71 resultados para Imaging, Three-Dimensional


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: This study investigates by means of a new bone-prosthesis interface motion detector whether conceptual design differences of femoral stems are reflected in their primary stability pattern. DESIGN: An in vitro experiment using a biaxial materials testing machine in combination with three-dimensional motion measurement devices was performed. BACKGROUND: Primary stability of uncemented total hip replacements is considered to be a prerequisite for the quality of bony ongrowth to the femoral stem. Dynamic motion as a response to loading as well as total motion of the prosthesis have to be considered under quasi-physiological cyclic loading conditions. METHODS: Seven paired fresh cadaveric femora were used for the testing of two types of uncemented femoral stems with different anchoring concepts: CLS stem (Spotorno) and Cone Prosthesis (Wagner). Under sinusoidal cyclic loading mimicking in vivo hip joint forces a new measurement technique was applied allowing for the analysis of the three-dimensional interface motion. RESULTS: Considerable differences between the two prostheses could be detected both in their dynamic motion and total motion behaviour. Whereas the CLS stem, due to the wedge-shaped concept, provides smaller total motions, the longitudinal ribs of the Cone prostheses result in a substantially smaller dynamic motion. CONCLUSIONS: The measuring technique provided reliable and accurate data illustrating the three-dimensional interface motion of uncemented femoral stems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Arm hemiparesis secondary to stroke is common and disabling. We aimed to assess whether robotic training of an affected arm with ARMin--an exoskeleton robot that allows task-specific training in three dimensions-reduces motor impairment more effectively than does conventional therapy. METHODS: In a prospective, multicentre, parallel-group randomised trial, we enrolled patients who had had motor impairment for more than 6 months and moderate-to-severe arm paresis after a cerebrovascular accident who met our eligibility criteria from four centres in Switzerland. Eligible patients were randomly assigned (1:1) to receive robotic or conventional therapy using a centre-stratified randomisation procedure. For both groups, therapy was given for at least 45 min three times a week for 8 weeks (total 24 sessions). The primary outcome was change in score on the arm (upper extremity) section of the Fugl-Meyer assessment (FMA-UE). Assessors tested patients immediately before therapy, after 4 weeks of therapy, at the end of therapy, and 16 weeks and 34 weeks after start of therapy. Assessors were masked to treatment allocation, but patients, therapists, and data analysts were unmasked. Analyses were by modified intention to treat. This study is registered with ClinicalTrials.gov, number NCT00719433. FINDINGS: Between May 4, 2009, and Sept 3, 2012, 143 individuals were tested for eligibility, of whom 77 were eligible and agreed to participate. 38 patients assigned to robotic therapy and 35 assigned to conventional therapy were included in analyses. Patients assigned to robotic therapy had significantly greater improvements in motor function in the affected arm over the course of the study as measured by FMA-UE than did those assigned to conventional therapy (F=4.1, p=0.041; mean difference in score 0.78 points, 95% CI 0.03-1.53). No serious adverse events related to the study occurred. INTERPRETATION: Neurorehabilitation therapy including task-oriented training with an exoskeleton robot can enhance improvement of motor function in a chronically impaired paretic arm after stroke more effectively than conventional therapy. However, the absolute difference between effects of robotic and conventional therapy in our study was small and of weak significance, which leaves the clinical relevance in question.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Resternotomy for aortic valve replacement in patients with previous coronary artery bypass grafting and an internal mammary artery graft may be a surgical problem. Thus, we are exploring the effect of using rapid prototyping techniques for surgical planning and intraoperative orientation during aortic valve replacement after previous coronary artery bypass grafting (CABG). DESCRIPTION As a proof of concept, we studied a patient who had undergone CABG 5 years earlier. At that time the patient received a left internal mammary artery graft to the left anterior descending artery and a venous graft to the right coronary artery. Now the patient required aortic valve replacement due to symptomatic aortic valve stenosis. The left internal mammary artery bypass and the right