Influence of high-conductivity buffer composition on field-enhanced sample injection coupled to sweeping in CE


Autoria(s): Anres, Philippe; Delaunay, Nathalie; Vial, Jérôme; Thormann, Wolfgang; Gareil, Pierre
Data(s)

01/02/2013

Resumo

The aim of this work was to clarify the mechanism taking place in field-enhanced sample injection coupled to sweeping and micellar EKC (FESI-Sweep-MEKC), with the utilization of two acidic high-conductivity buffers (HCBs), phosphoric acid or sodium phosphate buffer, in view of maximizing sensitivity enhancements. Using cationic model compounds in acidic media, a chemometric approach and simulations with SIMUL5 were implemented. Experimental design first enabled to identify the significant factors and their potential interactions. Simulation demonstrates the formation of moving boundaries during sample injection, which originate at the initial sample/HCB and HCB/buffer discontinuities and gradually change the compositions of HCB and BGE. With sodium phosphate buffer, the HCB conductivity increased during the injection, leading to a more efficient preconcentration by staking (about 1.6 times) than with phosphoric acid alone, for which conductivity decreased during injection. For the same injection time at constant voltage, however, a lower amount of analytes was injected with sodium phosphate buffer than with phosphoric acid. Consequently sensitivity enhancements were lower for the whole FESI-Sweep-MEKC process. This is why, in order to maximize sensitivity enhancements, it is proposed to work with sodium phosphate buffer as HCB and to use constant current during sample injection.

Formato

application/pdf

Identificador

http://boris.unibe.ch/53973/1/wt226-philippe%20moving%20boundaries.pdf

Anres, Philippe; Delaunay, Nathalie; Vial, Jérôme; Thormann, Wolfgang; Gareil, Pierre (2013). Influence of high-conductivity buffer composition on field-enhanced sample injection coupled to sweeping in CE. Electrophoresis, 34(3), pp. 353-362. Wiley-VCH 10.1002/elps.201200374 <http://dx.doi.org/10.1002/elps.201200374>

doi:10.7892/boris.53973

info:doi:10.1002/elps.201200374

info:pmid:23161200

urn:issn:0173-0835

Idioma(s)

eng

Publicador

Wiley-VCH

Relação

http://boris.unibe.ch/53973/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Anres, Philippe; Delaunay, Nathalie; Vial, Jérôme; Thormann, Wolfgang; Gareil, Pierre (2013). Influence of high-conductivity buffer composition on field-enhanced sample injection coupled to sweeping in CE. Electrophoresis, 34(3), pp. 353-362. Wiley-VCH 10.1002/elps.201200374 <http://dx.doi.org/10.1002/elps.201200374>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed