90 resultados para Heart valve diseases
Resumo:
Polymorphisms in coagulation factors leading to altered susceptibility to cardiovascular diseases have been known for some time and some are now well-established risk factors. More recently, an increasing number of polymorphisms have been identified in platelet receptors and a series of studies indicate that these too may play a role as individual risk factors for stroke and myocardial infarction. The effect of these platelet polymorphisms appears less clear-cut than some of the coagulation factor effects and other, associated, risk factors may be important in defining their role. In this review platelet receptor polymorphisms and their role as risk factors are surveyed and their possible relevance discussed.
Resumo:
A total of 408 cats with various cardiovascular problems has been presented to two investigational clinics during the last 8 years. The number of yearly examinations has steadily increased during this period. Definitive cardiovascular disease was diagnosed in 287 cats, whereby hypertrophic cardiomyopathy (HCM) was the most common diagnosis with 67.6%. Congenital cardiovascular malformations were found in 11.8% of the cases. Ventricular septal defect (VSD) was the most frequent anomaly, in contrast to previously published studies. The ECG was found to be relatively non-specific and insensitive for the diagnosis of heart disease: Its usefulness lies in the recognition and diagnosis of cardiac arrhythmias. The radiographically recognized changes were also non-specific for certain heart diseases. Radiographs of the thorax are especially useful in the evaluation of cardiomegaly, and secondary signs of congestion.
Resumo:
The chest X-ray of a 61-year-old man with severe aortic and mitral stenosis revealed extensive, circularly arranged calcifications in the wall of the left atrial appendage. He died soon after admission to hospital and autopsy confirmed the atrial calcifications in association with severe mitral stenosis. Although such calcification of the left atrial wall is rare, it can be of importance because it may make the usual surgical approach to mitral valve replacement impossible.
Resumo:
Complete correction of Tetralogy of Fallot, the most common cyanotic congenital heart defect, has now become routine. However, late residual lesions, primarily chronic pulmonary valve insufficiency, may have a negative impact on right-ventricular function, leading to the need for reoperation to insert a competent valve at the right-ventricular outflow. The diagnostic modalities pertaining to the failing right ventricle, the timing for eventual reintervention and the various surgical reconstruction possibilities of the right-ventricular outflow tract are still controversial and evolving, and are reviewed with a brief overview on current trends and future outlooks.
Resumo:
Even though depressions and depressive symptoms are frequently observed in patients with medical diseases, their psychological problems are often neither diagnosed nor treated. Diagnosis of mood state might be easy in isolated cases yet it often is not since the precise nature of normal mood cannot be expressed in quantitative terms. Furthermore, depression can only be diagnosed based on the doctor's clinical appraisal and the patient's own description of his/her complaints. There is no gold standard on which depressive symptoms can be based on--and further on, depression is not a diagnosis. Instead, it is a syndrome that calls for differential diagnoses before treatment can be offered. Diagnosing depressive comorbidity in patients with medical complaints is even more difficult because of the overlap between symptoms of depression and accompanying symptoms of the somatic illness e.g. lack of energy. Although depressive states have been known to be a risk factor for the prognosis of patients with coronary heart disease for a long time, there is a paucity of research about the therapy these patients undergo due to the fact that tricyclic anti-depressants can have cardiotoxic effects on patients with heart disease. The treatment of depression in these patients has become a much lower risk since the introduction of serotonin reuptake inhibitors. There is widespread evidence that depressive comorbidity has a negative impact on the prognosis of medical disorders. Despite the complex nature of diagnosing depression, proper diagnosis and treatment is increasingly important in internal medicine and especially cardiology.
Resumo:
Chronic heart failure (CHF) impairs quality of life (QoL) much stronger than other chronic diseases. The objective of this evaluation was to assess the effect of a new integrated comprehensive outpatients rehabilitation program on somatic parameters and quality of life in 51 patients with stable CHF. After rehabilitation, left ventricular ejection fraction, NYHA class, and parameters of sub-maximum and maximum exercise capacity improved significantly between 11 and 20%, and 6-minute walking distance by 58% on average (p < 0.0001). Non-disease specific QoL (Short Form-36 questionnaire) improved in only 2 of 8 subscales (physical functioning [effect size 0.38, p < 0.001], and role functioning [effect size 0.17, p < 0.05]), and a mental component score [effect size 0.47, p < 0.0001]. Disease-specific QoL (Minnesota Living with Heart Failure questionnaire) improved in terms of sum score [effect size 0.24, p < 0.0001], and physical component score [effect size 0.35, p < 0.0001]. Improvement in exercise capacity correlated significantly with improvements in parameters of disease-specific QoL.