coronary artery bypass were patent and showed good flow in the angiography. The patient was examined by 128-slice computed tomography. The image data were visualized and reconstructed. Afterwards, a replica showing the anatomic structures was fabricated using a rapid prototyping machine. EVALUATION Using data derived from 128-slice computed tomography angiography linked to proprietary software, we were able to create three-dimensional reconstructions of the vascular anatomy after the previous CABG. The models were sterilized and taken to the operating theatre for orientation during the surgical procedure. CONCLUSIONS Stereolithographic replicas are helpful for choosing treatment strategies in surgical planning and for intraoperative orientation during reoperations of patients with previous CABG.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses the microscale heat transfer problem from heated lattice to the gas. A micro-device for enhanced heat transfer is presented and numerically investigated. Thermal creep induces 3-D vortex structures in the vicinity of the lattice. The gas flow is in the slip flow regime (Knudsen number Kn⩽0.1Kn⩽0.1). The simulations are performed using slip flow Navier–Stokes equations with boundary condition formulations proposed by Maxwell and Smoluchowski. In this study the wire thicknesses and distances of the heated lattice are varied. The surface geometrical properties alter significantly heat flux through the surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For a three-dimensional vertically-oriented fault zone, we consider the coupled effects of fluid flow, heat transfer and reactive mass transport, to investigate the patterns of fluid flow, temperature distribution, mineral alteration and chemically induced porosity changes. We show, analytically and numerically, that finger-like convection patterns can arise in a vertically-oriented fault zone. The onset and patterns of convective fluid flow are controlled by the Rayleigh number which is a function of the thermal properties of the fluid and the rock, the vertical temperature gradient, and the height and the permeability of the fault zone. Vigorous fluid flow causes low temperature gradients over a large region of the fault zone. In such a case, flow across lithological interfaces becomes the most important mechanism for the formation of sharp chemical reaction fronts. The degree of rock buffering, the extent and intensity of alteration, the alteration mineralogy and in some cases the formation of ore deposits are controlled by the magnitude of the flow velocity across these compositional interfaces in the rock. This indicates that alteration patterns along compositional boundaries in the rock may provide some insights into the convection pattern. The advective mass and heat exchanges between the fault zone and the wallrock depend on the permeability contrast between the fault zone and the wallrock. A high permeability contrast promotes focussed convective flow within the fault zone and diffusive exchange of heat and chemical reactants between the fault zone and the wallrock. However, a more gradual permeability change may lead to a regional-scale convective flow system where the flow pattern in the fault affects large-scale fluid flow, mass transport and chemical alteration in the wallrocks

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE For dental implant treatment planning and placement, a precise anatomic description of the nasopalatine canal (NC) is necessary. This descriptive retrospective study evaluated dimensions of the NC and buccal bone plate (BBP) and the tridimensional association of the anatomic variants of NC, using cone-beam computed tomography (CBCT). METHODS This study included 230 CBCTs. Sagittal slices were used for measurements of the NC and BBP and to evaluate shape and direction-course of the NC. Coronal slices were used to assess NC shape and axial slices to assess number of incisive foramina and foramina of Stenson. RESULTS Mean NC length was 12.34 ± 2.79 mm, statistically significant differences were detected between genders (p < 0.001). Mean BBP length was 20.87 ± 3.68 mm, statistically significant differences were found for the dental status (p < 0.001) and mean BBP width was 6.83 ± 1.28 mm, significant differences were detected between genders (p < 0.001). Mean nasopalatine angle was 73.33° ± 8.11°, significant differences were found in sagittal and coronal classifications. The most prevalent canal was: cylindrical sagittal shape (48.2 %); slanted-straight direction-course (57.6 %); Ya-type coronal shape (42.4 %); and one foramen incisive with two Stenson's foramina (1-2) (50.9 %). Sagittal shape was associated with sagittal direction-course (p < 0.001). Coronal shape was associated with axial