107 resultados para DEVICE
Resumo:
Objective: To investigate objective and subjective effects of an adjunctive contralateral routing of signal (CROS) device at the untreated ear in patients with a unilateral cochlear implant (CI). Design: Prospective study of 10 adult experienced unilateral CI users with bilateral severe-to-profound hearing loss. Speech in noise reception (SNR) and sound localization were measured with and without the additional CROS device. SNR was measured by applying speech signals at the untreated/CROS side while noise signals came from the front (S90N0). For S0N90, signal sources were switched. Sound localization was measured in a 12-loudspeaker full circle setup. To evaluate the subjective benefit, patients tried the device for 2 weeks at home, then filled out the abbreviated Speech, Spatial and Qualities of Hearing Scale as well as the Bern benefit in single-sided deafness questionnaires. Results: In the setting S90N0, all patients showed a highly significant SNR improvement when wearing the additional CROS device (mean 6.4 dB, p < 0.001). In the unfavorable setting S0N90, only a minor deterioration of speech understanding was noted (mean -0.66 dB, p = 0.54). Sound localization did not improve substantially with CROS. In the two questionnaires, 12 of 14 items showed an improvement in mean values, but none of them was statistically significant. Conclusion: Patients with unilateral CI benefit from a contralateral CROS device, particularly in a noisy environment, when speech comes from the CROS ear side. © 2014 S. Karger AG, Basel.
Resumo:
After standard hip arthroplasty, an 82-year-old patient with previously undiagnosed diffuse idiopathic skeletal hyperostosis of the cervical spine experienced life-threatening side effects after use of a supraglottic airway device (i-gel). Extensive mucosal erosion and denudation of the cricoid cartilage caused postoperative supraglottic swelling and prolonged respiratory failure requiring tracheostomy. In this case report, we highlight the importance of evaluating risk factors for failure of supraglottic airway devices.
Resumo:
AIM To evaluate the performance of a pen‑type laser fluorescence device (DIAGNOdent 2190; LFpen, KaVo, Germany) and bitewing radiographs (BW) for approximal caries detection in permanent and primary teeth. MATERIALS AND METHODS A total of 246 anterior approximal surfaces (102 permanent and 144 primary) were selected. Contact points were simulated using sound teeth. Two examiners assessed all approximal surfaces using LFpen and BW. The teeth were histologically assessed for the reference standard. Optimal cut‑off limits were calculated for LFpen for primary and permanent teeth. Sensitivity, specificity, accuracy and area under the receiver operating characteristic curve (Az) were calculated for D1 (enamel and dentin lesions) and D3 (dentin lesions) thresholds. The reproducibility was assessed by intraclass correlation coefficient (ICC) and Cohen's weighted kappa values. RESULTS For permanent teeth, the LFpen cut‑off were 0- 27 (sound), 28- 33 (enamel caries) and >33 (dentin caries). For primary teeth, the LFpen cut‑off were 0- 7 (sound), 8- 32 (enamelcaries) and >32 (dentin caries). The LFpen presented higher sensitivity values than BW for primary teeth (0.58 vs. 0.32 at D1 and 0.80 vs. 0.47 at D3) and permanent teeth (0.80 vs. 0.57 at D1 and 0.94 vs. 0.51 at D3). Specificity did not show a significant difference between the methods. Rank correlations with histology were 0.59 and 0.83 (LFpen) and 0.36 and 0.70 (BW) for primary and permanent teeth, respectively, considering all lesions. ICC values for LFpen were 0.71 (inter) and 0.86 (intra) for permanent teeth and 0.94 (inter) and 0.90/0.99 for primary teeth. Kappa values for BW were 0.69 (inter) and 0.68/0.90 (intra) for permanent teeth and 0.64 (inter) and 0.89/0.89 for primary teeth. CONCLUSION LFpen presented better reproducibility for primary and permanent teeth and higher accuracy in detecting caries lesions at D1 threshold than BW for permanent teeth. LFpen should be used as an adjunct method for approximal caries detection.
Resumo:
RATIONALE Early reperfusion in patients experiencing acute ischemic stroke is critical, especially for patients with large vessel occlusion who have poor prognosis without revascularization. Solitaire™ stent retriever devices have been shown to immediately restore vascular perfusion safely, rapidly, and effectively in acute ischemic stroke patients with large vessel occlusions. AIM The aim of the study was to demonstrate that, among patients with large vessel, anterior circulation occlusion who have received intravenous tissue plasminogen activator, treatment with Solitaire revascularization devices reduces degree of disability 3 months post stroke. DESIGN The study is a global multicenter, two-arm, prospective, randomized, open, blinded end-point trial comparing functional outcomes in acute ischemic stroke patients who are treated with either intravenous tissue plasminogen activator alone or intravenous tissue plasminogen activator in combination with the Solitaire device. Up to 833 patients will be enrolled. PROCEDURES Patients who have received intravenous tissue plasminogen activator are randomized to either continue with intravenous tissue plasminogen activator alone or additionally proceed to neurothrombectomy using the Solitaire device within six-hours of symptom onset. STUDY OUTCOMES The primary end-point is 90-day global disability, assessed with the modified Rankin Scale (mRS). Secondary outcomes include mortality at 90 days, functional independence (mRS ≤ 2) at 90 days, change in National Institutes of Health Stroke Scale at 27 h, reperfusion at 27 h, and thrombolysis in cerebral infarction 2b/3 flow at the end of the procedure. ANALYSIS Statistical analysis will be conducted using simultaneous success criteria on the overall distribution of modified Rankin Scale (Rankin shift) and proportions of subjects achieving functional independence (mRS 0-2).
Resumo:
In Switzerland 200’000 people suffer from congestive heart failure. Approximately 10’000 patients find themselves in an advanced state of the disease. When conservative treatment options are no longer available heart transplantation is the therapy of choice. Should this not be an option due to long waiting lists or medical issues assist device therapy becomes an option. Assist device therapy is separated in short-term and long-term support. Long-term support is nowadays performed with ventricular assist devices (VADs). The native heart is still in place and supported in parallel to the remaining function of the heart. The majority of patients are treated with a left ventricular assist device (LVAD). The right ventrical alone (RVAD) as well as bi-ventricular support (BiVAD) is rarely needed. The modern VADs are implantable and create a non-pulsative bloodflow. A percutaneous driveline enables energy supply and pump-control. Indication strategies for VAD implantations include bridge to transplant (short term support), bridge to candidacy and bridge to transplant. VADs become more and more a definite therapeutic option (destination therapy). VAD therapy might be a realistic alternative to organ transplantation in the near future.
Resumo:
The aim of this study was to test a newly developed LED-based fluorescence device for approximal caries detection in vitro. We assembled 120 extracted molars without frank cavitations or fillings pairwise in order to create contact areas. The teeth were independently assessed by two examiners using visual caries detection (International Caries Detection and Assessment System, ICDAS), bitewing radiography (BW), laser fluorescence (LFpen), and LED fluorescence (Midwest Caries I.D., MW). The measurements were repeated at least 1 week later. The diagnostic performance was calculated with Bayesian analyses. Post-test probabilities were calculated in order to judge the diagnostic performance of combined methods. Reliability analyses were performed using kappa statistics for nominal data and intraclass correlation (ICC) for absolute data. Histology served as the gold standard. Sensitivities/specificities at the enamel threshold were 0.33/0.84 for ICDAS, 0.23/0.86 for BW, 0.47/0.78 for LFpen, and 0.32/0.87 for MW. Sensitivities/specificities at the dentine threshold were 0.04/0.89 for ICDAS, 0.27/0.94 for BW, 0.39/0.84 for LFpen, and 0.07/0.96 for MW. Reliability data were fair to moderate for MW and good for BW and LFpen. The combination of ICDAS and radiography yielded the best diagnostic performance (post-test probability of 0.73 at the dentine threshold). The newly developed LED device is not able to be recommended for approximal caries detection. There might be too much signal loss during signal transduction from the occlusal aspect to the proximal lesion site and the reverse.