Resumo:
Evidence from epidemiological studies indicates that acute exposure to airborne pollutants is associated with an increased risk of morbidity and mortality attributed to cardiovascular diseases. The present study investigated the effects of combustion-derived ultrafine particles (diesel exhaust particles) as well as engineered nanoparticles (titanium dioxide and single-walled carbon nanotubes) on impulse conduction characteristics, myofibrillar structure and the formation of reactive oxygen species in patterned growth strands of neonatal rat ventricular cardiomyocytes in vitro. Diesel exhaust particles as well as titanium dioxide nanoparticles showed the most pronounced effects. We observed a dose-dependent change in heart cell function, an increase in reactive oxygen species and, for titanium dioxide, we also found a less organized myofibrillar structure. The mildest effects were observed for single-walled carbon nanotubes, for which no clear dose-dependent alterations of theta and dV/dt(max) could be determined. In addition, there was no increase in oxidative stress and no change in the myofibrillar structure. These results suggest that diesel exhaust as well as titanium dioxide particles and to a lesser extent also single-walled carbon nanotubes can directly induce cardiac cell damage and can affect the function of the cells.
Resumo:
Autoantibodies play a key role in diagnostic laboratories as markers of autoimmune diseases. In addition to their role as markers they mediate diverse effects in vivo. Autoantibodies with protective effect have been described. Natural protective IgM autoantibodies against tumour-antigens of malignant cells or their precursors may contribute to increased survival rates of carcinoma patients. In a mouse model of systemic lupus erythematosus it has been shown that anti-dsDNA IgM autoantibodies protect from glomerular damage. In contrast, a direct pathogenic role of autoantibodies has been well established e.g. in myasthenia gravis or in Goodpasture syndrome. Similarly autoantibodies against SSA Ro52 are detrimental in neonatal lupus erythematosus with congenital heart block. Moreover, putatively protective autoantibodies may become pathogenic during the course of the disease such as the onconeuronal autoantibodies whose pathogenicity depends on their compartmentalisation. In patients with paraneoplastic syndromes tumour cells express proteins that are also naturally present in the brain. Anti-tumour autoantibodies which temporarily suppress tumour growth can provoke an autoimmune attack on neurons once having crossed the blood-brain barrier and cause specific neurological symptoms. Only a restricted number of autoantibodies are useful follow-up markers for the effectiveness of treatment in autoimmune diseases. Certain autoantibodies hold prognostic value and appear years or even decades before the diagnosis of disease such as the antimitochondrial antibodies in primary biliary cirrhosis or anti-citrullinated protein (CCP)-antibodies in rheumatoid arthritis. It is crucial to know whether the autoantibodies in question recognise linear or conformational epitopes in order to choose the appropriate detection methods. Indirect immunofluorescence microscopy remains a very useful tool for confirmation of results of commercially available immunoassays and for detection of special and rare autoantibodies that otherwise often remain undetected. Standardisation of autoimmune diagnostics is still underway and requires joint efforts by laboratories, clinicians and industry.
Resumo:
We investigated the relative contribution of hemodynamic and clinical factors to serum natriuretic peptide elevation in seventy-one patients with either aortic stenosis or aortic regurgitation. We found that pulmonary hypertension, heart failure and renal failure are the most powerful independent predictors of natriuretic peptide elevation in patients with aortic valve disease, irrespective of the type or severity of valvular lesion itself.
Resumo:
Gene therapy, aimed at the correction of key pathologies being out of reach for conventional drugs, bears the potential to alter the treatment of cardiovascular diseases radically and thereby of heart failure. Heart failure gene therapy refers to a therapeutic system of targeted drug delivery to the heart that uses formulations of DNA and RNA, whose products determine the therapeutic classification through their biological actions. Among resident cardiac cells, cardiomyocytes have been the therapeutic target of numerous attempts to regenerate systolic and diastolic performance, to reverse remodeling and restore electric stability and metabolism. Although the concept to intervene directly within the genetic and molecular foundation of cardiac cells is simple and elegant, the path to clinical reality has been arduous because of the challenge on delivery technologies and vectors, expression regulation, and complex mechanisms of action of therapeutic gene products. Nonetheless, since the first demonstration of in vivo gene transfer into myocardium, there have been a series of advancements that have driven the evolution of heart failure gene therapy from an experimental tool to the threshold of becoming a viable clinical option. The objective of this review is to discuss the current state of the art in the field and point out inevitable innovations on which the future evolution of heart failure gene therapy into an effective and safe clinical treatment relies.
Resumo:
Peri-procedural bleeding complications are feared adverse events in patients undergoing transcatheter aortic valve implantation (TAVI). Little is known about the implications of peri-procedural bleeding on clinical outcome. In a prospective single-center registry of consecutive patients undergoing TAVI, we investigated incidence, predictors and clinical consequences of life-threatening and major bleeding as defined by the Valve Academic Research Consortium. Among 389 consecutive patients undergoing TAVI by a transfemoral (79.2%), transapical (19.6%) or trans-subclavian (1.3%) approach between July 2007 and October 2011, life-threatening or major peri-procedural bleeding events occurred in 64 (16.4%) and 125 patients (32.1%), respectively. Patients with peri-procedural bleeding events had a higher logistic EuroSCORE, more advanced renal disease, and were more symptomatic as assessed by New York Heart Association functional class at baseline as compared to patients with no bleeding. Life-threatening bleeding was associated with a higher all-cause (17.2 vs. 5.6 vs. 3.0%, p < 0.001) and cardiovascular mortality (10.9 vs. 5.6 vs. 2.5%, p = 0.02) at 30 days compared to patients with major bleeding or no bleeding. Multivariate analysis identified transapical access (OR 2.6, 95% CI 1.4-4.8; p = 0.002), glomerular filtration rate <30 ml/min (OR 2.3, 95% CI 1.1-4.7, p = 0.031), and diabetes (OR 1.8, 95% CI 1.001-3.2, p = 0.049) as independent predictors of life-threatening, peri-procedural bleeding. Life-threatening bleeding complications in patients undergoing TAVI are associated with increased mortality. Renal impairment, diabetes, and transapical approach were identified as independent risk factors for life-threatening bleeding events.
Resumo:
AIMS Our aim was to evaluate the invasive haemodynamic indices of high-risk symptomatic patients presenting with 'paradoxical' low-flow, low-gradient, severe aortic stenosis (AS) (PLF-LG) and low-flow, low-gradient severe AS (LEF-LG) and to compare clinical outcomes following transcatheter aortic valve implantation (TAVI) among these challenging AS subgroups. METHODS AND RESULTS Of 534 symptomatic patients undergoing TAVI, 385 had a full pre-procedural right and left heart catheterization. A total of 208 patients had high-gradient severe AS [HGAS; mean gradient (MG) ≥40 mmHg], 85 had PLF-LG [MG ≤ 40 mmHg, indexed aortic valve area [iAVA] ≤0.6 cm(2) m(-2), stroke volume index ≤35 mL/m(2), ejection fraction (EF) ≥50%], and 61 had LEF-LG (MG ≤ 40 mmHg, iAVA ≤0.6 cm(2) m(-2), EF ≤40%). Compared with HGAS, PLF-LG and LEF-LG had higher systemic vascular resistances (HGAS: 1912 ± 654 vs. PLF-LG 2006 ± 586 vs. LEF-LG 2216 ± 765 dyne s m(-5), P = 0.007) but lower valvulo-arterial impedances (HGAS: 7.8 ± 2.7 vs. PLF-LG 6.9 ± 1.9 vs. LEF-LG 7.7 ± 2.5 mmHg mL(-1) m(-2), P = 0.027). At 30 days, no differences in cardiac death (6.5 vs. 4.9 vs. 6.6%, P = 0.90) or death (8.4 vs. 6.1 vs. 6.6%, P = 0.88) were observed among HGAS, PLF-LG, and LEF-LG groups, respectively. At 1 year, New York Heart Association functional improvement occurred in most surviving patients (HGAS: 69.2% vs. PLF-LG 71.7% vs. LEF-LG 89.3%, P = 0.09) and no significant differences in overall mortality were observed (17.6 vs. 20.5 vs. 24.5%, P = 0.67). Compared with HGAS, LEF-LG had a higher 1 year cardiac mortality (adjusted hazard ratio 2.45, 95% confidence interval 1.04-5.75, P = 0.04). CONCLUSION TAVI in PLF-LG or LEF-LG patients is associated with overall mortality rates comparable with HGAS patients and all groups profit symptomatically to a similar extent.
Resumo:
Transcatheter aortic valve implantation (TAVI) is a disruptive technology as it satisfies a previously unmet need which is associated with a profound therapeutic benefit. In randomized clinical trials, TAVI has been shown to improve survival compared with medical treatment among patients considered not suitable candidates for surgical aortic valve replacement (SAVR), and to provide similar outcomes as SAVR in selected high-risk patients. Currently, TAVI is limited to selected elderly patients with symptomatic severe aortic stenosis. As this patient population frequently suffers from comorbid conditions, which may influence outcomes, the selection of patients to undergo TAVI underlies a complex decision process. Several clinical risk score algorithms are routinely used, although they fall short to fully appreciate the true risk among patients currently referred for TAVI. Beyond traditional risk scores, the clinical assessment by an interdisciplinary Heart Team as well as detailed imaging of the aortic valve, aortic root, descending and abdominal aorta as well as peripheral vasculature are important prerequisites to plan a successful procedure. This review will familiarize the reader with the concepts of the interdisciplinary Heart team, risk scores as well as the most important imaging algorithms suited to select appropriate TAVI patients.
Resumo:
Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.