97 resultados para Location precision
Resumo:
OBJECTIVES Sensorineural hearing loss from sound overexposure has a considerable prevalence. Identification of sound hazards is crucial, as prevention, due to a lack of definitive therapies, is the sole alternative to hearing aids. One subjectively loud, yet little studied, potential sound hazard is movie theaters. This study uses smart phones to evaluate their applicability as a widely available, validated sound pressure level (SPL) meter. Therefore, this study measures sound levels in movie theaters to determine whether sound levels exceed safe occupational noise exposure limits and whether sound levels in movie theaters differ as a function of movie, movie theater, presentation time, and seat location within the theater. DESIGN Six smart phones with an SPL meter software application were calibrated with a precision SPL meter and validated as an SPL meter. Additionally, three different smart phone generations were measured in comparison to an integrating SPL meter. Two different movies, an action movie and a children's movie, were measured six times each in 10 different venues (n = 117). To maximize representativeness, movies were selected focusing on large release productions with probable high attendance. Movie theaters were selected in the San Francisco, CA, area based on whether they screened both chosen movies and to represent the largest variety of theater proprietors. Measurements were analyzed in regard to differences between theaters, location within the theater, movie, as well as presentation time and day as indirect indicator of film attendance. RESULTS The smart phone measurements demonstrated high accuracy and reliability. Overall, sound levels in movie theaters do not exceed safe exposure limits by occupational standards. Sound levels vary significantly across theaters and demonstrated statistically significant higher sound levels and exposures in the action movie compared to the children's movie. Sound levels decrease with distance from the screen. However, no influence on time of day or day of the week as indirect indicator of film attendance could be found. CONCLUSIONS Calibrated smart phones with an appropriate software application as used in this study can be utilized as a validated SPL meter. Because of the wide availability, smart phones in combination with the software application can provide high quantity recreational sound exposure measurements, which can facilitate the identification of potential noise hazards. Sound levels in movie theaters decrease with distance to the screen, but do not exceed safe occupational noise exposure limits. Additionally, there are significant differences in sound levels across movie theaters and movies, but not in presentation time.
Resumo:
The CHaracterising ExOPlanet Satellite (CHEOPS) is a joint ESA-Switzerland space mission (expected to launch in 2017) dedicated to search for exoplanet transits by means of ultra-high precision photometry. CHEOPS will provide accurate radii for planets down to Earth size. Targets will mainly come from radial velocity surveys. The CHEOPS instrument is an optical space telescope of 30 cm clear aperture with a single focal plane CCD detector. The tube assembly is passively cooled and thermally controlled to support high precision, low noise photometry. The telescope feeds a re-imaging optic, which supports the straylight suppression concept to achieve the required Signal to Noise. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Resumo:
Human capital and members of the creative class are bearers of economic growth, yet little is known about exactly what the relevant factors are for the concentration of the highly skilled in a specific place. Tolerance for example is supposed to make the difference between creative and human capital. But does tolerance really make a difference for anybody? And what about other factors: Are they specifically relevant for creative individuals or simply valid for the whole population? This study contributes to the discussion on the highly skilled by investigating whether tolerance, taxes, or other regional amenities contribute to their concentration and dynamics. The results show that tolerance in particular toward immigrants, but also toward same-sex partnerships, is a rather dynamic concept, differs largely between and within functional urban regions, and makes a difference regarding the highly skilled.
Resumo:
Myosin B (MyoB) is one of the two short class XIV myosins encoded in the Plasmodium genome. Class XIV myosins are characterized by a catalytic "head," a modified "neck," and the absence of a "tail" region. Myosin A (MyoA), the other class XIV myosin in Plasmodium, has been established as a component of the glideosome complex important in motility and cell invasion, but MyoB is not well characterized. We analyzed the properties of MyoB using three parasite species as follows: Plasmodium falciparum, Plasmodium berghei, and Plasmodium knowlesi. MyoB is expressed in all invasive stages (merozoites, ookinetes, and sporozoites) of the life cycle, and the protein is found in a discrete apical location in these polarized cells. In P. falciparum, MyoB is synthesized very late in schizogony/merogony, and its location in merozoites is distinct from, and anterior to, that of a range of known proteins present in the rhoptries, rhoptry neck or micronemes. Unlike MyoA, MyoB is not associated with glideosome complex proteins, including the MyoA light chain, myosin A tail domain-interacting protein (MTIP). A unique MyoB light chain (MLC-B) was identified that contains a calmodulin-like domain at the C terminus and an extended N-terminal region. MLC-B localizes to the same extreme apical pole in the cell as MyoB, and the two proteins form a complex. We propose that MLC-B is a MyoB-specific light chain, and for the short class XIV myosins that lack a tail region, the atypical myosin light chains may fulfill that role.
Resumo:
Vitrectomy is a standard ophthalmic procedure to remove the vitreous body from the eye. The biomechanics of the vitreous affects its duration (by changing the removal rate) and the mechanical forces transmitted via the vitreous on the surrounding tissues during the procedure. Biomechanical characterization of the vitreous is essential for optimizing the design and control of instruments that operate within the vitreous for improved precision, safety, and efficacy. The measurements are carried out using a magnetic microprobe inserted into the vitreous, a method known as magnetic microrheology. The location of the probe is tracked by a microscope/camera while magnetic forces are exerted wirelessly by applied magnetic fields. In this work, in vitro artificial vitreous, ex vivo human vitreous and ex vivo porcine vitreous were characterized. In addition, in vivo rabbit measurements were performed using a suturelessly injected probe. Measurements indicate that viscoelasticity parameters of the ex vivo human vitreous are an order of magnitude different from those of the ex vivo porcine vitreous. The in vivo intra-operative measurements show typical viscoelastic behavior of the vitreous with a lower compliance than the ex vivo measurements. The results of the magnetic microrheology measurements were validated with those obtained by a standard atomic force microscopy (AFM) method and in vitro artificial vitreous. This method allows minimally-invasive characterization of localized mechanical properties of the vitreous in vitro, ex vivo, and in vivo. A better understanding of the characteristics of the vitreous can lead to improvements in treatments concerning vitreal manipulation such as vitrectomy.
