181 resultados para ADVERSE DRUG EVENTS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Anthracyclines are used in over 50% of childhood cancer treatment protocols, but their clinical usefulness is limited by anthracycline-induced cardiotoxicity (ACT) manifesting as asymptomatic cardiac dysfunction and congestive heart failure in up to 57% and 16% of patients, respectively. Candidate gene studies have reported genetic associations with ACT, but these studies have in general lacked robust patient numbers, independent replication or functional validation. Thus, the individual variability in ACT susceptibility remains largely unexplained. We performed a genome-wide association study in 280 patients of European ancestry treated for childhood cancer, with independent replication in similarly treated cohorts of 96 European and 80 non-European patients. We identified a nonsynonymous variant (rs2229774, p.Ser427Leu) in RARG highly associated with ACT (P = 5.9 × 10(-8), odds ratio (95% confidence interval) = 4.7 (2.7-8.3)). This variant alters RARG function, leading to derepression of the key ACT genetic determinant Top2b, and provides new insight into the pathophysiology of this severe adverse drug reaction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background Conflicting evidence exists on the efficacy and safety of bivalirudin administered as part of percutaneous coronary intervention (PCI) in patients with an acute coronary syndrome. Methods We randomly assigned 7213 patients with an acute coronary syndrome for whom PCI was anticipated to receive either bivalirudin or unfractionated heparin. Patients in the bivalirudin group were subsequently randomly assigned to receive or not to receive a post-PCI bivalirudin infusion. Primary outcomes for the comparison between bivalirudin and heparin were the occurrence of major adverse cardiovascular events (a composite of death, myocardial infarction, or stroke) and net adverse clinical events (a composite of major bleeding or a major adverse cardiovascular event). The primary outcome for the comparison of a post-PCI bivalirudin infusion with no post-PCI infusion was a composite of urgent target-vessel revascularization, definite stent thrombosis, or net adverse clinical events. Results The rate of major adverse cardiovascular events was not significantly lower with bivalirudin than with heparin (10.3% and 10.9%, respectively; relative risk, 0.94; 95% confidence interval [CI], 0.81 to 1.09; P=0.44), nor was the rate of net adverse clinical events (11.2% and 12.4%, respectively; relative risk, 0.89; 95% CI, 0.78 to 1.03; P=0.12). Post-PCI bivalirudin infusion, as compared with no infusion, did not significantly decrease the rate of urgent target-vessel revascularization, definite stent thrombosis, or net adverse clinical events (11.0% and 11.9%, respectively; relative risk, 0.91; 95% CI, 0.74 to 1.11; P=0.34). Conclusions In patients with an acute coronary syndrome, the rates of major adverse cardiovascular events and net adverse clinical events were not significantly lower with bivalirudin than with unfractionated heparin. The rate of the composite of urgent target-vessel revascularization, definite stent thrombosis, or net adverse clinical events was not significantly lower with a post-PCI bivalirudin infusion than with no post-PCI infusion. (Funded by the Medicines Company and Terumo Medical; MATRIX ClinicalTrials.gov number, NCT01433627 .).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND The European AIDS Clinical Society (EACS) guidelines are intended for all clinicians involved in the care of HIV-positive persons, and are available in print, online, and as a free App for download for iPhone and Android. GUIDELINE HIGHLIGHTS The 2015 version of the EACS guidelines contains major revisions in all sections; antiretroviral treatment (ART), comorbidities, coinfections and opportunistic diseases. Among the key revisions is the recommendation of ART for all HIV-positive persons, irrespectively of CD4 count, based on the Strategic Timing of AntiRetroviral Treatment (START) study results. The recommendations for the preferred and the alternative ART options have also been revised, and a new section on the use of pre-exposure prophylaxis (PrEP) has been added. A number of new antiretroviral drugs/drug combinations have been added to the updated tables on drug-drug interactions, adverse drug effects, dose adjustment for renal/liver insufficiency and for ART administration in persons with swallowing difficulties. The revisions of the coinfection section reflect the major advances in anti-hepatitis C virus (HCV) treatment with direct-acting antivirals with earlier start of treatment in individuals at increased risk of liver disease progression, and a phasing out of interferon-containing treatment regimens. The section on opportunistic diseases has been restructured according to individual pathogens/diseases and a new overview table has been added on CD4 count thresholds for different primary prophylaxes. CONCLUSIONS The diagnosis and management of HIV infection and related coinfections, opportunistic diseases and comorbidities continue to require a multidisciplinary effort for which the 2015 version of the EACS guidelines provides an easily accessable and updated overview.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Anticoagulation is required during transcatheter aortic valve replacement (TAVR) procedures. Although an optimal regimen has not been determined, heparin is mainly used. Direct thrombin inhibition with bivalirudin may be an effective alternative to heparin as the procedural anticoagulant agent in this setting. OBJECTIVES The goal of this study was to determine whether bivalirudin offers an alternative to heparin as the procedural anticoagulant agent in patients undergoing TAVR. METHODS A total of 802 patients with aortic stenosis were randomized to undergo transfemoral TAVR with bivalirudin versus unfractionated heparin during the procedure. The 2 primary endpoints were major bleeding within 48 h or before hospital discharge (whichever occurred first) and 30-day net adverse clinical events, defined as the combination of major adverse cardiovascular events (all-cause mortality, myocardial infarction, or stroke) and major bleeding. RESULTS Anticoagulation with bivalirudin versus heparin did not meet superiority because it did not result in significantly lower rates of major bleeding at 48 h (6.9% vs. 9.0%; relative risk: 0.77; 95% confidence interval [CI]: 0.48 to 1.23; p = 0.27) or net adverse cardiovascular events at 30 days (14.4% vs. 16.1%; relative risk: 0.89; 95% CI: 0.64 to 1.24; risk difference: -1.72; 95% CI: -6.70 to 3.25; p = 0.50); regarding the latter, the prespecified noninferiority hypothesis was met (pnoninferiority < 0.01). Rates of major adverse cardiovascular events at 48 h were not significantly different (3.5% vs. 4.8%; relative risk: 0.73; 95% CI: 0.37 to 1.43; p = 0.35). At 48 h, the bivalirudin group had significantly fewer myocardial infarctions but more acute kidney injury events than the heparin group; at 30 days, these differences were no longer significant. CONCLUSIONS In this randomized trial of TAVR procedural pharmacotherapy, bivalirudin did not reduce rates of major bleeding at 48 h or net adverse cardiovascular events within 30 days compared with heparin. Although superiority was not shown, the noninferiority hypothesis was met with respect to the latter factor. Given the lower cost, heparin should remain the standard of care, and bivalirudin can be an alternative anticoagulant option in patients unable to receive heparin in TAVR. (International, Multi-center, Open-label, Randomized Controlled Trial in Patients Undergoing TAVR to Determine the Treatment Effect [Both Safety and Efficacy] of Using Bivalirudin Instead of UFH [BRAVO-2/3]; NCT01651780).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND The distribution of thrombus-containing lesions (TCLs) in an all-comer population admitted with a heterogeneous clinical presentation (stable, ustable angina, or an acute coronary syndrome) and treated with percutaneous coronary intervention is yet unclear, and the long-term prognostic implications are still disputed. This study sought to assess the distribution and prognostic implications of coronary thrombus, detected by coronary angiography, in a population recruited in all-comer percutaneous coronary intervention trials. METHODS AND RESULTS Patient-level data from 3 contemporary coronary stent trials were pooled by an independent academic research organization (Cardialysis, Rotterdam, the Netherlands). Clinical outcomes in terms of major adverse cardiac events (major adverse cardiac events, a composite of death, myocardial infarction, and repeat revascularization), death, myocardial infarction, and repeated revascularization were compared between patients with and without angiographic TCL. Preprocedural TCL was present in 257 patients (5.8%) and absent in 4193 (94.2%) patients. At 3-year follow-up, there was no difference for major adverse cardiac events (25.3 versus 25.4%; P=0.683); all-cause death (7.4 versus 6.8%; P=0.683); myocardial infarction (5.8 versus 6.0%; P=0.962), and any revascularizations (17.5 versus 17.7%; P=0.822) between patients with and without TCL. The comparison of outcomes in groups weighing the jeopardized myocardial by TCL also did not show a significant difference. TCL were seen more often in the first 2 segments of the right (43.6%) and left anterior descending (36.8%) coronary arteries. The association of TCL and bifurcation lesions was present in 40.1% of the prespecified segments. CONCLUSIONS TCL involved mainly the proximal coronary segments and did not have any effect on clinical outcomes. A more detailed thrombus burden quantification is required to investigate its prognostic implications. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifiers: NCT00114972, NCT01443104, NCT00617084.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The coronary collateral circulation provides an alternative source of blood supply to myocardium jeopardised by ischaemia. Collaterals enlarge with obstructive coronary artery disease to allow bulk flow, but blood flow deliverable by the native, pre-formed collateral extent can already be sizeable. Genetic determinants contribute significantly to the wide variability observed in both native collateral extent and its capacity to enlarge, and the severity of the coronary stenosis is the most significant environmental determinant for collateral enlargement. The protective effect of a well-developed coronary collateral circulation translates into relevant improvements in all-cause and cardiac mortality in the acute and chronic phases of coronary artery disease, as well as into a reduction of future adverse cardiovascular events.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIMS Bindarit (BND) is a selective inhibitor of monocyte chemotactic protein-1 (MCP-1/CCL2), which plays an important role in generating intimal hyperplasia. Our aim was to explore the efficacy and safety of bindarit in preventing restenosis following percutaneous coronary intervention. METHODS AND RESULTS A phase II, double-blind, multicentre randomised trial included 148 patients randomised into three arms (BND 600 mg, n=48; BND 1,200 mg, n=49; PLB, n=51). Bindarit was given following PCI and continued for 180 days. Monthly clinical follow-up and six-month coronary angiography were conducted. The primary endpoint was in-segment late loss; the main secondary endpoints were in-stent late loss and major adverse cardiovascular events. Efficacy analysis was carried out on two populations, ITT and PP. There were no significant differences in the baseline characteristics among the three treatment groups. In-segment and in-stent late loss at six months in BND 600, BND 1,200 and PLB were: (ITT 0.54 vs. 0.52 vs. 0.72; p=0.21), (PP 0.46 vs. 0.53 vs. 0.72; p=0.12) and (ITT 0.74 vs. 0.74 vs. 1.05; p=0.01), (PP 0.66 vs. 0.73 vs. 1.06; p=0.003), respectively. The MACE rates at nine months among treatment groups were 20.8% vs. 28.6% vs. 25.5% (p=0.54), respectively. CONCLUSIONS This was a negative study with the primary endpoint not being met. However, significant reduction in the in-stent late loss suggests that bindarit probably exerts a favourable action on the vessel wall following angioplasty. Bindarit was well tolerated with a compliance rate of over 90%. A larger study utilising a loading dose and targeting a specific patient cohort may demonstrate more significant results.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND: Antiretroviral therapy (ART) decreases morbidity and mortality in HIV-infected patients but is associated with considerable adverse events (AEs). METHODS: We examined the effect of AEs to ART on mortality, treatment modifications and drop-out in the Swiss HIV Cohort Study. A cross-sectional evaluation of prevalence of 13 clinical and 11 laboratory parameters was performed in 1999 in 1,078 patients on ART. AEs were defined as abnormalities probably or certainly related to ART. A score including the number and severity of AEs was defined. The subsequent progression to death, drop-out and treatment modification due to intolerance were evaluated according to the baseline AE score and characteristics of individual AEs. RESULTS: Of the 1,078 patients, laboratory AEs were reported in 23% and clinical AEs in 45%. During a median follow up of 5.9 years, laboratory AEs were associated with higher mortality with an adjusted hazard ratio (HR) of 1.3 (95% confidence interval [CI] 1.2-1.5; P < 0.001) per score point. For clinical AEs no significant association with increased mortality was found. In contrast, an increasing score for clinical AEs (HR 1.11,95% CI 1.04-1.18; P = 0.002), but not for laboratory AEs (HR 1.07, 95% CI 0.97-1.17; P = 0.17), was associated with antiretroviral treatment modification. AEs were not associated with a higher drop-out rate. CONCLUSIONS: The burden of laboratory AEs to antiretroviral drugs is associated with a higher mortality. Physicians seem to change treatments to relieve clinical symptoms, while accepting laboratory AEs. Minimizing laboratory drug toxicity seems warranted and its influence on survival should be further evaluated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE To develop a score predicting the risk of adverse events (AEs) in pediatric patients with cancer who experience fever and neutropenia (FN) and to evaluate its performance. PATIENTS AND METHODS Pediatric patients with cancer presenting with FN induced by nonmyeloablative chemotherapy were observed in a prospective multicenter study. A score predicting the risk of future AEs (ie, serious medical complication, microbiologically defined infection, radiologically confirmed pneumonia) was developed from a multivariate mixed logistic regression model. Its cross-validated predictive performance was compared with that of published risk prediction rules. Results An AE was reported in 122 (29%) of 423 FN episodes. In 57 episodes (13%), the first AE was known only after reassessment after 8 to 24 hours of inpatient management. Predicting AE at reassessment was better than prediction at presentation with FN. A differential leukocyte count did not increase the predictive performance. The score predicting future AE in 358 episodes without known AE at reassessment used the following four variables: preceding chemotherapy more intensive than acute lymphoblastic leukemia maintenance (weight = 4), hemoglobin > or = 90 g/L (weight = 5), leukocyte count less than 0.3 G/L (weight = 3), and platelet count less than 50 G/L (weight = 3). A score (sum of weights) > or = 9 predicted future AEs. The cross-validated performance of this score exceeded the performance of published risk prediction rules. At an overall sensitivity of 92%, 35% of the episodes were classified as low risk, with a specificity of 45% and a negative predictive value of 93%. CONCLUSION This score, based on four routinely accessible characteristics, accurately identifies pediatric patients with cancer with FN at risk for AEs after reassessment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We investigated the incidence of cardiac adverse events in patients with early breast cancer in the Herceptin Adjuvant (HERA) trial who were treated with 1 year of trastuzumab after completion of (neo)adjuvant chemotherapy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Transcatheter aortic valve implantation (TAVI) is a treatment option for high-risk patients with severe aortic stenosis. Previous reports focused on a single device or access site, whereas little is known of the combined use of different devices and access sites as selected by the heart team. The purpose of this study is to investigate clinical outcomes of TAVI using different devices and access sites. Methods A consecutive cohort of 200 patients underwent TAVI with the Medtronic CoreValve Revalving system (Medtronic Core Valve LLC, Irvine, CA; n = 130) or the Edwards SAPIEN valve (Edwards Lifesciences LLC, Irvine, CA; n = 70) implanted by either the transfemoral or transapical access route. Results Device success and procedure success were 99% and 95%, respectively, without differences between devices and access site. All-cause mortality was 7.5% at 30 days, with no differences between valve types or access sites. Using multivariable analysis, low body mass index (<20 kg/m2) (odds ratio [OR] 6.6, 95% CI 1.5-29.5) and previous stroke (OR 4.4, 95% CI 1.2-16.8) were independent risk factors for short-term mortality. The VARC-defined combined safety end point occurred in 18% of patients and was driven by major access site complications (8.0%), life-threatening bleeding (8.5%) or severe renal failure (4.5%). Transapical access emerged as independent predictor of adverse outcome for the Valve Academic Research Consortium–combined safety end point (OR 3.3, 95% CI 1.5-7.1). Conclusion A heart team–based selection of devices and access site among patients undergoing TAVI resulted in high device and procedural success. Low body mass index and history of previous stroke were independent predictors of mortality. Transapical access emerged as a risk factor for the Valve Academic Research Consortium–combined safety end point.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Epidemiological evidence has suggested a link between beta2-agonists and increased asthma mortality. There has been much debate about possible causal links for this association, and whether regular (daily) long-acting beta2-agonists are safe. This is an updated systematic review.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: Previous analyses of adjuvant studies of aromatase inhibitors versus tamoxifen, including the Breast International Group (BIG) 1-98 study, have suggested a small numerical excess of cardiac adverse events (AEs) on aromatase inhibitors, a reduction in the incidence of hypercholesterolemia on tamoxifen, and significantly higher incidence of thromboembolic AEs on tamoxifen. The purpose of the present study is to provide detailed updated information on these AEs in BIG 1-98. PATIENTS AND METHODS: Eight thousand twenty-eight postmenopausal women with receptor-positive early breast cancer were randomly assigned (double-blind) between March 1998 and May 2003 to receive 5 years of adjuvant endocrine therapy with letrozole, tamoxifen, or a sequence of these agents. Seven thousand nine hundred sixty-three patients who actually received therapy are included in this safety analysis, which focuses on cardiovascular events. AE recording ceased 30 days after therapy completion (or after switch on the sequential arms). RESULTS: Baseline comorbidities were balanced. At a median follow-up time of 30.1 months, we observed similar overall incidence of cardiac AEs (letrozole, 4.8%; tamoxifen, 4.7%), more grade 3 to 5 cardiac AEs on letrozole (letrozole, 2.4%; tamoxifen, 1.4%; P = .001)--an excess only partially attributable to prior hypercholesterolemia--and more overall (tamoxifen, 3.9%; letrozole, 1.7%; P < .001) and grade 3 to 5 thromboembolic AEs on tamoxifen (tamoxifen, 2.3%; letrozole, 0.9%; P < .001). There was no significant difference between tamoxifen and letrozole in incidence of hypertension or cerebrovascular events. CONCLUSION: The present safety analysis, limited to cardiovascular AEs in BIG 1-98, documents a low overall incidence of cardiovascular AEs, which differed between treatment arms.