77 resultados para IMPLANT-SUPPORTED PROSTHESES


Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE To compare time-efficiency in the production of implant crowns using a digital workflow versus the conventional pathway. MATERIALS AND METHODS This prospective clinical study used a crossover design that included 20 study participants receiving single-tooth replacements in posterior sites. Each patient received a customized titanium abutment plus a computer-aided design/computer-assisted manufacture (CAD/CAM) zirconia suprastructure (for those in the test group, using digital workflow) and a standardized titanium abutment plus a porcelain-fused-to-metal crown (for those in the control group, using a conventional pathway). The start of the implant prosthetic treatment was established as the baseline. Time-efficiency analysis was defined as the primary outcome, and was measured for every single clinical and laboratory work step in minutes. Statistical analysis was calculated with the Wilcoxon rank sum test. RESULTS All crowns could be provided within two clinical appointments, independent of the manufacturing process. The mean total production time, as the sum of clinical plus laboratory work steps, was significantly different. The mean ± standard deviation (SD) time was 185.4 ± 17.9 minutes for the digital workflow process and 223.0 ± 26.2 minutes for the conventional pathway (P = .0001). Therefore, digital processing for overall treatment was 16% faster. Detailed analysis for the clinical treatment revealed a significantly reduced mean ± SD chair time of 27.3 ± 3.4 minutes for the test group compared with 33.2 ± 4.9 minutes for the control group (P = .0001). Similar results were found for the mean laboratory work time, with a significant decrease of 158.1 ± 17.2 minutes for the test group vs 189.8 ± 25.3 minutes for the control group (P = .0001). CONCLUSION Only a few studies have investigated efficiency parameters of digital workflows compared with conventional pathways in implant dental medicine. This investigation shows that the digital workflow seems to be more time-efficient than the established conventional production pathway for fixed implant-supported crowns. Both clinical chair time and laboratory manufacturing steps could be effectively shortened with the digital process of intraoral scanning plus CAD/CAM technology.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVES The aim of this prospective cohort trial was to perform a cost/time analysis for implant-supported single-unit reconstructions in the digital workflow compared to the conventional pathway. MATERIALS AND METHODS A total of 20 patients were included for rehabilitation with 2 × 20 implant crowns in a crossover study design and treated consecutively each with customized titanium abutments plus CAD/CAM-zirconia-suprastructures (test: digital) and with standardized titanium abutments plus PFM-crowns (control conventional). Starting with prosthetic treatment, analysis was estimated for clinical and laboratory work steps including measure of costs in Swiss Francs (CHF), productivity rates and cost minimization for first-line therapy. Statistical calculations were performed with Wilcoxon signed-rank test. RESULTS Both protocols worked successfully for all test and control reconstructions. Direct treatment costs were significantly lower for the digital workflow 1815.35 CHF compared to the conventional pathway 2119.65 CHF [P = 0.0004]. For subprocess evaluation, total laboratory costs were calculated as 941.95 CHF for the test group and 1245.65 CHF for the control group, respectively [P = 0.003]. The clinical dental productivity rate amounted to 29.64 CHF/min (digital) and 24.37 CHF/min (conventional) [P = 0.002]. Overall, cost minimization analysis exhibited an 18% cost reduction within the digital process. CONCLUSION The digital workflow was more efficient than the established conventional pathway for implant-supported crowns in this investigation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Technical complications in implant prosthetic cases represent a major challenge in dentistry. This case report describes minimally invasive management to recover an implant with a fractured remnant of a zirconia abutment, including provisional rehabilitation during a sequential treatment protocol in the esthetic zone. A patient was treated with a screw-retained one-piece implant-supported reconstruction made of a customized zirconia abutment with direct ceramic veneering in the maxillary right central incisor position. During the prosthetic try-in, a fracture in the apical portion of the abutment was evident. The first rescue attempt led to fracture of the retrieval instrument. Immediately, an individualized wired construction was applied to bond the existing fractured reconstruction to the neighboring teeth to maintain the peri-implant mucosal architecture. Because the implant screw canal was blocked, a customized round bur had to be manufactured and was placed in the implant axis with a specific bracket tool from the service set to protect the interior implant threads. Then, the drills of the service set were guided by the newly created access to remove the fractured remnants. The implant screw was retapped and the area rinsed with chlorhexidine solution. All remnants were removed without the need for surgical intervention. Neither the implant connection nor the bone-to-implant interface was damaged. The stepwise treatment approach with the customized round bur combined with the system-specific drills of the service set saved the blocked implant so that the patient could be successfully rehabilitated with a new implant reconstruction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To assess the biological and technical complication rates of single crowns on vital teeth (SC-V), endodontically treated teeth without post and core (SC-E), with a cast post and core (SC-PC) and on implants (SC-I). Material and methods: From 392 patients with chronic periodontitis treated and documented by graduate students during the period from 1978 to 2002, 199 were reexamined during 2005 for this retrospective cohort study, and 64 of these patients were treated with SCs. Statistical analysis included Kaplan–Meier survival functions and event rates per 100 years of object-time. Poisson regression was used to compare the four groups of crowns with respect to the incidence rate ratio of failures, and failures and complications combined over 10 years and the entire observation period. Results: Forty-one (64%) female and 23 (36%) male patients participated in the reexamination. At the time of seating the crowns, the mean patient age was 46.8 (range 24–66.3) years. One hundred and sixty-eight single unit crowns were incorporated. Their mean follow-up time was 11.8 (range 0.8–26.4) years. During the time of observation, 22 biological and 11 technical complications occurred; 19 SC were lost. The chance for SC-V (56) to remain free of any failure or complication was 89.3% (95% confidence interval [CI] 76.1–95.4) after 10 years, 85.8% (95% CI 66–94.5) for SC-E (34), 75.9% for SC-PC (39), (95% CI 58.8–86.7) and 66.2% (95% CI 45.1–80.7) for SC-I (39). Over 10 years, 95% of SC-I remained free of failure and demonstrated a cumulative incidence of failure or complication of 34%. Compared with SC-E, SC-I were 3.5 times more likely to yield failures or complications and SC-PC failed 1.7 times more frequently than did SC-E. SC-V had the lowest rate of failures or complications over the 10 years. Conclusions: While SCs on vital teeth have the best prognosis, those on endodontically treated teeth have a slightly poorer prognosis over 10 years. Crowns on teeth with post and cores and implant-supported SCs displayed the highest incidence of failures and complications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This case report documents the prosthetic rehabilitation of a patient showing the typical features of combination syndrome. This case documentation gives a general overview of the suspected development and the prevalence of this "syndrome". A treatment option should be shown by the example of a patient from the starting situation until the prosthetic therapy by means of a complete maxillary denture and an implant-supported mandibular overdenture rigidly retained with a milled bar.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To assess the 5-year and 10-year survival and complication rates of implant-supported fixed reconstructions in partially and totally edentulous patients with regard to the optimal number and distribution of dental implants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To assess the 5-year survival of implant-supported single crowns (SCs) and to describe the incidence of biological, technical, and aesthetic complications. The focused question was: What is the survival rate of implants supporting single crowns and implant-supported crowns with a mean follow-up of 5 years and to which extent do biological, technical, and aesthetic complications occur?

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The final goal of mandibular reconstruction following ablative surgery for oral cancer is often considered to be dental implant-supported oral rehabilitation, for which bone grafts should ideally be placed in a suitable position taking subsequent prosthetic restoration into account. The aim of this study was to evaluate the efficacy of a standardized treatment strategy for mandibular reconstruction according to the size of the bony defect and planned subsequent dental prosthetic rehabilitation. Data of 56 patients, who had undergone such a systematic mandibular fibula free flap reconstruction, were retrospectively analyzed. Early complications were observed in 41.5% of the patients but only in those who had been irradiated. Late complications were found in 38.2%. Dental implant survival rate was 92%, and dental prosthetic treatment has been completed in all classes of bony defects with an overall success rate of 42.9%. The main reasons for failure of the complete dental reconstruction were patients' poor cooperation (30.4%) and tumour recurrence (14.3%) followed by surgery-related factors (10.8%) such as implant failure and an unfavourable intermaxillary relationship between the maxilla and the mandible. A comparison of our results with the literature findings revealed no marked differences in the complication rates and implant survival rates. However, a systematic concept for the reconstructive treatment like the method presented here, plays an important role in the successful completion of dental reconstruction. The success rate could still be improved by some technical progress in implant and bone graft positioning.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This case series reports on the use of nonsilica-based high-strength full ceramics for different prosthetic indications. Fifty-two consecutive patients received tooth- or implant-supported zirconia reconstructions during a 2-year period. The observation period for reexamination was 12 to 30 months. The most frequent indications were single crowns and short-span fixed partial dentures. A few implant superstructures were screw-retained, whereas all remaining restorations were cemented on natural teeth or zirconia implant abutments. Clinical examination included biologic (probing depths, bleeding on probing) and esthetic (Papilla Index) parameters, as well as technical complications. No implant was lost or caused any problems, but two teeth were lost after horizontal fracture. Overall, the periodontal parameters were favorable. Fractures of frameworks or implant abutments were not observed. Abutment-screw loosening occurred once for one premolar single crown. Furthermore, five implant crowns in the posterior region exhibited chipping of the porcelain veneering material. With regard to esthetics, no reconstructions were considered unacceptable, but three crowns were remade shortly after delivery. In this short-term study, it was observed that biologic, esthetic, and mechanical properties of zirconia were favorable, and the material could be used in various prosthetic indications on teeth or implants.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present paper deals with the double crown technique in removable prosthodontics. New ceramic materials like zirconia are increasingly used in combination with CAD/CAM technologies for framework fabrication of fixed prosthesis, tooth- or implant-supported. However, zirconia is also a newly accepted material in removable prosthodontics. It replaces gold alloys for the fabrication of primary telescopic crowns. The Galvanoforming technology is preferably used to fabricate the secondary crowns. The combination of both techniques and materials results in a prosthetic reconstruction of high quality, optimum fit and good biocompatibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: There is evidence for the superiority of two-implant overdentures over complete dentures in the mandible. Various anchorage devices were used to provide stability to overdentures. The aim of the present study was to compare two designs of a rigid bar connecting two mandibular implants. MATERIALS AND METHODS: Completely edentulous patients received a new denture in the maxilla and an implant-supported overdenture in the mandible. They were randomly allocated to two groups (A or B) with regard to the bar design. A standard U-shaped bar (Dolder bar) was used connecting the two implants in a straight line. For comparison, precision attachments were soldered distal to the bar copings. Group A started the study with the standard bar (S-bar), while group B started with the attachment-bar (A-bar). After 3 months, they had to answer a questionnaire (visual analogue scale [VAS]); then the bar design was changed in both groups. After a period of another 3 months, the patients had to answer the same questions; then they had the choice to keep their preferred bar. Now the study period was extended to another year of observation, and the patients answered again the same questionnaire. In vivo force measurements were carried out with both bar types at the end of the test periods. The prosthetic maintenance service carried out during the 6-month period was recorded for both bar types in both groups. Statistical analysis as performed with the SPSS statistical package (SPSS Inc., Chicago, IL, USA). RESULTS: Satisfaction was high in both groups. Group B, who had entered the study with the attachment bar, gave slightly better ratings to this type for four items, while in group A, no differences were found. At the end of the 6-month comparison period, all but one patient wished to continue to wear the attachment bar. Prosthetic service was equal in groups A and B, but the total number of interventions is significantly higher in the attachment bar. Force patterns of maximum biting were similar in both bar designs, but exhibited significantly higher axial forces in the attachment bar. CONCLUSIONS: Both bar designs provide good retention and functional comfort. High stability appears to be an important factor for the patients' satisfaction and oral comfort. Rigid retention results in a higher force impact and appears to evoke the need for the retightening of occlusal screws, resulting in more maintenance service.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To assess retrospectively the cumulative costs for the long-term oral rehabilitation of patients with birth defects affecting the development of teeth. METHODS: Patients with birth defects who had received fixed reconstructions on teeth and/or implants > or =5 years ago were asked to participate in a comprehensive clinical, radiographic and economic evaluation. RESULTS: From the 45 patients included, 18 were cases with a cleft lip and palate, five had amelogenesis/dentinogenesis imperfecta and 22 were cases with hypodontia/oligodontia. The initial costs for the first oral rehabilitation (before the age of 20) had been covered by the Swiss Insurance for Disability. The costs for the initial rehabilitation of the 45 cases amounted to 407,584 CHF (39% for laboratory fees). Linear regression analyses for the initial treatment costs per replaced tooth revealed the formula 731 CHF+(811 CHF x units) on teeth and 3369 CHF+(1183 CHF x units) for reconstructions on implants (P<.001). Fifty-eight percent of the patients with tooth-supported reconstructions remained free from failures/complications (median observation 15.7 years). Forty-seven percent of the patients with implant-supported reconstructions remained free from failures/complications (median observation 8 years). The long-term cumulative treatment costs for implant cases, however, were not statistically significantly different compared with cases reconstructed with tooth-supported fixed reconstructions. Twenty-seven percent of the initial treatment costs were needed to cover supportive periodontal therapy as well as the treatment of technical/biological complications and failures. CONCLUSION: Insurance companies should accept to cover implant-supported reconstructions because there is no need to prepare healthy teeth, fewer tooth units need to be replaced and the cumulative long-term costs seem to be similar compared with cases restored on teeth.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The therapy of traumatized front teeth with ankylosis and additional root resorption is a real challenge for the clinician. Due to the infraposition ankylosed teeth are useless and esthetically unsatisfactory. The progressive replacement resorption and the vertical growth inhibition render an intervention inevitable. In the following case report, the prophylaxis of the alveolar ridge is brought into focus. The treatment of two ankylosed teeth by decoronation, preservation of the alveolar ridge and an implant-supported supraconstruction will be presented. The additional histological assessment confirms the diagnosis and the choice of treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE The aim of this work was to study the peri-implant soft tissues response, by evaluating both the recession and the papilla indexes, of patients treated with implants with two different configurations. In addition, data were stratified by tooth category, smoking habit and thickness of buccal bone wall. MATERIALS AND METHODS The clinical trial was designed as a prospective, randomized-controlled multicenter study. Adults in need of one or more implants replacing teeth to be removed in the maxilla within the region 15-25 were recruited. Following tooth extraction, the site was randomly allocated to receive either a cylindrical or conical/cylindrical implant. The following parameters were studied: (i) Soft tissue recession (REC) measured by comparing the gingival zenith (GZ) score at baseline (permanent restoration) with that of the yearly follow-up visits over a period of 3 years (V1, V2 and V3). (ii) Interdental Papilla Index (PI): PI measurements were performed at baseline and compared with that of the follow-up visits. In addition, data were stratified by different variables: tooth category: anterior (incisors and canine) and posterior (first and second premolar); smoking habit: patient smoker (habitual or occasional smoker at inclusion) or non-smoker (non-smoker or ex-smoker at inclusion) and thickness of buccal bone wall (TB): TB ≤ 1 mm (thin buccal wall) or TB > 1 mm (thick buccal wall). RESULTS A total of 93 patients were treated with 93 implants. At the surgical re-entry one implant was mobile and then removed; moreover, one patient was lost to follow-up. Ninety-one patients were restored with 91 implant-supported permanent single crowns. After the 3-year follow-up, a mean gain of 0.23 mm of GZ was measured; moreover, 79% and 72% of mesial and distal papillae were classified as >50%/ complete, respectively. From the stratification analysis, not significant differences were found between the mean GZ scores of implants with TB ≤ 1 mm (thin buccal wall) and TB > 1 mm (thick buccal wall), respectively (P < 0.05, Mann-Whitney U-test) at baseline, at V1, V2 and V3 follow-up visits. Also, the other variables did not seem to influence GZ changes over the follow-up period. Moreover, a re-growth of the interproximal mesial and distal papillae was the general trend observed independently from the variables studied. CONCLUSIONS Immediate single implant treatment may be considered a predictable option regarding soft tissue stability over a period of 3 years of follow-up. An overall buccal soft tissue stability was observed during the GZ changes from the baseline to the 3 years of follow-up with a mean GZ reduction of 0.23 mm. A nearly full papillary re-growth can be detectable over a minimum period of 2 years of follow-up for both cylindrical and conical/cylindrical implants. Both the interproximal papilla filling and the midfacial mucosa stability were not influenced by variables such as type of fixture configuration, tooth category, smoke habit, and thickness of buccal bone wall of ≤ 1 mm (thin buccal wall).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES This clinical study measured the dimensional changes of existing lower complete dentures due to the integration of a prefabricated implant bar. Additionally, the impact of this dimensional change on patient satisfaction and oral function was analyzed. METHODS Twenty edentulous patients (10 men/10 women; aged 65.9 ± 11.8 years) received two interforaminal implants. Subsequent to surgery, a chair side adapted, prefabricated bar (SFI Bar(®), C+M, Biel, Switzerland) was inserted, and the matrix was polymerized into the existing lower denture. The change of the denture's lingual dimension was recorded by means of a bicolored, silicone denture duplicate that was sectioned in the oro-vestibular direction in the regions of the symphysis (S) and the implants (I-left, I-right). On the sections, the dimensional increase was measured using a light microscope. Six months after bar insertion, patients answered a standardized questionnaire. RESULTS All dentures exhibited increased lingual volume, more extensively at S than at I (P = 0.001). At S, the median diagonal size of the denture was doubled (+4.33 mm), and at I, the median increase was 50% (I-left/-right = +2.66/+2.62 mm). The original denture size influenced the volume increase (P = 0.024): smaller dentures led to a larger increase. The amount of denture increase did not have negative impact on either self-perceived oral function or patient satisfaction. Approximately, 95% of the patients were satisfied with the treatment results. CONCLUSIONS The lingual size of a lower denture was enlarged by the integration of a prefabricated bar without any negative side effects. Thus, this attachment system is suitable to convert an existing full denture into an implant-supported overdenture.