47 resultados para point of view


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point-of-care testing (POCT) remains under scrutiny by healthcare professionals because of its ill-tried, young history. POCT methods are being developed by a few major equipment companies based on rapid progress in informatics and nanotechnology. Issues as POCT quality control, comparability with standard laboratory procedures, standardisation, traceability and round robin testing are being left to hospitals. As a result, the clinical and operational benefits of POCT were first evident for patients on the operating table. For the management of cardiovascular surgery patients, POCT technology is an indispensable aid. Improvement of the technology has meant that clinical laboratory pathologists now recognise the need for POCT beyond their high-throughput areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An Internet survey demonstrated the existence of problems related to intraoperative tracking camera set-up and alignment. It is hypothesized that these problems are a result of the limited field of view of today's optoelectronic camera systems, which is usually insufficiently large to keep the entire site of surgical action in view during an intervention. A method is proposed to augment a camera's field of view by actively controlling camera orientation, enabling it to track instruments as they are used intraoperatively. In an experimental study, an increase of almost 300% was found in the effective volume in which instruments could be tracked.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The Roche CARDIAC proBNP point-of-care (POC) test is the first test intended for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in whole blood as an aid in the diagnosis of suspected congestive heart failure, in the monitoring of patients with compensated left-ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes. METHODS: A multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP test at seven different sites. RESULTS: The majority of all coefficients of variation (CVs) obtained for within-series imprecision using native blood samples was below 10% for both 52 samples measured ten times and for 674 samples measured in duplicate. Using quality control material, the majority of CV values for day-to-day imprecision were below 14% for the low control level and below 13% for the high control level. In method comparisons for four lots of the POC NT-proBNP test with the laboratory reference method (Elecsys proBNP), the slope ranged from 0.93 to 1.10 and the intercept ranged from 1.8 to 6.9. The bias found between venous and arterial blood with the POC NT-proBNP method was < or =5%. All four lots of the POC NT-proBNP test investigated showed excellent agreement, with mean differences of between -5% and +4%. No significant interference was observed with lipaemic blood (triglyceride concentrations up to 6.3 mmol/L), icteric blood (bilirubin concentrations up to 582 micromol/L), haemolytic blood (haemoglobin concentrations up to 62 mg/L), biotin (up to 10 mg/L), rheumatoid factor (up to 42 IU/mL), or with 50 out of 52 standard or cardiological drugs in therapeutic concentrations. With bisoprolol and BNP, somewhat higher bias in the low NT-proBNP concentration range (<175 ng/L) was found. Haematocrit values between 28% and 58% had no influence on the test result. Interference may be caused by human anti-mouse antibodies (HAMA) types 1 and 2. No significant influence on the results with POC NT-proBNP was found using volumes of 140-165 muL. High NT-proBNP concentrations above the measuring range of the POC NT-proBNP test did not lead to false low results due to a potential high-dose hook effect. CONCLUSIONS: The POC NT-proBNP test showed good analytical performance and excellent agreement with the laboratory method. The POC NT-proBNP assay is therefore suitable in the POC setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Thoracic epidural analgesia (TEA) is increasingly used for perioperative analgesia. If patients with TEA develop sepsis or systemic inflammatory response subsequent to extended surgery the question arises if it would be safe to continue TEA with its beneficial effects of improving gastrointestinal perfusion and augmenting tissue oxygenation. A major concern in this regard is hemodynamic instability that might ensue from TEA-induced vasodilation. The objective of the present study was to assess the effects of TEA on systemic and pulmonary hemodynamics in a sepsis model of hyperdynamic endotoxemia. METHODS: After a baseline measurement in healthy sheep (n = 14), Salmonella thyphosa endotoxin was continuously infused at a rate of 10 ngxkg(-1)xmin(-1) over 16 hours. The surviving animals (n = 12) were then randomly assigned to 1 of 2 study groups. In the treatment group (n = 6), continuous TEA was initiated with 0.1 mLxkg(-1) bupivacaine 0.125% and maintained with 0.1 mLxkg(-1)xh(-1). In the control group (n = 6) the same amount of isotonic sodium saline solution was injected at the same rate through the epidural catheter. RESULTS: In both experimental groups cardiac index increased and systemic vascular resistance decreased concurrently (each P < .05). Functional epidural blockade in the TEA group was confirmed by sustained suppression of the cutaneous (or panniculus) reflex. During the observational period of 6 hours neither systemic nor pulmonary circulatory variables were impaired by TEA. CONCLUSIONS: From a hemodynamic point of view, TEA presents as a safe treatment option in sepsis or systemic inflammatory response syndrome.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Bleeding is a frequent complication during surgery. The intraoperative administration of blood products, including packed red blood cells, platelets and fresh frozen plasma (FFP), is often live saving. Complications of blood transfusions contribute considerably to perioperative costs and blood product resources are limited. Consequently, strategies to optimize the decision to transfuse are needed. Bleeding during surgery is a dynamic process and may result in major blood loss and coagulopathy due to dilution and consumption. The indication for transfusion should be based on reliable coagulation studies. While hemoglobin levels and platelet counts are available within 15 minutes, standard coagulation studies require one hour. Therefore, the decision to administer FFP has to be made in the absence of any data. Point of care testing of prothrombin time ensures that one major parameter of coagulation is available in the operation theatre within minutes. It is fast, easy to perform, inexpensive and may enable physicians to rationally determine the need for FFP. METHODS/DESIGN: The objective of the POC-OP trial is to determine the effectiveness of point of care prothrombin time testing to reduce the administration of FFP. It is a patient and assessor blind, single center randomized controlled parallel group trial in 220 patients aged between 18 and 90 years undergoing major surgery (any type, except cardiac surgery and liver transplantation) with an estimated blood loss during surgery exceeding 20% of the calculated total blood volume or a requirement of FFP according to the judgment of the physicians in charge. Patients are randomized to usual care plus point of care prothrombin time testing or usual care alone without point of care testing. The primary outcome is the relative risk to receive any FFP perioperatively. The inclusion of 110 patients per group will yield more than 80% power to detect a clinically relevant relative risk of 0.60 to receive FFP of the experimental as compared with the control group. DISCUSSION: Point of care prothrombin time testing in the operation theatre may reduce the administration of FFP considerably, which in turn may decrease costs and complications usually associated with the administration of blood products. TRIAL REGISTRATION: NCT00656396.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: To validate the concept of early implant placement for use in the esthetically sensitive anterior maxilla, clinical trials should ideally include objective esthetic criteria when assessing outcome parameters. METHODS: In this cross-sectional, retrospective 2- to 4-year study involving 45 patients treated with maxillary anterior single-tooth implants according to the concept of early implant placement, a novel comprehensive index, comprising pink esthetic score and white esthetic score (PES/WES; the highest possible combined score is 20), was applied for the objective esthetic outcome assessment of anterior single-tooth implants. RESULTS: All 45 anterior maxillary single-tooth implants fulfilled strict success criteria for dental implants with regard to osseointegration, including the absence of peri-implant radiolucency, implant mobility, suppuration, and pain. The mean total PES/WES was 14.7 +/- 1.18 (range: 11 to 18). The mean total PES of 7.8 +/- 0.88 (range: 6 to 9) documents favorable overall peri-implant soft tissue conditions. The two PES variables facial mucosa curvature (1.9 +/- 0.29) and facial mucosa level (1.8 +/- 0.42) had the highest mean values, whereas the combination variable root convexity/soft tissue color and texture (1.2 +/- 0.53) proved to be the most difficult to fully satisfy. Mean scores were 1.6 +/- 0.5 for the mesial papilla and 1.3 +/- 0.5 for the distal papilla. A mean value of 6.9 +/- 1.47 (range: 4 to 10) was calculated for WES. CONCLUSIONS: This study demonstrated that anterior maxillary single-tooth replacement, according to the concept of early implant placement, is a successful and predictable treatment modality, in general, and from an esthetic point of view, in particular. The suitability of the PES/WES index for the objective outcome assessment of the esthetic dimension of anterior single-tooth implants was confirmed. However, prospective clinical trials are needed to further validate and refine this index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical aspects of reconstruction with fix prosthesis and dental implants in a patient with a history of periodontitis is shown. A successful stabilization and rehabilitation of the periodontally involved dentition can be achieved with tooth-worn crown and bridge reconstructions. From a functional and aesthetic point of view the result may not be satisfying due to mobility and overlength of the teeth and open approximal spaces. Today, dentist and patient have often to weigh if teeth shall be maintained or replaced by dental implants. Thereby, both must be aware of the fact that in complex cases long-term success and aesthetic outcome may be difficult to predict. An intense discussion with the patient on his expectations, invasive treatment, risks with regard to biologic and prosthetic aspects is mandatory and must be based on the best scientific evidence available. The present case report shows different considerations and describes a radical solution which meets the patient's needs and is based on modern CAD-CAM technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the nature of the blood groups A and B has been comprehensively studied for a long time, it is still unclear as to what exactly is the epitope that is recognized by antibodies having AB specificity, i.e. monoclonal and polyclonal antibodies which are capable of interacting equally well with the antigens GalNAcalpha 1-3(Fucalpha 1-2)Gal (A trisaccharide) and Galalpha 1-3(Fucalpha 1-2)Gal (B trisaccharide), but do not react with their common fragment Fucalpha 1-2Gal. We have supposed that besides Fucalpha 1-2Gal, A and B antigens have one more shared epitope. The trisaccharides A and B are practically identical from the conformational point of view, the only difference being situated at position 2 of Galalpha residue, i.e. trisaccharide A has a NHAc group, whereas trisaccharide B has a hydroxyl group (see formulas). We have hypothesized that the AB-epitope should be situated in the part of the molecule that is opposite to the NHAc group of GalNAc residue. In order to test this hypothesis we have synthesized a polymeric conjugate in such a way that de-N-acetylated A-trisaccharide is attached to a polymer via the nitrogen in position C-2 of the galactosamine residue. In this conjugate the supposed AB-epitope should be maximally accessible for antibodies from the solution, whereas the discrimination site of antigens A and B by the antibodies should be maximally hidden due to the close proximity of the polymer. Interaction with several anti-AB monoclonal antibodies revealed that a part of them really interacted with the synthetic AB-glycotope, thus confirming our hypothesis. Moreover, similar antibodies were revealed in the blood of healthy blood group 0 donors. Analysis of spatial models was performed in addition to identify the hydroxyl groups of Fuc, Galalpha, and Galbeta residues, which are particularly involved in the composition of the AB-glycotope.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High density spatial and temporal sampling of EEG data enhances the quality of results of electrophysiological experiments. Because EEG sources typically produce widespread electric fields (see Chapter 3) and operate at frequencies well below the sampling rate, increasing the number of electrodes and time samples will not necessarily increase the number of observed processes, but mainly increase the accuracy of the representation of these processes. This is namely the case when inverse solutions are computed. As a consequence, increasing the sampling in space and time increases the redundancy of the data (in space, because electrodes are correlated due to volume conduction, and time, because neighboring time points are correlated), while the degrees of freedom of the data change only little. This has to be taken into account when statistical inferences are to be made from the data. However, in many ERP studies, the intrinsic correlation structure of the data has been disregarded. Often, some electrodes or groups of electrodes are a priori selected as the analysis entity and considered as repeated (within subject) measures that are analyzed using standard univariate statistics. The increased spatial resolution obtained with more electrodes is thus poorly represented by the resulting statistics. In addition, the assumptions made (e.g. in terms of what constitutes a repeated measure) are not supported by what we know about the properties of EEG data. From the point of view of physics (see Chapter 3), the natural “atomic” analysis entity of EEG and ERP data is the scalp electric field

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This brief review focuses on health and biological function as cornerstones of fish welfare. From the function-based point of view, good welfare is reflected in the ability of the animal to cope with infectious and non-infectious stressors, thereby maintaining homeostasis and good health, whereas stressful husbandry conditions and protracted suffering will lead to the loss of the coping ability and, thus, to impaired health. In the first part of the review, the physiological processes through which stressful husbandry conditions modulate health of farmed fish are examined. If fish are subjected to unfavourable husbandry conditions, the resulting disruption of internal homeostasis necessitates energy-demanding physiological adjustments (allostasis/acclimation). The ensuing energy drain leads to trade-offs with other energy-demanding processes such as the functioning of the primary epithelial barriers (gut, skin, gills) and the immune system. Understanding of the relation between husbandry conditions, allostatic responses and fish health provides the basis for the second theme developed in this review, the potential use of biological function and health parameters as operational welfare indicators (OWIs). Advantages of function- and health-related parameters are that they are relatively straightforward to recognize and to measure and are routinely monitored in most aquaculture units, thereby providing feasible tools to assess fish welfare under practical farming conditions. As the efforts to improve fish welfare and environmental sustainability lead to increasingly diverse solutions, in particular integrated production, it is imperative that we have objective OWIs to compare with other production forms, such as high-density aquaculture. However, to receive the necessary acceptance for legislation, more robust scientific backing of the health- and function-related OWIs is urgently needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Monitoring of HIV viral load in patients on combination antiretroviral therapy (ART) is not generally available in resource-limited settings. We examined the cost-effectiveness of qualitative point-of-care viral load tests (POC-VL) in sub-Saharan Africa. DESIGN Mathematical model based on longitudinal data from the Gugulethu and Khayelitsha township ART programmes in Cape Town, South Africa. METHODS Cohorts of patients on ART monitored by POC-VL, CD4 cell count or clinically were simulated. Scenario A considered the more accurate detection of treatment failure with POC-VL only, and scenario B also considered the effect on HIV transmission. Scenario C further assumed that the risk of virologic failure is halved with POC-VL due to improved adherence. We estimated the change in costs per quality-adjusted life-year gained (incremental cost-effectiveness ratios, ICERs) of POC-VL compared with CD4 and clinical monitoring. RESULTS POC-VL tests with detection limits less than 1000 copies/ml increased costs due to unnecessary switches to second-line ART, without improving survival. Assuming POC-VL unit costs between US$5 and US$20 and detection limits between 1000 and 10,000 copies/ml, the ICER of POC-VL was US$4010-US$9230 compared with clinical and US$5960-US$25540 compared with CD4 cell count monitoring. In Scenario B, the corresponding ICERs were US$2450-US$5830 and US$2230-US$10380. In Scenario C, the ICER ranged between US$960 and US$2500 compared with clinical monitoring and between cost-saving and US$2460 compared with CD4 monitoring. CONCLUSION The cost-effectiveness of POC-VL for monitoring ART is improved by a higher detection limit, by taking the reduction in new HIV infections into account and assuming that failure of first-line ART is reduced due to targeted adherence counselling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The aim was to study the impact of the defect size of endodontically treated incisors compared to dental implants as abutments on the survival of zirconia two-unit anterior cantilever-fixed partial dentures (2U-FPDs) during 10-year simulation. MATERIALS AND METHODS Human maxillary central incisors were endodontically treated and divided into three groups (n = 24): I, access cavities rebuilt with composite core; II, teeth decoronated and restored with composite; and III as II supported by fiber posts. In group IV, implants with individual zirconia abutments were used. Specimens were restored with zirconia 2U-FPDs and exposed to two sequences of thermal cycling and mechanical loading. Statistics: Kaplan-Meier; log-rank tests. RESULTS During TCML in group I two tooth fractures and two debondings with chipping were found. Solely chippings occurred in groups II (2×), IV (2×), and III (1×). No significant different survival was found for the different abutments (p = 0.085) or FPDs (p = 0.526). Load capability differed significantly between groups I (176 N) and III (670 N), and III and IV (324 N) (p < 0.024). CONCLUSION Within the limitations of an in vitro study, it can be concluded that zirconia-framework 2U-FPDs on decoronated teeth with/without post showed comparable in vitro reliability as restorations on implants. The results indicated that restorations on teeth with only access cavity perform worse in survival and linear loading. CLINICAL RELEVANCE Even severe defects do not justify per se a replacement of this particular tooth by a dental implant from load capability point of view.