146 resultados para Knee Arthroplasty


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relative advantages of cruciate retaining or cruciate resecting total knee replacement are still controversial. If the posterior cruciate ligament (PCL) is preserved, it should be properly balanced. In a previous study, it was demonstrated that increasing the flexion gap leads to an anterior translation of the tibia relative to the femur. Based on these results, we hypothesized that cutting the PCL increases the flexion gap and lessens anterior tibial translation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Leg length inequality (LLI) was identified as a problem of total hip arthroplasty soon after its introduction. Leg lengthening is the most common form of LLI. Possible consequences are limping, neuronal dysfunction and aseptic component loosening. LLI can result in an increased strain both on the contralateral hip joint and on the abductor muscles. We assessed the influence of leg lengthening and shortening on walking capacity, hip pain, limping and patient satisfaction at 2-year follow-up. Methods 478 cases with postoperative lengthening and 275 with shortening were identified, and matched with three controls each. Rigorous adjustment for potential differences in baseline patient characteristics was performed by propensity-score matching of covariates. The arbitrarily defined desired outcomes were a walking capacity >60 minutes, no hip pain, no limping, and excellent patient satisfaction. Differences in not achieving the desired outcomes between the groups were expressed as odds ratios. Results In the lengthened case group, the odds ratio for not being able to walk for an hour was 1.70 (95% CI 1.28-2.26) for cases compared to controls, and the odds ratio for having hip pain at follow-up was 1.13 (95% CI 0.78-1.64). The odds ratio for limping was 2.08 (95% CI 1.55-2.80). The odds ratio for not achieving excellent patient satisfaction was 1.67 (95% CI 1.23-2.28). In the shortening case group, the odds ratio for not being able to walk for an hour was 1.23 (95% CI 0.84-1.81), and the odds ratio for having hip pain at follow-up was 1.60 (95% CI 1.05-2.44). The odds ratio for limping for cases was 2.61 (95% CI 1.78-3.21). The odds ratio for not achieving excellent patient satisfaction was 2.15 (95% CI 1.44-3.21). Conclusions Walking capacity, limping and patient satisfaction were all significantly associated with leg lengthening, whereas pain alleviation was not. In contrast, hip pain, limping and patient satisfaction were all significantly associated with leg shortening, whereas walking capacity was not.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We hypothesized that certain patient characteristics have different effects on the risk of early stem loosening in total hip arthroplasty (THA). We therefore conducted a case-control study using register-database records with the aim of identifying patient-specific risk factors associated with radiographic signs of aseptic loosening of the femoral component in THA. METHOD: Data were derived from a multinational European registry and were collected over a period of 25 years. 725 cases with radiographic signs of stem loosening were identified and matched to 4,310 controls without any signs of loosening. Matching criteria were type of implant, size of head, date of operation, center of primary intervention, and follow-up time. The risk factors analyzed were age at operation, sex, diagnosis and previous ipsilateral operations, height, weight, body mass index and mobility based on the Charnley classification. RESULTS: Women showed significantly lower risk of radiographic loosening than men (odds ratio (OR) 0.64). Age was also a strong factor: risk decreased by 1.8% for each additional year of age at the time of surgery. Height and weight were not associated with risk of loosening. A higher body mass index, however, increased the risk of stem loosening to a significant extent (OR 1.03) per additional unit of BMI. Charnley Class B, indicating restricted mobility, was associated with lower risk of loosening (OR 0.78). INTERPRETATION: An increased activity level, as seen in younger patients and those with unrestricted mobility, is an important factor in the etiology of stem loosening. If combined with high BMI, the risk of stem loosening within 10 years is even higher. A younger person should not be denied the benefits of a total hip arthroplasty but must accept that the risk of future failure is increased.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances in tissue-engineered cartilage open the door to new clinical treatments of joint lesions. Common to all therapies with in-vitro-engineered autografts is the need for optimal fit of the construct to allow screwless implantation and optimal integration into the live joint. Computer-assisted surgery (CAS) techniques are prime candidates to ensure the required accuracy, while at the same time simplifying the procedure. A pilot study has been conducted aiming at assembling a new set of methods to support ankle joint arthroplasty using bioengineered autografts. Computer assistance allows planning of the implant shape on a computed tomography (CT) image, manufacturing the construct according to the plan, and interoperatively navigating the surgical tools for implantation. A rotational symmetric model of the joint surface was used to avoid segmentation of the CT image; new software was developed to determine the joint axis and make the implant shape parameterizable. A complete cycle of treatment from planning to operation was conducted on a human cadaveric foot, thus proving the feasibility of computer-assisted arthroplasty using bioengineered autografts

