94 resultados para health failure
Resumo:
BACKGROUND Prostate cancer (PCa) is a very heterogeneous disease with respect to clinical outcome. This study explored differential DNA methylation in a priori selected genes to diagnose PCa and predict clinical failure (CF) in high-risk patients. METHODS A quantitative multiplex, methylation-specific PCR assay was developed to assess promoter methylation of the APC, CCND2, GSTP1, PTGS2 and RARB genes in formalin-fixed, paraffin-embedded tissue samples from 42 patients with benign prostatic hyperplasia and radical prostatectomy specimens of patients with high-risk PCa, encompassing training and validation cohorts of 147 and 71 patients, respectively. Log-rank tests, univariate and multivariate Cox models were used to investigate the prognostic value of the DNA methylation. RESULTS Hypermethylation of APC, CCND2, GSTP1, PTGS2 and RARB was highly cancer-specific. However, only GSTP1 methylation was significantly associated with CF in both independent high-risk PCa cohorts. Importantly, trichotomization into low, moderate and high GSTP1 methylation level subgroups was highly predictive for CF. Patients with either a low or high GSTP1 methylation level, as compared to the moderate methylation groups, were at a higher risk for CF in both the training (Hazard ratio [HR], 3.65; 95% CI, 1.65 to 8.07) and validation sets (HR, 4.27; 95% CI, 1.03 to 17.72) as well as in the combined cohort (HR, 2.74; 95% CI, 1.42 to 5.27) in multivariate analysis. CONCLUSIONS Classification of primary high-risk tumors into three subtypes based on DNA methylation can be combined with clinico-pathological parameters for a more informative risk-stratification of these PCa patients.
Resumo:
Vertebral compression fracture is a common medical problem in osteoporotic individuals. The quantitative computed tomography (QCT)-based finite element (FE) method may be used to predict vertebral strength in vivo, but needs to be validated with experimental tests. The aim of this study was to validate a nonlinear anatomy specific QCT-based FE model by using a novel testing setup. Thirty-seven human thoracolumbar vertebral bone slices were prepared by removing cortical endplates and posterior elements. The slices were scanned with QCT and the volumetric bone mineral density (vBMD) was computed with the standard clinical approach. A novel experimental setup was designed to induce a realistic failure in the vertebral slices in vitro. Rotation of the loading plate was allowed by means of a ball joint. To minimize device compliance, the specimen deformation was measured directly on the loading plate with three sensors. A nonlinear FE model was generated from the calibrated QCT images and computed vertebral stiffness and strength were compared to those measured during the experiments. In agreement with clinical observations, most of the vertebrae underwent an anterior wedge-shape fracture. As expected, the FE method predicted both stiffness and strength better than vBMD (R2 improved from 0.27 to 0.49 and from 0.34 to 0.79, respectively). Despite the lack of fitting parameters, the linear regression of the FE prediction for strength was close to the 1:1 relation (slope and intercept close to one (0.86 kN) and to zero (0.72 kN), respectively). In conclusion, a nonlinear FE model was successfully validated through a novel experimental technique for generating wedge-shape fractures in human thoracolumbar vertebrae.
Resumo:
AIM To assess the long-term success of maxillary fixed retainers, investigate their effect on gingival health, and analyse the survival rate after a mean period of 7 years (minimum 5 years) in retention. SUBJECTS AND METHODS Forty one subjects were included in the study A clinical examination of the upper canine to canine region including gingival index (GI), plaque index, probing depth, and bleeding on probing (BOP) was performed. Intraoral photographs and dental impressions were taken and irregularity index was determined and compared to the values of the immediate post-therapeutic values; failures of retainers were also recorded and analysed. RESULTS The mean observed retention time was 7 years and 5 months. Irregularity index: Changes occurring during retention were statistically different between the lateral incisors bonded to retainers and the canines not bonded to retainers. Only six patients showed changes in irregularity index of the lateral incisors in spite of a retainer in place. Periodontal health: The median value of the GI for all teeth bonded to upper retainers was 1.10 and the median value of the plaque index (PI) was 1.14. PI was not a significant predictor of GI. The overall BOP of the bonded teeth to the retainer for each participant was 22.3 per cent. Failure rate: Twenty-eight out of 41 patients experienced no failure of the upper bonded retainer (68.3 per cent). Detachments were the most frequent incidents. CONCLUSION Although plaque accumulation might be increased in patients with already poor oral hygiene, maxillary bonded retainers caused no significant negative effects on the periodontal health.
Resumo:
OBJECTIVE To determine the effect of nonadherence to antiretroviral therapy (ART) on virologic failure and mortality in naive individuals starting ART. DESIGN Prospective observational cohort study. METHODS Eligible individuals enrolled in the Swiss HIV Cohort Study, started ART between 2003 and 2012, and provided adherence data on at least one biannual clinical visit. Adherence was defined as missed doses (none, one, two, or more than two) and percentage adherence (>95, 90-95, and <90) in the previous 4 weeks. Inverse probability weighting of marginal structural models was used to estimate the effect of nonadherence on viral failure (HIV-1 viral load >500 copies/ml) and mortality. RESULTS Of 3150 individuals followed for a median 4.7 years, 480 (15.2%) experienced viral failure and 104 (3.3%) died, 1155 (36.6%) reported missing one dose, 414 (13.1%) two doses and, 333 (10.6%) more than two doses of ART. The risk of viral failure increased with each missed dose (one dose: hazard ratio [HR] 1.15, 95% confidence interval 0.79-1.67; two doses: 2.15, 1.31-3.53; more than two doses: 5.21, 2.96-9.18). The risk of death increased with more than two missed doses (HR 4.87, 2.21-10.73). Missing one to two doses of ART increased the risk of viral failure in those starting once-daily (HR 1.67, 1.11-2.50) compared with those starting twice-daily regimens (HR 0.99, 0.64-1.54, interaction P = 0.09). Consistent results were found for percentage adherence. CONCLUSION Self-report of two or more missed doses of ART is associated with an increased risk of both viral failure and death. A simple adherence question helps identify patients at risk for negative clinical outcomes and offers opportunities for intervention.
Resumo:
Unrepaired defects in the annulus fibrosus of intervertebral disks are associated with degeneration and persistent back pain. A clinical need exists for a disk repair strategy that can seal annular defects, be easily delivered during surgical procedures, and restore biomechanics with low risk of herniation. Multiple annulus repair strategies were developed using poly(trimethylene carbonate) scaffolds optimized for cell delivery, polyurethane membranes designed to prevent herniation, and fibrin-genipin adhesive tuned to annulus fibrosus shear properties. This three-part study evaluated repair strategies for biomechanical restoration, herniation risk and failure mode in torsion, bending and compression at physiological and hyper-physiological loads using a bovine injury model. Fibrin-genipin hydrogel restored some torsional stiffness, bending ROM and disk height loss, with negligible herniation risk and failure was observed histologically at the fibrin-genipin mid-substance following rigorous loading. Scaffold-based repairs partially restored biomechanics, but had high herniation risk even when stabilized with sutured membranes and failure was observed histologically at the interface between scaffold and fibrin-genipin adhesive. Fibrin-genipin was the simplest annulus fibrosus repair solution evaluated that involved an easily deliverable adhesive that filled irregularly-shaped annular defects and partially restored disk biomechanics with low herniation risk, suggesting further evaluation for disk repair may be warranted. Statement of significance Lower back pain is the leading cause of global disability and commonly caused by defects and failure of intervertebral disk tissues resulting in herniation and compression of adjacent nerves. Annulus fibrosus repair materials and techniques have not been successful due to the challenging mechanical and chemical microenvironment and the needs to restore biomechanical behaviors and promote healing with negligible herniation risk while being delivered during surgical procedures. This work addressed this challenging biomaterial and clinical problem using novel materials including an adhesive hydrogel, a scaffold capable of cell delivery, and a membrane to prevent herniation. Composite repair strategies were evaluated and optimized in quantitative three-part study that rigorously evaluated disk repair and provided a framework for evaluating alternate repair techniques.
Resumo:
Blood loss and bleeding complications may often be observed in critically ill patients on renal replacement therapies (RRT). Here we investigate procedural (i.e. RRT-related) and non-procedural blood loss as well as transfusion requirements in regard to the chosen mode of dialysis (i.e. intermittent haemodialysis [IHD] versus continuous veno-venous haemofiltration [CVVH]). Two hundred and fifty-two patients (122 CVVH, 159 male; aged 61.5±13.9 years) with dialysis-dependent acute renal failure were analysed in a sub-analysis of the prospective randomised controlled clinical trial-CONVINT-comparing IHD and CVVH. Bleeding complications including severity of bleeding and RRT-related blood loss were assessed. We observed that 3.6% of patients died related to severe bleeding episodes (between group P=0.94). Major all-cause bleeding complications were observed in 23% IHD versus 26% of CVVH group patients (P=0.95). Under CVVH, the rate of RRT-related blood loss events (57.4% versus 30.4%, P=0.01) and mean total blood volume lost was increased (222.3±291.9 versus 112.5±222.7 ml per patient, P <0.001). Overall, transfusion rates did not differ between the study groups. In patients with sepsis, transfusion rates of all blood products were significantly higher when compared to cardiogenic shock (all P <0.01) or other conditions. In conclusion, procedural and non-procedural blood loss may often be observed in critically ill patients on RRT. In CVVH-treated patients, procedural blood loss was increased but overall transfusion rates remained unchanged. Our data show that IHD and CVVH may be regarded as equivalent approaches in critically ill patients with dialysis-dependent acute renal failure in this regard.
Resumo:
AIMS Skeletal muscle wasting affects 20% of patients with chronic heart failure and has serious implications for their activities of daily living. Assessment of muscle wasting is technically challenging. C-terminal agrin-fragment (CAF), a breakdown product of the synaptically located protein agrin, has shown early promise as biomarker of muscle wasting. We sought to investigate the diagnostic properties of CAF in muscle wasting among patients with heart failure. METHODS AND RESULTS We assessed serum CAF levels in 196 patients who participated in the Studies Investigating Co-morbidities Aggravating Heart Failure (SICA-HF). Muscle wasting was identified using dual-energy X-ray absorptiometry (DEXA) in 38 patients (19.4%). Patients with muscle wasting demonstrated higher CAF values than those without (125.1 ± 59.5 pmol/L vs. 103.8 ± 42.9 pmol/L, P = 0.01). Using receiver operating characteristics (ROC), we calculated the optimal CAF value to identify patients with muscle wasting as >87.5 pmol/L, which had a sensitivity of 78.9% and a specificity of 43.7%. The area under the ROC curve was 0.63 (95% confidence interval 0.56-0.70). Using simple regression, we found that serum CAF was associated with handgrip (R = - 0.17, P = 0.03) and quadriceps strength (R = - 0.31, P < 0.0001), peak oxygen consumption (R = - 0.5, P < 0.0001), 6-min walk distance (R = - 0.32, P < 0.0001), and gait speed (R = - 0.2, P = 0.001), as well as with parameters of kidney and liver function, iron metabolism and storage. CONCLUSION CAF shows good sensitivity for the detection of skeletal muscle wasting in patients with heart failure. Its assessment may be useful to identify patients who should undergo additional testing, such as detailed body composition analysis. As no other biomarker is currently available, further investigation is warranted.
How should I treat a patient with severe mitral regurgitation and acute decompensated heart failure?
Resumo:
Gebiet: Chirurgie Abstract: Objectives This study reports a series of pitfalls, premature failures and explantations of the third generation Freedom SOLO bovine pericardial stentless valve. – – Methods 149 patients underwent aortic valve replacement (AVR) using the FS. Follow-up was 100% complete with an average observation time of 5.5±2.3 years (max. 8.7 years) and a total of 825 patient years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. – – Results Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92%, 88%, 80% and 70% and 62%, respectively. 14 prostheses required explantation due to valve-independent dysfunction (n=5, i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n=4, severe stenosis, n=5). Thus freedom from explantation at 5, 6, 7, 8 and 9 years was 95%, 94%, 91% and 81% and 72%, respectively. An acute vertical tear along the non-coronary/right-coronary commissure to the base occurred at a mean of 6.0 years [range 4.3?7.3 years] and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years [range 7.0?8.3 years] due to severe functional stenosis and gross calcification that included the entire aortic root. – – Conclusions The Freedom SOLO stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6 ? 7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.
Resumo:
PURPOSE The objective of this study was to evaluate stiffness, strength, and failure modes of monolithic crowns produced using computer-aided design/computer-assisted manufacture, which are connected to diverse titanium and zirconia abutments on an implant system with tapered, internal connections. MATERIALS AND METHODS Twenty monolithic lithium disilicate (LS2) crowns were constructed and loaded on bone level-type implants in a universal testing machine under quasistatic conditions according to DIN ISO 14801. Comparative analysis included a 2 × 2 format: prefabricated titanium abutments using proprietary bonding bases (group A) vs nonproprietary bonding bases (group B), and customized zirconia abutments using proprietary Straumann CARES (group C) vs nonproprietary Astra Atlantis (group D) material. Stiffness and strength were assessed and calculated statistically with the Wilcoxon rank sum test. Cross-sections of each tested group were inspected microscopically. RESULTS Loaded LS2 crowns, implants, and abutment screws in all tested specimens (groups A, B, C, and D) did not show any visible fractures. For an analysis of titanium abutments (groups A and B), stiffness and strength showed equally high stability. In contrast, proprietary and nonproprietary customized zirconia abutments exhibited statistically significant differences with a mean strength of 366 N (Astra) and 541 N (CARES) (P < .05); as well as a mean stiffness of 884 N/mm (Astra) and 1,751 N/mm (CARES) (P < .05), respectively. Microscopic cross-sections revealed cracks in all zirconia abutments (groups C and D) below the implant shoulder. CONCLUSION Depending on the abutment design, prefabricated titanium abutment and proprietary customized zirconia implant-abutment connections in conjunction with monolithic LS2 crowns had the best results in this laboratory investigation.
Resumo:
BACKGROUND Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. PURPOSE The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. MATERIALS AND METHODS Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. RESULTS Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. CONCLUSIONS Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation.
Resumo:
Acute-on-chronic liver failure (ACLF) is characterized by acute decompensation (AD) of cirrhosis, organ failure(s), and high 28-day mortality. We investigated whether assessments of patients at specific time points predicted their need for liver transplantation (LT) or the potential futility of their care. We assessed clinical courses of 388 patients who had ACLF at enrollment, from February through September 2011, or during early (28-day) follow-up of the prospective multicenter European Chronic Liver Failure (CLIF) ACLF in Cirrhosis study. We assessed ACLF grades at different time points to define disease resolution, improvement, worsening, or steady or fluctuating course. ACLF resolved or improved in 49.2%, had a steady or fluctuating course in 30.4%, and worsened in 20.4%. The 28-day transplant-free mortality was low-to-moderate (6%-18%) in patients with nonsevere early course (final no ACLF or ACLF-1) and high-to-very high (42%-92%) in those with severe early course (final ACLF-2 or -3) independently of initial grades. Independent predictors of course severity were CLIF Consortium ACLF score (CLIF-C ACLFs) and presence of liver failure (total bilirubin ≥12 mg/dL) at ACLF diagnosis. Eighty-one percent had their final ACLF grade at 1 week, resulting in accurate prediction of short- (28-day) and mid-term (90-day) mortality by ACLF grade at 3-7 days. Among patients that underwent early LT, 75% survived for at least 1 year. Among patients with ≥4 organ failures, or CLIF-C ACLFs >64 at days 3-7 days, and did not undergo LT, mortality was 100% by 28 days. CONCLUSIONS Assessment of ACLF patients at 3-7 days of the syndrome provides a tool to define the emergency of LT and a rational basis for intensive care discontinuation owing to futility.
Resumo:
BACKGROUND & AIMS Cirrhotic patients with acute decompensation frequently develop acute-on-chronic liver failure (ACLF), which is associated with high mortality rates. Recently, a specific score for these patients has been developed using the CANONIC study database. The aims of this study were to develop and validate the CLIF-C AD score, a specific prognostic score for hospitalised cirrhotic patients with acute decompensation (AD), but without ACLF, and to compare this with the Child-Pugh, MELD, and MELD-Na scores. METHODS The derivation set included 1016 CANONIC study patients without ACLF. Proportional hazards models considering liver transplantation as a competing risk were used to identify score parameters. Estimated coefficients were used as relative weights to compute the CLIF-C ADs. External validation was performed in 225 cirrhotic AD patients. CLIF-C ADs was also tested for sequential use. RESULTS Age, serum sodium, white-cell count, creatinine and INR were selected as the best predictors of mortality. The C-index for prediction of mortality was better for CLIF-C ADs compared with Child-Pugh, MELD, and MELD-Nas at predicting 3- and 12-month mortality in the derivation, internal validation and the external dataset. CLIF-C ADs improved in its ability to predict 3-month mortality using data from days 2, 3-7, and 8-15 (C-index: 0.72, 0.75, and 0.77 respectively). CONCLUSIONS The new CLIF-C ADs is more accurate than other liver scores in predicting prognosis in hospitalised cirrhotic patients without ACLF. CLIF-C ADs therefore may be used to identify a high-risk cohort for intensive management and a low-risk group that may be discharged early.