72 resultados para Advertising Standards
Resumo:
Introduction The global prevalence of pathologic myopia is 0.9-3.1%, and visual impairment is found in 0.1-0.5% of European and 0.2-1.4% of Asian studies. Myopic choroidal neovascularization (mCNV) affects 5.2-11.3% of pathologic myopia patients and is a leading cause of vision impairment in the working-age population. Characteristic morphological changes and visual-acuity decrease are diagnostic features. Vascular-Endothelial-Growth-Factor (VEGF) has been identified as a trigger for pathologic neovascularization in these highly myopic patients. Areas Covered We cover the epidemiology, pathology and diagnostic aspects of mCNV. The history of therapeutic interventions is described, followed by an overview of current standard-of-care (SOC)-blocking VEGF using bevacizumab (off-label), ranibizumab or aflibercept and improving vision up to 13.5-14.4 letters. Despite good efficacy, an unmet medical need remains. We summarize ongoing and future developments of new drugs to treat or potentially cure mCNV. Expert Opinion mCNV is a major global health concern. Early detection and treatment is key for a satisfying outcome. The current SOC, VEGF inhibitors, affords good therapeutic efficacy and reasonable disease stabilization with few intravitreal treatments per year. However, the long-term prognosis is still unsatisfactory, and side-effects like chorioretinal atrophy development are of concern. Therefore, efforts should be intensified to develop more effective therapies.
Resumo:
CONCLUSION Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. OBJECTIVES To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. METHOD To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. RESULTS Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.
Resumo:
Sediments can act as long-term sinks for environmental pollutants. Within the past decades, dioxin-like compounds (DLCs) such as polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons (PAHs) have attracted significant attention in the scientific community. To investigate the time- and concentration-dependent uptake of DLCs and PAHs in rainbow trout (Oncorhynchus mykiss) and their associated toxicological effects, we conducted exposure experiments using suspensions of three field-collected sediments from the rivers Rhine and Elbe, which were chosen to represent different contamination levels. Five serial dilutions of contaminated sediments were tested; these originated from the Prossen and Zollelbe sampling sites (both in the river Elbe, Germany) and from Ehrenbreitstein (Rhine, Germany), with lower levels of contamination. Fish were exposed to suspensions of these dilutions under semi-static conditions for 90 days. Analysis of muscle tissue by high resolution gas chromatography and mass spectrometry and of bile liquid by high-performance liquid chromatography showed that particle-bound PCDD/Fs, PCBs and PAHs were readily bioavailable from re-suspended sediments. Uptake of these contaminants and the associated toxicological effects in fish were largely proportional to their sediment concentrations. The changes in the investigated biomarkers closely reflected the different sediment contamination levels: cytochrome P450 1A mRNA expression and 7-ethoxyresorufin-O-deethylase activity in fish livers responded immediately and with high sensitivity, while increased frequencies of micronuclei and other nuclear aberrations, as well as histopathological and gross pathological lesions, were strong indicators of the potential long-term effects of re-suspension events. Our study clearly demonstrates that sediment re-suspension can lead to accumulation of PCDD/Fs and PCBs in fish, resulting in potentially adverse toxicological effects. For a sound risk assessment within the implementation of the European Water Framework Directive and related legislation, we propose a strong emphasis on sediment-bound contaminants in the context of integrated river basin management plans.
Resumo:
We analyzed more than 200 OSIRIS NAC images with a pixel scale of 0.9-2.4 m/pixel of comet 67P/Churyumov-Gerasimenko (67P) that have been acquired from onboard the Rosetta spacecraft in August and September 2014 using stereo-photogrammetric methods (SPG). We derived improved spacecraft position and pointing data for the OSIRIS images and a high-resolution shape model that consists of about 16 million facets (2 m horizontal sampling) and a typical vertical accuracy at the decimeter scale. From this model, we derive a volume for the northern hemisphere of 9.35 km(3) +/- 0.1 km(3). With the assumption of a homogeneous density distribution and taking into account the current uncertainty of the position of the comet's center-of-mass, we extrapolated this value to an overall volume of 18.7 km(3) +/- 1.2 km(3), and, with a current best estimate of 1.0 X 10(13) kg for the mass, we derive a bulk density of 535 kg/m(3) +/- 35 kg/m(3). Furthermore, we used SPG methods to analyze the rotational elements of 67P. The rotational period for August and September 2014 was determined to be 12.4041 +/- 0.0004 h. For the orientation of the rotational axis (z-axis of the body-fixed reference frame) we derived a precession model with a half-cone angle of 0.14 degrees, a cone center position at 69.54 degrees/64.11 degrees (RA/Dec J2000 equatorial coordinates), and a precession period of 10.7 days. For the definition of zero longitude (x-axis orientation), we finally selected the boulder-like Cheops feature on the big lobe of 67P and fixed its spherical coordinates to 142.35 degrees right-hand-rule eastern longitude and -0.28 degrees latitude. This completes the definition of the new Cheops reference frame for 67P. Finally, we defined cartographic mapping standards for common use and combined analyses of scientific results that have been obtained not only within the OSIRIS team, but also within other groups of the Rosetta mission.
Resumo:
With its wide coverage of economic spheres and the variety of trade and investment measures currently under negotiation, the Transatlantic Trade and Investment Partnership opens windows of opportunity for advancing action on climate change. We examine possible avenues and international trade law implications for an alignment of carbon-related standards between the EU and the US. We compare EU and US carbon emissions standards for cars and argue that negotiators should strive for a mutual recognition of their equivalence for a transitional period, while pursuing the goal of full harmonization at the level of the highest standards of two parties at some date in the future. This could be a way to balance between economic and environmental interests and harness economic incentives for the benefit of climate.
Resumo:
With its wide coverage of economic spheres and the variety of trade and investment measures currently under negotiation, the Transatlantic Trade and Investment Partnership (TTIP) opens windows of opportunity for climate change mitigation and adaptation. The paper examines the possible avenues and the WTO law implications for the alignment of emissions standards between the European Union (EU) and United States of America (US). Looking particularly at the automobile sector, it argues that TTIP negotiators should strive for the mutual recognition of equivalence of EU and US car emissions standards, while pursuing full harmonisation in the long term. It concludes that the preferential trade agreement (PTA) status of TTIP would not be able to exempt measures taken for regulatory convergence from compliance with applicable WTO rules, particularly the rules of the WTO’s Agreement on Technical Barriers to Trade (TBT). Furthermore, the EU and the US would not be able to ignore requests for the recognition of equivalence of third countries’ standards and would need to provide the grounds upon which they assess third countries’ standards as not adequately fulfilling the objectives of their own regulations and therefore rejecting them.