34 resultados para inulin clearance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Lung clearance index (LCI), a marker of ventilation inhomogeneity, is elevated early in children with cystic fibrosis (CF). However, in infants with CF, LCI values are found to be normal, although structural lung abnormalities are often detectable. We hypothesized that this discrepancy is due to inadequate algorithms of the available software package. AIM Our aim was to challenge the validity of these software algorithms. METHODS We compared multiple breath washout (MBW) results of current software algorithms (automatic modus) to refined algorithms (manual modus) in 17 asymptomatic infants with CF, and 24 matched healthy term-born infants. The main difference between these two analysis methods lies in the calculation of the molar mass differences that the system uses to define the completion of the measurement. RESULTS In infants with CF the refined manual modus revealed clearly elevated LCI above 9 in 8 out of 35 measurements (23%), all showing LCI values below 8.3 using the automatic modus (paired t-test comparing the means, P < 0.001). Healthy infants showed normal LCI values using both analysis methods (n = 47, paired t-test, P = 0.79). The most relevant reason for false normal LCI values in infants with CF using the automatic modus was the incorrect recognition of the end-of-test too early during the washout. CONCLUSION We recommend the use of the manual modus for the analysis of MBW outcomes in infants in order to obtain more accurate results. This will allow appropriate use of infant lung function results for clinical and scientific purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulmonary exacerbations are important clinical events for cystic fibrosis (CF) patients. Studies assessing the ability of the lung clearance index (LCI) to detect treatment response for pulmonary exacerbations have yielded heterogeneous results. Here, we conduct a retrospective analysis of pooled LCI data to assess treatment with intravenous antibiotics for pulmonary exacerbations and to understand factors explaining the heterogeneous response.A systematic literature search was performed to identify prospective observational studies. Factors predicting the relative change in LCI and spirometry were evaluated while adjusting for within-study clustering.Six previously reported studies and one unpublished study, which included 176 pulmonary exacerbations in both paediatric and adult patients, were included. Overall, LCI significantly decreased by 0.40 units (95% CI -0.60- -0.19, p=0.004) or 2.5% following treatment. The relative change in LCI was significantly correlated with the relative change in forced expiratory volume in 1 s (FEV1), but results were discordant in 42.5% of subjects (80 out of 188). Higher (worse) baseline LCI was associated with a greater improvement in LCI (slope: -0.9%, 95% CI -1.0- -0.4%).LCI response to therapy for pulmonary exacerbations is heterogeneous in CF patients; the overall effect size is small and results are often discordant with FEV1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Oesophageal clearance has been scarcely studied. AIMS Oesophageal clearance in endoscopy-negative heartburn was assessed to detect differences in bolus clearance time among patients sub-grouped according to impedance-pH findings. METHODS In 118 consecutive endoscopy-negative heartburn patients impedance-pH monitoring was performed off-therapy. Acid exposure time, number of refluxes, baseline impedance, post-reflux swallow-induced peristaltic wave index and both automated and manual bolus clearance time were calculated. Patients were sub-grouped into pH/impedance positive (abnormal acid exposure and/or number of refluxes) and pH/impedance negative (normal acid exposure and number of refluxes), the former further subdivided on the basis of abnormal/normal acid exposure time (pH+/-) and abnormal/normal number of refluxes (impedance+/-). RESULTS Poor correlation (r=0.35) between automated and manual bolus clearance time was found. Manual bolus clearance time progressively decreased from pH+/impedance+ (42.6s), pH+/impedance- (27.1s), pH-/impedance+ (17.8s) to pH-/impedance- (10.8s). There was an inverse correlation between manual bolus clearance time and both baseline impedance and post-reflux swallow-induced peristaltic wave index, and a direct correlation between manual bolus clearance and acid exposure time. A manual bolus clearance time value of 14.8s had an accuracy of 93% to differentiate pH/impedance positive from pH/impedance negative patients. CONCLUSIONS When manually measured, bolus clearance time reflects reflux severity, confirming the pathophysiological relevance of oesophageal clearance in reflux disease.