125 resultados para Arthroplasty
Resumo:
Synovial chondromatosis of the hip is a rare disorder with few published reports regarding treatment and outcomes, and therefore, selecting the optimal surgical treatment is difficult. We reviewed eight patients with monoarticular synovial chondromatosis of the hip who had joint débridement and a modified total synovectomy performed through a surgical hip dislocation with a trochanteric flip osteotomy. Patients were evaluated for recurrence of disease, progression of osteoarthritis, clinical outcomes, and subsequent reoperations. The minimum followup was 4 years (mean, 6.5 years). At final review, no patient had recurrence of disease. Two patients had progression of osteoarthritis requiring total hip arthroplasties at 5 and 10 years after the initial surgical intervention. These patients did not show recurrent disease on histologic examination of the synovial membrane at the time of the arthroplasty. The six patients with preserved joints were followed up for a mean of 6.2 years. The mean Merle d'Aubigné and Postel score in this group was 16.5 points (range, 15-18 points) at the latest followup. There were no major or minor complications related to this treatment. Our midterm results suggest that open débridement with modified total synovectomy is an effective treatment that prevents recurrence of disease and provides substantial pain relief. Surgical hip dislocation allows safe and complete access to the joint for débridement and synovectomy with no added morbidity.
Resumo:
OBJECTIVE: To compare six different parameters described in literature for estimation of pelvic tilt on an anteroposterior pelvic radiograph and to create a simple nomogram for tilt correction of prosthetic cup version in total hip arthroplasty. DESIGN: Simultaneous anteroposterior and lateral pelvic radiographs are taken routinely in our institution and were analyzed prospectively. The different parameters (including three distances and three ratios) were measured and compared to the actual pelvic tilt on the lateral radiograph using simple linear regression analysis. PATIENTS: One hundred and four consecutive patients (41 men, 63 women with a mean age of 31.7 years, SD 9.2 years, range 15.7-59.1 years) were studied. RESULTS: The strongest correlation between pelvic tilt and one of the six parameters for both men and women was the distance between the upper border of the symphysis and the sacrococcygeal joint. The correlation coefficient was 0.68 for men (P<0.001) and 0.61 for women (P<0.001). Based on this linear correlation, a nomogram was created that enables fast, tilt-corrected cup version measurements in clinical routine use. CONCLUSION: This simple method for correcting variations in pelvic tilt on plain radiographs can potentially improve the radiologist's ability to diagnose and interpret malformations of the acetabulum (particularly acetabular retroversion and excessive acetabular overcoverage) and post-operative orientation of the prosthetic acetabulum.
Resumo:
In the discussion about the rationale for spine registries, two basic questions have to be answered. The first one deals with the value of orthopaedic registries per se, considering them as observational studies and comparing the evidence they generate with that of randomised controlled trials. The second question asks if the need for registries in spine surgery is similar to that in the arthroplasty sector. The widely held view that randomised controlled trials are the 'gold standard' for evaluation and that observational methods have little or no value ignores the limitations of randomised trials. They may prove unnecessary, inappropriate, impossible, or inadequate. In addition, the external validity and hence the ability to make generalisations about the results of randomised trials is often low. Therefore, the false conflict between those who advocate randomised trials in all situations and those who believe observational data provide sufficient evidence needs to be replaced with mutual recognition of their complementary roles. The fact that many surgical techniques or technologies were introduced into the field of spine surgery without randomised trials or prospective cohort comparisons makes obvious an even increased need for spine registries compared to joint arthroplasty. An essential methodological prerequisite for a registry is a common terminology for reporting results and a sophisticated technology that networks all participants so that one central data pool is created and accessed. Recognising this need, the Spine Society of Europe has researched and developed Spine Tango, the first European spine registry, which can be accessed under www.eurospine.org.
