60 resultados para Malvasia, Carlo Cesare, conte, 1616-1693.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). METHODS As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. RESULTS The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V95% increased from 90% to 96% and V107% decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. CONCLUSIONS MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Modulated electron radiotherapy (MERT) promises sparing of organs at risk for certain tumor sites. Any implementation of MERT treatment planning requires an accurate beam model. The aim of this work is the development of a beam model which reconstructs electron fields shaped using the Millennium photon multileaf collimator (MLC) (Varian Medical Systems, Inc., Palo Alto, CA) for a Varian linear accelerator (linac). METHODS This beam model is divided into an analytical part (two photon and two electron sources) and a Monte Carlo (MC) transport through the MLC. For dose calculation purposes the beam model has been coupled with a macro MC dose calculation algorithm. The commissioning process requires a set of measurements and precalculated MC input. The beam model has been commissioned at a source to surface distance of 70 cm for a Clinac 23EX (Varian Medical Systems, Inc., Palo Alto, CA) and a TrueBeam linac (Varian Medical Systems, Inc., Palo Alto, CA). For validation purposes, measured and calculated depth dose curves and dose profiles are compared for four different MLC shaped electron fields and all available energies. Furthermore, a measured two-dimensional dose distribution for patched segments consisting of three 18 MeV segments, three 12 MeV segments, and a 9 MeV segment is compared with corresponding dose calculations. Finally, measured and calculated two-dimensional dose distributions are compared for a circular segment encompassed with a C-shaped segment. RESULTS For 15 × 34, 5 × 5, and 2 × 2 cm(2) fields differences between water phantom measurements and calculations using the beam model coupled with the macro MC dose calculation algorithm are generally within 2% of the maximal dose value or 2 mm distance to agreement (DTA) for all electron beam energies. For a more complex MLC pattern, differences between measurements and calculations are generally within 3% of the maximal dose value or 3 mm DTA for all electron beam energies. For the two-dimensional dose comparisons, the differences between calculations and measurements are generally within 2% of the maximal dose value or 2 mm DTA. CONCLUSIONS The results of the dose comparisons suggest that the developed beam model is suitable to accurately reconstruct photon MLC shaped electron beams for a Clinac 23EX and a TrueBeam linac. Hence, in future work the beam model will be utilized to investigate the possibilities of MERT using the photon MLC to shape electron beams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This bipartite comparative study aims at inspecting the similarities and differences between the Jones and Stokes–Mueller formalisms when modeling polarized light propagation with numerical simulations of the Monte Carlo type. In this first part, we review the theoretical concepts that concern light propagation and detection with both pure and partially/totally unpolarized states. The latter case involving fluctuations, or “depolarizing effects,” is of special interest here: Jones and Stokes–Mueller are equally apt to model such effects and are expected to yield identical results. In a second, ensuing paper, empirical evidence is provided by means of numerical experiments, using both formalisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this second part of our comparative study inspecting the (dis)similarities between “Stokes” and “Jones,” we present simulation results yielded by two independent Monte Carlo programs: (i) one developed in Bern with the Jones formalism and (ii) the other implemented in Ulm with the Stokes notation. The simulated polarimetric experiments involve suspensions of polystyrene spheres with varying size. Reflection and refraction at the sample/air interfaces are also considered. Both programs yield identical results when propagating pure polarization states, yet, with unpolarized illumination, second order statistical differences appear, thereby highlighting the pre-averaged nature of the Stokes parameters. This study serves as a validation for both programs and clarifies the misleading belief according to which “Jones cannot treat depolarizing effects.”

