54 resultados para injection,


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate whether intravaginal application of seminal plasma at the time of follicle aspiration in IVF or intracytoplasmic sperm injection treatment cycles has the potential to increase pregnancy rate. To calculate the number of patients needed to achieve significance in a multicenter trial. DESIGN: Double-blind, placebo-controlled randomized pilot study. SETTING: University department of gynecological endocrinology and reproductive medicine. PATIENT(S): One hundred sixty-eight patients undergoing IVF or intracytoplasmic sperm injection treatment. INTERVENTION(S): Cryopreserved seminal plasma from the patient's partner or sodium chloride (placebo) was injected into the cervix and the posterior fornix of the vagina just after follicle aspiration. MAIN OUTCOME MEASURE(S): Clinical-pregnancy rate. RESULT(S): One hundred sixty-eight patients agreed to participate in the study. Participation was limited to one treatment cycle. Thirty-one patients (18%) were excluded from the study, mainly as a result of canceled embryo transfers. Seventy patients received placebo, and 67 received seminal plasma. The clinical-pregnancy rate was 25.7% (18/70) in the placebo group. The clinical-pregnancy rate in the seminal plasma group reached 37.3% (25/67), corresponding to a relative increase of 45%. CONCLUSION(S): Even though significance was not reached in this pilot study, the data suggest that seminal plasma has the potential to improve pregnancy rate. It is estimated that around 450 patients need to be recruited to reach significance in a multicenter study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: We documented the effects of intradetrusor injections of botulinum neurotoxin type A (Botox(R)) for refractory idiopathic detrusor overactivity so that prospective patients maybe properly informed about possible improvement in quality of life, the duration of interinjection intervals and the risk of clean intermittent self-catheterization. MATERIALS AND METHODS: A total of 81 consecutive patients with refractory idiopathic detrusor overactivity treated with intradetrusor injections of 200 U botulinum neurotoxin type A at 20 sites per injection course were evaluated in this prospective, nonrandomized, open label cohort study. The primary outcome was changes in quality of life, as assessed by the short form of the Urogenital Distress Inventory and the Incontinence Impact Questionnaire before and after treatment. Secondary outcomes were the interinjection interval and the need for clean intermittent self-catheterization. RESULTS: After intradetrusor botulinum neurotoxin type A injections there was significant improvement in quality of life, which was sustained after repeat injections. Mean Urogenital Distress Inventory and Incontinence Impact Questionnaire scores decreased from 56 to 26 and 59 to 21 after injection 1 in 81 patients, from 52 to 30 and 51 to 24 after injection 2 in 24, from 40 to 19 and 43 to 17 after injection 3 in 13, from 44 to 17 and 61 to 15 after injection 4 in 6 and from 51 to 17 and 63 to 14 after injection 5 in 4, respectively. The median interinjection interval was 15, 12, 14 and 13 months between injections 1 and 2, 2 and 3, 3 and 4, and 4 and 5, respectively. Considering a post-void residual urine of greater than 100 ml with lower urinary tract symptoms as the indication for clean intermittent self-catheterization, the overall clean intermittent self-catheterization rate after treatment was 43%. CONCLUSIONS: Intradetrusor botulinum neurotoxin type A injections for refractory idiopathic detrusor overactivity significantly improved quality of life. This effect was sustained after repeat injection. More than 2 of 5 patients with refractory idiopathic detrusor overactivity required clean intermittent self-catheterization after botulinum neurotoxin type A injections and all prospective patients should be informed about this.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to compare a standard peripheral end-hole angiocatheter with those modified with side holes or side slits using experimental optical techniques to qualitatively compare the contrast material exit jets and using numeric techniques to provide flow visualization and quantitative comparisons. MATERIALS AND METHODS: A Schlieren imaging system was used to visualize the angiocatheter exit jet fluid dynamics at two different flow rates. Catheters were modified by drilling through-and-through side holes or by cutting slits into the catheters. A commercial computational fluid dynamics package was used to calculate numeric results for various vessel diameters and catheter orientations. RESULTS: Experimental images showed that modifying standard peripheral IV angiocatheters with side holes or side slits qualitatively changed the overall flow field and caused the exiting jet to become less well defined. Numeric calculations showed that the addition of side holes or slits resulted in a 9-30% reduction of the velocity of contrast material exiting the end hole of the angiocatheter. With the catheter tip directed obliquely to the wall, the maximum wall shear stress was always highest for the unmodified catheter and was always lowest for the four-side-slit catheter. CONCLUSION: Modified angiocatheters may have the potential to reduce extravasation events in patients by reducing vessel wall shear stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare tunnelled scleral intravitreal injection with straight scleral intravitreal injection concerning short-term intraocular pressure (IOP) changes, occurrence and amount of vitreous reflux, and patient discomfort. METHODS: Sixty patients were randomly allocated to two groups (tunnelled intravitreal injection and straight intravitreal injection). IOP was measured before and directly (<1 minute) after the injection of 0.05 mL of an antivascular endothelial growth factor agent and then every 5 minutes until IOP was <30 mmHg. Occurrence and amount of vitreous reflux were recorded. Patient discomfort during injection was assessed with a Wong-Baker faces pain rating scale. RESULTS: IOP (mmHg +/- SD) increased significantly directly after injection to 35.97 +/- 8.13 (tunnelled intravitreal injection) and 30.19 +/- 12.14 (straight intravitreal injection). These pressure spikes differed significantly between both groups (P = 0.01, mean difference: -7.11). Five minutes after injection, there was no significant difference in IOP increase between the groups. All IOP measurements were <30 mmHg after 15 minutes. Occurrence and amount of vitreous reflux were significantly higher with straight intravitreal injection. There was no significant difference in Wong-Baker faces pain rating scale score between both groups. CONCLUSION: Tunnelled intravitreal injection seems to be the technique of choice for low-volume intravitreal injection (0.05 mL). There is neither a difference in patient discomfort nor a difference in IOP increase 5 minutes after injection between both groups. Significantly less vitreous reflux with tunnelled intravitreal injection should lead to less postinjectional drug loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Proximal diffusion of local anaesthetic solution after perineural anaesthesia may lead to the desensitisation of structures other than those intended. However, there is no evidence-based study demonstrating the potential distribution and diffusion of local anaesthetic solution after perineural analgesia in the distal limb. OBJECTIVE: To document the potential diffusion of local anaesthetic solution using a radiopaque contrast model and to evaluate the influence of walking compared with confinement in a stable after injection. METHODS: Radiopaque contrast medium was injected subcutaneously over one palmar nerve at the base of the proximal sesamoid bones in 6 nonlame mature horses. Horses were assigned randomly to stand still or walk after injection. Radiographs were obtained 0, 5, 10, 15, 20 and 30 min after injection and were analysed to determine the distribution and diffusion of the contrast medium. RESULTS: In 89% of injections an elongated pattern of the contrast medium was observed suggesting distribution along the neurovascular bundle. After 49% of injections a fine radiopaque line extended proximally from the contrast 'patch', and in 25% of injections a line extended distally. There was significant proximal and distal diffusion with time when sequential radiographs of each limb were compared. The greatest diffusion occurred in the first 10 min. Walking did not significantly influence the extent of either proximal or distal diffusion. CONCLUSIONS AND POTENTIAL RELEVANCE: Significant proximal diffusion occurs in the first 10 min after perineural injection in the distal aspect of the limb and should be considered when interpreting nerve blocks. Distribution of local anaesthetic solution outside the fascia surrounding the neurovascular bundle or in lymphatic vessels may explain delayed or decreased effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Intracoronary administration of autologous bone marrow-derived mononuclear cells (BM-MNC) may improve remodeling of the left ventricle (LV) after acute myocardial infarction. The optimal time point of administration of BM-MNC is still uncertain and has rarely been addressed prospectively in randomized clinical trials. METHODS AND RESULTS In a multicenter study, we randomized 200 patients with large, successfully reperfused ST-segment elevation myocardial infarction in a 1:1:1 pattern into an open-labeled control and 2 BM-MNC treatment groups. In the BM-MNC groups, cells were administered either early (i.e., 5 to 7 days) or late (i.e., 3 to 4 weeks) after acute myocardial infarction. Cardiac magnetic resonance imaging was performed at baseline and after 4 months. The primary end point was the change from baseline to 4 months in global LV ejection fraction between the 2 treatment groups and the control group. The absolute change in LV ejection fraction from baseline to 4 months was -0.4±8.8% (mean±SD; P=0.74 versus baseline) in the control group, 1.8±8.4% (P=0.12 versus baseline) in the early group, and 0.8±7.6% (P=0.45 versus baseline) in the late group. The treatment effect of BM-MNC as estimated by ANCOVA was 1.25 (95% confidence interval, -1.83 to 4.32; P=0.42) for the early therapy group and 0.55 (95% confidence interval, -2.61 to 3.71; P=0.73) for the late therapy group. CONCLUSIONS Among patients with ST-segment elevation myocardial infarction and LV dysfunction after successful reperfusion, intracoronary infusion of BM-MNC at either 5 to 7 days or 3 to 4 weeks after acute myocardial infarction did not improve LV function at 4-month follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The occurrence of gaseous pollutants in soils has stimulated many experimental activities, including forced ventilation in the field as well as laboratory transport experiments with gases. The dispersion coefficient in advective-dispersive gas phase transport is often dominated by molecular diffusion, which leads to a large overall dispersivity gamma. Under such conditions it is important to distinguish between flux and resident modes of solute injection and detection. The influence of the inlet type oil the macroscopic injection mode was tested in two series of column experiments with gases at different mean flow velocities nu. First we compared infinite resident and flux injections, and second, semi-infinite resident and flux injections. It is shown that the macroscopically apparent injection condition depends on the geometry of the inlet section. A reduction of the cross-sectional area of the inlet relative to that of the column is very effective in excluding the diffusive solute input, thus allowing us to use the solutions for a flux Injection also at rather low mean flow velocities nu. If the whole cross section of a column is exposed to a large reservoir like that of ambient air, a semi-infinite resident injection is established, which can be distinguished from a flux injection even at relatively high velocities nu, depending on the mechanical dispersivity of the porous medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultraviolet-ozone treatment is used as a standard surface cleaning procedure for removal of molecular organic contamination from analytical and sensing devices. Here, it is applied for injection-molded polymer microcantilevers before characterization and sensing experiments. This article examines the effects of the surface cleaning process using commercial equipment, in particular on the performance and mechanical properties of the cantilevers. It can be shown that the first chemical aging process essentially consist of the cross linking of the polymer chains together with a physical aging of the material. For longer exposure, the expected thermo-oxidative formation of carbonyl groups sets in and an exposure dependent chemical degradation can be detected. A process time of 20 min was found suitable as a trade-off between cleaning and stability

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding and controlling the structural anisotropies of injection-molded polymers is vital for designing products such as cantilever-based sensors. Such micro-cantilevers are considered as cost-effective alternatives to single-crystalline silicon-based sensors. In order to achieve similar sensing characteristics,structure and morphology have to be controlled by means of processing parameters including mold temperature and injection speed. Synchrotron radiation-based scanning small- (SAXS) and wide-angle x-ray scattering techniques were used to quantify crystallinity and anisotropy in polymer micro-cantilevers with micrometer resolution in real space. SAXS measurements confirmed the lamellar nature of the injection-molded semi-crystalline micro-cantilevers. The homogenous cantilever material exhibits a lamellar periodicity increasing with mold temperature but not with injection speed. We demonstrate that micro-cantilevers made of semi-crystalline polymers such as polyvinylidenefluoride, polyoxymethylene, and polypropylene show the expected strong degree of anisotropy along the injection direction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid molds enable the fabrication of polymeric parts with features of different length scales by injection molding. The resulting polymer microelements combine optical or biological functionalities with designed mechanical properties. Two applications are chosen for illustration of this concept: As a first example, microelements for optical communication via fiber-to-fiber coupling are manufactured by combining two molds to a small mold insert. Both molds are fabricated using lithography and electroplating. As a second example, microcantilevers (μCs) for chemical sensing are surface patterned using a modular mold composed of a laser-machined cavity defining the geometry of the μCs, and an opposite flat tool side which is covered by a patterned polymer foil. Injection molding results in an array of 35 μm-thick μCs with microscale surface topographies. In both cases, when the mold is assembled and closed, reliefs are transferred onto one surface of the molded element whose outlines are defined by the micromold cavity. The main advantage of these hybrid methods lies in the simple integration of optical surface structures and gratings onto the surface of microcomponents with different sizes and orientations. This allows for independent development of functional properties and combinations thereof.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to clarify the mechanism taking place in field-enhanced sample injection coupled to sweeping and micellar EKC (FESI-Sweep-MEKC), with the utilization of two acidic high-conductivity buffers (HCBs), phosphoric acid or sodium phosphate buffer, in view of maximizing sensitivity enhancements. Using cationic model compounds in acidic media, a chemometric approach and simulations with SIMUL5 were implemented. Experimental design first enabled to identify the significant factors and their potential interactions. Simulation demonstrates the formation of moving boundaries during sample injection, which originate at the initial sample/HCB and HCB/buffer discontinuities and gradually change the compositions of HCB and BGE. With sodium phosphate buffer, the HCB conductivity increased during the injection, leading to a more efficient preconcentration by staking (about 1.6 times) than with phosphoric acid alone, for which conductivity decreased during injection. For the same injection time at constant voltage, however, a lower amount of analytes was injected with sodium phosphate buffer than with phosphoric acid. Consequently sensitivity enhancements were lower for the whole FESI-Sweep-MEKC process. This is why, in order to maximize sensitivity enhancements, it is proposed to work with sodium phosphate buffer as HCB and to use constant current during sample injection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Threo-methylphenidate is a chiral psychostimulant drug widely prescribed to treat attention-deficit hyperactivity disorder in children and adolescents. An enantioselective CE-based assay with head-column field-amplified sample stacking for analysis of threo-methylphenidate enantiomers in liquid/liquid extracts of oral fluid is described. Analytes are electrokinetically injected across a short water plug placed at the capillary inlet and become stacked at the interface between plug and buffer. Enantiomeric separation occurs within a few minutes in a pH 3.0 phosphate/triethanolamine buffer containing 20 mg/mL (2-hydroxypropyl)-β-CD as chiral selector. The assay with six point multilevel internal calibration provides a linear response for each enantiomer in the 10-200 ng/mL concentration range, is simple, inexpensive, and reproducible, and has an LOQ of 5 ng/mL. It was applied to oral fluid patient samples that were collected up to 12 h after intake of an immediate release tablet and two different extended release formulations with racemic methylphenidate. Drug profiles could thereby be assessed in a stereoselective way. Almost no levorotary threo-methylphenidate enantiomer was detected after intake of the two extended release formulations, whereas this enantiomer was detected during the first 2.5 h after intake of the immediate release preparation. The noninvasive collection of oral fluid is an attractive alternative to plasma for the monitoring of methylphenidate exposure in the pediatric community.