Resumo:
Herbivore-induced plant volatiles are important host finding cues for larval parasitoids, and similarly, insect oviposition might elicit the release of plant volatiles functioning as host finding cues for egg parasitoids. We hypothesized that egg parasitoids also might utilize HIPVs of emerging larvae to locate plants with host eggs. We, therefore, assessed the olfactory response of two egg parasitoids, a generalist, Trichogramma pretiosum (Tricogrammatidae), and a specialist, Telenomus remus (Scelionidae) to HIPVs. We used a Y-tube olfactometer to tests the wasps’ responses to volatiles released by young maize plants that were treated with regurgitant from caterpillars of the moth Spodoptera frugiperda (Noctuidae) or were directly attacked by the caterpillars. The results show that the generalist egg parasitoid Tr. pretiosum is innately attracted by volatiles from freshly-damaged plants 0–1 and 2–3 h after regurgitant treatment. During this interval, the volatile blend consisted of green leaf volatiles (GLVs) and a blend of aromatic compounds, mono- and homoterpenes, respectively. Behavioral assays with synthetic GLVs confirmed their attractiveness to Tr. pretiosum. The generalist learned the more complex volatile blends released 6–7 h after induction, which consisted mainly of sesquiterpenes. The specialist T. remus on the other hand was attracted only to volatiles emitted from fresh and old damage after associating these volatiles with oviposition. Taken together, these results strengthen the emerging pattern that egg and larval parasitoids behave in a similar way in that generalists can respond innately to HIPVs, while specialists seems to rely more on associative learning.
Resumo:
We present new algorithms for M-estimators of multivariate scatter and location and for symmetrized M-estimators of multivariate scatter. The new algorithms are considerably faster than currently used fixed-point and related algorithms. The main idea is to utilize a second order Taylor expansion of the target functional and to devise a partial Newton-Raphson procedure. In connection with symmetrized M-estimators we work with incomplete U-statistics to accelerate our procedures initially.
Resumo:
QUESTION UNDER STUDY/PRINCIPLES This study aimed to evaluate trends in the incidence of oesophageal and gastric cancer by anatomical location and histology using nationally representative Swiss data. METHODS We included all oesophageal and gastric cancers recorded in 10 Swiss population-based cancer registries 1982-2011. We calculated age-standardised incidence rates (ASIRs) per 100 000 person-years (PY) (European standard) for both cancer sites stratified by sex, language region (German, French-Italian), morphology and anatomical location. To assess time trends, we estimated annual percentage changes (APCs) with 95% confidence intervals (95% CIs). RESULTS ASIR of oesophageal adenocarcinoma increased in both sexes and language regions (p <0.001). The steepest increase occurred in males of the German-speaking region (APC 6.8%, 95% CI 5.8-7.8) with ASIRs of 0.8 per 100,000 PY in 1982-1987 and 3.9 per 100.000 PY in 2007-2011. Incidence of oesophageal squamous cell carcinoma decreased significantly in males of both language regions by around -1.5% per year. In contrast, a slight but significant increase (APC 1.4%, 95% CI 0.3-2.4]) of oesophageal squamous cell carcinoma was observed in females of the German-speaking region. We observed stable rates for cancer of the gastric cardia. The incidence of noncardia gastric cancer decreased substantially in both sexes and language regions (p <0.001). CONCLUSION In Switzerland, the incidence of oesophageal adenocarcinoma has risen whereas incidence of noncardia gastric cancer has decreased substantially as observed in other developed countries.
Resumo:
BACKGROUND The aim of this study was to analyze the influence of the location of middle cerebral artery (MCA) occlusion on recanalization, complications and outcome after endovascular therapy. METHODS Four-hundred sixty-four patients with acute MCA occlusions were treated with endovascular therapy. RESULTS Two-hundred ninety-three patients had M1 occlusions, 116 had M2, and 55 had M3/4 occlusions. Partial or complete recanalization was more frequently achieved in M1 (76.8%) than in M2 (59.1%) or M3/4 (47.3%, p < 0.001) occlusions, but favorable outcome (modified Rankin Scale 0-2) was less frequent in M1 (50.9%) than M2 (63.7%) or M3/4 (72.7%, p = 0.018) occlusions. Symptomatic intracerebral hemorrhage (ICH) did not differ between occlusion sites, but asymptomatic ICH was more common in M1 (22.6%) than in M2 occlusions (8.6%, p = 0.003). Recanalization was associated with favorable outcome in M1 (p < 0.001) and proximal M2 (p = 0.003) but not in distal M2 or M3/4 occlusions. CONCLUSIONS Recanalization with endovascular therapy was more frequently achieved in patients with proximal than distal MCA occlusions, but recanalization was associated with favorable outcome only in M1 and proximal M2 occlusions. Outcome was better with distal than proximal occlusions. This study shows that recanalization can be used as a surrogate marker for clinical outcome only in patients with proximal occlusions.
Resumo:
We introduce a new fiber-optical approach for reflection based refractive index mapping. Our approach leads to improved stability and reliability over existing free-space confocal instruments and significantly cuts alignment efforts and reduces the number of components needed. Other than properly cleaved fiber end-faces, this setup requires no additional sample preparation. The instrument is calibrated by means of a set of samples with known refractive indices. The index steps of commercially available fibers are measured accurately down to < 10⁻³. The precision limit of the instrument is currently of the order of 10⁻⁴.