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND It is unclear whether radial compared with femoral access improves outcomes in unselected patients with acute coronary syndromes undergoing invasive management. METHODS We did a randomised, multicentre, superiority trial comparing transradial against transfemoral access in patients with acute coronary syndrome with or without ST-segment elevation myocardial infarction who were about to undergo coronary angiography and percutaneous coronary intervention. Patients were randomly allocated (1:1) to radial or femoral access with a web-based system. The randomisation sequence was computer generated, blocked, and stratified by use of ticagrelor or prasugrel, type of acute coronary syndrome (ST-segment elevation myocardial infarction, troponin positive or negative, non-ST-segment elevation acute coronary syndrome), and anticipated use of immediate percutaneous coronary intervention. Outcome assessors were masked to treatment allocation. The 30-day coprimary outcomes were major adverse cardiovascular events, defined as death, myocardial infarction, or stroke, and net adverse clinical events, defined as major adverse cardiovascular events or Bleeding Academic Research Consortium (BARC) major bleeding unrelated to coronary artery bypass graft surgery. The analysis was by intention to treat. The two-sided α was prespecified at 0·025. The trial is registered at ClinicalTrials.gov, number NCT01433627. FINDINGS We randomly assigned 8404 patients with acute coronary syndrome, with or without ST-segment elevation, to radial (4197) or femoral (4207) access for coronary angiography and percutaneous coronary intervention. 369 (8·8%) patients with radial access had major adverse cardiovascular events, compared with 429 (10·3%) patients with femoral access (rate ratio [RR] 0·85, 95% CI 0·74-0·99; p=0·0307), non-significant at α of 0·025. 410 (9·8%) patients with radial access had net adverse clinical events compared with 486 (11·7%) patients with femoral access (0·83, 95% CI 0·73-0·96; p=0·0092). The difference was driven by BARC major bleeding unrelated to coronary artery bypass graft surgery (1·6% vs 2·3%, RR 0·67, 95% CI 0·49-0·92; p=0·013) and all-cause mortality (1·6% vs 2·2%, RR 0·72, 95% CI 0·53-0·99; p=0·045). INTERPRETATION In patients with acute coronary syndrome undergoing invasive management, radial as compared with femoral access reduces net adverse clinical events, through a reduction in major bleeding and all-cause mortality. FUNDING The Medicines Company and Terumo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The numerical simulations of the magnetic properties of extended three-dimensional networks containing M(II) ions with an S = 5/2 ground-state spin have been carried out within the framework of the isotropic Heisenberg model. Analytical expressions fitting the numerical simulations for the primitive cubic, diamond, together with (10−3) cubic networks have all been derived. With these empirical formulas in hands, we can now extract the interaction between the magnetic ions from the experimental data for these networks. In the case of the primitive cubic network, these expressions are directly compared with those from the high-temperature expansions of the partition function. A fit of the experimental data for three complexes, namely [(N(CH3)4][Mn(N3)] 1, [Mn(CN4)]n 2, and [FeII(bipy)3][MnII2(ox)3] 3, has been carried out. The best fits were those obtained using the following parameters, J = −3.5 cm-1, g = 2.01 (1); J = −8.3 cm-1, g = 1.95 (2); and J = −2.0 cm-1, g = 1.95 (3).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Palaeoclimatic information can be retrieved from the diffusion of the stable water isotope signal during firnification of snow. The diffusion length, a measure for the amount of diffusion a layer has experienced, depends on the firn temperature and the accumulation rate. We show that the estimation of the diffusion length using power spectral densities (PSDs) of the record of a single isotope species can be biased by uncertainties in spectral properties of the isotope signal prior to diffusion. By using a second water isotope and calculating the difference in diffusion lengths between the two isotopes, this problem is circumvented. We study the PSD method applied to two isotopes in detail and additionally present a new forward diffusion method for retrieving the differential diffusion length based on the Pearson correlation between the two isotope signals. The two methods are discussed and extensively tested on synthetic data which are generated in a Monte Carlo manner. We show that calibration of the PSD method with this synthetic data is necessary to be able to objectively determine the differential diffusion length. The correlation-based method proves to be a good alternative for the PSD method as it yields precision equal to or somewhat higher than the PSD method. The use of synthetic data also allows us to estimate the accuracy and precision of the two methods and to choose the best sampling strategy to obtain past temperatures with the required precision. In addition to application to synthetic data the two methods are tested on stable-isotope records from the EPICA (European Project for Ice Coring in Antarctica) ice core drilled in Dronning Maud Land, Antarctica, showing that reliable firn temperatures can be reconstructed with a typical uncertainty of 1.5 and 2 °C for the Holocene period and 2 and 2.5 °C for the last glacial period for the correlation and PSD method, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Conflicting evidence exists on the efficacy and safety of bivalirudin administered as part of percutaneous coronary intervention (PCI) in patients with an acute coronary syndrome. Methods We randomly assigned 7213 patients with an acute coronary syndrome for whom PCI was anticipated to receive either bivalirudin or unfractionated heparin. Patients in the bivalirudin group were subsequently randomly assigned to receive or not to receive a post-PCI bivalirudin infusion. Primary outcomes for the comparison between bivalirudin and heparin were the occurrence of major adverse cardiovascular events (a composite of death, myocardial infarction, or stroke) and net adverse clinical events (a composite of major bleeding or a major adverse cardiovascular event). The primary outcome for the comparison of a post-PCI bivalirudin infusion with no post-PCI infusion was a composite of urgent target-vessel revascularization, definite stent thrombosis, or net adverse clinical events. Results The rate of major adverse cardiovascular events was not significantly lower with bivalirudin than with heparin (10.3% and 10.9%, respectively; relative risk, 0.94; 95% confidence interval [CI], 0.81 to 1.09; P=0.44), nor was the rate of net adverse clinical events (11.2% and 12.4%, respectively; relative risk, 0.89; 95% CI, 0.78 to 1.03; P=0.12). Post-PCI bivalirudin infusion, as compared with no infusion, did not significantly decrease the rate of urgent target-vessel revascularization, definite stent thrombosis, or net adverse clinical events (11.0% and 11.9%, respectively; relative risk, 0.91; 95% CI, 0.74 to 1.11; P=0.34). Conclusions In patients with an acute coronary syndrome, the rates of major adverse cardiovascular events and net adverse clinical events were not significantly lower with bivalirudin than with unfractionated heparin. The rate of the composite of urgent target-vessel revascularization, definite stent thrombosis, or net adverse clinical events was not significantly lower with a post-PCI bivalirudin infusion than with no post-PCI infusion. (Funded by the Medicines Company and Terumo Medical; MATRIX ClinicalTrials.gov number, NCT01433627 .).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last years, the interest in proton radiotherapy is rapidly increasing. Protons provide superior physical properties compared with conventional radiotherapy using photons. These properties result in depth dose curves with a large dose peak at the end of the proton track and the finite proton range allows sparing the distally located healthy tissue. These properties offer an increased flexibility in proton radiotherapy, but also increase the demand in accurate dose estimations. To carry out accurate dose calculations, first an accurate and detailed characterization of the physical proton beam exiting the treatment head is necessary for both currently available delivery techniques: scattered and scanned proton beams. Since Monte Carlo (MC) methods follow the particle track simulating the interactions from first principles, this technique is perfectly suited to accurately model the treatment head. Nevertheless, careful validation of these MC models is necessary. While for the dose estimation pencil beam algorithms provide the advantage of fast computations, they are limited in accuracy. In contrast, MC dose calculation algorithms overcome these limitations and due to recent improvements in efficiency, these algorithms are expected to improve the accuracy of the calculated dose distributions and to be introduced in clinical routine in the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monte Carlo integration is firmly established as the basis for most practical realistic image synthesis algorithms because of its flexibility and generality. However, the visual quality of rendered images often suffers from estimator variance, which appears as visually distracting noise. Adaptive sampling and reconstruction algorithms reduce variance by controlling the sampling density and aggregating samples in a reconstruction step, possibly over large image regions. In this paper we survey recent advances in this area. We distinguish between “a priori” methods that analyze the light transport equations and derive sampling rates and reconstruction filters from this analysis, and “a posteriori” methods that apply statistical techniques to sets of samples to drive the adaptive sampling and reconstruction process. They typically estimate the errors of several reconstruction filters, and select the best filter locally to minimize error. We discuss advantages and disadvantages of recent state-of-the-art techniques, and provide visual and quantitative comparisons. Some of these techniques are proving useful in real-world applications, and we aim to provide an overview for practitioners and researchers to assess these approaches. In addition, we discuss directions for potential further improvements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the ongoing shift in the computer graphics industry toward Monte Carlo rendering, there is a need for effective, practical noise-reduction techniques that are applicable to a wide range of rendering effects and easily integrated into existing production pipelines. This course surveys recent advances in image-space adaptive sampling and reconstruction algorithms for noise reduction, which have proven very effective at reducing the computational cost of Monte Carlo techniques in practice. These approaches leverage advanced image-filtering techniques with statistical methods for error estimation. They are attractive because they can be integrated easily into conventional Monte Carlo rendering frameworks, they are applicable to most rendering effects, and their computational overhead is modest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We model Callisto's exosphere based on its ice as well as non-ice surface via the use of a Monte-Carlo exosphere model. For the ice component we implement two putative compositions that have been computed from two possible extreme formation scenarios of the satellite. One composition represents the oxidizing state and is based on the assumption that the building blocks of Callisto were formed in the protosolar nebula and the other represents the reducing state of the gas, based on the assumption that the satellite accreted from solids condensed in the jovian sub-nebula. For the non-ice component we implemented the compositions of typical CI as well as L type chondrites. Both chondrite types have been suggested to represent Callisto's non-ice composition best. As release processes we consider surface sublimation, ion sputtering and photon-stimulated desorption. Particles are followed on their individual trajectories until they either escape Callisto's gravitational attraction, return to the surface, are ionized, or are fragmented. Our density profiles show that whereas the sublimated species dominate close to the surface on the sun-lit side, their density profiles (with the exception of H and H-2) decrease much more rapidly than the sputtered particles. The Neutral gas and Ion Mass (NIM) spectrometer, which is part of the Particle Environment Package (PEP), will investigate Callisto's exosphere during the JUICE mission. Our simulations show that NIM will be able to detect sublimated and sputtered particles from both the ice and non-ice surface. NIM's measured chemical composition will allow us to distinguish between different formation scenarios. (C) 2015 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct Simulation Monte Carlo (DSMC) is a powerful numerical method to study rarefied gas flows such as cometary comae and has been used by several authors over the past decade to study cometary outflow. However, the investigation of the parameter space in simulations can be time consuming since 3D DSMC is computationally highly intensive. For the target of ESA's Rosetta mission, comet 67P/Churyumov-Gerasimenko, we have identified to what extent modification of several parameters influence the 3D flow and gas temperature fields and have attempted to establish the reliability of inferences about the initial conditions from in situ and remote sensing measurements. A large number of DSMC runs have been completed with varying input parameters. In this work, we present the simulation results and conclude on the sensitivity of solutions to certain inputs. It is found that among cases of water outgassing, the surface production rate distribution is the most influential variable to the flow field.

Relevância:

20.00% 20.00%

Publicador: