61 resultados para parallel processor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficient recognition of the pyrimidine base uracil by hypoxanthine or thymine in the parallel DNA triplex motif is based on the interplay of a conventional N−H⋅⋅⋅O and an unconventional C−H⋅⋅⋅O hydrogen bond.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long-term electrocardiogram (ECG) often suffers from relevant noise. Baseline wander in particular is pronounced in ECG recordings using dry or esophageal electrodes, which are dedicated for prolonged registration. While analog high-pass filters introduce phase distortions, reliable offline filtering of the baseline wander implies a computational burden that has to be put in relation to the increase in signal-to-baseline ratio (SBR). Here we present a graphics processor unit (GPU) based parallelization method to speed up offline baseline wander filter algorithms, namely the wavelet, finite, and infinite impulse response, moving mean, and moving median filter. Individual filter parameters were optimized with respect to the SBR increase based on ECGs from the Physionet database superimposed to auto-regressive modeled, real baseline wander. A Monte-Carlo simulation showed that for low input SBR the moving median filter outperforms any other method but negatively affects ECG wave detection. In contrast, the infinite impulse response filter is preferred in case of high input SBR. However, the parallelized wavelet filter is processed 500 and 4 times faster than these two algorithms on the GPU, respectively, and offers superior baseline wander suppression in low SBR situations. Using a signal segment of 64 mega samples that is filtered as entire unit, wavelet filtering of a 7-day high-resolution ECG is computed within less than 3 seconds. Taking the high filtering speed into account, the GPU wavelet filter is the most efficient method to remove baseline wander present in long-term ECGs, with which computational burden can be strongly reduced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Biomarkers are a promising tool for the management of patients with atherosclerosis, but their variation is largely unknown. We assessed within-subject and between-subject biological variation of biomarkers in peripheral artery disease (PAD) patients and healthy controls, and defined which biomarkers have a favorable variation profile for future studies. METHODS Prospective, parallel-group cohort study, including 62 patients with stable PAD (79% men, 65±7years) and 18 healthy control subjects (44% men, 57±7years). Blood samples were taken at baseline, and after 3-, 6-, and 12-months. We calculated within-subject (CVI) and between-subject (CVG) coefficients of variation and intra-class correlation coefficient (ICC). RESULTS Mean levels of D-dimer, hs-CRP, IL-6, IL-8, MMP-9, MMP-3, S100A8/A9, PAI-1, sICAM-1, and sP-selectin levels were higher in PAD patients than in healthy controls (P≤.05 for all). CVI and CVG of the different biomarkers varied considerably in both groups. An ICC≥0.5 (indicating moderate-to-good reliability) was found for hs-CRP, D-Dimer, E-selectin, IL-10, MCP-1, MMP-3, oxLDL, sICAM-1 and sP-selectin in both groups, for sVCAM in healthy controls and for MMP-9, PAI-1 and sCD40L in PAD patients. CONCLUSIONS Single biomarker measurements are of limited utility due to large within-subject variation, both in PAD patients and healthy subjects. D-dimer, hs-CRP, MMP-9, MMP-3, PAI-1, sP-selectin and sICAM-1 are biomarkers with both higher mean levels in PAD patients and a favorable variation profile making them most suitable for future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The Rondo is a single-unit cochlear implant (CI) audio processor comprising the identical components as its behind-the-ear predecessor, the Opus 2. An interchange of the Opus 2 with the Rondo leads to a shift of the microphone position toward the back of the head. This study aimed to investigate the influence of the Rondo wearing position on speech intelligibility in noise. METHODS Speech intelligibility in noise was measured in 4 spatial configurations with 12 experienced CI users using the German adaptive Oldenburg sentence test. A physical model and a numerical model were used to enable a comparison of the observations. RESULTS No statistically significant differences of the speech intelligibility were found in the situations in which the signal came from the front and the noise came from the frontal, ipsilateral, or contralateral side. The signal-to-noise ratio (SNR) was significantly better with the Opus 2 in the case with the noise presented from the back (4.4 dB, p < 0.001). The differences in the SNR were significantly worse with the Rondo processors placed further behind the ear than closer to the ear. CONCLUSION The study indicates that CI users with the receiver/stimulator implanted in positions further behind the ear are expected to have higher difficulties in noisy situations when wearing the single-unit audio processor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate parallel algorithms for the solution of the Navier–Stokes equations in space-time. For periodic solutions, the discretized problem can be written as a large non-linear system of equations. This system of equations is solved by a Newton iteration. The Newton correction is computed using a preconditioned GMRES solver. The parallel performance of the algorithm is illustrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Specialization to nectarivory is associated with radiations within different bird groups, including parrots. One of them, the Australasian lories, were shown to be unexpectedly species rich. Their shift to nectarivory may have created an ecological opportunity promoting species proliferation. Several morphological specializations of the feeding tract to nectarivory have been described for parrots. However, they have never been assessed in a quantitative framework considering phylogenetic nonindependence. Using a phylogenetic comparative approach with broad taxon sampling and 15 continuous characters of the digestive tract, we demonstrate that nectarivorous parrots differ in several traits from the remaining parrots. These trait-changes indicate phenotype–environment correlations and parallel evolution, and may reflect adaptations to feed effectively on nectar. Moreover, the diet shift was associated with significant trait shifts at the base of the radiation of the lories, as shown by an alternative statistical approach. Their diet shift might be considered as an evolutionary key innovation which promoted significant non-adaptive lineage diversification through allopatric partitioning of the same new niche. The lack of increased rates of cladogenesis in other nectarivorous parrots indicates that evolutionary innovations need not be associated one-to-one with diversification events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the speech intelligibility in noise with a new cochlear implant (CI) processor that uses a pinna effect imitating directional microphone system. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Ten experienced, unilateral CI recipients with bilateral severe-to-profound hearing loss. INTERVENTION All participants performed speech in noise tests with the Opus 2 processor (omnidirectional microphone mode only) and the newer Sonnet processor (omnidirectional and directional microphone mode). MAIN OUTCOME MEASURE The speech reception threshold (SRT) in noise was measured in four spatial settings. The test sentences were always presented from the front. The noise was arriving either from the front (S0N0), the ipsilateral side of the CI (S0NIL), the contralateral side of the CI (S0NCL), or the back (S0N180). RESULTS The directional mode improved the SRTs by 3.6 dB (p < 0.01), 2.2 dB (p < 0.01), and 1.3 dB (p < 0.05) in the S0N180, S0NIL, and S0NCL situations, when compared with the Sonnet in the omnidirectional mode. There was no statistically significant difference in the S0N0 situation. No differences between the Opus 2 and the Sonnet in the omnidirectional mode were observed. CONCLUSION Speech intelligibility with the Sonnet system was statistically different to speech recognition with the Opus 2 system suggesting that CI users might profit from the pinna effect imitating directionality mode in noisy environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we question the homogeneity of a large parallel corpus by measuring the similarity between various sub-parts. We compare results obtained using a general measure of lexical similarity based on χ2 and by counting the number of discourse connectives. We argue that discourse connectives provide a more sensitive measure, revealing differences that are not visible with the general measure. We also provide evidence for the existence of specific characteristics defining translated texts as opposed to non-translated ones, due to a universal tendency for explicitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a parallel surrogate-based global optimization method for computationally expensive objective functions that is more effective for larger numbers of processors. To reach this goal, we integrated concepts from multi-objective optimization and tabu search into, single objective, surrogate optimization. Our proposed derivative-free algorithm, called SOP, uses non-dominated sorting of points for which the expensive function has been previously evaluated. The two objectives are the expensive function value of the point and the minimum distance of the point to previously evaluated points. Based on the results of non-dominated sorting, P points from the sorted fronts are selected as centers from which many candidate points are generated by random perturbations. Based on surrogate approximation, the best candidate point is subsequently selected for expensive evaluation for each of the P centers, with simultaneous computation on P processors. Centers that previously did not generate good solutions are tabu with a given tenure. We show almost sure convergence of this algorithm under some conditions. The performance of SOP is compared with two RBF based methods. The test results show that SOP is an efficient method that can reduce time required to find a good near optimal solution. In a number of cases the efficiency of SOP is so good that SOP with 8 processors found an accurate answer in less wall-clock time than the other algorithms did with 32 processors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Oesophageal clearance has been scarcely studied. AIMS Oesophageal clearance in endoscopy-negative heartburn was assessed to detect differences in bolus clearance time among patients sub-grouped according to impedance-pH findings. METHODS In 118 consecutive endoscopy-negative heartburn patients impedance-pH monitoring was performed off-therapy. Acid exposure time, number of refluxes, baseline impedance, post-reflux swallow-induced peristaltic wave index and both automated and manual bolus clearance time were calculated. Patients were sub-grouped into pH/impedance positive (abnormal acid exposure and/or number of refluxes) and pH/impedance negative (normal acid exposure and number of refluxes), the former further subdivided on the basis of abnormal/normal acid exposure time (pH+/-) and abnormal/normal number of refluxes (impedance+/-). RESULTS Poor correlation (r=0.35) between automated and manual bolus clearance time was found. Manual bolus clearance time progressively decreased from pH+/impedance+ (42.6s), pH+/impedance- (27.1s), pH-/impedance+ (17.8s) to pH-/impedance- (10.8s). There was an inverse correlation between manual bolus clearance time and both baseline impedance and post-reflux swallow-induced peristaltic wave index, and a direct correlation between manual bolus clearance and acid exposure time. A manual bolus clearance time value of 14.8s had an accuracy of 93% to differentiate pH/impedance positive from pH/impedance negative patients. CONCLUSIONS When manually measured, bolus clearance time reflects reflux severity, confirming the pathophysiological relevance of oesophageal clearance in reflux disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Primary care physicians (PCPs) should prescribe faecal immunochemical testing (FIT) or colonoscopy for colorectal cancer screening based on their patient's values and preferences. However, there are wide variations between PCPs in the screening method prescribed. The objective was to assess the impact of an educational intervention on PCPs' intent to offer FIT or colonoscopy on an equal basis. DESIGN Survey before and after training seminars, with a parallel comparison through a mailed survey to PCPs not attending the training seminars. SETTING All PCPs in the canton of Vaud, Switzerland. PARTICIPANTS Of 592 eligible PCPs, 133 (22%) attended a seminar and 106 (80%) filled both surveys. 109 (24%) PCPs who did not attend the seminars returned the mailed survey. INTERVENTION A 2 h-long interactive seminar targeting PCP knowledge, skills and attitudes regarding offering a choice of colorectal cancer (CRC) screening options. OUTCOME MEASURES The primary outcome was PCP intention of having their patients screened with FIT and colonoscopy in equal proportions (between 40% and 60% each). Secondary outcomes were the perceived role of PCPs in screening decisions (from paternalistic to informed decision-making) and correct answer to a clinical vignette. RESULTS Before the seminars, 8% of PCPs reported that they had equal proportions of their patients screened for CRC by FIT and colonoscopy; after the seminar, 33% foresaw having their patients screened in equal proportions (p<0.001). Among those not attending, there was no change (13% vs 14%, p=0.8). Of those attending, there was no change in their perceived role in screening decisions, while the proportion responding correctly to a clinical vignette increased (88-99%, p<0.001). CONCLUSIONS An interactive training seminar increased the proportion of physicians with the intention to prescribe FIT and colonoscopy in equal proportions.

Relevância:

20.00% 20.00%

Publicador: