104 resultados para initial chamber
Resumo:
BACKGROUND Several treatment strategies are available for adults with advanced-stage Hodgkin's lymphoma, but studies assessing two alternative standards of care-increased dose bleomycin, etoposide, doxorubicin, cyclophosphamide, vincristine, procarbazine, and prednisone (BEACOPPescalated), and doxorubicin, bleomycin, vinblastine, and dacarbazine (ABVD)-were not powered to test differences in overall survival. To guide treatment decisions in this population of patients, we did a systematic review and network meta-analysis to identify the best initial treatment strategy. METHODS We searched the Cochrane Library, Medline, and conference proceedings for randomised controlled trials published between January, 1980, and June, 2013, that assessed overall survival in patients with advanced-stage Hodgkin's lymphoma given BEACOPPbaseline, BEACOPPescalated, BEACOPP variants, ABVD, cyclophosphamide (mechlorethamine), vincristine, procarbazine, and prednisone (C[M]OPP), hybrid or alternating chemotherapy regimens with ABVD as the backbone (eg, COPP/ABVD, MOPP/ABVD), or doxorubicin, vinblastine, mechlorethamine, vincristine, bleomycin, etoposide, and prednisone combined with radiation therapy (the Stanford V regimen). We assessed studies for eligibility, extracted data, and assessed their quality. We then pooled the data and used a Bayesian random-effects model to combine direct comparisons with indirect evidence. We also reconstructed individual patient survival data from published Kaplan-Meier curves and did standard random-effects Poisson regression. Results are reported relative to ABVD. The primary outcome was overall survival. FINDINGS We screened 2055 records and identified 75 papers covering 14 eligible trials that assessed 11 different regimens in 9993 patients, providing 59 651 patient-years of follow-up. 1189 patients died, and the median follow-up was 5·9 years (IQR 4·9-6·7). Included studies were of high methodological quality, and between-trial heterogeneity was negligible (τ(2)=0·01). Overall survival was highest in patients who received six cycles of BEACOPPescalated (HR 0·38, 95% credibility interval [CrI] 0·20-0·75). Compared with a 5 year survival of 88% for ABVD, the survival benefit for six cycles of BEACOPPescalated is 7% (95% CrI 3-10)-ie, a 5 year survival of 95%. Reconstructed individual survival data showed that, at 5 years, BEACOPPescalated has a 10% (95% CI 3-15) advantage over ABVD in overall survival. INTERPRETATION Six cycles of BEACOPPescalated significantly improves overall survival compared with ABVD and other regimens, and thus we recommend this treatment strategy as standard of care for patients with access to the appropriate supportive care.
Resumo:
Lacebacks may be used to limit unwanted incisor proclination during initial orthodontic alignment; however, their use has not met with universal approval. This systematic review aims to appraise the evidence in relation to the effectiveness of lacebacks in controlling incisor position during initial alignment. Electronic database searches of published literature (MEDLINE via Ovid, Cochrane Central Register of Controlled Trials, LILACS, and IBECS) and unpublished literature were performed. Search terms used included randomized controlled trial, controlled clinical trial, random allocation, double blind method, orthodontics, and laceback. Data were extracted using custom forms. Risk of bias assessment was made using the Cochrane Collaboration risk of bias tool. The quality of the evidence was also assessed using GRADE. Mean differences in incisor inclination and antero-posterior changes in incisor and molar position during alignment were calculated. Two studies involving 97 participants were found to be at low risk of bias and were included in the quantitative synthesis. The random effects meta-analysis demonstrated that the use of lacebacks was associated with 0.5 mm greater posterior movement of the incisors during alignment; this finding was of limited clinical importance and statistically non-significant [95 per cent confidence interval (CI): -1.25, 0.25, P = 0.19]. Little difference (0.46 mm) was also found between laceback and non-laceback groups with regards to mesial molar movement (95 per cent CI: -0.33, 1.24, P = 0.26). According to the GRADE assessment, the overall quality of evidence relating to the use of lacebacks was high. There is no evidence to support the use of lacebacks for the control of the sagittal position of the incisors during initial orthodontic alignment.
