48 resultados para Dimensional measurement accuracy


Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM Depending on intensity, exercise may induce a strong hormonal and metabolic response, including acid-base imbalances and changes in microcirculation, potentially interfering with the accuracy of continuous glucose monitoring (CGM). The present study aimed at comparing the accuracy of the Dexcom G4 Platinum (DG4P) CGM during continuous moderate and intermittent high-intensity exercise (IHE) in adults with type 1 diabetes (T1DM). METHODS Ten male individuals with well-controlled T1DM (HbA1c 7.0±0.6% [54±6mmol/mol]) inserted the DG4P sensor 2 days prior to a 90min cycling session (50% VO2peak) either with (IHE) or without (CONT) a 10s all-out sprint every 10min. Venous blood samples for reference glucose measurement were drawn every 10min and euglycemia (target 7mmol/l) was maintained using an oral glucose solution. Additionally, lactate and venous blood gas variables were determined. RESULTS Mean reference blood glucose was 7.6±0.2mmol/l during IHE and 6.7±0.2mmol/l during CONT (p<0.001). IHE resulted in significantly higher levels of lactate (7.3±0.5mmol/l vs. 2.6±0.3mmol/l, p<0.001), while pH values were significantly lower in the IHE group (7.27 vs. 7.38, p=0.001). Mean absolute relative difference (MARD) was 13.3±2.2% for IHE and 13.6±2.8% for CONT suggesting comparable accuracy (p=0.90). Using Clarke Error Grid Analysis, 100% of CGM values during both IHE and CONT were in zones A and B (IHE: 77% and 23%; CONT: 78% and 22%). CONCLUSIONS The present study revealed good and comparable accuracy of the DG4P CGM system during intermittent high intensity and continuous moderate intensity exercise, despite marked differences in metabolic conditions. This corroborates the clinical robustness of CGM under differing exercise conditions. CLINICAL TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT02068638.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT The polyuria-polydipsia syndrome comprises primary polydipsia (PP) and central and nephrogenic diabetes insipidus (DI). Correctly discriminating these entities is mandatory, given that inadequate treatment causes serious complications. The diagnostic "gold standard" is the water deprivation test with assessment of arginine vasopressin (AVP) activity. However, test interpretation and AVP measurement are challenging. OBJECTIVE The objective was to evaluate the accuracy of copeptin, a stable peptide stoichiometrically cosecreted with AVP, in the differential diagnosis of polyuria-polydipsia syndrome. DESIGN, SETTING, AND PATIENTS This was a prospective multicenter observational cohort study from four Swiss or German tertiary referral centers of adults >18 years old with the history of polyuria and polydipsia. MEASUREMENTS A standardized combined water deprivation/3% saline infusion test was performed and terminated when serum sodium exceeded 147 mmol/L. Circulating copeptin and AVP levels were measured regularly throughout the test. Final diagnosis was based on the water deprivation/saline infusion test results, clinical information, and the treatment response. RESULTS Fifty-five patients were enrolled (11 with complete central DI, 16 with partial central DI, 18 with PP, and 10 with nephrogenic DI). Without prior thirsting, a single baseline copeptin level >21.4 pmol/L differentiated nephrogenic DI from other etiologies with a 100% sensitivity and specificity, rendering a water deprivation testing unnecessary in such cases. A stimulated copeptin >4.9 pmol/L (at sodium levels >147 mmol/L) differentiated between patients with PP and patients with partial central DI with a 94.0% specificity and a 94.4% sensitivity. A stimulated AVP >1.8 pg/mL differentiated between the same categories with a 93.0% specificity and a 83.0% sensitivity. LIMITATION This study was limited by incorporation bias from including AVP levels as a diagnostic criterion. CONCLUSION Copeptin is a promising new tool in the differential diagnosis of the polyuria-polydipsia syndrome, and a valid surrogate marker for AVP. Primary Funding Sources: Swiss National Science Foundation, University of Basel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Canine S100 calcium-binding protein A12 (cS100A12) shows promise as biomarker of inflammation in dogs. A previously developed cS100A12-radioimmunoassay (RIA) requires radioactive tracers and is not sensitive enough for fecal cS100A12 concentrations in 79% of tested healthy dogs. An ELISA assay may be more sensitive than RIA and does not require radioactive tracers. OBJECTIVE The purpose of the study was to establish a sandwich ELISA for serum and fecal cS100A12, and to establish reference intervals (RI) for normal healthy canine serum and feces. METHODS Polyclonal rabbit anti-cS100A12 antibodies were generated and tested by Western blotting and immunohistochemistry. A sandwich ELISA was developed and validated, including accuracy and precision, and agreement with cS100A12-RIA. The RI, stability, and biologic variation in fecal cS100A12, and the effect of corticosteroids on serum cS100A12 were evaluated. RESULTS Lower detection limits were 5 μg/L (serum) and 1 ng/g (fecal), respectively. Intra- and inter-assay coefficients of variation were ≤ 4.4% and ≤ 10.9%, respectively. Observed-to-expected ratios for linearity and spiking recovery were 98.2 ± 9.8% (mean ± SD) and 93.0 ± 6.1%, respectively. There was a significant bias between the ELISA and the RIA. The RI was 49-320 μg/L for serum and 2-484 ng/g for fecal cS100A12. Fecal cS100A12 was stable for 7 days at 23, 4, -20, and -80°C; biologic variation was negligible but variation within one fecal sample was significant. Corticosteroid treatment had no clinically significant effect on serum cS100A12 concentrations. CONCLUSIONS The cS100A12-ELISA is a precise and accurate assay for serum and fecal cS100A12 in dogs.