36 resultados para distinctness of image
Resumo:
Background Image-guided systems have recently been introduced for their application in liver surgery.We aimed to identify and propose suitable indications for image-guided navigation systems in the domain of open oncologic liver surgery and,more specifically, in the setting of liver resection with and without microwave ablation. Method Retrospective analysis was conducted in patients undergoing liver resection with and without microwave ablation using an intraoperative image-guided stereotactic system during three stages of technological development (accuracy: 8.4 ± 4.4 mm in phase I and 8.4 ± 6.5 mm in phase II versus 4.5 ± 3.6 mm in phase III). It was evaluated, in which indications image-guided surgery was used according to the different stages of technical development. Results Between 2009 and 2013, 65 patients underwent image-guided surgical treatment, resection alone (n=38), ablation alone (n =11), or a combination thereof (n =16). With increasing accuracy of the system, image guidance was progressively used for atypical resections and combined microwave ablation and resection instead of formal liver resection (p<0.0001). Conclusion Clinical application of image guidance is feasible, while its efficacy is subject to accuracy. The concept of image guidance has been shown to be increasingly efficient for selected indications in liver surgery. While accuracy of available technology is increasing pertaining to technological advancements, more and more previously untreatable scenarios such as multiple small, bilobar lesions and so-called vanishing lesions come within reach.
Resumo:
We investigated the effect of image size on saccade amplitudes. First, in a meta-analysis, relevant results from previous scene perception studies are summarised, suggesting the possibility of a linear relationship between mean saccade amplitude and image size. Forty-eight observers viewed 96 colour scene images scaled to four different sizes, while their eye movements were recorded. Mean and median saccade amplitudes were found to be directly proportional to image size, while the mode of the distribution lay in the range of very short saccades. However, saccade amplitudes expressed as percentages of image size were not constant over the different image sizes; on smaller stimulus images, the relative saccades were found to be larger, and vice versa. In sum, and as far as mean and median saccade amplitudes are concerned, the size of stimulus images is the dominant factor. Other factors, such as image properties, viewing task, or measurement equipment, are only of subordinate importance. Thus, the role of stimulus size has to be reconsidered, in theoretical as well as methodological terms.
Resumo:
PURPOSE: The aim of this study was to evaluate ECG-gated whole chest CTA as a routine triage tool for patients with acute chest pain. MATERIAL AND METHODS: Whole chest CTA with retrospective ECG-gating was performed in 30 patients with acute atypical chest pain. The ten main segments of the coronary arteries, the pulmonary arteries, the aorta, and the myocardium (function, morphology) were independently analyzed by a resident and two senior radiologists. The inter-observer agreement between resident and senior radiologists was calculated. A final diagnosis was determined by consensus. RESULTS: Thirty patients were included. The coronary artery segments, myocardium and pulmonary arteries were considered analyzable in 84%, 90% and 97% of cases respectively. A final diagnosis for the cause of pain was retained in 19 patients: significant coronary artery stenosis (5), pulmonary embolus (5), aortic dissection (1), hypokinetic cardiomyopathy (2), lung parenchymal abnormalities (5), and hiatus hernia (1). Inter-observer agreement ranged from 0.76 to 1 between senior radiologists and from 0.76 to 1 between resident and senior radiologists. The average time of image interpretation ranged from 14 to 15 minutes. CONCLUSION: ECG-gated whole chest CT angiography appears as a promising tool for the evaluation of acute chest pain. Combined evaluation of appearance and function of the myocardium can reveal additional interesting information.
Resumo:
PURPOSE Positron emission tomography (PET)∕computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET∕CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET∕CT in the context of multicenter trials. METHODS To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET∕CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET∕CT systems, a dedicated solid-state phantom incorporating (68)Ge∕(68)Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET∕CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. RESULTS The proposed Transconvolution method matched different PET∕CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. CONCLUSIONS By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.
Resumo:
A Hennessy-Milner property, relating modal equivalence and bisimulations, is defined for many-valued modal logics that combine a local semantics based on a complete MTL-chain (a linearly ordered commutative integral residuated lattice) with crisp Kripke frames. A necessary and sufficient algebraic condition is then provided for the class of image-finite models of these logics to admit the Hennessy-Milner property. Complete characterizations are obtained in the case of many-valued modal logics based on BL-chains (divisible MTL-chains) that are finite or have universe [0,1], including crisp Lukasiewicz, Gödel, and product modal logics.
Resumo:
In this paper we propose a new fully-automatic method for localizing and segmenting 3D intervertebral discs from MR images, where the two problems are solved in a unified data-driven regression and classification framework. We estimate the output (image displacements for localization, or fg/bg labels for segmentation) of image points by exploiting both training data and geometric constraints simultaneously. The problem is formulated in a unified objective function which is then solved globally and efficiently. We validate our method on MR images of 25 patients. Taking manually labeled data as the ground truth, our method achieves a mean localization error of 1.3 mm, a mean Dice metric of 87%, and a mean surface distance of 1.3 mm. Our method can be applied to other localization and segmentation tasks.