76 resultados para FULL BIODEGRADABLE
Resumo:
TFIIH has been implicated in several fundamental cellular processes, including DNA repair, cell cycle progression, and transcription. In transcription, the helicase activity of TFIIH functions to melt promoter DNA; however, the in vivo function of the Cdk7 kinase subunit of TFIIH, which has been hypothesized to be involved in RNA polymerase II (Pol II) phosphorylation, is not clearly understood. Using temperature-sensitive and null alleles of cdk7, we have examined the role of Cdk7 in the activation of Drosophila heat shock genes. Several in vivo approaches, including polytene chromosome immunofluorescence, nuclear run-on assays, and, in particular, a protein-DNA cross-linking assay customized for adults, revealed that Cdk7 kinase activity is required for full activation of heat shock genes, promoter-proximal Pol II pausing, and Pol II-dependent chromatin decondensation. The requirement for Cdk7 occurs very early in the transcription cycle. Furthermore, we provide evidence that TFIIH associates with the elongation complex much longer than previously suspected.
Resumo:
BACKGROUND Ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES) proved noninferior to durable polymer everolimus-eluting stents (DP-EES) for a composite clinical end point in a population with minimal exclusion criteria. We performed a prespecified subgroup analysis of the Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation (BIOSCIENCE) trial to compare the performance of BP-SES and DP-EES in patients with diabetes mellitus. METHODS AND RESULTS BIOSCIENCE trial was an investigator-initiated, single-blind, multicentre, randomized, noninferiority trial comparing BP-SES versus DP-EES. The primary end point, target lesion failure, was a composite of cardiac death, target-vessel myocardial infarction, and clinically indicated target lesion revascularization within 12 months. Among a total of 2119 patients enrolled between February 2012 and May 2013, 486 (22.9%) had diabetes mellitus. Overall diabetic patients experienced a significantly higher risk of target lesion failure compared with patients without diabetes mellitus (10.1% versus 5.7%; hazard ratio [HR], 1.80; 95% confidence interval [CI], 1.27-2.56; P=0.001). At 1 year, there were no differences between BP-SES versus DP-EES in terms of the primary end point in both diabetic (10.9% versus 9.3%; HR, 1.19; 95% CI, 0.67-2.10; P=0.56) and nondiabetic patients (5.3% versus 6.0%; HR, 0.88; 95% CI, 0.58-1.33; P=0.55). Similarly, no significant differences in the risk of definite or probable stent thrombosis were recorded according to treatment arm in both study groups (4.0% versus 3.1%; HR, 1.30; 95% CI, 0.49-3.41; P=0.60 for diabetic patients and 2.4% versus 3.4%; HR, 0.70; 95% CI, 0.39-1.25; P=0.23, in nondiabetics). CONCLUSIONS In the prespecified subgroup analysis of the BIOSCIENCE trial, clinical outcomes among diabetic patients treated with BP-SES or DP-EES were comparable at 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01443104.
Resumo:
Aberrations of the acoustic wave front, caused by spatial variations of the speed-of-sound, are a main limiting factor to the diagnostic power of medical ultrasound imaging. If not accounted for, aberrations result in low resolution and increased side lobe level, over all reducing contrast in deep tissue imaging. Various techniques have been proposed for quantifying aberrations by analysing the arrival time of coherent echoes from so-called guide stars or beacons. In situations where a guide star is missing, aperture-based techniques may give ambiguous results. Moreover, they are conceptually focused on aberrators that can be approximated as a phase screen in front of the probe. We propose a novel technique, where the effect of aberration is detected in the reconstructed image as opposed to the aperture data. The varying local echo phase when changing the transmit beam steering angle directly reflects the varying arrival time of the transmit wave front. This allows sensing the angle-dependent aberration delay in a spatially resolved way, and thus aberration correction for a spatially distributed volume aberrator. In phantoms containing a cylindrical aberrator, we achieved location-independent diffraction-limited resolution as well as accurate display of echo location based on reconstructing the speed-of-sound spatially resolved. First successful volunteer results confirm the clinical potential of the proposed technique.
Resumo:
This study presents static measurements of the Ca isotopic composition of standard reference materials SRM 915 a/b on a Triton Plus™ thermal ionization mass spectrometer with a specially developed Faraday cup array allowing simultaneous measurement of 40Ca and 48Ca. The total amount of Ca in all analyses was kept < 1 µg. With this setup the measurement uncertainties were 0.06 ‰ for 40Ca/44Ca and 0.12 ‰ for 48Ca/40Ca. Measuring all isotopes simultaneously better allows to test the internal consistency of different Ca isotope abundances reported in the literature. The exponential law was observed to correct incompletely instrumental mass fractionation. An improved fractionation correction based on the exponential law is proposed. It changes the 40Ca/44Ca ratio of SRM 915a (corrected relative to 42Ca/44Ca = 0.31221; 48Ca/44Ca = 0.08871) from 47.1635 ± 0.0028 to 47.1649 ± 0.0047. The measurements of SRM 915b were performed with different analytical conditions (runs were prolonged till complete filament load depletion). Even if the 40Ca/44Ca ratio of SRM 915b, when corrected with the simple exponential law, appears different (47.1532 ± 0.0038) from that of SRM 915a, it becomes coincident (47.1613 ± 0.0028) when corrected with a second-order refinement. This supports the use of the improved exponential law to obtain internally consistent Ca isotope ratio for natural samples.
Resumo:
AIMS Our aim was to compare the safety and efficacy of a novel, ultrathin strut, biodegradable polymer sirolimus-eluting stent (BP-SES) with a thin strut, durable polymer everolimus-eluting stent (DP-EES) in a pre-specified subgroup of patients with acute ST-segment elevation myocardial infarction (STEMI) enrolled in the BIOSCIENCE trial. METHODS AND RESULTS The BIOSCIENCE trial is an investigator-initiated, single-blind, multicentre, randomised non-inferiority trial (NCT01443104). Randomisation was stratified according to the presence or absence of STEMI. The primary endpoint, target lesion failure (TLF), is a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation within 12 months. Between February 2012 and May 2013, 407 STEMI patients were randomly assigned to treatment with BP-SES or DP-EES. At one year, TLF occurred in seven (3.4%) patients treated with BP-SES and 17 (8.8%) patients treated with DP-EES (RR 0.38, 95% CI: 0.16-0.91, p=0.024). Rates of cardiac death were 1.5% in the BP-SES group and 4.7% in the DP-EES group (RR 0.31, 95% CI: 0.08-1.14, p=0.062); rates of target vessel myocardial infarction were 0.5% and 2.6% (RR 0.18, 95% CI: 0.02-1.57, p=0.082), respectively, and rates of clinically indicated target lesion revascularisation were 1.5% in the BP-SES group versus 2.1% in the DP-EES group (RR 0.69, 95% CI: 0.16-3.10, p=0.631). There was no difference in the risk of definite stent thrombosis. CONCLUSIONS In this pre-specified subgroup analysis, BP-SES was associated with a lower rate of target lesion failure at one year compared to DP-EES in STEMI patients. These findings require confirmation in a dedicated STEMI trial.
Resumo:
OBJECTIVE The purpose of this study was to examine the recurrence rate of wound rupture in primary pilonidal sinus disease (PSD) after median closure. SUBJECTS AND METHODS A total of 583 patients from the German military cohort were interviewed. We compared the choice of surgical therapy, wound dehiscence (if present) and long-term recurrence-free survival for patients with primary open treatment, marsupialization and primary median treatment (closed vs. secondary open, respectively). Actuarial recurrence rate was determined using the Kaplan-Meier calculation with a follow-up of up to 20 years after primary PSD surgery. RESULTS Patients with excision followed by primary open wound treatment showed a significantly lower 5- than 10-year recurrence rate (8.3 vs. 11.2%) compared to the patients with primary midline closure (17.4 vs. 20.5%, p = 0.03). The 20-year recurrence rate was 28% in primary open wound treatment versus 44% in primary midline closure without wound rupture. In contrast to these findings, long-term recurrence rates following secondary open wound treatment (12.2% at 5 years vs. 17.1% at 10 years) tended to be higher (although not significantly, p = 0.57) compared to primary open treatment (8.3% at 5 years vs. 11.2% at 10 years). There was no statistical difference in long-term recurrence rates between secondary open and primary midline closure (p = 0.7). Hence, despite only a short wound closure time experienced before wound rupture, the patient does not fully benefit from an open wound treatment in terms of recurrence rate. CONCLUSION The postoperative pilonidal sinus wound rupture of primary midline closures did not significantly increase the 5- and 10-year long-term recurrence rates compared to uneventfully healing primary midline closures.
Resumo:
Purpose: The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). Materials and Methods: 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. Results: The overall sensitivity of LS was 49.2 %, the specificity was 93.3 %, the positive predictive value was 91 %, and the negative predictive value was 57.5 %. The overall sensitivity for vertebral fractures was 16.7 %, and the specificity was 100 %. The sensitivity was 48.7 % and the specificity 98.2 % for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS. 40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. Conclusion: The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT. Key Points: • The overall sensitivity of LS for truncal skeleton injuries in multiple-trauma patients was < 50 %.• The diagnostic reference standard MSCT is the preferred and reliable imaging modality.• LS may be valuable for quick detection of extremity fractures. Citation Format: • Jöres APW., Heverhagen JT, Bonél H et al. Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography. Fortschr Röntgenstr 2016; 188: 163 - 171.
Resumo:
BACKGROUND No data are available on the long-term performance of ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES). We reported 2-year clinical outcomes of the BIOSCIENCE (Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation) trial, which compared BP-SES with durable-polymer everolimus-eluting stents (DP-EES) in patients undergoing percutaneous coronary intervention. METHODS AND RESULTS A total of 2119 patients with minimal exclusion criteria were assigned to treatment with BP-SES (n=1063) or DP-EES (n=1056). Follow-up at 2 years was available for 2048 patients (97%). The primary end point was target-lesion failure, a composite of cardiac death, target-vessel myocardial infarction, or clinically indicated target-lesion revascularization. At 2 years, target-lesion failure occurred in 107 patients (10.5%) in the BP-SES arm and 107 patients (10.4%) in the DP-EES arm (risk ratio [RR] 1.00, 95% CI 0.77-1.31, P=0.979). There were no significant differences between BP-SES and DP-EES with respect to cardiac death (RR 1.01, 95% CI 0.62-1.63, P=0.984), target-vessel myocardial infarction (RR 0.91, 95% CI 0.60-1.39, P=0.669), target-lesion revascularization (RR 1.17, 95% CI 0.81-1.71, P=0.403), and definite stent thrombosis (RR 1.38, 95% CI 0.56-3.44, P=0.485). There were 2 cases (0.2%) of definite very late stent thrombosis in the BP-SES arm and 4 cases (0.4%) in the DP-EES arm (P=0.423). In the prespecified subgroup of patients with ST-segment elevation myocardial infarction, BP-SES was associated with a lower risk of target-lesion failure compared with DP-EES (RR 0.48, 95% CI 0.23-0.99, P=0.043, Pinteraction=0.026). CONCLUSIONS Comparable safety and efficacy profiles of BP-SES and DP-EES were maintained throughout 2 years of follow-up. CLINICAL TRIAL REGISTRATION URL: https://www.clinicaltrials.gov. Unique identifier: NCT01443104.
Resumo:
A human interleukin 4 (hIL-4)-encoding cDNA (hIL4) probe was used to screen a bovine genomic library, and three clones containing sequences with homology to the human and mouse IL4 cDNAs were isolated. Sequence information obtained from one of these genomic clones was used to design an oligodeoxyribonucleotide primer corresponding to the transcription start point region for use in the polymerase chain reaction (PCR). The PCR-RACE protocol, designed for the rapid amplification of cDNA ends, was successfully used to generate a full-length bovine IL4 (bIL4) cDNA clone from polyadenylated RNA isolated from concanavalin A-stimulated bovine lymph node cells. The bIL4 cDNA is 570 bp in length and contains an open reading frame of 405 nucleotides (nt), coding for a 15.1-kDa precursor of 135 amino acids (aa), which should be reduced to 12.6 kDa for unglycosylated bIL4 after cleavage of a putative hydrophobic leader sequence of 24 aa. The aa sequence contains one possible Asn-linked glycosylation site. Bovine IL4 is shorter than mouse (mIL4) and hIL4, because of a 51-nt deletion in the coding region. Comparison of the overall nt and deduced aa sequences shows a greater homology of bIL4 with hIL4 than with mIL4. This homology is not evenly distributed, however, with the nt sequences 5' and 3' of the coding region showing a much greater homology between all three species than the coding sequence.