77 resultados para General - statistics and numerical data
Resumo:
Cognitive-perceptive 'basic symptoms' are used complementary to ultra-high-risk criteria in order to predict onset of psychosis in the pre-psychotic phase. The aim was to investigate the prevalence of a broad selection of 'basic symptoms' in a representative general adolescent population sample (GPS; N=96) and to compare it with adolescents first admitted for early onset psychosis (EOP; N=87) or non-psychotic psychiatric disorders (NP; N=137).
Resumo:
OBJECTIVE To investigate whether it is valid to combine follow-up and change data when conducting meta-analyses of continuous outcomes. STUDY DESIGN AND SETTING Meta-epidemiological study of randomized controlled trials in patients with osteoarthritis of the knee/hip, which assessed patient-reported pain. We calculated standardized mean differences (SMDs) based on follow-up and change data, and pooled within-trial differences in SMDs. We also derived pooled SMDs indicating the largest treatment effect within a trial (optimistic selection of SMDs) and derived pooled SMDs from the estimate indicating the smallest treatment effect within a trial (pessimistic selection of SMDs). RESULTS A total of 21 meta-analyses with 189 trials with 292 randomized comparisons in 41,256 patients were included. On average, SMDs were 0.04 standard deviation units more beneficial when follow-up values were used (difference in SMDs: -0.04; 95% confidence interval: -0.13, 0.06; P=0.44). In 13 meta-analyses (62%), there was a relevant difference in clinical and/or significance level between optimistic and pessimistic pooled SMDs. CONCLUSION On average, there is no relevant difference between follow-up and change data SMDs, and combining these estimates in meta-analysis is generally valid. Decision on which type of data to use when both follow-up and change data are available should be prespecified in the meta-analysis protocol.
Resumo:
When observers are presented with two visual targets appearing in the same position in close temporal proximity, a marked reduction in detection performance of the second target has often been reported, the so-called attentional blink phenomenon. Several studies found a similar decrement of P300 amplitudes during the attentional blink period as observed with detection performances of the second target. However, whether the parallel courses of second target performances and corresponding P300 amplitudes resulted from the same underlying mechanisms remained unclear. The aim of our study was therefore to investigate whether the mechanisms underlying the AB can be assessed by fixed-links modeling and whether this kind of assessment would reveal the same or at least related processes in the behavioral and electrophysiological data. On both levels of observation three highly similar processes could be identified: an increasing, a decreasing and a u-shaped trend. Corresponding processes from the behavioral and electrophysiological data were substantially correlated, with the two u-shaped trends showing the strongest association with each other. Our results provide evidence for the assumption that the same mechanisms underlie attentional blink task performance at the electrophysiological and behavioral levels as assessed by fixed-links models.
Resumo:
An ever increasing number of low Earth orbiting (LEO) satellites is, or will be, equipped with retro-reflectors for Satellite Laser Ranging (SLR) and on-board receivers to collect observations from Global Navigation Satellite Systems (GNSS) such as the Global Positioning Sys- tem (GPS) and the Russian GLONASS and the European Galileo systems in the future. At the Astronomical Insti- tute of the University of Bern (AIUB) LEO precise or- bit determination (POD) using either GPS or SLR data is performed for a wide range of applications for satellites at different altitudes. For this purpose the classical numeri- cal integration techniques, as also used for dynamic orbit determination of satellites at high altitudes, are extended by pseudo-stochastic orbit modeling techniques to effi- ciently cope with potential force model deficiencies for satellites at low altitudes. Accuracies of better than 2 cm may be achieved by pseudo-stochastic orbit modeling for satellites at very low altitudes such as for the GPS-based POD of the Gravity field and steady-state Ocean Circula- tion Explorer (GOCE).
Resumo:
The diffusion of radionuclides is an important safety aspect for nuclear waste disposal in argillaceous host rocks. A long-term diffusion experiment, termed DI-A, is being carried out at the Mont Terri Rock Laboratory in the Opalinus Clay formation. The aim of this experiment is the understanding of the migration and sorption behaviour of cationic and anionic species in consolidated clays. This study reports on the experimental layout and the first results obtained from the DI-A experiment, which include the investigation of HTO, Na-22(+), Cs+, and I- migration during a period of 1 year by analysing these tracers in the water circulating in the borehole. In addition, results obtained from through-diffusion experiments on small-sized samples with HTO, I-, and Cl-36(-) are presented. The decrease of tracer concentrations in the borehole is fastest for Cs+, followed by Na-22(+), HTO, and finally I-. The chemical composition of the artificial pore water in the borehole shows very little variation with time, thus indicating almost no chemical disturbance around the borehole. Through-diffusion experiments in the laboratory that were performed parallel to the bedding plane with two different methods yielded effective diffusion coefficients for HTO of 4-5 X 10(-11) m(2) s(-1) and significantly lower ones for anions Cl- and I- (0.7-1.6 X 10(-11) m(2) s(-1)). The results indicate the importance of anion exclusion effects arising from the negatively charged clay surfaces. Furthermore, they demonstrate the anisotropic diffusion properties of the clay formation with significantly increased diffusion rates parallel to bedding relative to the perpendicular direction. The tracer data of the in situ experiment were successfully described with 2D diffusion models using diffusion and sorption parameters obtained from the above mentioned and other laboratory studies. The modelling results indicate that HTO and I- diffused with no retardation. The retardation of Na+ and Cs+ could be described by empirical sorption expressions from previously derived batch sorption (Cs+) or diffusion (Na+) experiments. Overall, the obtained results demonstrate the feasibility of the technical concept to study the diffusion of nonsorbing and sorbing tracers in consolidated clays. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Background:Erythropoiesis-stimulating agents (ESAs) reduce the need for red blood cell transfusions; however, they increase the risk of thromboembolic events and mortality. The impact of ESAs on quality of life (QoL) is controversial and led to different recommendations of medical societies and authorities in the USA and Europe. We aimed to critically evaluate and quantify the effects of ESAs on QoL in cancer patients.Methods:We included data from randomised controlled trials (RCTs) on the effects of ESAs on QoL in cancer patients. Randomised controlled trials were identified by searching electronic data bases and other sources up to January 2011. To reduce publication and outcome reporting biases, we included unreported results from clinical study reports. We conducted meta-analyses on fatigue- and anaemia-related symptoms measured with the Functional Assessment of Cancer Therapy-Fatigue (FACT-F) and FACT-Anaemia (FACT-An) subscales (primary outcomes) or other validated instruments.Results:We identified 58 eligible RCTs. Clinical study reports were available for 27% (4 out of 15) of the investigator-initiated trials and 95% (41 out of 43) of the industry-initiated trials. We excluded 21 RTCs as we could not use their QoL data for meta-analyses, either because of incomplete reporting (17 RCTs) or because of premature closure of the trial (4 RCTs). We included 37 RCTs with 10 581 patients; 21 RCTs were placebo controlled. Chemotherapy was given in 27 of the 37 RCTs. The median baseline haemoglobin (Hb) level was 10.1 g dl(-1); in 8 studies ESAs were stopped at Hb levels below 13 g dl(-1) and in 27 above 13 g dl(-1). For FACT-F, the mean difference (MD) was 2.41 (95% confidence interval (95% CI) 1.39-3.43; P<0.0001; 23 studies, n=6108) in all cancer patients and 2.81 (95% CI 1.73-3.90; P<0.0001; 19 RCTs, n=4697) in patients receiving chemotherapy, which was below the threshold (⩾3) for a clinically important difference (CID). Erythropoiesis-stimulating agents had a positive effect on anaemia-related symptoms (MD 4.09; 95% CI 2.37-5.80; P=0.001; 14 studies, n=2765) in all cancer patients and 4.50 (95% CI 2.55-6.45; P<0.0001; 11 RCTs, n=2436) in patients receiving chemotherapy, which was above the threshold (⩾4) for a CID. Of note, this effect persisted when we restricted the analysis to placebo-controlled RCTs in patients receiving chemotherapy. There was some evidence that the MDs for FACT-F were above the threshold for a CID in RCTs including cancer patients receiving chemotherapy with Hb levels below 12 g dl(-1) at baseline and in RCTs stopping ESAs at Hb levels above 13 g dl(-1). However, these findings for FACT-F were not confirmed when we restricted the analysis to placebo-controlled RCTs in patients receiving chemotherapy.Conclusions:In cancer patients, particularly those receiving chemotherapy, we found that ESAs provide a small but clinically important improvement in anaemia-related symptoms (FACT-An). For fatigue-related symptoms (FACT-F), the overall effect did not reach the threshold for a CID.British Journal of Cancer advance online publication, 17 April 2014; doi:10.1038/bjc.2014.171 www.bjcancer.com.
Resumo:
Preliminary archaeological and palynological results are presented from an early Byzantine cistern of the village Horvat Kur in eastern Lower Galilee/Israel. The rural site was settled from the Hellenistic until the Early Arab period, its synagogue was constructed shortly after 425 AD and renovated sometimes during the 2nd half of the 6th century AD. It was abandoned probably as a consequence of the earthquake of 749 AD. The intact and properly sealed cistern contained complete or fully restorable pottery. Two cooking pots from the early 5th century AD comprised sediments which was sampled for palynological purposes. Both samples, as well as a sample from the soil beneath one of the pots and a modern surface sample from the site, revealed well preserved palynomorphs in comparably high concentration showing a great potential of the cistern as a pollen archive. The pollen content points to an open, grassy semiarid landscape with an apparent scarcity of cultivars and trees in the vicinity of the site and an abundance of herbs, especially Asteraceae, which are still commonly found in modern regional vegetation.
Resumo:
Resting-state functional connectivity (FC) fMRI (rs-fcMRI) offers an appealing approach to mapping the brain's intrinsic functional organization. Blood oxygen level dependent (BOLD) and arterial spin labeling (ASL) are the two main rs-fcMRI approaches to assess alterations in brain networks associated with individual differences, behavior and psychopathology. While the BOLD signal is stronger with a higher temporal resolution, ASL provides quantitative, direct measures of the physiology and metabolism of specific networks. This study systematically investigated the similarity and reliability of resting brain networks (RBNs) in BOLD and ASL. A 2×2×2 factorial design was employed where each subject underwent repeated BOLD and ASL rs-fcMRI scans on two occasions on two MRI scanners respectively. Both independent and joint FC analyses revealed common RBNs in ASL and BOLD rs-fcMRI with a moderate to high level of spatial overlap, verified by Dice Similarity Coefficients. Test-retest analyses indicated more reliable spatial network patterns in BOLD (average modal Intraclass Correlation Coefficients: 0.905±0.033 between-sessions; 0.885±0.052 between-scanners) than ASL (0.545±0.048; 0.575±0.059). Nevertheless, ASL provided highly reproducible (0.955±0.021; 0.970±0.011) network-specific CBF measurements. Moreover, we observed positive correlations between regional CBF and FC in core areas of all RBNs indicating a relationship between network connectivity and its baseline metabolism. Taken together, the combination of ASL and BOLD rs-fcMRI provides a powerful tool for characterizing the spatiotemporal and quantitative properties of RBNs. These findings pave the way for future BOLD and ASL rs-fcMRI studies in clinical populations that are carried out across time and scanners.