Resumo:
The utility and inter-session repeatability of sensory threshold measurements using an electronic von Frey anesthesiometer (VFA) were assessed in a group of six neurologically normal dogs. Sensory threshold values obtained in neurologically normal dogs were compared to those of dogs with acute spinal cord injury (SCI) caused by intervertebral disc extrusion (n=6) and to a group of neurologically normal dogs with cranial cruciate ligament rupture (CCLR; n=6). Sensory threshold values in neurologically normal dogs were 155.8 ± 37.7 g and 154.7 ± 67.2 g for the left and right pelvic limbs, respectively. The difference in mean sensory threshold values obtained for the group when two distinct testing sessions were compared was not statistically significant (P>0.05). Mean sensory threshold values for the group with SCI were significantly higher than those for neurologically normal dogs at 351.1 ± 116.5 g and 420.3 ± 157.7 g for the left and right pelvic limbs, respectively (P=0.01). A comparison of sensory threshold values for the group with CCLR and neurologically normal dogs was not statistically significant (P>0.05). The modified dorsal technique for VFA described here represents a reliable method to assess sensory threshold in neurologically normal dogs and in those with SCI.
Resumo:
Venous angioplasty with stenting of iliac veins is an important treatment option for patients suffering from post-thrombotic syndrome due to chronic venous obstruction. Interventional treatment of a chronically occluded vena cava, however, is challenging and often associated with failure. We describe a case of a chronic total occlusion of the entire inferior vena cava that was successfully recanalized using bidirectional wire access and a balloon puncture by a re-entry catheter to establish patency of the inferior vena cava.
Resumo:
CONTEXT Radiolabelled choline positron emission tomography has changed the management of prostate cancer patients. However, new emerging radiopharmaceutical agents, like radiolabelled prostate specific membrane antigen, and new promising hybrid imaging will begin new challenges in the diagnostic field. OBJECTIVE The continuous evolution in nuclear medicine has led to the improvement in the detection of recurrent prostate cancer (PCa), particularly distant metastases. New horizons have been opened for radiolabelled choline positron emission tomography (PET)/computed tomography (CT) as a guide for salvage therapy or for the assessment of systemic therapies. In addition, new tracers and imaging tools have been recently tested, providing important information for the management of PCa patients. Herein we discuss: (1) the available evidence in literature on radiolabelled choline PET and their recent indications, (2) the role of alternative radiopharmaceutical agents, and (3) the advantages of a recent hybrid imaging device (PET/magnetic resonance imaging) in PCa. EVIDENCE ACQUISITION Data from recently published (2010-2015), original articles concerning the role of choline PET/CT, new emerging radiotracers, and a new imaging device are analysed. This review is reported according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. EVIDENCE SYNTHESIS In the restaging phase, the detection rate of choline PET varies between 4% and 97%, mainly depending on the site of recurrence and prostate-specific antigen levels. Both 68gallium (68Ga)-prostate specific membrane antigen and 18F-fluciclovine are shown to be more accurate in the detection of recurrent disease as compared with radiolabelled choline PET/CT. Particularly, Ga68-PSMA has a detection rate of 50% and 68%, respectively for prostate-specific antigen levels < 0.5ng/ml and 0.5-2ng/ml. Moreover, 68Ga- PSMA PET/magnetic resonance imaging demonstrated a particularly higher accuracy in detecting PCa than PET/CT. New tracers, such as radiolabelled bombesin or urokinase-type plasminogen activator receptor, are promising, but few data in clinical practice are available today. CONCLUSIONS Some limitations emerge from the published papers, both for radiolabelled choline PET/CT and also for new radiopharmaceutical agents. Efforts are still needed to enhance the impact of published data in the world of oncology, in particular when new radiopharmaceuticals are introduced into the clinical arena. PATIENT SUMMARY In the present review, the authors summarise the last evidences in clinical practice for the assessment of prostate cancer, by using nuclear medicine modalities, like positron emission tomography/computed tomography and positron emission tomography/magnetic resonance imaging.
