51 resultados para wire


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Prolonged sacral neuromodulation (SNM) testing is more reliable for accurate patient selection than the usual test period of 4-7 days. However, prolonged testing was suspected to result in a higher complication rate due to infection via the percutaneous passage of the extension wire. Therefore, we prospectively assessed the complications associated with prolonged tined lead testing. PATIENTS AND METHODS: A consecutive series of 44 patients who underwent prolonged tined lead testing for at least 14 days between May 2002 and April 2007 were evaluated. Complications during prolonged tined lead testing, during and after tined lead explantation and during follow-up after implantation of the implantable pulse generator (IPG) were registered prospectively. RESULTS: Four patients suffered from urgency-frequency syndrome, 13 from urge incontinence, 18 from non-obstructive chronic urinary retention and nine from chronic pelvic pain syndrome. The median test phase was 30 days (interquartile range [IQR] 21-36). Thirty-two of the 44 patients (73%) had successful prolonged tined lead testing and 31 of these (97%) underwent the implantation of the IPG. The median follow-up of the IPG implanted patients was 31 months (IQR 20-41). The complication rate was 5% (2/44) during prolonged tined lead testing and 16% (5/31) during follow-up of the IPG implanted patients, respectively. None of the complications could be attributed to prolonged testing. No infections were observed during the study period. CONCLUSIONS: This prospective, observational non-randomised study suggests prolonged SNM tined lead testing is a safe procedure. Based on the low complication rate and the increased reliability for accurate patient selection, this method is proposed as a possible standard test procedure, subject to confirmation by further randomised, controlled clinical studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the past decade microbeam radiation therapy has evolved from preclinical studies to a stage in which clinical trials can be planned, using spatially fractionated, highly collimated and high intensity beams like those generated at the x-ray ID17 beamline of the European Synchrotron Radiation Facility. The production of such microbeams typically between 25 and 100 microm full width at half maximum (FWHM) values and 100-400 microm center-to-center (c-t-c) spacings requires a multislit collimator either with fixed or adjustable microbeam width. The mechanical regularity of such devices is the most important property required to produce an array of identical microbeams. That ensures treatment reproducibility and reliable use of Monte Carlo-based treatment planning systems. New high precision wire cutting techniques allow the fabrication of these collimators made of tungsten carbide. We present a variable slit width collimator as well as a single slit device with a fixed setting of 50 microm FWHM and 400 microm c-t-c, both able to cover irradiation fields of 50 mm width, deemed to meet clinical requirements. Important improvements have reduced the standard deviation of 5.5 microm to less than 1 microm for a nominal FWHM value of 25 microm. The specifications of both devices, the methods used to measure these characteristics, and the results are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: Closed reduction and internal fixation by an anterior approach is an established option for operative treatment of displaced Type II odontoid fractures. In elderly patients, however, inadequate screw purchase in osteoporotic bone can result in severe procedure-related complications. PURPOSE: To improve the stability of odontoid fracture screw fixation in the elderly using a new technique that includes injection of polymethylmethacrylat (PMMA) cement into the C2 body. STUDY DESIGN: Retrospective review of hospital and outpatient records as well as radiographs of elderly patients treated in a university hospital department of orthopedic surgery. PATIENT SAMPLE: Twenty-four elderly patients (8 males and 16 females; mean age, 81 years; range, 62-98 years) with Type II fractures of the dens. OUTCOME MEASURES: Complications, cement leakage (symptomatic/asymptomatic), operation time, loss of reduction, pseudarthrosis and revision surgery, patient complaints, return to normal activities, and signs of neurologic complications were all documented. METHODS: After closed reduction and anterior approach to the inferior border of C2, a guide wire is advanced to the tip of the odontoid under biplanar fluoroscopic control. Before the insertion of one cannulated, self-drilling, short thread screws, a 12 gauge Yamshidi cannula is inserted from anterior and 1 to 3 mL of high-viscosity PMMA cement is injected into the anteroinferior portion of the C2 body. During polymerization of the cement, the screws are further inserted using a lag-screw compression technique. The cervical spine then is immobilized with a soft collar for 8 weeks postoperatively. RESULTS: Anatomical reduction of the dens was achieved in all 24 patients. Mean operative time was 64 minutes (40-90 minutes). Early loss of reduction occurred in three patients, but revision surgery was indicated in only one patient 2 days after primary surgery. One patient died within the first eight postoperative weeks, one within 3 months after surgery. In five patients, asymptomatic cement leakage was observed (into the C1-C2 joint in three patients, into the fracture in two). Conventional radiologic follow-up at 2 and 6 months confirmed anatomical healing in 16 of the19 patients with complete follow-up. In two patients, the fractures healed in slight dorsal angulation; one patient developed a asymptomatic pseudarthrosis. All patients were able to resume their pretrauma level of activity. CONCLUSIONS: Cement augmentation of the screw in Type II odontoid fractures in elderly patients is technically feasible in a clinical setting with a low complication rate. This technique may improve screw purchase, especially in the osteoporotic C2 body.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets generated the highest moments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on three identical maxillary acrylic resin models, with a palatally displaced right lateral incisor. The transfer trays for the indirect bonding of the lingual brackets were constructed in certified laboratories. Each model was mounted on the orthodontic measurement and simulation system and ten 0.013 inch CuNiTi wires were used for each bracket type. The wire was ligated with elastomerics and each measurement was repeated once after re-ligation. The labiopalatal forces and the moments in the sagittal plane were recorded on the right lateral incisor. One-way analysis of variance and post hoc Scheffe pairwise comparisons were used to assess the effect on bracket type on the generated forces and moments. The magnitude of forces ranged from 1.62, 1.27, and 1.81 N for the STb, conventional, and Incognito brackets, respectively; the corresponding moments were 2.01, 1.45, and 2.19 N mm, respectively. Bracket type was a significant predictor of the generated forces (P < 0.001) and moments (P < 0.001). The produced forces were different among all three bracket types, whereas the generated moments differed between conventional and lingual brackets but not between lingual brackets.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Percutaneous closure of the transapical (TA) access site for large-calibre devices is an unsolved issue. We report the first experimental data on the TA PLUG device for true-percutaneous closure following large apical access for transcatheter aortic valve implantation. METHODS The TA PLUG, a self-sealing full-core closure device, was implanted in an acute animal study in six pigs (60.2 ± 0.7 kg). All the pigs received 100 IU/kg of heparin. The targeted activated clotting time was left to normalize spontaneously. After accessing the left ventricular apex with a 39 French introducer, the closure plug device was delivered with a 33 French over-the-wire system under fluoroscopic guidance into the apex. Time to full haemostasis as well as rate of bleeding was recorded. Self-anchoring properties were assessed by haemodynamic push stress under adrenalin challenge. An additional feasibility study was conducted in four pigs (58.4 ± 1.1 kg) with full surgical exposure of the apex, and assessed device anchoring by pull-force measurements with 0.5 Newton (N) increments. All the animals were electively sacrified. Post-mortem analysis of the heart was performed and the renal embolic index assessed. RESULTS Of six apical closure devices, five were correctly inserted and fully deployed at the first attempt. One became blocked in the delivery system and was placed successfully at the second attempt. In all the animals, complete haemostasis was immediate and no leak was recorded during the 5-h observation period. Neither leak nor any device dislodgement was observed under haemodynamic push stress with repeated left ventricular peak pressure of up to 220 mmHg. In the feasibility study assessing pull-stressing, device migration occurred at a force of 3.3 ± 0.5 N corresponding to 247.5 mmHg. Post-mortem analyses confirmed full expansion of all devices at the intended target. No macroscopic damage was identified at the surrounding myocardium. The renal embolic index was zero. CONCLUSIONS True-percutaneous left ventricular apex closure following large access is feasible with the self-sealing TA PLUG. The device allows for immediate haemostasis and a reliable anchoring in the acute animal setting. This is the first report of a true-percutaneous closure for large-calibre transcatheter aortic valve implantation access.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STUDY DESIGN Descriptive anatomical study on ovine and human cadaveric lumbar spinal segments. OBJECTIVE To describe the alternative transpedicular approach to deliver therapeutic agents into intervertebral disc (IVD). SUMMARY OF BACKGROUND DATA The present delivery approach of therapeutic agents (growth factors/cells/hydrogels) within the IVD is through injection, via the annulus fibrosus (AF). However, it has recently been demonstrated that small needle puncture of the AF leads to further degeneration and disc herniation. In addition, the injected material has a high chance to be extruded through the AF injury. METHODS Lumbar ovine and human spinal segments were used. Under fluoroscopy, a 2-mm Kirschner wire was introduced in the caudal vertebra through the pedicle and the inferior endplate to the nucleus pulposus. Gross anatomy analysis and high-resolution peripheral quantitative computed tomography (HR-pQCT) were performed to assess the right position of the wire in pedicles. Discography and nucleotomy were performed using a 14G cannula insertion or a 2-mm arthroscopic shaver blade, respectively. Nucleoplasty was also performed with agarose gel/contrast agent and imaged with HR-pQCT. RESULTS Gross anatomy, fluoroscopy, and HR-pQCT images showed that the nucleus pulposus could be approached through the endplate via the pedicle without affecting the spinal canal and the neural foramina. The contrast agent was delivered into the IVD and nucleus pulposus was removed from the disc and filled with agarose gel. CONCLUSION This study describes how a transpedicular approach can be used as an alternative route to deliver therapeutic agents to the disc without disruption of the AF showing the potential use of this technique in preclinical research and highlighting its clinical relevance for IVD regeneration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The use of ultrathin Doppler angioplasty guidewires has made it possible to measure collateral flow quantitatively. Pharmacologic interventions have been shown to influence collateral flow and, thus, to affect myocardial ischaemia. METHODS Twenty-five patients with coronary artery disease undergoing PTCA were included in the present analysis. Coronary flow velocities were measured in the ipsilateral (n = 25) and contralateral (n = 6; two Doppler wires) vessels during PTCA with and without i.v. adenosine (140 microg/kg.min) before and 3 min after 5 mg metoprolol i.v., respectively. The ipsilateral Doppler wire was positioned distal to the stenosis, whereas the distal end of the contralateral wire was in an angiographically normal vessel. The flow signals of the ipsilateral wire were used to calculate the collateral flow index (CFI). CFI was defined as the ratio of flow velocity during balloon inflation divided by resting flow. RESULTS Heart rate and mean aortic pressure decreased slightly (ns) after i.v. metoprolol. The collateral flow index was 0.25+/-0.12 (one fourth of the resting coronary flow) during the first PTCA and 0.27+/-0.14 (ns versus first PTCA) during the second PTCA, but decreased with metoprolol to 0.16+/-0.08 (p<0.0001 vs. baseline) during the third PTCA. CONCLUSIONS Coronary collateral flow increased slightly but not significantly during maximal vasodilatation with adenosine but decreased in 23 of 25 patients after i.v. metoprolol. Thus, there is a reduction in coronary collateral flow with metoprolol, probably due to an increase in coronary collateral resistance or a reduction in oxygen demand.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Fixation of periprosthetic hip fractures with intracortical anchorage might not be feasible in cases with bulky implants and/or poor bone stock. METHODS Rotational stability of new plate inserts with extracortical anchorage for cerclage fixation was measured and compared to the stability found using a standard technique in a biomechanical setup using a torsion testing machine. In a synthetic PUR bone model, transverse fractures were fixed distally using screws and proximally by wire cerclages attached to the plates using "new" (extracortical anchorage) or "standard" (intracortical anchorage) plate inserts. Time to fracture consolidation and complications were assessed in a consecutive series of 18 patients (18 female; mean age 81 years, range 55-92) with periprosthetic hip fractures (ten type B1, eight type C-Vancouver) treated with the new device between July 2003 and July 2010. RESULTS The "new" device showed a higher rotational stability than the "standard" technique (p < 0.001). Fractures showed radiographic consolidation after 14 ± 5 weeks (mean ± SD) postoperatively in patients. Revision surgery was necessary in four patients, unrelated to the new technique. CONCLUSION In periprosthetic hip fractures in which fixation with intracortical anchorage using conventional means might be difficult due to bulky revision stems and/or poor bone stock, the new device may be an addition to the range of existing implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper addresses the microscale heat transfer problem from heated lattice to the gas. A micro-device for enhanced heat transfer is presented and numerically investigated. Thermal creep induces 3-D vortex structures in the vicinity of the lattice. The gas flow is in the slip flow regime (Knudsen number Kn⩽0.1Kn⩽0.1). The simulations are performed using slip flow Navier–Stokes equations with boundary condition formulations proposed by Maxwell and Smoluchowski. In this study the wire thicknesses and distances of the heated lattice are varied. The surface geometrical properties alter significantly heat flux through the surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Arterial waves are seen as possible independent mediators of cardiovascular risks, and the wave intensity analysis (WIA) has therefore been proposed as a method for patient selection for ventricular assist device (VAD) implantation. Interpreting measured wave intensity (WI) is challenging and complexity is increased by the implantation of a VAD. The waves generated by the VAD interact with the waves generated by the native heart, and this interaction varies with changing VAD settings. Eight sheep were implanted with a pulsatile VAD (PVAD) through ventriculo-aortic cannulation. The start of PVAD ejection was synchronized to the native R-wave and delayed between 0 % - 90 % of the cardiac cycle in 10 % steps or phase shifts (PS). Pressure and velocity signals were registered, using a combined Doppler and pressure wire positioned in the abdominal aorta, and used to calculate the WI. Depending on the PS, different wave interference phenomena occurred. Maximum unloading of the left ventricle (LV) coincided with constructive interference and maximum blood flow pulsatility, and maximum loading of the LV coincided with destructive interference and minimum blood flow pulsatility. We believe, that non-invasive WIA could potentially be used clinically to assess the mechanical load of the LV, and to monitor the peripheral hemodynamics such as blood flow pulsatility and risk of intestinal bleeding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To survey retention procedures used in orthodontic practices in Switzerland. MATERIAL AND METHODS A questionnaire previously developed by Renkema et al. (2009) was sent to 223 Swiss orthodontists. The questionnaire comprised six parts, mainly containing multiple-choice questions. Information as to background education of the individual orthodontist, retention in general, frequency of different types of removable or bonded retainers that were used, retention pro- tocol, and the type and size of the wire used for bonded retainers was assessed. RESULTS The overall response rate was 65 percent. Most orthodontists placed a bonded retainer in the upper and lower arch, except when the upper arch was expanded during treatment or when extractions were performed in the upper arch, in which case they placed a combination of fixed and removable retainers. Opinions varied with regard to how many hours the removable retainers should be worn and the duration of the retention phase. As far as bonded retainers were concerned, 87 percent of the orthodontists preferred life-long retention. Ninety-three percent of the orthodontists considered that the development of a guide- line on retention procedures would be useful. CONCLUSIONS The choice of retention procedures is mostly based on orthodontists personal preference. A further research into the long-term effectiveness of individual retention protocols is needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Le collage d’un fil torsadé souple sur les faces linguales des six dents antérieures mandibulaires est une modalité de contention couramment utilisée. Les complications sont rares mais peuvent être assez sérieuses pour provoquer des dégâts biologiques. Cet article présente une complication sérieuse d’un fil de contention torsadé souple, collé en lingual. Quatre ans après son traitement orthodontique, un homme de 20 ans a consulté pour la rupture d’un fil de contention torsadé souple. L’examen clinique a montré un torque radiculo-vestibulaire d’environ 35° d’une dent. Une image en tomographie volumique à faisceau conique (Cone-Beam Computed Tomography ou CBCT) a montré que la racine et l’apex de la dent étaient presque totalement hors de l’os du côté vestibulaire. Étonnamment, la vitalité de la dent était préservée. La dent a été ramenée presque jusqu’à sa position initiale; cliniquement, seule une récession gingivale a persisté. Les orthodontistes et les dentistes devraient être conscients des complications possibles des contentions collées. Les patients devraient être clairement informés de la manière dont les problèmes peuvent être détectés à un stade précoce.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Factorial designs for clinical trials are often encountered in medical, dental, and orthodontic research. Factorial designs assess two or more interventions simultaneously and the main advantage of this design is its efficiency in terms of sample size as more than one intervention may be assessed on the same participants. However, the factorial design is efficient only under the assumption of no interaction (no effect modification) between the treatments under investigation and, therefore, this should be considered at the design stage. Conversely, the factorial study design may also be used for the purpose of detecting an interaction between two interventions if the study is powered accordingly. However, a factorial design powered to detect an interaction has no advantage in terms of the required sample size compared to a multi-arm parallel trial for assessing more than one intervention. It is the purpose of this article to highlight the methodological issues that should be considered when planning, analysing, and reporting the simplest form of this design, which is the 2 × 2 factorial design. An example from the field of orthodontics using two parameters (bracket type and wire type) on maxillary incisor torque loss will be utilized in order to explain the design requirements, the advantages and disadvantages of this design, and its application in orthodontic research.