Resumo:
Ligament balancing in total knee arthroplasty may have an important influence on joint stability and prosthesis lifetime. In order to provide quantitative information and assistance during ligament balancing, a device that intraoperatively measures knee joint forces and moments was developed. Its performance and surgical advantages were evaluated on six cadaver specimens mounted on a knee joint loading apparatus allowing unconstrained knee motion as well as compression and varus-valgus loading. Four different experiments were performed on each specimen. (1) Knee joints were axially loaded. Comparison between applied and measured compressive forces demonstrated the accuracy and reliability of in situ measurements (1.8N). (2) Assessment of knee stability based on condyle contact forces or varus-valgus moments were compared to the current surgical method (difference of varus-valgus loads causing condyle lift-off). The force-based approach was equivalent to the surgical method while the moment-based, which is considered optimal, showed a tendency of lateral imbalance. (3) To estimate the importance of keeping the patella in its anatomical position during imbalance assessment, the effect of patellar eversion on the mediolateral distribution of tibiofemoral contact forces was measured. One fourth of the contact force induced by the patellar load was shifted to the lateral compartment. (4) The effect of minor and major medial collateral ligament releases was biomechanically quantified. On average, the medial contact force was reduced by 20% and 46%, respectively. Large variation among specimens reflected the difficulty of ligament release and the need for intraoperative force monitoring. This series of experiments thus demonstrated the device's potential to improve ligament balancing and survivorship of total knee arthroplasty.
Resumo:
Less invasive methods of performing total hip arthroplasty have been considered controversial after increased complication rates and component malpositioning were reported. A new method of performing total hip arthroplasty through an incision in the superior capsule, posterior to the abductors and anterior to the posterior capsule, was developed with the aim of producing a technique that maintained the joint stability of the transgluteal exposure and the rapid abductor recovery of the posterior exposure. We assessed the recovery and complications of this technique performed with surgical navigation. The study group was compared with similar subjects who had conventional total hip arthroplasty, without surgical navigation, using the transgluteal exposure. There were 185 consecutive total hip arthroplasties in the study group and 189 nonconsecutive historical total hip arthroplasties in the control group. The two groups were controlled for complexity and had no differences in body mass index, gender, diagnosis, operative side, bilateral operations, and previous surgeries. Patients were evaluated for clinical recovery and perioperative complications at 9 and 24 weeks. The study group recovered faster at both followup examinations. The study group had fewer perioperative and postoperative complications compared with the control group. Accuracy of component positioning was not compromised compared to the control group. Less invasive surgery with the philosophy of maximally preserving the abductors, posterior capsule, and short rotators may result in a safer operation with faster recovery than traditional techniques.
Resumo:
From June 1997 to June 2003 we performed 194 total hip arthroplasties on 173 patients using alumina ceramic-on-ceramic bearings as part of a prospective United States Food and Drug Administration/Investigational Device Exemption study. The average patient age at surgery was 49.9 years. Minimum followup time was 2 years (mean 4.3 years, range 2-9 years). We evaluated survival rate, implant- and nonimplant-related complications. Clinical outcomes included the Merle d'Aubigné score. We assessed radiographs for signs of osteolysis, component loosening, and implant wear. No patients had osteolysis and there were no hip dislocations. Implant survivorship for all hips with aseptic revision of any component was 96% (CI, 91-100) at 9 year; survivorship for hips without prior surgery was 99.3%, (CI, 98-100). There was a 1.7% incidence of implant-related complications. Our data help confirm two United States FDA/IDE studies on alumina ceramic-on-ceramic total hip arthroplasty that reported low aseptic revision rates and low revision rates for instability. Total hip arthroplasty using alumina ceramic-on-ceramic implants is a safe and reliable procedure in the comparably young and active patient.
Resumo:
In the last years life duration of shoulder prostheses could be prolonged through improvement of prosthesis quality, instrumentation and surgical techniques. After shoulder total arthroplasty, the patients show signifi cant reduction of pain and good functional mid and long term results. Indication to shoulder arthroplasty can be made by even younger and sportive active patients. Many sport activities remain possible after implantation of a shoulder prosthesis. A systematic rehabilitation is mandatory to yield optimal functional results. Intensity of sports activities should remain in relation with the preoperative status. Activities with total contact and high impaction strength should be avoided to extend the duration of life of the prosthesis.
Resumo:
PURPOSE: The purpose of this study was to determine the depth of penetration from mechanical chondroplasty and metabolic consequences of this procedure on the remaining articular cartilage. METHODS: Mechanical chondroplasty was performed in vitro on a portion of fresh grade I or II articular cartilage from 8 human knee arthroplasty specimens. Treated and control (untreated) explants (approximately 30 mg) were cut from the cartilage. The explants were divided into 2 groups, day 1 and day 4, placed separately in a 48-well plate containing media, and incubated at 37 degrees C for 24 hours. After the 24-hour incubation, the explants were weighed on day 1 and day 4, and explant media were removed and tested for total proteoglycan synthesis and aggrecan synthesis. At time 0, 2 sets (2.6 mm each) of treated and control cartilage slices were cut with a precision saw. One set was stained for confocal laser microscopy via a cytotoxicity stain to determine cell viability. The second set was stained with H;E to determine depth of penetration. RESULTS: The mean depth of penetration was 252.8 +/- 78 microm. There was no significant difference (P > .25) between total proteoglycan synthesis for control versus treatment groups on day 1 or 4. Aggrecan synthesis was significantly reduced on day 1 when normalized for tissue weight (P = .019) and double-stranded deoxyribonucleic acid (P = .004). On day 4, no significant difference was detected. Confocal laser microscopy did not show cell death below the zone of treatment. CONCLUSIONS: There was no significant metabolic consequence caused by chondroplasty to the remaining articular cartilage, and the zone of injury was limited to the treatment area. CLINICAL RELEVANCE: Mechanical chondroplasty causes no significant metabolic consequences to articular cartilage under these conditions.
Resumo:
Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.
Resumo:
This paper addresses the problem of estimating postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. The widely used procedure of evaluation of cup orientation following total hip arthroplasty using single standard anteroposterior radiograph is known inaccurate, largely due to the wide variability in individual pelvic position relative to X-ray plate. 2D-3D image registration methods have been introduced to estimate the rigid transformation between a preoperative CT volume and postoperative radiograph(s) for an accurate estimation of the postoperative cup alignment relative to an anatomical reference extracted from the CT data. However, these methods require either multiple radiographs or a radiograph-specific calibration, both of which are not avaiable for most retrospective studies. Furthermore, these methods were only evaluated on X-ray radiograph(s) without gonadal shielding. In this paper, we propose to use a hybrid 2D-3D registration scheme combining an iterative landmark-to-ray registration with a 2D-3D intensity-based registration to estimate the rigid transfromation for a precise estimation of cup alignment. Quantitative and qualitative results evaluated on clinical and cadaveric datasets are given which indicate the validity of our approach.
Resumo:
Despite different operative and non-operative treatment regimens, the outcome after femoral head fractures has changed little over the past decades. The initial trauma itself as well as secondary changes such as posttraumatic osteoarthritis, avascular necrosis or heterotopic ossification is often responsible for severe loss of function of the afflicted hip joint. Anatomic reduction of all fracture fragments seems to be a major influencing factor in determining the outcome quality. Eight years ago we inaugurated a new surgical approach for better access and visualisation for the treatment of femoral head fractures, using the "trochanteric flip" (digastric) osteotomy. Thus inspection of the entire hip joint and accurate fragment reduction under direct visual control are possible. After good initial experiences with this operative procedure we changed our standard treatment regimen to this approach in an attempt to achieve the most accurate anatomic reduction of the femoral head in every affected patient. Between 1998 and 2006 we operated on 12 patients with femoral head fractures associated with posterior hip dislocation, using the new surgical approach. Patients were followed for 2-96 months and outcome was documented with the Merle d'Aubigne and Postel score as well as the Thompson and Epstein score. The posttraumatic formation of heterotopic bone was documented with the Brooker score. Retrospective analysis of these 12 patients showed good or excellent results in 10 patients (83.3%). The two patients with poor outcome developed an avascular necrosis of the femoral head and underwent total hip arthroplasty. Periarticular heterotopic ossification was seen in five patients. In four patients this caused a significantly reduced range of motion and was therefore considered as a posttraumatic complication. The two patients with the most severe heterotopic bone formation (Brooker III and IV) had initially sustained multiple injuries including brain injury. Comparing our results with earlier published series including our own before changing the treatment protocol, the data suggest a favorable outcome in patients with trochanteric flip (digastric) osteotomy for the treatment of femoral head fractures.
Resumo:
BACKGROUND: Recently recommended treatment modalities for prosthetic joint infection (PJI) were evaluated. METHODS: A retrospective cohort analysis of 68 patients with PJI of hip or knee who were treated from 1995 through 2004 was conducted at the University Hospital Bern (Bern, Switzerland). RESULTS: A 2-stage exchange was the most frequent (75.0%) surgical strategy, followed by retention and debridement (17.6%), 1-stage exchange (5.9%), and resection arthroplasty or suppressive antimicrobial treatment (1.5%). The chosen strategy was in 88% agreement with the recommendations. Adherence was only 17% for retention and debridement and was 0% for 1-stage exchange. Most PJIs (84%) were treated with an adequate or partially adequate antimicrobial regimen. Recurrence-free survival was observed in 51.5% of PJI episodes after 24 months of follow-up. The risk of treatment failure was significantly higher for PJI treated with a surgical strategy other than that recommended (hazard ratio, 2.34; 95% confidence interval, 1.10-4.70; P = .01) and for PJIs treated with antibiotics not corresponding to recommendations (hazard ratio, 3.45; confidence interval, 1.50-7.60; P = .002). Other risk factors associated with lack of healing were a high infection score at the time of diagnosis (hazard ratio, 1.29; 95% confidence interval, 1.10-1.40; P < .001) and presence of a sinus tract (hazard ratio, 2.35; 95% confidence interval, 1.10-5.0; P = .02). CONCLUSIONS: Our study demonstrates the value of current treatment recommendations. Inappropriate choice of conservative surgical strategies (such as debridement and retention) and inadequate antibiotic treatment are associated with failure.
Resumo:
OBJECTIVE: Insulin-like growth factor-I (IGF-I) is critically involved in the control of cartilage matrix metabolism. It is well known that IGF-binding protein-3 (IGFBP-3) is increased during osteoarthritis (OA), but its function(s) is not known. In other cells, IGFBP-3 can regulate IGF-I action in the extracellular environment and can also act independently inside the cell; this includes transcriptional gene control in the nucleus. These studies were undertaken to localize IGFBP-3 in human articular cartilage, particularly within cells. DESIGN: Cartilage was dissected from human femoral heads derived from arthroplasty for OA, and OA grade assessed by histology. Tissue slices were further characterized by extraction and assay of IGFBPs by IGF ligand blot (LB) and by enzyme-linked immunosorbent assay (ELISA). Immunohistochemistry (IHC) for IGF-I and IGFBP-3 was performed on cartilage from donors with mild, moderate and severe OA. Indirect fluorescence and immunogold-labeling IHC studies were included. RESULTS: LBs of chondrocyte lysates showed a strong signal for IGFBP-3. IHC of femoral cartilage sections at all OA stages showed IGF-I and IGFBP-3 matrix stain particularly in the top zones, and closely associated with most cells. A prominent perinuclear/nuclear IGFBP-3 signal was seen. Controls using non-immune sera or antigen-blocked antibody showed negative or strongly reduced stain. In frozen sections of human ankle cartilage, immunofluorescent IGFBP-3 stain co-localized with the nuclear 4',6-diamidino-2-phenyl indole (DAPI) stain in greater than 90% of the cells. Immunogold IHC of thin sections and transmission electron immunogold microscopy of ultra-thin sections showed distinct intra-nuclear staining. CONCLUSIONS: IGFBP-3 in human cartilage is located in the matrix and within chondrocytes in the cytoplasm and nuclei. This new finding indicates that the range of IGFBP-3 actions in articular cartilage is likely to include IGF-independent roles and opens the door to studies of its nuclear actions, including the possible regulation of hormone receptors or transcriptional complexes to control gene action.
Resumo:
Blood perfusion to the femoral head might be endangered during the surgical approach or the preparation of the femoral head or both in hip resurfacing arthroplasty. The contribution of the intramedullary blood supply to the femoral head in osteoarthritis is questionable. Therefore, the contribution of the extraosseous blood supply to osteoarthritic femoral heads was measured intraoperatively to question if there is measurable blood flow between the epiphysis and metaphysis in osteoarthritic hips in case of extraosseus vessel damage. At defined points during surgery we acquired the epiphyseal and metaphyseal femoral head perfusion by high-energy laser Doppler flowmetry. Complete femoral neck osteotomy sparing the retinacular vessels to simulate intraosseous blood disruption showed unchanged epiphyseal blood flow compared to initial measurement after capsulotomy. The pulsatile signal disappeared after transection of the retinacular vessels. Based on these acute measurements, we conclude intramedullary blood vessels to the femoral head do not provide measurable blood supply to the epiphysis once the medial femoral circumflex artery or the retinacular vessels have been damaged. We recommend the use of a safe surgical approach for hip resurfacing and careful implantation of the femoral component to respect blood supply to the femoral head and neck region in hip resurfacing arthroplasty.