52 resultados para minimally processed


Relevância:

20.00% 20.00%

Publicador:

Resumo:

What's known on the subject? and What does the study add? The EndoSew® prototype was first tested in a porcine model several years ago. The investigators found it both simple to master and reliable, its greatest advantage being a 2.4-fold time saving compared with straight laparoscopic suturing. In addition to that publication, there is a single case report describing the performance of an open EndoSew® suture to close parts (16 cm) of an ileal neobladder. The time for suturing the 16 cm ileum was 25 min, which is in line with our experience. The knowledge on this subject is limited to these two publications. We report on the first consecutive series of ileal conduits performed in humans using the novel prototype sewing device EndoSew®. The study shows that the beginning and the end of the suture process represent the critical procedural steps. It also shows that, overall, the prototype sewing machine has the potential to facilitate the intracorporeal suturing required in reconstructive urology for construction of urinary diversions. Objective To evaluate the feasibility and safety of the novel prototype sewing device EndoSew® in placing an extracorporeal resorbable running suture for ileal conduits. Patients and Methods We conducted a prospective single-centre pilot study of 10 consecutive patients undergoing ileal conduit, in whom the proximal end of the ileal conduit was closed extracorporeally using an EndoSew® running suture. The primary endpoint was the safety of the device and the feasibility of the sewing procedure which was defined as a complete watertight running suture line accomplished by EndoSew® only. Watertightness was assessed using methylene blue intraoperatively and by loopography on postoperative days 7 and 14. Secondary endpoints were the time requirements and complications ≤30 days after surgery. Results A complete EndoSew® running suture was feasible in nine patients; the suture had to be abandoned in one patient because of mechanical failure. In three patients, two additional single freehand stitches were needed to anchor the thread and to seal tiny leaks. Consequently, all suture lines in 6/10 patients were watertight with EndoSew® suturing alone and in 10/10 patients after additional freehand stitches. The median (range) sewing time was 5.5 (3–10) min and the median (range) suture length was 4.5 (2–5.5) cm. There were no suture-related complications. Conclusions The EndoSew® procedure is both feasible and safe. After additional freehand stitches in four patients all sutures were watertight. With further technical refinements, EndoSew® has the potential to facilitate the intracorporeal construction of urinary diversions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND While surgical navigation offers the opportunity to accurately place an acetabular component, questions remain as to the best goal for acetabular component positioning in individual patients. Overall functional orientation of the pelvis after surgery is one of the most important variables for the surgeon to consider when determining the proper goal for acetabular component orientation. QUESTIONS/PURPOSES We measured the variation in pelvic tilt in 30 patients before THA and the effect of THA on pelvic tilt in the same patients more than a year after THA. METHODS Each patient had a CT study for CT-based surgical navigation and standing and supine radiographs before and after surgery. Pelvic tilt was calculated for each of the radiographs using a novel and validated two-dimensional/three-dimensional matching technique. RESULTS Mean supine pelvic tilt changed less than 2°, from 4.4° ± 6.4° (range, -7.7° to 20.8°) before THA to 6.3° ± 6.6° (range, -5.7° to 19.6°) after THA. Mean standing pelvic tilt changed less than 1°, from 1.5° ± 7.2° (range, -13.1° to 12.8°) before THA to 2.0° ± 8.3° (range, -12.3° to 16.8°) after THA. Preoperative pelvic tilt correlated with postoperative tilt in both the supine (r(2) = 0.75) and standing (r(2) = 0.87) positions. CONCLUSIONS In this population, pelvic tilt had a small and predictable change after surgery. However, intersubject variability of pelvic tilt was high, suggesting preoperative pelvic tilt should be considered when determining desired acetabular component positioning on a patient-specific basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To test a new tiny-tipped intraoperative diagnostic tool that was designed to provide the surgeon with reliable stiffness data on the motion segment during microdiscectomy. A decrease in stiffness after nuclectomy and a measurable influence of muscle tension were assumed. If the influence of muscle tension on the motion segment could at least be ruled out, there should be no difference with regard to stiffness between women and men. If these criteria are met, this new intraoperative diagnostic tool could be used in further studies for objective decision-making regarding additional stabilization systems after microdiscectomy. METHODS: After evaluation of the influence of muscle relaxation during in vivo measurements with a spinal spreader between the spinous processes, 21 motion segments were investigated in 21 patients. Using a standardized protocol, including quantified muscle relaxation, spinal stiffness was measured before laminotomy and after nuclectomy. RESULTS: The decrease in stiffness after microdiscectomy was highly significant. There were no statistically significant differences between men and women. The average stiffness value before discectomy was 33.7 N/mm, and it decreased to 25.6 N/mm after discectomy. The average decrease in stiffness was 8.1 N/mm (24%). CONCLUSION: In the moderately degenerated spine, stiffness decreases significantly after microdiscectomy. Control for muscle relaxation is essential when measuring in vivo spinal stiffness. The new spinal spreader was found to provide reliable data. This spreader could be used in further studies for objective decision-making about additional stabilization systems after microdiscectomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photopolymerized hydrogels are commonly used for a broad range of biomedical applications. As long as the polymer volume is accessible, gels can easily be hardened using light illumination. However, in clinics, especially for minimally invasive surgery, it becomes highly challenging to control photopolymerization. The ratios between polymerization- volume and radiating-surface-area are several orders of magnitude higher than for ex-vivo settings. Also tissue scattering occurs and influences the reaction. We developed a Monte Carlo model for photopolymerization, which takes into account the solid/liquid phase changes, moving solid/liquid-boundaries and refraction on these boundaries as well as tissue scattering in arbitrarily designable tissue cavities. The model provides a tool to tailor both the light probe and the scattering/absorption properties of the photopolymer for applications such as medical implants or tissue replacements. Based on the simulations, we have previously shown that by adding scattering additives to the liquid monomer, the photopolymerized volume was considerably increased. In this study, we have used bovine intervertebral disc cavities, as a model for spinal degeneration, to study photopolymerization in-vitro. The cavity is created by enzyme digestion. Using a custom designed probe, hydrogels were injected and photopolymerized. Magnetic resonance imaging (MRI) and visual inspection tools were employed to investigate the successful photopolymerization outcomes. The results provide insights for the development of novel endoscopic light-scattering polymerization probes paving the way for a new generation of implantable hydrogels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major component of minimally invasive cochlear implantation is atraumatic scala tympani (ST) placement of the electrode array. This work reports on a semiautomatic planning paradigm that uses anatomical landmarks and cochlear surface models for cochleostomy target and insertion trajectory computation. The method was validated in a human whole head cadaver model (n = 10 ears). Cochleostomy targets were generated from an automated script and used for consecutive planning of a direct cochlear access (DCA) drill trajectory from the mastoid surface to the inner ear. An image-guided robotic system was used to perform both, DCA and cochleostomy drilling. Nine of 10 implanted specimens showed complete ST placement. One case of scala vestibuli insertion occurred due to a registration/drilling error of 0.79 mm. The presented approach indicates that a safe cochleostomy target and insertion trajectory can be planned using conventional clinical imaging modalities, which lack sufficient resolution to identify the basilar membrane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robotic assistance in the context of lateral skull base surgery, particularly during cochlear implantation procedures, has been the subject of considerable research over the last decade. The use of robotics during these procedures has the potential to provide significant benefits to the patient by reducing invasiveness when gaining access to the cochlea, as well as reducing intracochlear trauma when performing a cochleostomy. Presented herein is preliminary work on the combination of two robotic systems for reducing invasiveness and trauma in cochlear implantation procedures. A robotic system for minimally invasive inner ear access was combined with a smart drilling tool for robust and safe cochleostomy; evaluation was completed on a single human cadaver specimen. Access to the middle ear was successfully achieved through the facial recess without damage to surrounding anatomical structures; cochleostomy was completed at the planned position with the endosteum remaining intact after drilling as confirmed by microscope evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Disenclavation is a common complication of prepupillary iris-claw intraocular lenses (IOL). We present a new minimally invasive revision surgery technique for reenclavation of prepupillary iris-claw IOLs using standard 23 Gauge (G) vitrectomy instruments. HISTORY AND SIGNS Three cases of revision surgery by unilaterally dislocated prepupillary iris-claw IOLs are presented. THERAPY AND OUTCOME Two 20 G sideports 90 degrees apart were constructed. Healon 10® was injected to maintain the anterior chamber. A standard enclavation needle was introduced to rotate the optic into correct position and a 23 G endgrasping forceps was used to grasp and stabilize the IOL for enclavation. The reenclavation was successful in all three cases and the mean visual acuity improved from preoperatively 0.1 (range counting fingers [CF] to 0.25) to 0.6 (range 0.4 to 0.8) with no significant induction of astigmatism. CONCLUSIONS This minimally invasive reenclavation technique for repositioning of the prepupillary iris claw IOL appears to lead to successful and rapid visual rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate substance loss and bond strength capacity of sclerotic, non-carious cervical dentin after airborne-particle abrasion or diamond bur preparation. Methods: Fifteen non-sclerotic dentin specimens were made from crowns of extracted human incisors of which the labial surfaces had been ground with silicon carbide papers (non-sclerotic control; Group 1). Forty-five sclerotic dentin specimens (n=15/group) were made from the labial, non-carious cervical root part of extracted human incisors and underwent either no pre-treatment (sclerotic control; Group 2), pre-treatment with airborne-particle abrasion (CoJet Prep [3M ESPE] and 50 µm aluminium oxide; Group 3), or with diamond bur preparation (40 µm grit size; Group 4). Substance loss after pre-treatment was measured in Groups 3 and 4. Subsequently, Scotchbond Universal (3M ESPE) and resin composite (CeramX [DENTSPLY DeTrey]) were applied on the treated dentin surfaces. The specimens were stored at 37°C and 100% humidity for 24 h. After storage, shear bond strength (SBS) was measured and data analyzed with nonparametric ANOVA followed by Wilcoxon rank sum tests. Results: Substance loss (medians) was 19 µm in Group 3 and 113 µm in Group 4. SBS-values (MPa; medians) in Group 2 (9.24) were significantly lower than in Group 1 (13.15; p=0.0069), Group 3 (13.05; p=0.01), and Group 4 (13.02; p=0.0142). There were no significant differences in SBS between Groups 1, 3, and 4 (p≥0.8063). Conclusion: Airborne-particle abrasion and diamond bur preparation restored bond strength of Scotchbond Universal to sclerotic dentin to the level of non-sclerotic dentin, with airborne-particle abrasion being less invasive than diamond bur preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical robots have been proposed ex vivo to drill precise holes in the temporal bone for minimally invasive cochlear implantation. The main risk of the procedure is damage of the facial nerve due to mechanical interaction or due to temperature elevation during the drilling process. To evaluate the thermal risk of the drilling process, a simplified model is proposed which aims to enable an assessment of risk posed to the facial nerve for a given set of constant process parameters for different mastoid bone densities. The model uses the bone density distribution along the drilling trajectory in the mastoid bone to calculate a time dependent heat production function at the tip of the drill bit. Using a time dependent moving point source Green's function, the heat equation can be solved at a certain point in space so that the resulting temperatures can be calculated over time. The model was calibrated and initially verified with in vivo temperature data. The data was collected in minimally invasive robotic drilling of 12 holes in four different sheep. The sheep were anesthetized and the temperature elevations were measured with a thermocouple which was inserted in a previously drilled hole next to the planned drilling trajectory. Bone density distributions were extracted from pre-operative CT data by averaging Hounsfield values over the drill bit diameter. Post-operative [Formula: see text]CT data was used to verify the drilling accuracy of the trajectories. The comparison of measured and calculated temperatures shows a very good match for both heating and cooling phases. The average prediction error of the maximum temperature was less than 0.7 °C and the average root mean square error was approximately 0.5 °C. To analyze potential thermal damage, the model was used to calculate temperature profiles and cumulative equivalent minutes at 43 °C at a minimal distance to the facial nerve. For the selected drilling parameters, temperature elevation profiles and cumulative equivalent minutes suggest that thermal elevation of this minimally invasive cochlear implantation surgery may pose a risk to the facial nerve, especially in sclerotic or high density mastoid bones. Optimized drilling parameters need to be evaluated and the model could be used for future risk evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem investigation is increasingly supported by Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). This led to the idea to implement a noninvasive or minimally invasive autopsy technique. Therefore, a minimally invasive angiography technique becomes necessary, in order to support the vascular cross section diagnostic. Preliminary experiments investigating different contrast agents for CT and MRI and their postmortem applicability have been performed using an ex-vivo porcine coronary model. MSCT and MRI angiography was performed in the porcine model. Three human corpses were investigated using minimally invasive MSCT angiography. Via the right femoral artery a plastic tube was advanced into the aortic arch. Using a flow adjustable pump the radiopaque contrast agent meglumine-ioxithalamate was injected. Subsequent MSCT scanning provided an excellent anatomic visualization of the human arterial system including intracranial and coronary arteries. Vascular pathologies such as calcification, stenosis and injury were detected. Limitations of the introduced approach are cases of major vessel injury and cases that show an advanced stage of decay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY QUESTION: What is the effect of the minimally invasive surgical treatment of endometriosis on health and on quality of work life (e.g. working performance) of affected women? SUMMARY ANSWER: Absence from work, performance loss and the general negative impact of endometriosis on the job are reduced significantly by the laparoscopic surgery. WHAT IS KNOWN ALREADY: The benefits of surgery overall and of the laparoscopic method in particular for treating endometriosis have been described before. However, previous studies focus on medical benchmarks without including the patient's perspective in a quantitative manner. STUDY DESIGN, SIZE, DURATION: A retrospective questionnaire-based survey covering 211 women with endometriosis and a history of specific laparoscopic surgery in a Swiss university hospital, tertiary care center. Data were returned anonymously and were collected from the beginning of 2012 until March 2013. PARTICIPANTS/MATERIALS, SETTING, METHODS: Women diagnosed with endometriosis and with at least one specific laparoscopic surgery in the past were enrolled in the study. The study investigated the effect of the minimally invasive surgery on health and on quality of work life of affected women. Questions used were obtained from the World Endometriosis Research Foundation (WERF) Global Study on Women's Health (GSWH) instrument. The questionnaire was shortened and adapted for the purpose of the present study. MAIN RESULTS AND THE ROLE OF CHANCE: Of the 587 women invited to participate in the study, 232 (232/587 = 40%) returned the questionnaires. Twenty-one questionnaires were excluded due to incomplete data and 211 sets (211/587 = 36%) were included in the study. Our data show that 62% (n = 130) of the study population declared endometriosis as influencing the job during the period prior to surgery, compared with 28% after surgery (P < 0.001). The mean (maximal) absence from work due to endometriosis was reduced from 2.0 (4.9) to 0.5 (1.4) hours per week (P < 0.001). The mean (maximal) loss in working performance after the surgery averaged out at 5.7% (12.6%) compared with 17.5% (30.5%) before this treatment (P < 0.001). LIMITATIONS, REASONS FOR CAUTION: The mediocre response rate of the study weakens the representativeness of the investigated population. Considering the anonymous setting a non-responder investigation was not performed. A bias due to selection, information and negativity effects within a retrospective survey cannot be excluded, although study-sensitive questions were provided in multiple ways. The absence of a control group (sham group; e.g. patients undergoing specific diagnostic laparoscopy without treatment) is a further limitation of the study. WIDER IMPLICATIONS OF THE FINDINGS: Our study shows that indicated minimally invasive surgery has a clear positive effect on the wellbeing and working performance of women suffering from moderate to severe endometriosis. Furthermore, national net savings in indirect costs with the present number of surgeries is estimated to be €10.7 million per year. In an idealized setting (i.e. without any diagnosis delay) this figure could be more than doubled. STUDY FUNDING/COMPETING INTERESTS: The study was performed on behalf of the University Hospital of Bern (Inselspital) as one of the leading Swiss tertiary care centers. The authors do not declare any competing interests.