85 resultados para correlation coefficient


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the study was to conduct a long-term follow-up on the stability of the hard tissues after bilateral sagittal split osteotomy (BSSO) with rigid internal fixation (RIF)to set back the mandible and to compare it with that of mandibular advancement performed by the same team of surgeons and with the same examination protocol. Seventeen consecutive patients (6 females and 11 males) could be re-examined 12.7 years (T5) after surgery. The previous examinations were before surgery (T1), 5 days (T2), and 6.6 (T3) and 14.4 (T4) months after surgery. Lateral cephalograms were traced by hand, digitized, and evaluated with the Dentofacial Planner software program. The x-axis for the system of co-ordinates ran through sella (point zero) and the line nasion-sella-line minus 7 degrees. The program determined the x- and y-values of each variable and the usual angles and distances. The effects of treatment were determined with Wilcoxon matched pairs, signed ranks test, with Bonferroni adjustment, and the relationship between variables with Spearman rank correlation coefficient. Relapse at point B was 0.94 mm or 15 per cent and at pogonion 1.46 mm or 21 per cent of the initial setback at T5. Relapse was mainly short-term (T4-T2), 13 per cent for point B and 17 per cent for pogonion. Gender correlated significantly with relapse (T5-T2) at point B (P = 0.002) and pogonion (P = 0.021), i.e. females in contrast to males showed further distalization of the mandible instead of relapse. No correlations were seen for age or the amount of surgical setback. The long-term results in mandibular setback patients were more stable when compared with the mandibular advancement patients examined previously. The initial soft tissue profile, the initial growth direction, and the remodelling processes of the hard tissues must be considered as reasons for long-term relapse. Growth direction positively influenced the long-term results in females: further distalization of the mandible occurred.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The delayed Gadolinium Enhanced MRI of Cartilage (dGEMRIC) technique has shown promising results in pilot clinical studies of early osteoarthritis. Currently, its broader acceptance is limited by the long scan time and the need for postprocessing to calculate the T1 maps. A fast T1 mapping imaging technique based on two spoiled gradient echo images was implemented. In phantom studies, an appropriate flip angle combination optimized for center T1 of 756 to 955 ms yielded excellent agreement with T1 measured using the inversion recovery technique in the range of 200 to 900 ms, of interest in normal and diseased cartilage. In vivo validation was performed by serially imaging 26 hips using the inversion recovery and the Fast 2 angle T1 mapping techniques (center T1 756 ms). Excellent correlation with Pearson correlation coefficient R2 of 0.74 was seen and Bland-Altman plots demonstrated no systematic bias.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Physical fitness can be evaluated in competitive and school sports with different field tests under different conditions and goals. To produce valid results, a field test must be practical and reach high standards of test criteria (objectivity, reliability, validity). The purpose of this study was to investigate the test criteria and the practicability of a group of field tests called «SUISSE Sport Test Konzept Basis Feldtestbatterie». For 20-m sprint, ventral trunk muscle test, standing long jump, 2-kg medicine ball shot, obstacle course and cooper-test, test quality and practicability were evaluated. 221 children and adolescents from competitive sports and different school levels took part in the study. According to school level, they were divided into 3 groups (P: 7–11.5 y, S1: 11.6–15.5 y, S2: 15.6–21.8 y). Objectivity was tested for time or distance measurement in all tests as well as for error rating in obstacle test. For reliability measurement, 162 subjects performed the field tests twice within a few weeks. For validity results of standing long jump were compared with counter movement jump performance on a force plate. Correlation analysis was performed and level of significance was set for p < 0.05. For accuracy standard error was calculated. All tests achieved sufficient to excellent objectiv - ity with correlation-coefficient (r) lying between 0.85 and 0.99. Reliability was very good (r = 0.84–0.97). In cooper- and trunk test, reliability was higher for athletes than for pupils (trunk test: r = 0.95 vs. r = 0.62, cooper-test: r = 0.90 vs. r = 0.78). In those tests the reliability decreases with increasing age (cooper-test: P: r = 0.84, S1: r = 0.69, S2: r = 0.52; trunk-test: P: r = 0.69, S1: r = 0.71; S2: r = 0.39). Validity for standing long jump was good (r = 0.75–0.86). The standard error of the mean was between 4–8%, with the exception for cooper-test (athletes: 6%, pupils: 11%) and trunk test (athletes: 14%, pupils: 46%). The results show that the evaluated group of field tests is a practicable, objective and reliable tool to determine physical skills in young athletes as well as in a scholar setting over a broad age range. Most of the tests achieved the test criteria with the grades good to excellent. The lower coefficient of reliability for cooper- and trunk test by the pupils could be explained by motivational problems in this setting. For up to 20 subjects, a tester can accomplish the tests within 3 h. Finally, age-dependent grades were elaborated

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To compare the performance of dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in measuring intraocular pressure in eyes with irregular corneas. METHODS: GAT and DCT measures were taken in 30 keratoconus and 29 postkeratoplasty eyes of 35 patients after pachymetry and corneal topography. Regression and correlation analyses were performed between both tonometry methods and between tonometry methods and corneal parameters. Bland-Altman plots were constructed. RESULTS: DCT values were significantly higher than GAT values in both study groups: +4.1 +/- 2.3 mm Hg (mean +/- SD) in keratoconus and +3.1 +/- 2.5 mm Hg after keratoplasty. In contrast to DCT, GAT values were significantly higher in postkeratoplasty eyes than in keratoconus. The correlation between the 2 tonometry methods was moderate in keratoconus (Kendall correlation coefficient, tau = 0.34) as well in postkeratoplasty eyes (tau = 0.66). The +/-1.96 SD span of the DCT-GAT differences showed a considerable range: -0.42 to +8.70 mm Hg in keratoconus and -1.87 to +7.98 mm Hg in postkeratoplasty eyes. In the keratoconus group, neither DCT nor GAT correlated significantly with any of the corneal parameters. In the postkeratoplasty group, both DCT and GAT measures showed a moderate positive correlation with corneal steepness, but only DCT had a significant negative correlation with the central corneal thickness (tau = -0.33). CONCLUSIONS: DCT measured significantly higher intraocular pressures than GAT in keratoconus and postkeratoplasty eyes. DCT and GAT measures varied considerably, and DCT was not less dependent on biomechanical properties of irregular corneas than GAT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Little is known about the population's exposure to radio frequency electromagnetic fields (RF-EMF) in industrialized countries. OBJECTIVES: To examine levels of exposure and the importance of different RF-EMF sources and settings in a sample of volunteers living in a Swiss city. METHODS: RF-EMF exposure of 166 volunteers from Basel, Switzerland, was measured with personal exposure meters (exposimeters). Participants carried an exposimeter for 1 week (two separate weeks in 32 participants) and completed an activity diary. Mean values were calculated using the robust regression on order statistics (ROS) method. RESULTS: Mean weekly exposure to all RF-EMF sources was 0.13 mW/m(2) (0.22 V/m) (range of individual means 0.014-0.881 mW/m(2)). Exposure was mainly due to mobile phone base stations (32.0%), mobile phone handsets (29.1%) and digital enhanced cordless telecommunications (DECT) phones (22.7%). Persons owning a DECT phone (total mean 0.15 mW/m(2)) or mobile phone (0.14 mW/m(2)) were exposed more than those not owning a DECT or mobile phone (0.10 mW/m(2)). Mean values were highest in trains (1.16 mW/m(2)), airports (0.74 mW/m(2)) and tramways or buses (0.36 mW/m(2)), and higher during daytime (0.16 mW/m(2)) than nighttime (0.08 mW/m(2)). The Spearman correlation coefficient between mean exposure in the first and second week was 0.61. CONCLUSIONS: Exposure to RF-EMF varied considerably between persons and locations but was fairly consistent within persons. Mobile phone handsets, mobile phone base stations and cordless phones were important sources of exposure in urban Switzerland.