as differences in length comparing both acquisition techniques at every possible location. METHODS AND MATERIALS Sixteen healthy volunteers underwent 1.5-T-MR Angiography (MRA). For each volunteer, two different MR sequences were performed, CE-MRA: gradient echo Turbo FLASH sequence and N-MRA: respiratory-and-cardiac-gated, T2-weighted 3D SSFP. Datasets were segmented using a 3D model-based ellipse-fitting approach with a single seed point placed manually above the celiac trunk. The segmented volumes were manually cropped from left subclavian artery to celiac trunk to avoid error due to side branches. Diameters, volumes and centerline length were computed for intraindividual comparison. For statistical analysis the Wilcoxon-Signed-Ranked-Test was used. RESULTS Average centerline length obtained based on N-MRA was 239.0±23.4 mm compared to 238.6±23.5 mm for CE-MRA without significant difference (P=0.877). Average maximum diameter obtained based on N-MRA was 25.7±3.3 mm compared to 24.1±3.2 mm for CE-MRA (P<0.001). In agreement with the difference in diameters, volumes obtained based on N-MRA (100.1±35.4 cm(3)) were consistently and significantly larger compared to CE-MRA (89.2±30.0 cm(3)) (P<0.001). CONCLUSIONS 3D morphometry shows highly similar centerline lengths for N-MRA and CE-MRA, but systematically higher diameters and volumes for N-MRA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. METHODS The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with κ-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. RESULTS A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [κ = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000). CONCLUSION Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Contrast-enhanced diagnostic imaging techniques are considered useful in veterinary and human medicine to evaluate liver perfusion and focal hepatic lesions. Although hepatic diseases are a common occurrence in reptile medicine, there is no reference to the use of contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) to evaluate the liver in lizards. Therefore, the aim of this study was to evaluate the pattern of change in echogenicity and attenuation of the liver in green iguanas (Iguana iguana) after administration of specific contrast media. RESULTS An increase in liver echogenicity and density was evident during CEUS and CECT, respectively. In CEUS, the mean ± SD (median; range) peak enhancement was 19.9% ± 7.5 (18.3; 11.7-34.6). Time to peak enhancement was 134.0 ± 125.1 (68.4; 59.6-364.5) seconds. During CECT, first visualization of the contrast medium was at 3.6 ± 0.5 (4; 3-4) seconds in the aorta, 10.7 ± 2.2 (10.5; 7-14) seconds in the hepatic arteries, and 15 ± 4.5 (14.5; 10-24) seconds in the liver parenchyma. Time to peak was 14.1 ± 3.4 (13; 11-21) and 31 ± 9.6 (29; 23-45) seconds in the aorta and the liver parenchyma, respectively. CONCLUSION CEUS and dynamic CECT are practical means to determine liver hemodynamics in green iguanas. Distribution of contrast medium in iguana differed from mammals. Specific reference ranges of hepatic perfusion for diagnostic evaluation of the liver in iguanas are necessary since the use of mammalian references may lead the clinician to formulate incorrect diagnostic suspicions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate treatment response of hepatocellular carcinoma (HCC) after transarterial chemoembolization (TACE) with a new real-time imaging fusion technique of contrast-enhanced ultrasound (CEUS) with multi-slice detection computed tomography (CT) in comparison to conventional post-interventional follow-up. MATERIAL AND METHODS 40 patients with HCC (26 male, ages 46-81 years) were evaluated 24 hours after TACE using CEUS with ultrasound volume navigation and image fusion with CT compared to non-enhanced CT and follow-up contrast-enhanced CT after 6-8 weeks. Reduction of tumor vascularization to less than 25% was regarded as "successful" treatment, whereas reduction to levels >25% was considered as "partial" treatment response. Homogenous lipiodol retention was regarded as successful treatment in non-enhanced CT. RESULTS Post-interventional image fusion of CEUS with CT was feasible in all 40 patients. In 24 patients (24/40), post-interventional image fusion with CEUS revealed residual tumor vascularity, that was confirmed by contrast-enhanced CT 6-8 weeks later in 24/24 patients. In 16 patients (16/40), post-interventional image fusion with CEUS demonstrated successful treatment, but follow-up CT detected residual viable tumor (6/16). Non-enhanced CT did not identify any case of treatment failure. Image fusion with CEUS assessed treatment efficacy with a specificity of 100%, sensitivity of 80% and a positive predictive value of 1 (negative predictive value 0.63). CONCLUSIONS Image fusion of CEUS with CT allows a reliable, highly specific post-interventional evaluation of embolization response with good sensitivity without any further radiation exposure. It can detect residual viable tumor at early state, resulting in a close patient monitoring or re-therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PAMAM dendrimers functionalized with nitronyl nitroxide radicals were characterized. Quantitative determination of substitution with radicals was performed using EPR and electrochemical methods. The study of the 1H NMR relaxation of the surrounding water showed how the outer-sphere contribution to the relaxivity may be limited by the presence of the dendrimer core.