Resumo:
INTRODUCTION Surgical decompression for lumbar spinal stenosis (LSS) has been associated with poorer outcomes in patients with pronounced low back pain (LBP) as compared to patients with predominant leg pain. This cross registry study assessed potential benefits of the interlaminar coflex® device as an add-on to bony decompression alone. METHODS Patients with lumbar decompression plus coflex® (SWISSspine registry) were compared with decompressed controls (Spine Tango registry). Inclusion criteria were LSS and a preoperative back pain level of ≥5 points. 1:1 propensity score-based matching was performed. Outcome measures were back and leg pain relief, COMI score improvement, patient satisfaction, complication, and revision rates. RESULTS 50 matched pairs without residual significant differences but age were created. At the 7-9 months follow-up interval the coflex® group had higher back (p=0.014) and leg pain relief (p<0.001) and COMI score improvement (p=0.029) than the decompression group. Patient satisfaction was 90% in both groups. No revision was documented in the coflex® and one in the decompression group (2.0%). DISCUSSION In the short-term, lumbar decompression with coflex® compared with decompression alone in patients with LSS and pronounced LBP at baseline is a safe and effective treatment option that appears beneficial regarding clinical and functional outcomes. However, residual confounding of non-measured covariables may have partially influenced our findings. Also, despite careful inclusion and exclusion of cases the cross registry approach introduces a potential for selection bias that we could not totally control for and that makes additional studies necessary.
Resumo:
STUDY DESIGN Retrospective analysis of prospectively collected clinical data. OBJECTIVE To assess the long-term outcome of patients with monosegmental L4/5 degenerative spondylolisthesis treated with the dynamic Dynesys device. SUMMARY OF BACKGROUND DATA The Dynesys system has been used as a semirigid, lumbar dorsal pedicular stabilization device since 1994. Good short-term results have been reported, but little is known about the long-term outcome after treatment for degenerative spondylolisthesis at the L4/5 level. METHODS A total of 39 consecutive patients with symptomatic degenerative lumbar spondylolisthesis at the L4/5 level were treated with bilateral decompression and Dynesys instrumentation. At a mean follow-up of 7.2 years (range, 5.0-11.2 y), they underwent clinical and radiographic evaluation and quality of life assessment. RESULTS At final follow-up, back pain improved in 89% and leg pain improved in 86% of patients compared with preoperative status. Eighty-three percent of patients reported global subjective improvement. Ninety-two percent would undergo the surgery again. Eight patients (21%) required further surgery because of symptomatic adjacent segment disease (6 cases), late-onset infection (1 case), and screw breakage (1 case). In 9 cases, radiologic progression of spondylolisthesis at the operated segment was found. Seventy-four percent of operated segments showed limited flexion-extension range of <4 degrees. Adjacent segment pathology, although without clinical correlation, was diagnosed at the L5/S1 (17.9%) and L3/4 (28.2%) segments. In 4 cases, asymptomatic screw loosening was observed. CONCLUSIONS Monosegmental Dynesys instrumentation of degenerative spondylolisthesis at L4/5 shows good long-term results. The rate of secondary surgeries is comparable to other dorsal instrumentation devices. Residual range of motion in the stabilized segment is reduced, and the rate of radiologic and symptomatic adjacent segment degeneration is low. Patient satisfaction is high. Dynesys stabilization of symptomatic L4/5 degenerative spondylolisthesis is a possible alternative to other stabilization devices.