60 resultados para Frame-of-reference
Resumo:
Purpose This paper furthers the analysis of patterns regulating capitalist accumulation based on a historical anthropology of economic activities revolving around and within the Mauritian Export Processing Zone (EPZ). Design/methodology/approach This paper uses fieldwork in Mauritius to interrogate and critique two important concepts in contemporary social theory – “embeddedness” and “the informal economy.” These are viewed in the wider frame of social anthropology’s engagement with (neoliberal) capitalism. Findings A process-oriented revision of Polanyi’s work on embeddedness and the “double movement” is proposed to help us situate EPZs within ongoing power struggles found throughout the history of capitalism. This helps us to challenge the notion of economic informality as supplied by Hart and others. Social implications Scholars and policymakers have tended to see economic informality as a force from below, able to disrupt the legal-rational nature of capitalism as practiced from on high. Similarly, there is a view that a precapitalist embeddedness, a “human economy,” has many good things to offer. However, this paper shows that the practices of the state and multinational capitalism, in EPZs and elsewhere, exactly match the practices that are envisioned as the cure to the pitfalls of capitalism. Value of the paper Setting aside the formal-informal distinction in favor of a process-oriented analysis of embeddedness allows us better to understand the shifting struggles among the state, capital, and labor.
Resumo:
The University of Bern has set up the new Laboratory for the Analysis of Radiocarbon with AMS (LARA) equipped with an accelerator mass spectrometer (AMS) MICADAS (MIni CArbon Dating System) to continue its long history of 14C analysis based on conventional counting. The new laboratory is designated to provide routine 14C dating for archaeology, climate research, and other disciplines at the University of Bern and to develop new analytical systems coupled to the gas ion source for 14C analysis of specific compounds or compound classes with specific physical properties. Measurements of reference standards and wood samples dated by dendrochronology demonstrate the quality of the 14C analyses performed at the new laboratory.
Resumo:
PURPOSE Blood loss and blood substitution are associated with higher morbidity after major abdominal surgery. During major liver resection, low local venous pressure, has been shown to reduce blood loss. Ambiguity persists concerning the impact of local venous pressure on blood loss during open radical cystectomy. We aimed to determine the association between intraoperative blood loss and pelvic venous pressure (PVP) and determine factors affecting PVP. MATERIAL AND METHODS In the frame of a single-center, double-blind, randomized trial, PVP was measured in 82 patients from a norepinephrine/low-volume group and in 81 from a control group with liberal hydration. For this secondary analysis, patients from each arm were stratified into subgroups with PVP <5 mmHg or ≥5 mmHg measured after cystectomy (optimal cut-off value for discrimination of patients with relevant blood loss according to the Youden's index). RESULTS Median blood loss was 800 ml [range: 300-1600] in 55/163 patients (34%) with PVP <5 mmHg and 1200 ml [400-3000] in 108/163 patients (66%) with PVP ≥5 mmHg; (P<0.0001). A PVP <5 mmHg was measured in 42/82 patients (51%) in the norepinephrine/low-volume group and 13/81 (16%) in the control group (P<0.0001). PVP dropped significantly after removal of abdominal packing and abdominal lifting in both groups at all time points (at begin and end of pelvic lymph node dissection, end of cystectomy) (P<0.0001). No correlation between PVP and central venous pressure could be detected. CONCLUSIONS Blood loss was significantly reduced in patients with low PVP. Factors affecting PVP were fluid management and abdominal packing.
Resumo:
Aims To explore the impact of the functional severity of coronary artery stenosis on changes in myocardial oxygenation during pharmacological vasodilation, using oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR) imaging and invasive fractional flow reserve (FFR). An FFR is considered a standard of reference for assessing haemodynamic relevance of coronary artery stenosis; yet, the relationship of FFR to changes in myocardial oxygenation during vasodilator stress and thus to an objective marker for ischaemia on the tissue level is not well understood. Methods and results We prospectively recruited 64 patients with suspected/known coronary artery disease undergoing invasive angiography. The FFR was performed in intermediate coronary artery stenosis. OS-CMR images were acquired using a T2*-sensitive sequence before and after adenosine-induced vasodilation, with myocardial segments matched to angiography. Very strict image quality criteria were defined to ensure the validity of results. The FFR was performed in 37 patients. Because of the strict image quality criteria, 41% of segments had to be excluded, leaving 29/64 patients for the blinded OS-CMR analysis. Coronary territories with an associated FFR of <0.80 showed a lack of increase in myocardial oxygenation [mean signal intensity (ΔSI) −0.49%; 95% confidence interval (CI) −3.78 to 2.78 vs. +7.30%; 95% CI 4.08 to 10.64; P < 0.001]. An FFR of <0.54 best predicted a complete lack of a vasodilator-induced oxygenation increase (sensitivity 71% and specificity 75%). An OS-CMR ΔSI <4.78% identified an FFR of <0.8 with a sensitivity of 86% and specificity of 92%. Conclusion An FFR of <0.80 is associated with a lack of an adenosine-inducible increase in oxygenation of the dependent coronary territory, while a complete lack of such an increase was best predicted by an FFR of <0.54. Further studies are warranted to identify clinically meaningful cut-off values for FFR measurements and to assess the utility of OS-CMR as an alternative clinical tool for assessing the functional relevance of coronary artery stenosis.
Resumo:
Previous research agrees that approach goals have positive effects whereas avoidance goals have negative effects on performance. By contrast, the present chapter looks at the conditions under which even avoidance goals may have positive effects on performance. We will first review the previous research that supports the positive consequences of avoidance goals. Then we will argue that the positive and negative consequences of approach and avoidance goals on performance depend on an individual‘s neuroticism level and the time frame of their goal striving. Because neuroticism is positively related to avoidance goals, we assume that individuals with high levels of neuroticism may derive some benefits from avoidance goals. We have specified this assumption by hypothesizing that the fit between an individual‘s level of neuroticism and their avoidance goals leads to favorable consequences in the short term – but to negative outcomes in the long run. A short-term, experimental study with employees and a long-term correlative field study with undergraduate students were conducted to test whether neuroticism moderates the short- and long-term effects of avoidance versus approach goals on performance. Experimental study 1 showed that individuals with a high level of neuroticism performed best in the short term when they were assigned to avoidance goals, whereas individuals with a low level of neuroticism performed best when pursuing approach goals. However, study 2 indicated that in the long run individuals with a high level of neuroticism performed worse when striving for avoidance goals, whereas individuals with a low level of neuroticism were not impaired at all by avoidance goals. In summary, the pattern of results supports the hypothesis that a fit between a high level of neuroticism and avoidance goals has positive consequences in the short term, but leads to negative outcomes in the long run. We strongly encourage further research to investigate short- and long-term effects of approach and avoidance goals on performance in conjunction with an individual‘s personality, which may moderate these effects.
Resumo:
Complete transcriptomic data at high resolution are available only for a few model organisms with medical importance. The gene structures of non-model organisms are mostly computationally predicted based on comparative genomics with other species. As a result, more than half of the horse gene models are known only by projection. Experimental data supporting these gene models are scarce. Moreover, most of the annotated equine genes are single-transcript genes. Utilizing RNA sequencing (RNA-seq) the experimental validation of predicted transcriptomes has become accessible at reasonable costs. To improve the horse genome annotation we performed RNA-seq on 561 samples of peripheral blood mononuclear cells (PBMCs) derived from 85 Warmblood horses. The mapped sequencing reads were used to build a new transcriptome assembly. The new assembly revealed many alternative isoforms associated to known genes or to those predicted by the Ensembl and/or Gnomon pipelines. We also identified 7,531 transcripts not associated with any horse gene annotated in public databases. Of these, 3,280 transcripts did not have a homologous match to any sequence deposited in the NCBI EST database suggesting horse specificity. The unknown transcripts were categorized as coding and noncoding based on predicted coding potential scores. Among them 230 transcripts had high coding potential score, at least 2 exons, and an open reading frame of at least 300 nt. We experimentally validated 9 new equine coding transcripts using RT-PCR and Sanger sequencing. Our results provide valuable detailed information on many transcripts yet to be annotated in the horse genome.
Resumo:
The integrated elliptic flow of charged particles produced in Pb+Pb collisions at √sNN = 2.76 TeV has been measured with the ATLAS detector using data collected at the Large Hadron Collider. The anisotropy parameter, v2, was measured in the pseudorapidity range |η| ≤ 2.5 with the event-plane method. In order to include tracks with very low transverse momentum pT, thus reducing the uncertainty in v2 integrated over pT, a 1 μb−1 data sample recorded without a magnetic field in the tracking detectors is used. The centrality dependence of the integrated v2 is compared to other measurements obtained with higher pT thresholds. The integrated elliptic flow is weakly decreasing with |η|. The integrated v2 transformed to the rest frame of one of the colliding nuclei is compared to the lower-energy RHIC data.
Resumo:
This paper addresses two major topics concerning the role of expectations in the formation of reference points. First, we show that when expectations are present, they have a significant impact on reference point formation. Second, we find that decision-makers employ expected values when forming reference points (integrated mechanism) as opposed to single possible outcomes (segregated mechanism). Despite the importance of reference points in prospect theory, to date, there is no standard method of examining these. We develop a new experimental design that employs an indirect approach and extends an existing direct approach. Our findings are consistent across the two approaches.
Resumo:
The use of fluorescence is a valuable and increasingly accessible means of probing the pharmacology and physiology of cells and their receptors. To date, the use of fluorescence-based methods for 5-HT3 receptor research has been quite limited and, although a variety of approaches have been described, these are broadly distributed throughout the literature. In this review we condense these findings into a single, accessible source of reference with the hope of promoting the use of these valuable molecular probes.
Resumo:
The important task to observe the global coverage of middle atmospheric trace gases like water vapor or ozone usually is accomplished by satellites. Climate and atmospheric studies rely upon the knowledge of trace gas distributions throughout the stratosphere and mesosphere. Many of these gases are currently measured from satellites, but it is not clear whether this capability will be maintained in the future. This could lead to a significant knowledge gap of the state of the atmosphere. We explore the possibilities of mapping middle atmospheric water vapor in the Northern Hemisphere by using Lagrangian trajectory calculations and water vapor profile data from a small network of five ground-based microwave radiometers. Four of them are operated within the frame of NDACC (Network for the Detection of Atmospheric Composition Change). Keeping in mind that the instruments are based on different hardware and calibration setups, a height-dependent bias of the retrieved water vapor profiles has to be expected among the microwave radiometers. In order to correct and harmonize the different data sets, the Microwave Limb Sounder (MLS) on the Aura satellite is used to serve as a kind of traveling standard. A domain-averaging TM (trajectory mapping) method is applied which simplifies the subsequent validation of the quality of the trajectory-mapped water vapor distribution towards direct satellite observations. Trajectories are calculated forwards and backwards in time for up to 10 days using 6 hourly meteorological wind analysis fields. Overall, a total of four case studies of trajectory mapping in different meteorological regimes are discussed. One of the case studies takes place during a major sudden stratospheric warming (SSW) accompanied by the polar vortex breakdown; a second takes place after the reformation of stable circulation system. TM cases close to the fall equinox and June solstice event from the year 2012 complete the study, showing the high potential of a network of ground-based remote sensing instruments to synthesize hemispheric maps of water vapor.
Resumo:
AMS-14C applications often require the analysis of small samples. Such is the case of atmospheric aerosols where frequently only a small amount of sample is available. The ion beam physics group at the ETH, Zurich, has designed an Automated Graphitization Equipment (AGE III) for routine graphite production for AMS analysis from organic samples of approximately 1 mg. In this study, we explore the potential use of the AGE III for graphitization of particulate carbon collected in quartz filters. In order to test the methodology, samples of reference materials and blanks with different sizes were prepared in the AGE III and the graphite was analyzed in a MICADAS AMS (ETH) system. The graphite samples prepared in the AGE III showed recovery yields higher than 80% and reproducible 14C values for masses ranging from 50 to 300 lg. Also, reproducible radiocarbon values were obtained for aerosol filters of small sizes that had been graphitized in the AGE III. As a study case, the tested methodology was applied to PM10 samples collected in two urban cities in Mexico in order to compare the source apportionment of biomass and fossil fuel combustion. The obtained 14C data showed that carbonaceous aerosols from Mexico City have much lower biogenic signature than the smaller city of Cuernavaca.
Resumo:
The important task to observe the global coverage of middle atmospheric trace gases like water vapor or ozone usually is accomplished by satellites. Climate and atmospheric studies rely upon the knowledge of trace gas distributions throughout the stratosphere and mesosphere. Many of these gases are currently measured from satellites, but it is not clear whether this capability will be maintained in the future. This could lead to a significant knowledge gap of the state of the atmosphere. We explore the possibilities of mapping middle atmospheric water vapor in the Northern Hemisphere by using Lagrangian trajectory calculations and water vapor profile data from a small network of five ground-based microwave radiometers. Four of them are operated within the frame of NDACC (Network for the Detection of Atmospheric Composition Change). Keeping in mind that the instruments are based on different hardware and calibration setups, a height-dependent bias of the retrieved water vapor profiles has to be expected among the microwave radiometers. In order to correct and harmonize the different data sets, the Microwave Limb Sounder (MLS) on the Aura satellite is used to serve as a kind of traveling standard. A domain-averaging TM (trajectory mapping) method is applied which simplifies the subsequent validation of the quality of the trajectory-mapped water vapor distribution towards direct satellite observations. Trajectories are calculated forwards and backwards in time for up to 10 days using 6 hourly meteorological wind analysis fields. Overall, a total of four case studies of trajectory mapping in different meteorological regimes are discussed. One of the case studies takes place during a major sudden stratospheric warming (SSW) accompanied by the polar vortex breakdown; a second takes place after the reformation of stable circulation system. TM cases close to the fall equinox and June solstice event from the year 2012 complete the study, showing the high potential of a network of ground-based remote sensing instruments to synthesize hemispheric maps of water vapor.
Resumo:
Homogeneously reprocessed combined GPS/GLONASS 1- and 3-day solutions from 1994 to 2013, generated by the Center for Orbit Determination in Europe (CODE) in the frame of the second reprocessing campaign REPRO-2 of the International GNSS Service, as well as GPS- and GLONASS-only 1- and 3-day solutions for the years 2009 to 2011 are analyzed to assess the impact of the arc length on the estimated Earth Orientation Parameters (EOP, namely polar motion and length of day), on the geocenter, and on the orbits. The conventional CODE 3-day solutions assume continuity of orbits, polar motion components, and of other parameters at the day boundaries. An experimental 3-day solution, which assumes continuity of the orbits, but independence from day to day for all other parameters, as well as a non-overlapping 3-day solution, is included into our analysis. The time series of EOPs, geocenter coordinates, and orbit misclosures, are analyzed. The long-arc solutions were found to be superior to the 1-day solutions: the RMS values of EOP and geocenter series are typically reduced between 10 and 40 %, except for the polar motion rates, where RMS reductions by factors of 2–3 with respect to the 1-day solutions are achieved for the overlapping and the non-overlapping 3-day solutions. In the low-frequency part of the spectrum, the reduction is even more important. The better performance of the orbits of 3-day solutions with respect to 1-day solutions is also confirmed by the validation with satellite laser ranging.
Resumo:
Background: The demand for international harmonization in medical education increases with the growing mobility of students and health professionals. Many medical societies and governmental offices have issued outcome frameworks (OF), which describe aims and contents of medical education based on competencies. These national standards affect the development of curricula as well as assessment and licensing procedures. Comparing OF and identifying factors that limit their comparability may thus foster international harmonization of medical education. Summary of Work: We conducted a systematic search for national OF in MedLine, EmBase and the internet. We included all OF in German or English that resulted from a national consensus process and were published or endorsed by a national society or governmental body. We extracted information in five predetermined categories: history of origin, audience, formal structure, medical schooling system and key terms. Summary of Results: Out of 1816 results, 13 OF were included into further analyses. OF reference each other, often without addressing existing differences (e.g. in target audiences). The two most cited OF are “CanMEDs” and “Scottish Doctor”. OF differ especially in their level of detail as well as in the underlying educational system. Discussion and Conclusions: Based on our results we propose a two-step blueprint for OF, that may help to establish comparability for internationally aligned key features – so-called “core competencies” – while at the same time allowing for necessary regional adaptations in terms of “secondary competencies”. Take-home messages: Considerable differences in at least five categories of OF currently hinder the comparability of outcome frameworks.
Resumo:
A human interleukin 4 (hIL-4)-encoding cDNA (hIL4) probe was used to screen a bovine genomic library, and three clones containing sequences with homology to the human and mouse IL4 cDNAs were isolated. Sequence information obtained from one of these genomic clones was used to design an oligodeoxyribonucleotide primer corresponding to the transcription start point region for use in the polymerase chain reaction (PCR). The PCR-RACE protocol, designed for the rapid amplification of cDNA ends, was successfully used to generate a full-length bovine IL4 (bIL4) cDNA clone from polyadenylated RNA isolated from concanavalin A-stimulated bovine lymph node cells. The bIL4 cDNA is 570 bp in length and contains an open reading frame of 405 nucleotides (nt), coding for a 15.1-kDa precursor of 135 amino acids (aa), which should be reduced to 12.6 kDa for unglycosylated bIL4 after cleavage of a putative hydrophobic leader sequence of 24 aa. The aa sequence contains one possible Asn-linked glycosylation site. Bovine IL4 is shorter than mouse (mIL4) and hIL4, because of a 51-nt deletion in the coding region. Comparison of the overall nt and deduced aa sequences shows a greater homology of bIL4 with hIL4 than with mIL4. This homology is not evenly distributed, however, with the nt sequences 5' and 3' of the coding region showing a much greater homology between all three species than the coding sequence.