Computer-assisted arthroplasty using bioengineered autografts


Autoria(s): Sidler, Rudolf; Gonzalez Ballester, Miguel Á.; Bonél, Harald Marcel; Styner, Martin; Bardyn, Thibaut; Nolte, Lutz-Peter; Südkamp, Norbert Paul; Köstler, Wolfgang
Data(s)

01/07/2006

Resumo

Recent advances in tissue-engineered cartilage open the door to new clinical treatments of joint lesions. Common to all therapies with in-vitro-engineered autografts is the need for optimal fit of the construct to allow screwless implantation and optimal integration into the live joint. Computer-assisted surgery (CAS) techniques are prime candidates to ensure the required accuracy, while at the same time simplifying the procedure. A pilot study has been conducted aiming at assembling a new set of methods to support ankle joint arthroplasty using bioengineered autografts. Computer assistance allows planning of the implant shape on a computed tomography (CT) image, manufacturing the construct according to the plan, and interoperatively navigating the surgical tools for implantation. A rotational symmetric model of the joint surface was used to avoid segmentation of the CT image; new software was developed to determine the joint axis and make the implant shape parameterizable. A complete cycle of treatment from planning to operation was conducted on a human cadaveric foot, thus proving the feasibility of computer-assisted arthroplasty using bioengineered autografts

Formato

application/pdf

Identificador

http://boris.unibe.ch/20481/1/01657789.pdf

Sidler, Rudolf; Gonzalez Ballester, Miguel Á.; Bonél, Harald Marcel; Styner, Martin; Bardyn, Thibaut; Nolte, Lutz-Peter; Südkamp, Norbert Paul; Köstler, Wolfgang (2006). Computer-assisted arthroplasty using bioengineered autografts. IEEE engineering in medicine and biology magazine, 25(4), pp. 63-69. New York, N.Y.: Institute of Electrical and Electronics Engineers IEEE 10.1109/MEMB.2006.1657789 <http://dx.doi.org/10.1109/MEMB.2006.1657789>

doi:10.7892/boris.20481

info:doi:10.1109/MEMB.2006.1657789

info:pmid:16898660

urn:issn:0739-5175

urn:isbn:16898660

Idioma(s)

eng

Publicador

Institute of Electrical and Electronics Engineers IEEE

Relação

http://boris.unibe.ch/20481/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Sidler, Rudolf; Gonzalez Ballester, Miguel Á.; Bonél, Harald Marcel; Styner, Martin; Bardyn, Thibaut; Nolte, Lutz-Peter; Südkamp, Norbert Paul; Köstler, Wolfgang (2006). Computer-assisted arthroplasty using bioengineered autografts. IEEE engineering in medicine and biology magazine, 25(4), pp. 63-69. New York, N.Y.: Institute of Electrical and Electronics Engineers IEEE 10.1109/MEMB.2006.1657789 <http://dx.doi.org/10.1109/MEMB.2006.1657789>

Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed