82 resultados para heterojunction semiconductor devices
Resumo:
BACKGROUND Paediatric supraglottic airway devices AmbuAura-i and Air-Q were designed as conduits for tracheal intubation. Although fibreoptic-guided intubation has proved successful, blind intubation as a rescue technique has never been evaluated. OBJECTIVE Evaluation of blind intubation through AmbuAura-i and Air-Q. On the basis of fibreoptic view data, we hypothesised that the success rate with the AmbuAura-i would be higher than with the Air-Q. DESIGN A prospective, randomised controlled trial with institutional review board (IRB) approval and written informed consent. SETTING University Childrens' Hospital; September 2012 to July 2014. PATIENTS Eighty children, American Society of Anesthesiologists (ASA) class I to III, weight 5 to 50 kg. INTERVENTIONS Tracheal intubation was performed through the randomised device with the tip of a fibrescope placed inside and proximal to the tip of the tracheal tube. This permitted sight of tube advancement, but without fibreoptic guidance (visualised blind intubation). MAIN OUTCOME MEASURES Primary outcome was successfully visualised blind intubation; secondary outcomes included supraglottic airway device success, insertion times, airway leak pressure, fibreoptic view and adverse events. RESULTS Personal data did not differ between groups. In contrast to our hypothesis, blind intubation was possible in 15% with the Air-Q and in 3% with the AmbuAura-i [95% confidence interval (95% CI) 6 to 31 vs. 0 to 13%; P = 0.057]. First attempt supraglottic airway device insertion success rates were 95% (Air-Q) and 100% (AmbuAura-i; 95% CI 83 to 99 vs. 91 to 100; P = 0.49). Median leak pressures were 18 cmH2O (Air-Q) and 17 cmH2O [AmbuAura-i; interquartile range (IQR) 14 to 18 vs. 14 to 19 cmH2O; P = 0.66]. Air-Q insertion was slower (27 vs. 19 s, P < 0.001). There was no difference in fibreoptic view, or adverse events (P > 0.05). In one child (Air-Q size 1.5, tube size 3.5), the tube dislocated during device removal. CONCLUSION Ventilation with both devices is reliable, but success of blind intubation is unacceptably low and cannot be recommended for elective or rescue purposes. If intubation through a paediatric supraglottic airway device is desired, we suggest that fibreoptic guidance is used. TRIAL REGISTRATION Clinicaltrials.gov identifier: NCT01692522.
Resumo:
Currently, most cosmic ray data are obtained by detectors on satellites, aircraft, high-altitude balloons and ground (neutron monitors). In our work, we examined whether Liulin semiconductor spectrometers (simple silicon planar diode detectors with spectrometric properties) located at high mountain observatories could contribute new information to the monitoring of cosmic rays by analyzing data from selected solar events between 2005 and 2013. The decision thresholds and detection limits of these detectors placed at Jungfraujoch (Switzerland; 3475 m a.s.l.; vertical cut-off rigidity 4.5 GV) and Lomnicky stıt (Slovakia; 2633 m a.s.l.; vertical cut-off rigidity 3.84 GV) highmountain observatories were determined. The data showed that only the strongest variations of the cosmic ray flux in this period were detectable. The main limitation in the performance of these detectors is their small sensitive volume and low sensitivity of the PIN photodiode to neutrons.
Resumo:
Several recent prospective randomized controlled trials of endovascular stroke therapy using latest generation thrombectomy devices, so called stent-retrievers, have shown significantly improved clinical outcome compared to the standard treatment with intra-venous thrombolysis using r-tPA alone. Despite some differences in inclusion criteria between these studies, all required non-invasive vessel imaging to proof occlusion of a major brain supplying vessel. Furthermore, in most studies additional imaging techniques were used to exclude patients with already established large cerebral infarction or unfavorable collateral or penumbral status. Patients with small infarct volume, severe neurological deficits and in whom thrombectomy can be initiated within the first 6 hours after symptom onset seem to benefit the most. Therefore, mechanical thrombectomy using stent-retrievers in addition to intra-venous thrombolysis is recommended for the treatment of acute ischemic stroke with proven major vessel occlusion in the anterior circulation.
Resumo:
OBJECTIVES The aims of the present study in Swiss dental practices were 1) to provide an update on the prevalence of different magnification devices, 2) to examine the relationship between self-assessed and objectively measured visual acuity, and 3) to evaluate the visual performance of dentists in the individually optimized clinical situation of their respective practices. METHODS AND MATERIALS Sixty-nine dentists from 40 randomly selected private practices (n=20, <40 years; n=49, ≥40 years) participated in the study. A questionnaire was provided to evaluate the self-assessed near visual acuity and the experience with magnification devices. The objective near visual acuity was measured under standardized conditions on a negatoscope. The clinical situation, including the use of habitual optical aids, was evaluated with visual tests on a phantom head. RESULTS A total of 64% of the dentists owned a dental loupe: 45% Galilean loupes, 16% Keplerian loupes, and 3% single lens loupes. In total, 19% of the questioned dentists owned a microscope in addition to the loupes. The correlation between the self-assessed and the objective visual performance of the dentists was weak (Spearman rank correlation coefficient=0.25). In the habitual clinical situation, magnification devices (p=0.03) and the dentist's age (p=0.0012) had a significant influence on the visual performance. CONCLUSIONS Many dentists were not aware of their visual handicaps. Optical aids such as loupes or microscopes should be used early enough to compensate for individual or age-related visual deficiencies.
Resumo:
Web surveys are becoming increasingly popular in survey research including stated preference surveys. Compared with face-to-face, telephone and mail surveys, web surveys may contain a different and new source of measurement error and bias: the type of device that respondents use to answer the survey questions. This is the first study that tests whether the use of mobile devices, tablets or smartphones, affects survey characteristics and stated preferences in a web-based choice experiment. The web survey on expanding renewable energy production in Germany was carried out with 3182 respondents, of which 12% used a mobile device. Propensity score matching is used to account for selection bias in the use of mobile devices for survey completion. We find that mobile device users spent more time than desktop/laptop users to answer the survey. Yet, desktop/laptop users and mobile device users do not differ in acquiescence tendency as an indicator of extreme response patterns. For mobile device users only, we find a negative correlation between screen size and interview length and a positive correlation between screen size and acquiescence tendency. In the choice experiment data, we do not find significant differences in the tendency to choose the status quo option and scale between both subsamples. However, some of the estimates of implicit prices differ, albeit not in a unidirectional fashion. Model results for mobile device users indicate a U-shaped relationship between error variance and screen size. Together, the results suggest that using mobile devices is not detrimental to survey quality.