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although loosening of cemented glenoid components is one of the major complications of total shoulder arthroplasty, there is little information about factors affecting initial fixation of these components in the scapular neck. This study was performed to assess the characteristics of structural fixation of pegged glenoid components, if inserted with two different recommended cementing techniques. Six fresh-frozen shoulder specimens and two types of glenoid components were used. The glenoids were prepared according to the instructions and with the instrumentation of the manufacturer. In 3 specimens, the bone cement was inserted into the peg receiving holes (n = 12) and applied to the back surface of the glenoid component with a syringe. In the other 3 specimens, the cement was inserted into the holes (n = 15) by use of pure finger pressure: no cement was applied on the backside of the component. Micro-computed tomography scans with a resolution of 36 microm showed an intact cement mantle around all 12 pegs (100%) when a syringe was used. An incomplete cement plug was found in 7 of 15 pegs (47%) when the finger-pressure technique was used. Cement penetration into the cancellous bone was deeper in osteopenic bone. Application of bone cement on the backside of the glenoid prosthesis improved seating by filling out small spaces between bone and polyethylene resulting from irregularities after reaming or local cement extrusion from a drill hole. The fixation of a pegged glenoid component is better if the holes are filled with cement under pressure by use of a syringe and if cement is applied to the back of the glenoid component than if cement is inserted with pure finger pressure and no cement is applied to the back surface of the component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In a prospective, nonrandomized study the outcome in terms of rehabilitation and complications of total hip arthroplasty (THA) through a superior capsulotomy exposure (study group) was compared to THA performed through a direct lateral exposure (control group). PATIENTS AND METHODS: The study group (106 THA) and the control group (107 THA) were controlled for complexity and had no significant differences in age, sex, diagnosis, or body mass index. RESULTS: The study group had improved recovery at 6 weeks after surgery which was statistically significant (p<0.001). In addition, the study group had a lower incidence of perioperative complications. CONCLUSION: The current study demonstrates the potential that less-invasive surgical techniques with the philosophy of maximally preserving the abductors, posterior capsule, and short rotators may result in a safer operation with an accelerated recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recent studies have suggested that tenotomy and repair of the subscapularis tendon carried out for anterior approaches to the shoulder can be followed by failure of the tendon repair and by changes resulting in permanent loss of subscapularis function. We hypothesized that release of the subscapularis with use of a superficial osteotomy of the lesser tuberosity followed by repair of the two opposing bone surfaces would lead to consistent bone-to-bone healing, which would be possible to monitor radiographically, and would lead to satisfactory clinical and structural outcomes. METHODS: Thirty-nine shoulders in thirty-six consecutive patients who, at an average age of fifty-seven years, had undergone total shoulder replacement through an anterior approach involving an osteotomy of the lesser tuberosity were evaluated at an average of thirty-nine months. Assessment included a standardized interview and physical examination, scoring according to the system described by Constant and Murley, and imaging with conventional radiography and computed tomography to assess healing of the osteotomy site and changes in the subscapularis. RESULTS: The osteotomized tuberosity fragment healed in an anatomical position in all shoulders, and no cuff tendon ruptures were observed. At the time of follow-up, thirty-three (89%) of thirty-seven shoulders evaluated with a belly-press test had a negative result and twenty-seven (75%) of thirty-six shoulders evaluated with a lift-off test had an unequivocally normal result. Fatty infiltration of the subscapularis muscle increased after the operation (p < 0.0001) and was at least stage two in eleven (32%) of thirty-four shoulders. The fatty infiltration had progressed by one stage in eight (24%) of the thirty-four shoulders, by two stages in five shoulders (15%), and by three stages in two shoulders (6%). CONCLUSIONS: Osteotomy of the lesser tuberosity provides an easy anterior approach for total shoulder replacement and is followed by consistent bone-to-bone healing, which can be monitored, and good subscapularis function. In the presence of documented anatomical healing of the osteotomy site, postoperative fatty infiltration of the subscapularis muscle remains unexplained and needs to be investigated further as it is associated with a poorer clinical outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the efficacy and safety of intraarticular hylan and 2 hyaluronic acids (HAs) in osteoarthritis (OA) of the knee. METHODS: This was a multicenter, patient-blind, randomized controlled trial in 660 patients with symptomatic knee OA. Patients were randomly assigned to receive 1 cycle of 3 intraarticular injections per knee of 1 of 3 preparations: a high molecular weight cross-linked hylan, a non-cross-linked medium molecular weight HA of avian origin, or a non-cross-linked low molecular weight HA of bacterial origin. The primary outcome measure was the change in the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain score at 6 months. Secondary outcome measures included local adverse events (effusions or flares) in injected knees. During months 7-12, patients were offered a second cycle of viscosupplementation. RESULTS: Pain relief was similar in all 3 groups. The difference in changes between baseline and 6 months between hylan and the combined HAs was 0.1 on the WOMAC pain score (95% confidence interval [95% CI] -0.2, 0.3). No relevant differences were observed in any of the secondary efficacy outcomes, and stratified analyses provided no evidence for differences in effects across different patient groups. There was a trend toward more local adverse events in the hylan group than in the HA groups during the first cycle (difference 2.2% [95% CI -2.4, 6.7]), and this trend became more pronounced during the second cycle (difference 6.4% [95% CI 0.6, 12.2]). CONCLUSION: We found no evidence for a difference in efficacy between hylan and HAs. In view of its higher costs and potential for more local adverse events, we see no rationale for the continued use of hylan in patients with knee OA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the effectiveness and safety of intraarticular high-molecular hylan with standard preparations of hyaluronic acids in osteoarthritis of the knee. METHODS: We performed a systematic review and meta-analysis of randomized controlled trials comparing hylan with a hyaluronic acid in patients with knee osteoarthritis. Trials were identified by systematic searches of Central, Medline, EMBase, Cinahl, the Food and Drug Administration, and Science Citation Index supplemented by hand searches of conference proceedings and reference lists (last update November 2006). Literature screening and data extraction were performed in duplicate. Effect sizes were calculated from differences in means of pain-related outcomes between treatment and control groups at the end of the trial, divided by the pooled standard deviation. Trials were combined using random-effects meta-analysis. RESULTS: Thirteen trials with a pooled total of 2,085 patients contributed to the meta-analysis. The pooled effect size was -0.27 (95% confidence interval [95% CI] -0.55, 0.01), favoring hylan, but between-trial heterogeneity was high (I(2) = 88%). Trials with blinded patients, adequate concealment of allocation, and an intent-to-treat analysis had pooled effect sizes near null. The meta-analyses on safety revealed an increased risk associated with hylan for any local adverse events (relative risk [RR] 1.91; 95% CI 1.04, 3.49; I(2) = 28%) and for flares (RR 2.04; 95% CI 1.18, 3.53; I(2) = 0%). CONCLUSION: Given the likely lack of a superior effectiveness of hylan over hyaluronic acids and the increased risk of local adverse events associated with hylan, we discourage the use of intraarticular hylan in patients with knee osteoarthritis in clinical research or practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Previous meta-analyses described moderate to large benefits of chondroitin in patients with osteoarthritis. However, recent large-scale trials did not find evidence of an effect. PURPOSE: To determine the effects of chondroitin on pain in patients with osteoarthritis. DATA SOURCES: The authors searched the Cochrane Central Register of Controlled Trials (1970 to 2006), MEDLINE (1966 to 2006), EMBASE (1980 to 2006), CINAHL (1970 to 2006), and conference proceedings; checked reference lists; and contacted authors. The last update of searches was performed on 30 November 2006. STUDY SELECTION: Studies were included if they were randomized or quasi-randomized, controlled trials that compared chondroitin with placebo or with no treatment in patients with osteoarthritis of the knee or hip. There were no language restrictions. DATA EXTRACTION: The authors extracted data in duplicate. Effect sizes were calculated from the differences in means of pain-related outcomes between treatment and control groups at the end of the trial, divided by the pooled SD. Trials were combined by using random-effects meta-analysis. DATA SYNTHESIS: 20 trials (3846 patients) contributed to the meta-analysis, which revealed a high degree of heterogeneity among the trials (I2 = 92%). Small trials, trials with unclear concealment of allocation, and trials that were not analyzed according to the intention-to-treat principle showed larger effects in favor of chondroitin than did the remaining trials. When the authors restricted the analysis to the 3 trials with large sample sizes and an intention-to-treat analysis, 40% of patients were included. This resulted in an effect size of -0.03 (95% CI, -0.13 to 0.07; I2 = 0%) and corresponded to a difference of 0.6 mm on a 10-cm visual analogue scale. A meta-analysis of 12 trials showed a pooled relative risk of 0.99 (CI, 0.76 to 1.31) for any adverse event. LIMITATIONS: For 9 trials, the authors had to use approximations to calculate effect sizes. Trial quality was generally low, heterogeneity among the trials made initial interpretation of results difficult, and exploring sources of heterogeneity in meta-regression and stratified analyses may be unreliable. CONCLUSIONS: Large-scale, methodologically sound trials indicate that the symptomatic benefit of chondroitin is minimal or nonexistent. Use of chondroitin in routine clinical practice should therefore be discouraged.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computer assisted orthopaedic surgery (CAOS) technology has recently been introduced to overcome problems resulting from acetabular component malpositioning in total hip arthroplasty. Available navigation modules can conceptually be categorized as computer tomography (CT) based, fluoroscopy based, or image-free. The current study presents a comprehensive accuracy analysis on the computer assisted placement accuracy of acetabular cups. It combines analyses using mathematical approaches, in vitro testing environments, and an in vivo clinical trial. A hybrid navigation approach combining image-free with fluoroscopic technology was chosen as the best compromise to CT-based systems. It introduces pointer-based digitization for easily assessable points and bi-planar fluoroscopy for deep-seated landmarks. From the in vitro data maximum deviations were found to be 3.6 degrees for inclination and 3.8 degrees for anteversion relative to a pre-defined test position. The maximum difference between intraoperatively calculated cup inclination and anteversion with the postoperatively measured position was 4 degrees and 5 degrees, respectively. These data coincide with worst cases scenario predictions applying a statistical simulation model. The proper use of navigation technology can reduce variability of cup placement well within the surgical safe zone. Surgeons have to concentrate on a variety of error sources during the procedure, which may explain the reported strong learning curves for CAOS technologies.