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: Cartilage defects are common pathologies and surgical cartilage repair shows promising results. In its postoperative evaluation, the magnetic resonance observation of cartilage repair tissue (MOCART) score, using different variables to describe the constitution of the cartilage repair tissue and the surrounding structures, is widely used. High-field magnetic resonance imaging (MRI) and 3-dimensional (3D) isotropic sequences may combine ideal preconditions to enhance the diagnostic performance of cartilage imaging.Aim of this study was to introduce an improved 3D MOCART score using the possibilities of an isotropic 3D true fast imaging with steady-state precession (True-FISP) sequence in the postoperative evaluation of patients after matrix-associated autologous chondrocyte transplantation (MACT) as well as to compare the results to the conventional 2D MOCART score using standard MR sequences. MATERIAL AND METHODS: The study had approval by the local ethics commission. One hundred consecutive MR scans in 60 patients at standard follow-up intervals of 1, 3, 6, 12, 24, and 60 months after MACT of the knee joint were prospectively included. The mean follow-up interval of this cross-sectional evaluation was 21.4 +/- 20.6 months; the mean age of the patients was 35.8 +/- 9.4 years. MRI was performed at a 3.0 Tesla unit. All variables of the standard 2D MOCART score where part of the new 3D MOCART score. Furthermore, additional variables and options were included with the aims to use the capabilities of isotropic MRI, to include the results of recent studies, and to adapt to the needs of patients and physician in a clinical routine examination. A proton-density turbo spin-echo sequence, a T2-weighted dual fast spin-echo (dual-FSE) sequence, and a T1-weighted turbo inversion recovery magnitude (TIRM) sequence were used to assess the standard 2D MOCART score; an isotropic 3D-TrueFISP sequence was prepared to evaluate the new 3D MOCART score. All 9 variables of the 2D MOCART score were compared with the corresponding variables obtained by the 3D MOCART score using the Pearson correlation coefficient; additionally the subjective quality and possible artifacts of the MR sequences were analyzed. RESULTS: The correlation between the standard 2D MOCART score and the new 3D MOCART showed for the 8 variables "defect fill," "cartilage interface," "surface," "adhesions," "structure," "signal intensity," "subchondral lamina," and "effusion"-a highly significant (P < 0.001) correlation with a Pearson coefficient between 0.566 and 0.932. The variable "bone marrow edema" correlated significantly (P < 0.05; Pearson coefficient: 0.257). The subjective quality of the 3 standard MR sequences was comparable to the isotropic 3D-TrueFISP sequence. Artifacts were more frequently visible within the 3D-TrueFISP sequence. CONCLUSION: In the clinical routine follow-up after cartilage repair, the 3D MOCART score, assessed by only 1 high-resolution isotropic MR sequence, provides comparable information than the standard 2D MOCART score. Hence, the new 3D MOCART score has the potential to combine the information of the standard 2D MOCART score with the possible advantages of isotropic 3D MRI at high-field. A clear limitation of the 3D-TrueFISP sequence was the high number of artifacts. Future studies have to prove the clinical benefits of a 3D MOCART score.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Recent studies have shown that a low clinical pretest probability may be adequate for excluding heparin-induced thrombocytopenia. However, for patients with intermediate or high pretest probability, laboratory testing is essential for confirming or refuting the diagnosis. Rapid assessment of anti-PF4/heparin-antibodies may assist clinical decision-making. OBJECTIVES: To evaluate the performance of rapid ID-H/PF4-PaGIA. In particular, we verified reproducibility of results between plasma and serum specimens, between fresh and frozen samples, and between different ID-H/PF4-polymer lots (polystyrene beads coated with heparin/PF4-complexes). PATIENTS/METHODS: The samples studied were 1376 plasma and 914 corresponding serum samples from patients investigated for suspected heparin-induced thrombocytopenia between January 2000 and October 2008. Anti-PF4/heparin-antibodies were assessed by ID-H/PF4-PaGIA, commercially available ELISAs and heparin-induced platelet aggregation test. RESULTS: Among 914 paired plasma/serum samples we noted discordant results (negative vs. low-titre positive) in nine instances (1%; 95%CI, 0.4-1.6%). Overall, agreement between titres assessed in plasma vs. serum was highly significant (Spearman correlation coefficient, 0.975; P < 0.0001). Forty-seven samples tested both fresh and after freezing/thawing showed a good agreement, with one discordant positive/negative result (Spearman correlation coefficient, 0.970; P < 0.0001). Among 1376 plasma samples we noted a strikingly variable incidence of false negative results (none - 82%; 95%CI, 66-98%), depending on the employed ID-H/PF4-polymer lot. Faulty lots can be recognized by titrating commercial positive controls and stored samples of HIT-patients. CONCLUSION: Laboratories performing the assay should implement stringent internal quality controls in order to recognize potentially faulty ID-H/PF4-polymer lots, thus avoiding false negative results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Sound epidemiologic data on halitosis are rare. We evaluated the prevalence of halitosis in a young male adult population in Switzerland using a standardized questionnaire and clinical examination. METHODS: Six hundred twenty-six Swiss Army recruits aged 18 to 25 years (mean: 20.3 years) were selected as study subjects. First, a standardized questionnaire focusing on dental hygiene, self-reported halitosis, smoking, and alcohol consumption was filled out by all participants. In the clinical examination, objective values for the presence of halitosis were gathered through an organoleptic assessment of the breath odor and the measurement of volatile sulfur compounds (VSCs). Additionally, tongue coating, plaque index, and probing depths were evaluated for each recruit. RESULTS: The questionnaire revealed that only 17% of all included recruits had never experienced halitosis. The organoleptic evaluation (grades 0 to 3) identified eight persons with grade 3, 148 persons with grade 2, and 424 persons with grade 1 or 0. The calculation of the Pearson correlation coefficient to evaluate the relationship among the three methods of assessing halitosis revealed little to no correlation. The organoleptic score showed high reproducibility (kappa = 0.79). Tongue coating was the only influencing factor found to contribute to higher organoleptic scores and higher VSC values. CONCLUSIONS: Oral malodor seemed to pose an oral health problem for about one-fifth of 20-year-old Swiss males questioned. No correlation between self-reported halitosis and organoleptic or VSC measurements could be detected. Although the organoleptic method described here offers a high reproducibility, the lack of correlation between VSC values and organoleptic scores has to be critically addressed. For further studies assessing new organoleptic scores, a validated index should always be included as a direct control.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND AIMS: The splanchnic circulation has an important function in the body under both physiological and pathophysiological conditions. Despite its importance, no reliable noninvasive procedures for estimating splanchnic circulation have been established. The aim of this study was to evaluate MRI as a tool for assessing intra-abdominal blood flows of the aorta, portal vein (VPO) and the major intestinal and hepatic vessels. METHODS: In nine healthy volunteers, the proximal aorta (AOP) and distal abdominal aorta (AOD), superior mesenteric artery (SAM), celiac trunk (CTR), hepatic arteries (common and proper hepatic arteries, AHC and AHP, respectively), and VPO were localized on contrast-enhanced magnetic resonance angiography images. Volumetric flow was measured using a two-dimensional cine echocardiogram-gated phase contrast technique. Measurements were taken before and 30 min after continuous intravenous infusion of somatostatin (250 microg/h) and were independently evaluated by two investigators. RESULTS: Blood flow measured by MRI in the VPO, SAM, AOP, AHP, and CTR significantly decreased after drug infusion. Flows in the AOD and AHC showed a tendency to decrease (P>0.05). Interrater agreement on flows in MRI was very good for large vessels (VPO, AOP, and AOD), with a concordance correlation coefficient of 0.94, as well as for smaller vessels such as the CTR, AHC, AHP, and SAM (concordance correlation coefficient =0.78). CONCLUSION: Somatostatin-induced blood flow changes in the splanchnic region were reliably detected by MRI. MRI may be useful for the noninvasive assessment of blood flow changes in the splanchnic region.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND The correlation between noninvasive markers with endoscopic activity according to the modified Baron Index in patients with ulcerative colitis (UC) is unknown. We aimed to evaluate the correlation between endoscopic activity and fecal calprotectin (FC), C-reactive protein (CRP), hemoglobin, platelets, blood leukocytes, and the Lichtiger Index (clinical score). METHODS UC patients undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically. Samples from feces and blood were analyzed in UC patients and controls. RESULTS We enrolled 228 UC patients and 52 healthy controls. Endoscopic disease activity correlated best with FC (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), platelets (r = 0.488), blood leukocytes (r = 0.401), and hemoglobin (r = -0.388). FC was the only marker that could discriminate between different grades of endoscopic activity (grade 0, 16 [10-30] μg/g; grade 1, 35 [25-48] μg/g; grade 2, 102 [44-159] μg/g; grade 3, 235 [176-319] μg/g; grade 4, 611 [406-868] μg/g; P < 0.001 for discriminating the different grades). FC with a cutoff of 57 μg/g had a sensitivity of 91% and a specificity of 90% to detect endoscopically active disease (modified Baron Index ≥ 2). CONCLUSIONS FC correlated better with endoscopic disease activity than clinical activity, CRP, platelets, hemoglobin, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to compare the right (RV) and left (LV) ventricular Tei indices obtained by pulsed-wave Doppler (PD) and tissue Doppler (TD) methods in fetuses with structurally normal and abnormal hearts. METHODS This was a retrospective cross-sectional study of 147 fetuses that had a fetal echocardiogram and Tei index measured during a 2-year period. The RV and LV Tei indices were measured using both PD and TD methods. The difference between the two methods of Tei index measurement was tested using paired sample t-test, Pearson correlation coefficient was used to examine their relationship, and the agreement between the methods was tested using Bland-Altman analysis. RESULTS A total of 87 fetuses had normal hearts and 60 had a congenital heart defect. Both PD and TD Tei indices were measured successfully from at least one ventricle in 123 cases and from both ventricles in 110 cases. The mean TD Tei index was significantly higher than the mean PD Tei index for both ventricles (P < 0.0001). There was a weak but statistically significant correlation between the PD and TD Tei indices of the right ventricle (r = 0.20, P = 0.029), whereas the PD and TD Tei indices of the left ventricle did not correlate significantly (r = 0.04, P = 0.684). When pairs of Tei indices measured by two different methods (123 pairs for the right ventricle and 111 for the left ventricle) were tested with Bland-Altman analysis, the bias and precision were 0.147 and 0.254, respectively, for the right ventricle, and 0.299 and 0.276, respectively, for the left ventricle. CONCLUSIONS Correlation between Tei indices measured by PD and TD methods is weak and the agreement between individual measurements is poor. Therefore, they should not be used interchangeably in the assessment of fetal cardiac function.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE Only limited data exists in terms of the incidence of intracranial bleeding (ICB) in patients with mild traumatic brain injury (MTBI). METHODS We retrospectively identified 3088 patients (mean age 41 range (7-99) years) presenting with isolated MTBI and GCS 14-15 at our Emergency Department who had undergone cranial CT (CCT) between 2002 and 2011. Indication for CCT was according to the "Canadian CT head rules." Patients with ICB were either submitted for neurosurgical treatment or kept under surveillance for at least 24 hours. Pearson's correlation coefficient was used to correlate the incidence of ICB with age, gender, or intake of coumarins, platelet aggregation inhibitors, or heparins. RESULTS 149 patients (4.8%) had ICB on CCT. No patient with ICB died or deteriorated neurologically. The incidence of ICB increased with age and intake of anticoagulants without clinically relevant correlation (R = 0.11; P < 0.001; R = -0.06; P < 0.001). CONCLUSION Our data show an incidence of 4.8% for ICB after MTBI. However, neurological deterioration after MTBI seems to be rare, and the need for neurosurgical intervention is only required in selected cases. The general need for CCT in patients after MTBI is therefore questionable, and clinical surveillance may be sufficient when CCT is not available.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE Well-developed collaterals provide survival benefit in patients with obstructive coronary artery disease (CAD). Therefore, in this study we sought to determine which clinical variables are associated with arteriogenesis. DESIGN Clinical and laboratory variables were collected before percutaneous coronary intervention. Multivariate analysis was performed to determine which variables are associated with the collateral flow index (CFI). PATIENTS Data from 295 chronic total occlusion (CTO) patients (Bern, Switzerland, Amsterdam, the Netherlands and Jena, Germany) were pooled. In earlier studies, patients had varying degrees of stenosis. Therefore, different stages of development of the collaterals were used. In our study, a unique group of patients with CTO was analysed. INTERVENTIONS Instead of angiography used earlier, we used a more accurate method to determine CFI using intracoronary pressure measurements. CFI was calculated from the occlusive pressure distal of the coronary lesion, the aortic pressure and central venous pressure. RESULTS The mean CFI was 0.39 ± 0.14. After multivariate analysis, β blockers, hypertension and angina pectoris duration were positively associated with CFI (B: correlation coefficient β=0.07, SE=0.03, p=0.02, B=0.040, SE=0.02, p=0.042 and B=0.001, SE=0.000, p=0.02). Furthermore also after multivariate analysis, high serum leucocytes, prior myocardial infarction and high diastolic blood pressure were negatively associated with CFI (B=-0.01, SE=0.005, p=0.03, B=-0.04, SE=0.02, p=0.03 and B=-0.002, SE=0.001, p=0.011). CONCLUSIONS In this unique cohort, high serum leucocytes and high diastolic blood pressure are associated with poorly developed collaterals. Interestingly, the use of β blockers is associated with well-developed collaterals, shedding new light on the potential action mode of this drug in patients with CAD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PRINCIPLES To evaluate the validity and feasibility of a novel photography-based home assessment (PhoHA) protocol, as a possible substitute for on-site home assessment (OsHA). METHODS A total of 20 patients aged ≥65 years who were hospitalised in a rehabilitation centre for musculoskeletal disorders affecting mobility participated in this prospective validation study. For PhoHA, occupational therapists rated photographs and measurements of patients' homes provided by patients' confidants. For OsHA, occupational therapists conducted a conventional home visit. RESULTS Information obtained by PhoHA was 79.1% complete (1,120 environmental factors identified by PhoHA vs 1416 by OsHA). Of the 1,120 factors, 749 had dichotomous (potential hazards) and 371 continuous scores (measurements with tape measure). Validity of PhoHA to potential hazards was good (sensitivity 78.9%, specificity 84.9%), except for two subdomains (pathways, slippery surfaces). Pearson's correlation coefficient for the validity of measurements was 0.87 (95% confidence interval [CI 0.80-0.92, p <0.001). Agreement between methods was 0.52 (95%CI 0.34-0.67, p <0.001, Cohen's kappa coefficient) for dichotomous and 0.86 (95%CI 0.79-0.91, p <0.001, intraclass correlation coefficient) for continuous scores. Costs of PhoHA were 53.0% lower than those of OsHA (p <0.001). CONCLUSIONS PhoHA has good concurrent validity for environmental assessment if instructions for confidants are improved. PhoHA is potentially a cost-effective method for environmental assessment.