classification (p < 0.001). CONCLUSIONS The NC anatomy is highly variable. Gender is related to the NC length and BBP width, while dental status is related to BBP length. There was an association between the different sagittal classifications of the NC and between the coronal shape and axial classification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to validate oxygen-sensitive 3He-MRI in noninvasive determination of the regional, two- and three-dimensional distribution of oxygen partial pressure. In a gas-filled elastic silicon ventilation bag used as a lung phantom, oxygen sensitive two- and three-dimensional 3He-MRI measurements were performed at different oxygen concentrations which had been equilibrated in a range of normal and pathologic values. The oxygen partial pressure distribution was determined from 3He-MRI using newly developed software allowing for mapping of oxygen partial pressure. The reference bulk oxygen partial pressure inside the phantom was measured by conventional respiratory gas analysis. In two-dimensional measurements, image-based and gas-analysis results correlated with r=0.98; in three-dimensional measurements the between-methods correlation coefficient was r=0.89. The signal-to-noise ratio of three-dimensional measurements was about half of that of two-dimensional measurements and became critical (below 3) in some data sets. Oxygen-sensitive 3He-MRI allows for noninvasive determination of the two- and three-dimensional distribution of oxygen partial pressure in gas-filled airspaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose In this study, we show the use of three-dimensional printing models for preoperative planning of surgery for patients with complex aortic arch anomalies. Description A 70-year-old man with an extensively arteriosclerotic aneurysm reaching from the ascending aorta to the descending aorta was referred to our center for complete aortic arch replacement. We visualized and reconstructed computed tomography data of the patient and fabricated a flexible three-dimensional model of the aortic arch including the aneurysm. Evaluation This model was very helpful for the preoperative decision making and planning of the frozen elephant trunk procedure owing to the exact and lifelike illustration of the native aortic arch. Conclusions Three-dimensional models are helpful in preoperative planning and postoperative evaluation of frozen elephant trunk procedures in patients with complex aortic anatomy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three-dimensional oxalate-based {[Ru(bpy)3][Cu2xNi2(1-x)(ox)3]}n (0≤ x ≤ 1, ox = C2O42-, bpy = 2,2‘bipyridine) were synthesized. The structure was determined for x = 1 by X-ray diffraction on single crystal. The compound crystallizes in the cubic space group P4132. It shows a three-dimensional 10-gon 3-connected (10,3) anionic network where copper(II) has an unusual tris(bischelated) environment. X-ray powder diffraction patterns and their Rietveld refinement show that all the compounds along the series are isostructural and single-phased. According to X-ray absorption spectroscopy, copper(II) and nickel(II) have an octahedral environment, respectively elongated and trigonally distorted. As shown by natural circular dichroism, the optically active forms of {[Ru(bpy)3][CuxNi2(1-x)(ox)3]}n are obtained starting from resolved Δ- or Λ-[Ru(bpy)3]2+. The Curie−Weiss temperatures range between −55 (x = 1) and −150 K (x = 0). The antiferromagnetic exchange interaction thus decreases when the copper contents increases in agreement with the crystallographic structure of the compounds and the electronic structure of the metal ions. At low temperature, the compounds exhibit complex long-range ordered magnetic behavior.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The numerical simulations of the magnetic properties of extended three-dimensional networks containing M(II) ions with an S = 5/2 ground-state spin have been carried out within the framework of the isotropic Heisenberg model. Analytical expressions fitting the numerical simulations for the primitive cubic, diamond, together with (10−3) cubic networks have all been derived. With these empirical formulas in hands, we can now extract the interaction between the magnetic ions from the experimental data for these networks. In the case of the primitive cubic network, these expressions are directly compared with those from the high-temperature expansions of the partition function. A fit of the experimental data for three complexes, namely [(N(CH3)4][Mn(N3)] 1, [Mn(CN4)]n 2, and [FeII(bipy)3][MnII2(ox)3] 3, has been carried out. The best fits were those obtained using the following parameters, J = −3.5 cm-1, g = 2.01 (1); J = −8.3 cm-1, g = 1.95 (2); and J = −2.0 cm-1, g = 1.95 (3).