55 resultados para Medical surgical units
Resumo:
IMPORTANCE Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES Survival, stroke, and New York Heart Association functional class. RESULTS Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.
Resumo:
PRINCIPLES Thyroidectomy in children is rare and mostly performed because of thyroid neoplasms. The aim of this study based on prospective data acquisition was to evaluate whether thyroid surgery in children can be performed as safely as in adults when undertaken by a team of adult endocrine surgeons and paediatric surgeons. METHODS Between 2002 and 2012, 36 patients younger than 18 years underwent surgery for thyroid gland pathologies. All surgical procedures were performed by an experienced endocrine surgeon and a paediatric surgeon. Baseline demographic data, surgical procedure, duration of operation, length of hospital stay, and postoperative morbidity and mortality were analysed. RESULTS The median age of all patients was 13 years (range 2-17 years), with predominantly female gender (n = 30, 83%). The majority of operations were performed because of benign thyroid disease (n = 27, 75%) and only a minority because of malignancy or genetic abnormality with predisposition for malignant transformation (MEN) (n = 9, 25%). Total thyroidectomy was performed in the majority of the patients (n = 24, 67%). The median duration of the surgical procedure was 153 minutes (range 90-310 minutes). The median hospital stay was 5 days (3-1 days). One patient developed persistent hypoparathyroidism after neck dissection due to cancer. One persistent and two temporary recurrent nerve palsies occurred. CONCLUSION This study demonstrated that paediatric thyroidectomy is safe as performed by this team of endocrine and paediatric surgeons, with acceptable morbidity even when total thyroidectomy was performed in the case of benign disease.
Resumo:
INTRODUCTION Faecal peritonitis (FP) is a common cause of sepsis and admission to the intensive care unit (ICU). The Genetics of Sepsis and Septic Shock in Europe (GenOSept) project is investigating the influence of genetic variation on the host response and outcomes in a large cohort of patients with sepsis admitted to ICUs across Europe. Here we report an epidemiological survey of the subset of patients with FP. OBJECTIVES To define the clinical characteristics, outcomes and risk factors for mortality in patients with FP admitted to ICUs across Europe. METHODS Data was extracted from electronic case report forms. Phenotypic data was recorded using a detailed, quality-assured clinical database. The primary outcome measure was 6-month mortality. Patients were followed for 6 months. Kaplan-Meier analysis was used to determine mortality rates. Cox proportional hazards regression analysis was employed to identify independent risk factors for mortality. RESULTS Data for 977 FP patients admitted to 102 centres across 16 countries between 29 September 2005 and 5 January 2011 was extracted. The median age was 69.2 years (IQR 58.3-77.1), with a male preponderance (54.3%). The most common causes of FP were perforated diverticular disease (32.1%) and surgical anastomotic breakdown (31.1%). The ICU mortality rate at 28 days was 19.1%, increasing to 31.6% at 6 months. The cause of FP, pre-existing co-morbidities and time from estimated onset of symptoms to surgery did not impact on survival. The strongest independent risk factors associated with an increased rate of death at 6 months included age, higher APACHE II score, acute renal and cardiovascular dysfunction within 1 week of admission to ICU, hypothermia, lower haematocrit and bradycardia on day 1 of ICU stay. CONCLUSIONS In this large cohort of patients admitted to European ICUs with FP the 6 month mortality was 31.6%. The most consistent predictors of mortality across all time points were increased age, development of acute renal dysfunction during the first week of admission, lower haematocrit and hypothermia on day 1 of ICU admission.
Resumo:
In this chapter a low-cost surgical navigation solution for periacetabular osteotomy (PAO) surgery is described. Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient’s pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient’s anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient’s pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography (CT) scan is used to visualize the updated orientation of the acetabular fragment. Experiments with plastic bones (7 hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistical difference on the measurement of acetabular component reorientation (anteversion and inclination). In six out of seven hip joints the mean absolute difference was below five degrees for both anteversion and inclination.
Resumo:
BACKGROUND: Learning surgical skills in the operating room may be a challenge for medical students. Therefore, more approaches using simulation to enable students to develop their practical skills are required. OBJECTIVES: We hypothesized that (1) there would be a need for additional surgical training for medical students in the pre-final year, and (2) our basic surgery skills training program using fresh human skin would improve medical students' surgical skills. DESIGN: We conducted a preliminary survey of medical students to clarify the need for further training in basic surgery procedures. A new approach using simulation to teach surgical skills on human skin was set up. The procedural skills of 15 randomly selected students were assessed in the operating room before and after participation in the simulation, using Objective Structured Assessment of Technical Skills. Furthermore, subjective assessment was performed based on students' self-evaluation. The data were analyzed using SPSS, version 21 (SPSS, Inc., Chicago, IL). SETTING: The study took place at the Inselspital, Bern University Hospital. PARTICIPANTS: A total of 186 pre-final-year medical students were enrolled into the preliminary survey; 15 randomly selected medical students participated in the basic surgical skills training course on the fresh human skin operating room. RESULTS: The preliminary survey revealed the need for a surgical skills curriculum. The simulation approach we developed showed significant (p < 0.001) improvement for all 12 surgical skills, with mean cumulative precourse and postcourse values of 31.25 ± 5.013 and 45.38 ± 3.557, respectively. The self-evaluation contained positive feedback as well. CONCLUSION: Simulation of surgery using human tissue samples could help medical students become more proficient in handling surgical instruments before stepping into a real surgical situation. We suggest further studies evaluating our proposed teaching method and the possibility of integrating this simulation approach into the medical school curriculum.
Resumo:
UNLABELLED OBJECTIVE; Virtual autopsy methods, such as postmortem CT and MRI, are increasingly being used in forensic medicine. Forensic investigators with little to no training in diagnostic radiology and medical laypeople such as state's attorneys often find it difficult to understand the anatomic orientation of axial postmortem CT images. We present a computer-assisted system that permits postmortem CT datasets to be quickly and intuitively resliced in real time at the body to narrow the gap between radiologic imaging and autopsy. CONCLUSION Our system is a potentially valuable tool for planning autopsies, showing findings to medical laypeople, and teaching CT anatomy, thus further closing the gap between radiology and forensic pathology.
Resumo:
PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.
Resumo:
BACKGROUND Although surgery represents the cornerstone treatment of endometrial cancer at initial diagnosis, scarce data are available in recurrent setting. The purpose of this study was to review the outcome of surgery in these patients. METHODS Medical records of all patients undergoing surgery for recurrent endometrial cancer at NCI Milano between January 2003 and January 2014 were reviewed. Survival was determined from the time of surgery for recurrence to last follow-up. Survival was estimated using Kaplan-Meier methods. Differences in survival were analyzed using the log-rank test. The Fisher's exact test was used to compare optimal versus suboptimal cytoreduction against possible predictive factors. RESULTS Sixty-four patients were identified. Median age was 66 years. Recurrences were multiple in 38 % of the cases. Optimal cytoreduction was achieved in 65.6 %. Median OR time was 165 min, median postoperative hemoglobin drop was 2.4 g/dl, and median length hospital stay was 5.5 days. Eleven patients developed postoperative complications, but only four required surgical management. Estimated 5-year progression-free survival (PFS) was 42 and 19 % in optimally and suboptimally cytoreduced patients, respectively. At multivariate analysis, only residual disease was associated with PFS. Estimated 5-year overall survival (OS) was 60 and 30 % in optimally and suboptimally cytoreduced patients, respectively. At multivariate analysis, residual disease and histotype were associated with OS. At multivariate analysis, only performance status was associated with optimal cytoreduction. CONCLUSIONS Secondary cytoreduction in endometrial cancer is associated with long PFS and OS. The only factors associated with improved long-term outcome are the absence of residual disease at the end of surgical resection and histotype.
Resumo:
Nucleus pulposus replacements have been subjected to highly controversial discussions over the last 40 years. Their use has not yet resulted in a positive outcome to treat herniated disc or degenerated disc disease. The main reason is that not a single implant or tissue replacement was able to withstand the loads within an intervertebral disc. Here, we report on the development of a photo-polymerizable poly(ethylene glycol)dimethacrylate nano-fibrillated cellulose composite hydrogel which was tuned according to native tissue properties. Using a customized minimally-invasive medical device to inject and photopolymerize the hydrogel insitu, samples were implanted through an incision of 1 mm into an intervertebral disc of a bovine organ model to evaluate their long-term performance. When implanted into the bovine disc model, the composite hydrogel implant was able to significantly re-establish disc height after surgery (p < 0.0025). The height was maintained after 0.5 million loading cycles (p < 0.025). The mechanical resistance of the novel composite hydrogel material combined with the minimally invasive implantation procedure into a bovine disc resulted in a promising functional orthopedic implant for the replacement of the nucleus pulposus.
Resumo:
Heater-cooler units (HCUs) were recently identified as a source of Mycobacterium chimaera causing surgical site infections. We investigated transmission of this bacterium from HCUs to the surgical field by using a thermic anemometer and particle counter, videotape of an operating room equipped with an ultraclean laminar airflow ventilation system, and bacterial culture sedimentation plates in a nonventilated room. Smoke from the HCU reached the surgical field in 23 s by merging with ultraclean air. The HCU produced on average 5.2, 139, and 14.8 particles/min in the surgical field at positions Off, On/oriented toward, and On/oriented away, respectively. Culture plates were positive for M. chimaera <5 m from the HCU in the test room. These experiments confirm airborne transmission of M. chimaera aerosols from a contaminated HCU to an open surgical field despite ultraclean air ventilation. Efforts to mitigate infectious risks during surgery should consider contamination from water sources and airflow-generating devices.