102 resultados para Definite
Resumo:
BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.
Resumo:
BACKGROUND: Little is known on the "very" long-term incidence of major adverse cardiac events (MACE), target-lesion revascularization (TLR), target-vessel revascularization and stent thrombosis after sirolimus-eluting stent (SES) implantation. We present the first study to provide a 10-year clinical follow-up in an unselected patient population who underwent SES implantation. METHODS AND RESULTS: We ran a systematic 10-year clinical follow-up in a series of 200 consecutive patients treated with unrestricted SES implantation between April 2002 and April 2003 in two Swiss hospitals. Outcomes and follow-up were obtained in all 200 patients. The cumulative 10-year MACE rate was 47% with all-cause death of 20%, cardiac death of 9%, myocardial infarction of 7%, TLR and target-vessel revascularization of 8% and 11% respectively. Academic Research Consortium-defined "definite and probable" stent thrombosis-rate was 2.5%. TLR risk was maximal between 3 to 6 years. New lesion revascularization increased throughout the study period. CONCLUSION: Incidence of TLR was maximal 3 to 6 years after SES implantation and decreased thereafter. MACE and non-TLR revascularization rates steadily increased during the complete follow-up underlining the progression of coronary artery disease.
Resumo:
INTRODUCTION Rates of both TB/HIV co-infection and multi-drug-resistant (MDR) TB are increasing in Eastern Europe (EE). Data on the clinical management of TB/HIV co-infected patients are scarce. Our aim was to study the clinical characteristics of TB/HIV patients in Europe and Latin America (LA) at TB diagnosis, identify factors associated with MDR-TB and assess the activity of initial TB treatment regimens given the results of drug-susceptibility tests (DST). MATERIAL AND METHODS We enrolled 1413 TB/HIV patients from 62 clinics in 19 countries in EE, Western Europe (WE), Southern Europe (SE) and LA from January 2011 to December 2013. Among patients who completed DST within the first month of TB therapy, we linked initial TB treatment regimens to the DST results and calculated the distribution of patients receiving 0, 1, 2, 3 and ≥4 active drugs in each region. Risk factors for MDR-TB were identified in logistic regression models. RESULTS Significant differences were observed between EE (n=844), WE (n=152), SE (n=164) and LA (n=253) for use of combination antiretroviral therapy (cART) at TB diagnosis (17%, 40%, 44% and 35%, p<0.0001), a definite TB diagnosis (culture and/or PCR positive for Mycobacterium tuberculosis; 47%, 71%, 72% and 40%, p<0.0001) and MDR-TB prevalence (34%, 3%, 3% and 11%, p <0.0001 among those with DST results). The history of injecting drug use [adjusted OR (aOR) = 2.03, (95% CI 1.00-4.09)], prior TB treatment (aOR = 3.42, 95% CI 1.88-6.22) and living in EE (aOR = 7.19, 95% CI 3.28-15.78) were associated with MDR-TB. For 569 patients with available DST, the initial TB treatment contained ≥3 active drugs in 64% of patients in EE compared with 90-94% of patients in other regions (Figure 1a). Had the patients received initial therapy with standard therapy [Rifampicin, Isoniazid, Pyrazinamide, Ethambutol (RHZE)], the corresponding proportions would have been 64% vs. 86-97%, respectively (Figure 1b). CONCLUSIONS In EE, TB/HIV patients had poorer exposure to cART, less often a definitive TB diagnosis and more often MDR-TB compared to other parts of Europe and LA. Initial TB therapy in EE was sub-optimal, with less than two-thirds of patients receiving at least three active drugs, and improved compliance with standard RHZE treatment does not seem to be the solution. Improved management of TB/HIV patients requires routine use of DST, initial TB therapy according to prevailing resistance patterns and more widespread use of cART.
Resumo:
OBJECTIVE To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up. METHODS The LEADERS trial is a multicentre all-comer study, where patients (n=1707) were randomised to percutaneous intervention with either BES containing biodegradable polymer or SES containing durable polymer. Out of 1707 patients enrolled in this trial, 573 patients had percutaneous coronary intervention for AMI (BES=280, SES=293) and were included in the current analysis. Patient-oriented composite endpoint (POCE, including all death, all myocardial infarction (MI) and all revascularisations), major adverse cardiac events (MACE, including cardiac death, MI and clinically indicated target vessel revascularisation) and stent thrombosis were assessed at 5-year follow-up. RESULTS The baseline clinical, angiographic and procedural characteristics were well matched between BES and SES groups. In all patients with AMI, coronary intervention with a BES, compared with SES, significantly reduced POCE (28.9% vs 42.3%; relative risk (RR) 0.61, 95% CI 0.47 to 0.82, p=0.001) at 5-year follow-up. There was also a reduction in MACE rate in the BES group (18.2% vs 25.9%; RR 0.67, 95% CI 0.47 to 0.95, p=0.025); however, there was no difference in cardiac death and stent thrombosis. In patients with ST-elevation MI (STEMI), coronary intervention with BES significantly reduced POCE (24.4% vs 39.3%; RR 0.55, 95% CI 0.36 to 0.85, p=0.006), MACE (12.6% vs 25.0%; RR 0.47, 95% CI 0.26 to 0.83, p=0.008) and cardiac death (3.0% vs 11.4%; RR 0.25, 95% CI 0.08 to 0.75, p=0.007), along with a trend towards reduction in definite stent thrombosis (3.7% vs 8.6%; RR 0.41, 95% CI 0.15 to 1.18, p=0.088), compared with SES. CONCLUSIONS BES, compared with SES, significantly improved safety and efficacy outcomes in patients with AMI, especially those with STEMI, at 5-year follow-up. TRIAL REGISTRATION NUMBER NCT 00389220.
Resumo:
A large body of empirical research shows that psychosocial risk factors (PSRFs) such as low socio-economic status, social isolation, stress, type-D personality, depression and anxiety increase the risk of incident coronary heart disease (CHD) and also contribute to poorer health-related quality of life (HRQoL) and prognosis in patients with established CHD. PSRFs may also act as barriers to lifestyle changes and treatment adherence and may moderate the effects of cardiac rehabilitation (CR). Furthermore, there appears to be a bidirectional interaction between PSRFs and the cardiovascular system. Stress, anxiety and depression affect the cardiovascular system through immune, neuroendocrine and behavioural pathways. In turn, CHD and its associated treatments may lead to distress in patients, including anxiety and depression. In clinical practice, PSRFs can be assessed with single-item screening questions, standardised questionnaires, or structured clinical interviews. Psychotherapy and medication can be considered to alleviate any PSRF-related symptoms and to enhance HRQoL, but the evidence for a definite beneficial effect on cardiac endpoints is inconclusive. A multimodal behavioural intervention, integrating counselling for PSRFs and coping with illness should be included within comprehensive CR. Patients with clinically significant symptoms of distress should be referred for psychological counselling or psychologically focused interventions and/or psychopharmacological treatment. To conclude, the success of CR may critically depend on the interdependence of the body and mind and this interaction needs to be reflected through the assessment and management of PSRFs in line with robust scientific evidence, by trained staff, integrated within the core CR team.
Resumo:
OBJECTIVE Everolimus drug-eluting stents (EES) are superior to early-generation drug-eluting stents (DES), releasing sirolimus (SES) or paclitaxel (PES) in preventing stent thrombosis (ST). Since an impaired LVEF seems to increase the risk of ST, we aimed to investigate the difference in outcome of patients with varying LVEF using EES versus early-generation DES. METHODS In a prospective cohort study, we compared the risk of ST in patients in three LVEF subgroups: normal (LVEF >50%), mildly impaired (LVEF >40% and ≤50%) and moderate-severely impaired (LVEF ≤40%). Within these various LVEF groups, we compared EES with SES and PES after adjustment for baseline differences. RESULTS We assessed a cohort of 5363 patients, with follow-up of up to 4 years and available LVEF. Overall definite ST occurred in 123 (2.3%) patients. ST rates were higher in the LVEF moderate-severely impaired group compared with the normal LVEF group (2.8% vs 2.1%; HR 1.82; CI 1.10 to 3.00). Especially early ST (EST) was more frequent in the moderate-severely impaired LVEF group (HR 2.20; CI 1.06 to 4.53). Overall rates of definite ST were lower in patients using EES compared with patients using SES or PES in all LVEF groups. Interaction terms were not statistically significant. ST rates were higher in the moderate-severely impaired LVEF group compared with the normal LVEF group when using SES or PES, but not significantly different when using EES. CONCLUSIONS EES was associated with a lower risk of definite ST compared with early-generation DES. This lower risk was independent of LVEF, even though ST rates were higher in patients with a moderate-severely impaired LVEF. TRIAL REGISTRATION NO MEC-2013-262.
Resumo:
Aims: We conducted a pooled post hoc analysis (RESOLUTE All Comers and RESOLUTE International) of patients who had the Resolute® zotarolimus-eluting stent (R-ZES) implanted in revascularised total occlusions (TO) compared with patients treated with R-ZES for non-occluded lesions. Methods and results: Patients were divided into three groups: chronic TO (CTO; n=256), non-chronic TO (n=292), and no occlusion (n=2,941). Clinical and safety outcomes assessed through two years included target lesion failure (TLF: cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularisation) and Academic Research Consortium definite or probable stent thrombosis. The rate of TLF at two years was not significantly different among patients in the CTO (9.1%), TO (9.8%), and no occlusion (10.4%) groups (log-rank p=0.800); neither were the components of TLF. Definite or probable stent thrombosis occurred more frequently in the TO group (2.8% vs. 1.2% in the CTO and 1.1% in the group with no occlusion, p=0.027). There were 10 late and six very late stent thrombosis events. Conclusions: Apart from a higher rate of stent thrombosis in patients with TO, patients with totally occluded coronary arteries who receive revascularisation with an R-ZES have clinical outcomes comparable to those who receive a similar stent in non-occluded lesions.
Resumo:
Aims: The reported rate of stent thrombosis (ST) after drug-eluting stent (DES) implantation varies among registries. To investigate differences in baseline characteristics and clinical outcome in European and Japanese all-comers registries, we performed a pooled analysis of patient-level data. Methods and results: The j-Cypher registry (JC) is a multicentre observational study conducted in Japan, including 12,824 patients undergoing SES implantation. From the Bern-Rotterdam registry (BR) enrolled at two academic hospitals in Switzerland and the Netherlands, 3,823 patients with SES were included in the current analysis. Patients in BR were younger, more frequently smokers and presented more frequently with ST-elevation myocardial infarction (MI). Conversely, JC patients more frequently had diabetes and hypertension. At five years, the definite ST rate was significantly lower in JC than BR (JC 1.6% vs. BR 3.3%, p<0.001), while the unadjusted mortality tended to be lower in BR than in JC (BR 13.2% vs. JC 14.4%, log-rank p=0.052). After adjustment, the j-Cypher registry was associated with a significantly lower risk of all-cause mortality (HR 0.56, 95% CI: 0.49-0.64) as well as definite stent thrombosis (HR 0.46, 95% CI: 0.35-0.61). Conclusions: The baseline characteristics of the two large registries were different. After statistical adjustment, JC was associated with lower mortality and ST.
Resumo:
OBJECTIVES The aim of the study was to investigate 4-year outcomes and predictors of repeat revascularization in patients treated with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Minneapolis, Minnesota) and XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Abbott Park, Illinois) in the RESOLUTE (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) All-Comers trial. BACKGROUND Data on long-term outcomes of new-generation drug-eluting stents are limited, and predictors of repeat revascularization due to restenosis and/or progression of disease are largely unknown. METHODS Patients were randomly assigned to treatment with the R-ZES (n = 1,140) or the EES (n = 1,152). We assessed pre-specified safety and efficacy outcomes at 4 years including target lesion failure and stent thrombosis. Predictors of revascularization at 4 years were identified by Cox regression analysis. RESULTS At 4 years, the rates of target lesion failure (15.2% vs. 14.6%, p = 0.68), cardiac death (5.4% vs. 4.7%, p = 0.44), and target vessel myocardial infarction (5.3% vs. 5.4%, p = 1.00), clinically-indicated target lesion revascularization (TLR) (7.0% vs. 6.5%, p = 0.62), and definite/probable stent thrombosis (2.3% vs. 1.6%, p = 0.23) were similar with the R-ZES and EES. Independent predictors of TLR were age, insulin-treated diabetes, SYNTAX (Synergy between PCI with Taxus and Cardiac Surgery) score, treatment of saphenous vein grafts, ostial lesions, and in-stent restenosis. Independent predictors of any revascularization were age, diabetes, previous percutaneous coronary intervention, absence of ST-segment elevation myocardial infarction, smaller reference vessel diameter, SYNTAX score, and treatment of left anterior descending, right coronary artery, saphenous vein grafts, ostial lesions, or in-stent restenosis. CONCLUSIONS R-ZES and EES demonstrated similar safety and efficacy throughout 4 years. TLR represented less than one-half of all repeat revascularization procedures. Patient- and lesion-related factors predicting the risk of TLR and any revascularization showed considerable overlap. (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention [RESOLUTE-AC]; NCT00617084).
Resumo:
AIM The optimal duration of dual antiplatelet therapy (DAPT) following the use of new generation drug-eluting stents is unknown. METHODS AND RESULTS The association between DAPT interruption and the rates of stent thrombosis (ST) and cardiac death/target-vessel myocardial infarction (CD/TVMI) in patients receiving a Resolute zotarolimus-eluting stent (R-ZES) was analysed in 4896 patients from the pooled RESOLUTE clinical programme. Daily acetylsalicylate (ASA) and a thienopyridine for 6-12 months were prescribed. A DAPT interruption was defined as any interruption of ASA and/or a thienopyridine of >1 day; long interruptions were >14 days. Three groups were analysed: no interruption, interruption during the first month, and >1-12 months. There were 1069 (21.83%) patients with a DAPT interruption and 3827 patients with no interruption. Among the 166 patients in the 1-month interruption group, 6 definite/probable ST events occurred (3.61%; all long DAPT interruptions), and among the 903 patients in the >1-12 months (60% occurred between 6 and 12 months) interruption group, 1 ST event occurred (0.11%; 2-day DAPT interruption). Among patients with no DAPT interruption, 32 ST events occurred (0.84%). Rates of CD/TVMI were 6.84% in the 1-month long interruption group, 1.41% in the >1-12 months long interruption group, and 4.08% in patients on continuous DAPT. CONCLUSION In a pooled population of patients receiving an R-ZES, DAPT interruptions within 1 month are associated with a high risk of adverse outcomes. Dual antiplatelet therapy interruptions between 1 and 12 months were associated with low rates of ST and adverse cardiac outcomes. Randomized clinical trials are needed to determine whether early temporary or permanent interruption of DAPT is truly safe. CLINICAL TRIALSGOV IDENTIFIERS NCT00617084; NCT00726453; NCT00752128; NCT00927940.
Resumo:
BACKGROUND: The clinical role of atrial fibrillation/atrial flutter (AF-AFl) and variables predicting these arrhythmias are not well defined in patients with arrhythmogenic right ventricular dysplasia (ARVD). We hypothesized that transthoracic echocardiography (TTE) and 12-lead electrocardiography (ECG) would be helpful in predicting AF-AFl in these patients. METHODS AND RESULTS: ECGs and TTEs of 90 patients diagnosed with definite or borderline ARVD (2010 Task Force Criteria) were analyzed. Data were compared in (1) patients with AF-AFl and (2) all other patients. A total of 18 (20%) patients experienced AF-AFl during a median follow-up of 5.8 years (interquartile range 2.0-10.4). Kaplan-Meier analysis revealed reduced times to AF-AFl among patients with echocardiographic RV fractional area change <27% (P<0.001), left atrial diameter ≥24.4 mm/m(2)(parasternal long-axis, P=0.001), and right atrial short-axis diameter ≥22.1 mm/m(2)(apical 4-chamber view, P=0.05). From all ECG variables, P mitrale conferred the highest hazard ratio (3.37, 95% confidence interval 0.92-12.36, P=0.067). Five patients with AF-AFl experienced inappropriate implantable cardioverter-defibrillator (ICD) shocks compared with 4 without AF-AFl (36% vs. 9%, P=0.03). AF-AFl was more prevalent in heart-transplant patients and those who died of cardiac causes (56% vs. 16%, P=0.014). CONCLUSIONS: AF-AFl is associated with inappropriate ICD shocks, heart transplantation, and cardiac death in patients with ARVD. Evidence of reduced RV function and atrial dilation helps to identify the ARVD patients at increased risk for AF-AFl.
Resumo:
BACKGROUND Although new-generation drug-eluting stents represent the standard of care among patients undergoing percutaneous coronary intervention, there remains debate about differences in efficacy and the risk of stent thrombosis between the Resolute zotarolimus-eluting stent (R-ZES) and the everolimus-eluting stent (EES). The aim of this study was to evaluate the safety and efficacy of the R-ZES compared with EES in patients undergoing percutaneous coronary intervention. METHODS AND RESULTS A systematic literature search of electronic resources was performed using specific search terms until September 2014. Random-effects meta-analysis was performed comparing clinical outcomes between patients treated with R-ZES and EES up to maximum available follow-up. The primary efficacy end point was target-vessel revascularization. The primary safety end point was definite or probable stent thrombosis. Secondary safety end points were cardiac death and target-vessel myocardial infarction. Five trials were identified, including a total of 9899 patients. Compared with EES, R-ZES had similar risks of target-vessel revascularization (risk ratio [RR], 1.06; 95% confidence interval [CI], 0.90-1.24; P=0.50), definite or probable stent thrombosis (RR, 1.26; 95% CI, 0.86-1.85; P=0.24), cardiac death (RR, 1.01; 95% CI, 0.79-1.30; P=0.91), and target-vessel myocardial infarction (RR, 1.10; 95% CI, 0.89-1.36; P=0.39). Moreover, R-ZES and EES had similar risks of late definite or probable very late stent thrombosis (RR, 1.06; 95% CI, 0.53-2.11; P=0.87). No evidence of significant heterogeneity was observed across trials. CONCLUSIONS R-ZES and EES provide similar safety and efficacy among patients undergoing percutaneous coronary intervention.
Resumo:
INTRODUCTION AND OBJECTIVES There is continued debate about the routine use of aspiration thrombectomy in patients with ST-segment elevation myocardial infarction. Our aim was to evaluate clinical and procedural outcomes of aspiration thrombectomy-assisted primary percutaneous coronary intervention compared with conventional primary percutaneous coronary intervention in patients with ST-segment elevation myocardial infarction. METHODS We performed a meta-analysis of 26 randomized controlled trials with a total of 11 943 patients. Clinical outcomes were extracted up to maximum follow-up and random effect models were used to assess differences in outcomes. RESULTS We observed no difference in the risk of all-cause death (pooled risk ratio = 0.88; 95% confidence interval, 0.74-1.04; P = .124), reinfarction (pooled risk ratio = 0.85; 95% confidence interval, 0.67-1.08; P = .176), target vessel revascularization (pooled risk ratio = 0.86; 95% confidence interval, 0.73-1.00; P = .052), or definite stent thrombosis (pooled risk ratio = 0.76; 95% confidence interval, 0.49-1.16; P = .202) between the 2 groups at a mean weighted follow-up time of 10.4 months. There were significant reductions in failure to reach Thrombolysis In Myocardial Infarction 3 flow (pooled risk ratio = 0.70; 95% confidence interval, 0.60-0.81; P < .001) or myocardial blush grade 3 (pooled risk ratio = 0.76; 95% confidence interval, 0.65-0.89; P = .001), incomplete ST-segment resolution (pooled risk ratio = 0.72; 95% confidence interval, 0.62-0.84; P < .001), and evidence of distal embolization (pooled risk ratio = 0.61; 95% confidence interval, 0.46-0.81; P = .001) with aspiration thrombectomy but estimates were heterogeneous between trials. CONCLUSIONS Among unselected patients with ST-segment elevation myocardial infarction, aspiration thrombectomy-assisted primary percutaneous coronary intervention does not improve clinical outcomes, despite improved epicardial and myocardial parameters of reperfusion. Full English text available from:www.revespcardiol.org/en.
Resumo:
BACKGROUND Ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES) proved noninferior to durable polymer everolimus-eluting stents (DP-EES) for a composite clinical end point in a population with minimal exclusion criteria. We performed a prespecified subgroup analysis of the Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation (BIOSCIENCE) trial to compare the performance of BP-SES and DP-EES in patients with diabetes mellitus. METHODS AND RESULTS BIOSCIENCE trial was an investigator-initiated, single-blind, multicentre, randomized, noninferiority trial comparing BP-SES versus DP-EES. The primary end point, target lesion failure, was a composite of cardiac death, target-vessel myocardial infarction, and clinically indicated target lesion revascularization within 12 months. Among a total of 2119 patients enrolled between February 2012 and May 2013, 486 (22.9%) had diabetes mellitus. Overall diabetic patients experienced a significantly higher risk of target lesion failure compared with patients without diabetes mellitus (10.1% versus 5.7%; hazard ratio [HR], 1.80; 95% confidence interval [CI], 1.27-2.56; P=0.001). At 1 year, there were no differences between BP-SES versus DP-EES in terms of the primary end point in both diabetic (10.9% versus 9.3%; HR, 1.19; 95% CI, 0.67-2.10; P=0.56) and nondiabetic patients (5.3% versus 6.0%; HR, 0.88; 95% CI, 0.58-1.33; P=0.55). Similarly, no significant differences in the risk of definite or probable stent thrombosis were recorded according to treatment arm in both study groups (4.0% versus 3.1%; HR, 1.30; 95% CI, 0.49-3.41; P=0.60 for diabetic patients and 2.4% versus 3.4%; HR, 0.70; 95% CI, 0.39-1.25; P=0.23, in nondiabetics). CONCLUSIONS In the prespecified subgroup analysis of the BIOSCIENCE trial, clinical outcomes among diabetic patients treated with BP-SES or DP-EES were comparable at 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01443104.
Resumo:
In the fermion loop formulation the contributions to the partition function naturally separate into topological equivalence classes with a definite sign. This separation forms the basis for an efficient fermion simulation algorithm using a fluctuating open fermion string. It guarantees sufficient tunnelling between the topological sectors, and hence provides a solution to the fermion sign problem affecting systems with broken supersymmetry. Moreover, the algorithm shows no critical slowing down even in the massless limit and can hence handle the massless Goldstino mode emerging in the supersymmetry broken phase. In this paper – the third in a series of three – we present the details of the simulation algorithm and demonstrate its efficiency by means of a few examples.