Resumo:
OBJECTIVE The Coherex-EU Study evaluated the safety and efficacy of PFO closure utilizing novel in-tunnel PFO closure devices. BACKGROUND Transcatheter closure of patent foramen ovale (PFO) followed the development of transcatheter closure devices designed to patch atrial septal defects (ASDs). The Coherex FlatStent™ and FlatStent™ EF devices were designed specifically to treat PFO anatomy. METHODS A total of 95 patients with a clinical indication for PFO closure were enrolled in a prospective, multicenter first in man study at six clinical sites. Thirty-six patients received the first-generation FlatStent study device, and 57 patients received the second-generation FlatStent EF study device, which was modified based on clinical experience during the first 38 cases. Two patients enrolled to receive the first generation did not receive a device. RESULTS At 6 months post-procedure, 45% (17/38) of the intention-to-treat (ITT) cohort receiving the first-generation FlatStent device had complete closure, 26% (10/38) had a trivial residual shunt, and 29% (11/38) had a moderate to large residual shunt. In the ITT cohort receiving the second-generation FlatStent EF device, 76% (43/57) had complete closure, 12% (7/57) had a trivial shunt, and 12% had a moderate to large shunt. Five major adverse events occurred, all without sequelae. CONCLUSION This initial study of the Coherex FlatStent/FlatStent EF PFO Closure System demonstrated the potential for in-tunnel PFO closure. The in-tunnel Coherex FlatStent EF may offer an alternative to septal repair devices for PFO closure in appropriately selected patients; however, further investigation will be necessary to establish the best use of this device.
Resumo:
Abstract Inhalation of ambient air particles or engineered nanoparticles (NP) handled as powders, dispersions or sprays in industrial processes and contained in consumer products pose a potential and largely unknown risk for incidental exposure. For efficient, economical and ethically sound evaluation of health hazards by inhaled nanomaterials, animal-free and realistic in vitro test systems are desirable. The new Nano Aerosol Chamber for in-vitro Toxicity studies (NACIVT) has been developed and fully characterized regarding its performance. NACIVT features a computer-controlled temperature and humidity conditioning, preventing cellular stress during exposure and allowing long-term exposures. Airborne NP are deposited out of a continuous air stream simultaneously on up to 24 cell cultures on Transwell® inserts, allowing high-throughput screening. In NACIVT, polystyrene as well as silver particles were deposited uniformly and efficiently on all 24 Transwell® inserts. Particle-cell interaction studies confirmed that deposited particles reach the cell surface and can be taken up by cells. As demonstrated in control experiments, there was no evidence for any adverse effects on human bronchial epithelial cells (BEAS-2B) due to the exposure treatment in NACIVT. The new, fully integrated and transportable deposition chamber NACIVT provides a promising tool for reliable, acute and sub-acute dose-response studies of (nano)particles in air-exposed tissues cultured at the air-liquid interface.
Resumo:
BACKGROUND Epidemiological studies show that elevated levels of particulate matter in ambient air are highly correlated with respiratory and cardiovascular diseases. Atmospheric particles originate from a large number of sources and have a highly complex and variable composition. An assessment of their potential health risks and the identification of the most toxic particle sources would require a large number of investigations. Due to ethical and economic reasons, it is desirable to reduce the number of in vivo studies and to develop suitable in vitro systems for the investigation of cell-particle interactions. METHODS We present the design of a new particle deposition chamber in which aerosol particles are deposited onto cell cultures out of a continuous air flow. The chamber allows for a simultaneous exposure of 12 cell cultures. RESULTS Physiological conditions within the deposition chamber can be sustained constantly at 36-37°C and 90-95% relative humidity. Particle deposition within the chamber and especially on the cell cultures was determined in detail, showing that during a deposition time of 2 hr 8.4% (24% relative standard deviation) of particles with a mean diameter of 50 nm [mass median diameter of 100 nm (geometric standard deviation 1.7)] are deposited on the cell cultures, which is equal to 24-34% of all charged particles. The average well-to-well variability of particles deposited simultaneously in the 12 cell cultures during an experiment is 15.6% (24.7% relative standard deviation). CONCLUSIONS This particle deposition chamber is a new in vitro system to investigate realistic cell-particle interactions at physiological conditions, minimizing stress on the cell cultures other than from deposited particles. A detailed knowledge of particle deposition characteristics on the cell cultures allows evaluating reliable dose-response relationships. The compact and portable design of the deposition chamber allows for measurements at any particle sources of interest.
Resumo:
Information about fluid evolution and solute transport in a low-permeability metamorphic rock sequence has been obtained by comparing chloride concentrations and chlorine isotope ratios of pore water, groundwater, and fluid inclusions. The similarity of d37Cl values in fluid inclusions and groundwater suggests a closed-system evolution during the metamorphic overprint, and signatures established at this time appear to form the initial conditions for chloride transport after exhumation of the rock sequence.
Resumo:
AIM: To evaluate the influence of locally active Crohn's disease on systemic small-bowel motility in patients with chronic Crohn's disease compared to healthy individuals. MATERIAL AND METHODS: Fifteen healthy individuals (11 men, four women; mean age 37 years) and 20 patients with histopathologically proven active (n = 15; 10 women, 5 men; mean age 45 years) or chronic (n = 5; four women, one man; mean age 48 years) Crohn's disease were included in this institutional review board-approved, retrospective study. Magnetic resonance imaging (MRI; 1.5 T) was performed after standardized preparation. Two-dimensional (2D) cine sequences for motility acquisition were performed in apnoea (27 s). Motility assessment was performed using dedicated software in three randomly chosen areas of the small-bowel outside known Crohn's disease-affected hotspots. The main quantitative characteristics (frequency, amplitude, occlusion rate) were compared using Student's t-test and one-way analysis of variance (ANOVA). RESULTS: Three randomly chosen segments were analysed in each participant. Patients with active Crohn's disease had significantly (p < 0.05) reduced contraction frequencies (active Crohn's disease: 2.86/min; chronic: 4.14/min; healthy: 4.53/min) and luminal occlusion rates (active: 0.43; chronic: 0.70; healthy: 0.73) compared to healthy individuals and patients with chronic Crohn's disease. Contraction amplitudes were significantly reduced during active Crohn's disease (6.71 mm) compared to healthy participants (10.14 mm), but this only reached borderline significance in comparison to chronic Crohn's disease (8.87 mm). Mean bowel lumen diameter was significantly (p = 0.04) higher in patients with active Crohn's disease (16.91 mm) compared to healthy participants (14.79 mm) but not in comparison to patients with chronic Crohn's disease (13.68). CONCLUSION: The findings of the present study suggest that local inflammatory activity of small-bowel segments in patients with active Crohn's disease alters small-bowel motility in distant, non-affected segments. The motility patterns revealed reduced contraction-wave frequencies, amplitudes, and decreased luminal occlusion rates. Thus evaluation of these characteristics potentially helps to differentiate between chronic and active Crohn's disease.
Resumo:
BACKGROUND We aimed to assess whether elderly patients with acute venous thromboembolism (VTE) receive recommended initial processes of care and to identify predictors of process adherence. METHODS We prospectively studied in- and outpatients aged ≥65 years with acute symptomatic VTE in a multicenter cohort study from nine Swiss university- and non-university hospitals between September 2009 and March 2011. We systematically assessed whether initial processes of care, which are recommended by the 2008 American College of Chest Physicians guidelines, were performed in each patient. We used multivariable logistic models to identify patient factors independently associated with process adherence. RESULTS Our cohort comprised 950 patients (mean age 76 years). Of these, 86% (645/750) received parenteral anticoagulation for ≥5 days, 54% (405/750) had oral anticoagulation started on the first treatment day, and 37% (274/750) had an international normalized ratio (INR) ≥2 for ≥24 hours before parenteral anticoagulation was discontinued. Overall, 35% (53/153) of patients with cancer received low-molecular-weight heparin monotherapy and 72% (304/423) of patients with symptomatic deep vein thrombosis were prescribed compression stockings. In multivariate analyses, symptomatic pulmonary embolism, hospital-acquired VTE, and concomitant antiplatelet therapy were associated with a significantly lower anticoagulation-related process adherence. CONCLUSIONS Adherence to several recommended processes of care was suboptimal in elderly patients with VTE. Quality of care interventions should particularly focus on processes with low adherence, such as the prescription of continued low-molecular-weight heparin therapy in patients with cancer and the achievement of an INR ≥2 for ≥24 hours before parenteral anticoagulants are stopped.
Resumo:
Systematic reviews of well-designed trials constitute a high level of scientific evidence and are important for medical decision making. Meta-analysis facilitates integration of the evidence using a transparent and systematic approach, leading to a broader interpretation of treatment effectiveness and safety than can be attained from individual studies. Traditional meta-analyses are limited to comparing just 2 interventions concurrently and cannot combine evidence concerning multiple treatments. A relatively recent extension of the traditional meta-analytical approach is network meta-analysis, which allows, under certain assumptions, the quantitative synthesis of all evidence under a unified framework and across a network of all eligible trials. Network meta-analysis combines evidence from direct and indirect information via common comparators; interventions can therefore be ranked in terms of the analyzed outcome. In this article, the network meta-analysis approach is introduced in a nontechnical manner using a worked example on the treatment effectiveness of conventional and self-ligating appliances.