52 resultados para Dose reduction


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AIMS Stem cells participate in vascular regeneration following critical ischemia. However, their angiogenic and remodeling properties, as well as their role in ischemia-related endothelial leukocyte activation, need to be further elucidated. Herein, we investigated the effect of bone marrow-derived mesenchymal stromal cells (BM-MSCs) in a critically ischemic murine skin flap model. METHODS Groups received either 1 × 10(5), 5 × 10(5), or 1 × 10(6) BM-MSCs or cell-free conditioned medium (CM). Controls received sodium chloride. Intravital fluorescence microscopy was performed for morphological and quantitative assessment of micro-hemodynamic parameters over 12 days. RESULTS Tortuosity and diameter of conduit-arterioles were pronounced in the MSC groups (P < 0.01), whereas vasodilation was shifted to the end arteriolar level in the CM group (P < 0.01). These effects were accompanied by angiopoietin-2 expression. Functional capillary density and red blood cell velocity were enhanced in all treatment groups (P < 0.01). Although a significant reduction of rolling and sticking leukocytes was observed in the MSC groups with a reduction of diameter in postcapillary venules (P < 0.01), animals receiving CM exhibited a leukocyte-endothelium interaction similar to controls. This correlated with leukocyte common antigen expression in tissue sections (P < 0.01) and p38 mitogen-activated protein kinase expression from tissue samples. Cytokine analysis from BM-MSC culture medium revealed a 50% reduction of pro-inflammatory cytokines (interleukin [IL]-1β, IL-6, IL-12, tumor necrosis factor-α, interferon-γ) and chemokines (keratinocyte chemoattractant, granulocyte colony-stimulating factor) under hypoxic conditions. DISCUSSION We demonstrated positive effects of BM-MSCs on vascular regeneration and modulation of endothelial leukocyte adhesion in critical ischemic skin. The improvements after MSC application were dose-dependent and superior to the use of CM alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES In this phantom CT study, we investigated whether images reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) with reduced tube voltage and current have equivalent quality. We evaluated the effects of different acquisition and reconstruction parameter settings on image quality and radiation doses. Additionally, patient CT studies were evaluated to confirm our phantom results. METHODS Helical and axial 256 multi-slice computed tomography scans of the phantom (Catphan(®)) were performed with varying tube voltages (80-140kV) and currents (30-200mAs). 198 phantom data sets were reconstructed applying FBP and IR with increasing iterations, and soft and sharp kernels. Further, 25 chest and abdomen CT scans, performed with high and low exposure per patient, were reconstructed with IR and FBP. Two independent observers evaluated image quality and radiation doses of both phantom and patient scans. RESULTS In phantom scans, noise reduction was significantly improved using IR with increasing iterations, independent from tissue, scan-mode, tube-voltage, current, and kernel. IR did not affect high-contrast resolution. Low-contrast resolution was also not negatively affected, but improved in scans with doses <5mGy, although object detectability generally decreased with the lowering of exposure. At comparable image quality levels, CTDIvol was reduced by 26-50% using IR. In patients, applying IR vs. FBP resulted in good to excellent image quality, while tube voltage and current settings could be significantly decreased. CONCLUSIONS Our phantom experiments demonstrate that image quality levels of FBP reconstructions can also be achieved at lower tube voltages and tube currents when applying IR. Our findings could be confirmed in patients revealing the potential of IR to significantly reduce CT radiation doses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Deep molecular response (MR(4.5)) defines a subgroup of patients with chronic myeloid leukemia (CML) who may stay in unmaintained remission after treatment discontinuation. It is unclear how many patients achieve MR(4.5) under different treatment modalities and whether MR(4.5) predicts survival. PATIENTS AND METHODS Patients from the randomized CML-Study IV were analyzed for confirmed MR(4.5) which was defined as ≥ 4.5 log reduction of BCR-ABL on the international scale (IS) and determined by reverse transcriptase polymerase chain reaction in two consecutive analyses. Landmark analyses were performed to assess the impact of MR(4.5) on survival. RESULTS Of 1,551 randomly assigned patients, 1,524 were assessable. After a median observation time of 67.5 months, 5-year overall survival (OS) was 90%, 5-year progression-free-survival was 87.5%, and 8-year OS was 86%. The cumulative incidence of MR(4.5) after 9 years was 70% (median, 4.9 years); confirmed MR(4.5) was 54%. MR(4.5) was reached more quickly with optimized high-dose imatinib than with imatinib 400 mg/day (P = .016). Independent of treatment approach, confirmed MR(4.5) at 4 years predicted significantly higher survival probabilities than 0.1% to 1% IS, which corresponds to complete cytogenetic remission (8-year OS, 92% v 83%; P = .047). High-dose imatinib and early major molecular remission predicted MR(4.5). No patient with confirmed MR(4.5) has experienced progression. CONCLUSION MR(4.5) is a new molecular predictor of long-term outcome, is reached by a majority of patients treated with imatinib, and is achieved more quickly with optimized high-dose imatinib, which may provide an improved therapeutic basis for treatment discontinuation in CML.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND High-dose benzodiazepine (BZD) dependence is associated with a wide variety of negative health consequences. Affected individuals are reported to suffer from severe mental disorders and are often unable to achieve long-term abstinence via recommended discontinuation strategies. Although it is increasingly understood that treatment interventions should take subjective experiences and beliefs into account, the perceptions of this group of individuals remain under-investigated. METHODS We conducted an exploratory qualitative study with 41 adult subjects meeting criteria for (high-dose) BZD-dependence, as defined by ICD-10. One-on-one in-depth interviews allowed for an exploration of this group's views on the reasons behind their initial and then continued use of BZDs, as well as their procurement strategies. Mayring's qualitative content analysis was used to evaluate our data. RESULTS In this sample, all participants had developed explanatory models for why they began using BZDs. We identified a multitude of reasons that we grouped into four broad categories, as explaining continued BZD use: (1) to cope with symptoms of psychological distress or mental disorder other than substance use, (2) to manage symptoms of physical or psychological discomfort associated with somatic disorder, (3) to alleviate symptoms of substance-related disorders, and (4) for recreational purposes, that is, sensation-seeking and other social reasons. Subjects often considered BZDs less dangerous than other substances and associated their use more often with harm reduction than as recreational. Specific obtainment strategies varied widely: the majority of participants oscillated between legal and illegal methods, often relying on the black market when faced with treatment termination. CONCLUSIONS Irrespective of comorbidity, participants expressed a clear preference for medically related explanatory models for their BZD use. We therefore suggest that clinicians consider patients' motives for long-term, high-dose BZD use when formulating treatment plans for this patient group, especially since it is known that individuals are more compliant with approaches they perceive to be manageable, tolerable, and effective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND High-dose benzodiazepine dependence constitutes a major clinical concern. Although withdrawal treatment is recommended, it is unsuccessful for a significant proportion of affected patients. More recently, a benzodiazepine maintenance approach has been suggested as an alternative for patients' failing discontinuation treatment. While there is some data supporting its effectiveness, patients' perceptions of such an intervention have not been investigated. METHODS An exploratory qualitative study was conducted among a sample of 41 high-dose benzodiazepine (BZD)-dependent patients, with long-term use defined as doses equivalent to more than 40 mg diazepam per day and/or otherwise problematic use, such as mixing substances, dose escalation, recreational use, or obtainment by illegal means. A qualitative content analysis approach was used to evaluate findings. RESULTS Participants generally favored a treatment discontinuation approach with abstinence from BZD as its ultimate aim, despite repeated failed attempts at withdrawal. A maintenance treatment approach with continued prescription of a slow-onset, long-acting agonist was viewed ambivalently, with responses ranging from positive and welcoming to rejection. Three overlapping themes of maintenance treatment were identified: "Only if I can try to discontinue…and please don't call it that," "More stability and less criminal activity…and that is why I would try it," and "No cure, no brain and no flash…and thus, just for everybody else!" CONCLUSIONS Some patients experienced slow-onset, long-acting BZDs as having stabilized their symptoms and viewed these BZDs as having helped avoid uncontrolled withdrawal and abstain from criminal activity. We therefore encourage clinicians to consider treatment alternatives if discontinuation strategies fail.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to directly compare metal artifact reduction (MAR) of virtual monoenergetic extrapolations (VMEs) from dual-energy computed tomography (CT) with iterative MAR (iMAR) from single energy in pelvic CT with hip prostheses. MATERIALS AND METHODS A human pelvis phantom with unilateral or bilateral metal inserts of different material (steel and titanium) was scanned with third-generation dual-source CT using single (120 kVp) and dual-energy (100/150 kVp) at similar radiation dose (CT dose index, 7.15 mGy). Three image series for each phantom configuration were reconstructed: uncorrected, VME, and iMAR. Two independent, blinded radiologists assessed image quality quantitatively (noise and attenuation) and subjectively (5-point Likert scale). Intraclass correlation coefficients (ICCs) and Cohen κ were calculated to evaluate interreader agreements. Repeated measures analysis of variance and Friedman test were used to compare quantitative and qualitative image quality. Post hoc testing was performed using a corrected (Bonferroni) P < 0.017. RESULTS Agreements between readers were high for noise (all, ICC ≥ 0.975) and attenuation (all, ICC ≥ 0.986); agreements for qualitative assessment were good to perfect (all, κ ≥ 0.678). Compared with uncorrected images, VME showed significant noise reduction in the phantom with titanium only (P < 0.017), and iMAR showed significantly lower noise in all regions and phantom configurations (all, P < 0.017). In all phantom configurations, deviations of attenuation were smallest in images reconstructed with iMAR. For VME, there was a tendency toward higher subjective image quality in phantoms with titanium compared with uncorrected images, however, without reaching statistical significance (P > 0.017). Subjective image quality was rated significantly higher for images reconstructed with iMAR than for uncorrected images in all phantom configurations (all, P < 0.017). CONCLUSIONS Iterative MAR showed better MAR capabilities than VME in settings with bilateral hip prosthesis or unilateral steel prosthesis. In settings with unilateral hip prosthesis made of titanium, VME and iMAR performed similarly well.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Newly diagnosed WHO grade II-III or any WHO grade recurrent meningioma exhibit an aggressive behavior and thus are considered as high- or intermediate risk tumors. Given the unsatisfactory rates of disease control and survival after primary or adjuvant radiation therapy, optimization of treatment strategies is needed. We investigated the potential of dose-painting intensity-modulated proton beam-therapy (IMPT) for intermediate- and high-risk meningioma. MATERIAL AND METHODS Imaging data from five patients undergoing proton beam-therapy were used. The dose-painting target was defined using [68]Ga-[1,4,7,10-tetraazacyclododecane tetraacetic acid]- d-Phe(1),Tyr(3)-octreotate ([68]Ga-DOTATATE)-positron emission tomography (PET) in target delineation. IMPT and photon intensity-modulated radiation therapy (IMRT) treatment plans were generated for each patient using an in-house developed treatment planning system (TPS) supporting spot-scanning technology and a commercial TPS, respectively. Doses of 66 Gy (2.2 Gy/fraction) and 54 Gy (1.8 Gy/fraction) were prescribed to the PET-based planning target volume (PTVPET) and the union of PET- and anatomical imaging-based PTV, respectively, in 30 fractions, using simultaneous integrated boost. RESULTS Dose coverage of the PTVsPET was equally good or slightly better in IMPT plans: dose inhomogeneity was 10 ± 3% in the IMPT plans vs. 13 ± 1% in the IMRT plans (p = 0.33). The brain Dmean and brainstem D50 were small in the IMPT plans: 26.5 ± 1.5 Gy(RBE) and 0.002 ± 0.0 Gy(RBE), respectively, vs. 29.5 ± 1.5 Gy (p = 0.001) and 7.5 ± 11.1 Gy (p = 0.02) for the IMRT plans, respectively. The doses delivered to the optic structures were also decreased with IMPT. CONCLUSIONS Dose-painting IMPT is technically feasible using currently available planning tools and resulted in dose conformity of the dose-painted target comparable to IMRT with a significant reduction of radiation dose delivered to the brain, brainstem and optic apparatus. Dose escalation with IMPT may improve tumor control and decrease radiation-induced toxicity.