45 resultados para Standardization in robotics


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES To conduct a survey across European cardiac centres to evaluate the methods used for cerebral protection during aortic surgery involving the aortic arch. METHODS All European centres were contacted and surgeons were requested to fill out a short, comprehensive questionnaire on an internet-based platform. One-third of more than 400 contacted centres completed the survey correctly. RESULTS The most preferred site for arterial cannulation is the subclavian-axillary, both in acute and chronic presentation. The femoral artery is still frequently used in the acute condition, while the ascending aorta is a frequent second choice in the case of chronic presentation. Bilateral antegrade brain perfusion is chosen by the majority of centres (2/3 of cases), while retrograde perfusion or circulatory arrest is very seldom used and almost exclusively in acute clinical presentation. The same pumping system of the cardio pulmonary bypass is most of the time used for selective cerebral perfusion, and the perfusate temperature is usually maintained between 22 and 26°C. One-third of the centres use lower temperatures. Perfusate flow and pressure are fairly consistent among centres in the range of 10-15 ml/kg and 60 mmHg, respectively. In 60% of cases, barbiturates are added for cerebral protection, while visceral perfusion still receives little attention. Regarding cerebral monitoring, there is a general tendency to use near-infrared spectroscopy associated with bilateral radial pressure measurement. CONCLUSIONS These data represent a snapshot of the strategies used for cerebral protection during major aortic surgery in current practice, and may serve as a reference for standardization and refinement of different approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SP’s performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Methods SP trainers from all five Swiss medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised with the partners twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. Both, SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). FAIR_OSCE The list of items to assess the quality of the simulation by SPs was primarily developed and used to provide formative feedback to the SPs in order to help them to improve their performance. It was therefore named “Feedbackstruckture for the Assessment of Interactive Role play in Objective Structured Clinical Exams (FAIR_OSCE). It was also used to assess the quality of patient portrayal during the exam. The results were calculated for each of the five faculties individually. Formative evaluation was given to the five faculties with individual feedback without revealing results of other faculties other than overall results. Results High quality of patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. In example the rate of completely correct reaction in medical tests increased from 88% to 95%. 95% completely correct reactions together with 4% sufficient reactions add up to 99% of the reactions meeting the requirements of the exam. SP educators using the instrument reported an augmentation of SPs performance induced by the use of the instrument. Disadvantages mentioned were high concentration needed to explicitly observe all criteria and cumbersome handling of the paper-based forms. Conclusion We were able to document a very high quality of SP performance in our exam. The data also indicate that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed augmentation of performance. The development of an iPad based application for the form is planned to address the cumbersome handling of the paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SPs’ performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Project description SP trainers from five medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). Outcome High quality of SPs’ patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. For example, the rate of completely correct reaction in medical tests increased from 88% to 95%. Together with 4% of sufficient performances these 95% add up to 99% of the reactions in medical tests meeting the standards of the exam. SP educators using the instrument reported an augmentation of SPs’ performance induced by the use of the instrument. Disadvantages mentioned were the high concentration needed to observe all criteria and the cumbersome handling of the paper-based forms. Discussion We were able to document a very high quality of SP performance in our exam. The data also indicates that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed enhancement of performance. The development of an iPad-based application for the form is planned to address the cumbersome handling of the paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO2peak and HRpeak were assessed. Absolute VO2peak from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HRpeak from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO2peak and HRpeak from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO2peak and HRpeak for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within-subject standardization (ipsatization) has been advocated as a possible means to control for culture-specific responding (e.g., Fisher, 2004). However, the consequences of different kinds of ipsatization procedures for the interpretation of mean differences remain unclear. The current study compared several ipsatization procedures with ANCOVA-style procedures using response style indicators for the construct of family orientation with data from 14 cultures and two generations from the Value-of-Children-(VOC)-Study (4135 dyads). Results showed that within-subject centering/standardizing across all Likert-scale items of the comprehensive VOC-questionnaire removed most of the original cross-cultural variation in family orientation and lead to a non-interpretable pattern of means in both generations. Within-subject centering/standardizing using a subset of 19 unrelated items lead to a decrease to about half of the original effect size and produced a theoretically meaningful pattern of means. A similar effect size and similar mean differences were obtained when using a measure of acquiescent responding based on the same set of items in an ANCOVA-style analysis. Additional models controlling for extremity and modesty performed worse, and combinations did not differ from the acquiescence-only model. The usefulness of different approaches to control for uniform response styles (scalar equivalence not given) in cross- cultural comparisons is discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Zusammenfassung Hintergrund. Hämodialysepatienten, die operativ mit einem Gefäßzugang versorgt werden müssen, sind eine vulnerable Patientengruppe, die aufgrund von Multimorbidität, der intensiven und oft fragmentierten Behandlung und vieler Schnittstellen ein erhöhtes Risiko für vermeidbare unerwünschte Ereignisse tragen. Fragestellung. Aktuelle Entwicklungen und Maßnahmen zur Förderung der Patientensicherheit mit Fokus auf die Shuntchirurgie. Material und Methoden. Auswertung und Aufarbeitung aktueller Daten zur Patientensicherheit und Instrumenten zu ihrer Förderung. Ergebnisse. Fehler im nicht operativen Management verursachen einen wesentlichen Anteil der unerwünschten Ereignisse. Checklisten, präoperative Seitenmarkierung, Zählkontrollen und interprofessionelle Teamtrainings sind wichtige Instrumente der Patientensicherheit im OP. Standardisierungen von postoperativen Übergaben durch einfache Protokolle können erheblich zur Reduktion von Fehlern und Schädigungen beitragen. Die Sicherheitskultur einer Abteilung ist ein Umgebungsfaktor, der für die Effektivität dieser Sicherheitsbarrieren wesentlich ist. Schlussfolgerungen. Es existieren wirksame Instrumente, die die Patientensicherheit in der Shuntchirurgie fördern. Gerade an den Schnittstellen zur weiteren Versorgung können durch die konsequente Implementierung und Nutzung dieser Maßnahmen und ein aktives Sicherheitsmanagement unerwünschte Ereignisse vermieden werden. Die interprofessionelle und interdisziplinäre Zusammenarbeit und der Einbezug der Patienten sind wichtige Ressource für die Behandlungssicherheit, die stärker genutzt werden sollten.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neuroendocrine tumors (NET) are routinely graded and staged to judge prognosis. Proliferation index using MIB1 staining has been introduced to assess grading. There are vivid discussions on cutoff definitions, automated counting, and interobserver variability. However, no data exist regarding interlaboratory reproducibility for low proliferation indices which are of importance to discriminate between G1 and G2 NET. We performed MIB1 staining in three different university hospital-based pathology laboratories on a tissue micro array (TMA) of a well-characterized patient cohort, containing pancreatic NET of 61 patients. To calculate the proliferation index, number of positive tumor nuclei was divided by the total number of tumor nuclei. Labeling index was compared to mitotic counts in whole tissue sections and to clinical outcome. Linear regression analysis, intraclass comparison, and log-rank analysis were performed. Intraclass correlation showed moderate-to-fair agreement. Especially low proliferating tumors were affected by interlaboratory differences. Log-rank analysis was performed for each lab and resulted in three different cutoffs (5.0, 3.0, and 0.5 %). Every calculated cutoff stratified the patient cohort to a significant extent for the underlying stain (p < 0.001, <0.001, and <0.001) but showed no or lesser significance when applied to the other stains. Significant and relevant interlab differences for MIB1 exist. Since the MIB1 proliferation index influences grading, local cutoffs or external standardization should urgently be introduced to achieve reliability and reproducibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The robotics-assisted tilt table (RATT), including actuators for tilting and cyclical leg movement, is used for rehabilitation of severely disabled neurological patients. Following further engineering development of the system, i.e. the addition of force sensors and visual bio-feedback, patients can actively participate in exercise testing and training on the device. Peak cardiopulmonary performance parameters were previously investigated, but it also important to compare submaximal parameters with standard devices. The aim of this study was to evaluate the feasibility of the RATT for estimation of submaximal exercise thresholds by comparison with a cycle ergometer and a treadmill. METHODS: 17 healthy subjects randomly performed six maximal individualized incremental exercise tests, with two tests on each of the three exercise modalities. The ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) were determined from breath-by-breath data. RESULTS: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill: oxygen uptake (V'O2) at VAT was [mean (SD)] 1.2 (0.3), 1.5 (0.4) and 1.6 (0.5) L/min, respectively (p < 0.001); V'O2 at RCP was 1.7 (0.4), 2.3 (0.8) and 2.6 (0.9) L/min, respectively (p = 0.001). High correlations for VAT and RCP were found between the RATT vs the cycle ergometer and RATT vs the treadmill (R on the range 0.69-0.80). VAT and RCP demonstrated excellent test-retest reliability for all three devices (ICC from 0.81 to 0.98). Mean differences between the test and retest values on each device were close to zero. The ventilatory equivalent for O2 at VAT for the RATT and cycle ergometer were similar and both were higher than the treadmill. The ventilatory equivalent for CO2 at RCP was similar for all devices. Ventilatory equivalent parameters demonstrated fair-to-excellent reliability and repeatability. CONCLUSIONS: It is feasible to use the RATT for estimation of submaximal exercise thresholds: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill, but there were high correlations between the RATT vs the cycle ergometer and vs the treadmill. Repeatability and test-retest reliability of all submaximal threshold parameters from the RATT were comparable to those of standard devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Sensor-based recordings of human movements are becoming increasingly important for the assessment of motor symptoms in neurological disorders beyond rehabilitative purposes. ASSESS MS is a movement recording and analysis system being developed to automate the classification of motor dysfunction in patients with multiple sclerosis (MS) using depth-sensing computer vision. It aims to provide a more consistent and finer-grained measurement of motor dysfunction than currently possible. Objective: To test the usability and acceptability of ASSESS MS with health professionals and patients with MS. Methods: A prospective, mixed-methods study was carried out at 3 centers. After a 1-hour training session, a convenience sample of 12 health professionals (6 neurologists and 6 nurses) used ASSESS MS to capture recordings of standardized movements performed by 51 volunteer patients. Metrics for effectiveness, efficiency, and acceptability were defined and used to analyze data captured by ASSESS MS, video recordings of each examination, feedback questionnaires, and follow-up interviews. Results: All health professionals were able to complete recordings using ASSESS MS, achieving high levels of standardization on 3 of 4 metrics (movement performance, lateral positioning, and clear camera view but not distance positioning). Results were unaffected by patients’ level of physical or cognitive disability. ASSESS MS was perceived as easy to use by both patients and health professionals with high scores on the Likert-scale questions and positive interview commentary. ASSESS MS was highly acceptable to patients on all dimensions considered, including attitudes to future use, interaction (with health professionals), and overall perceptions of ASSESS MS. Health professionals also accepted ASSESS MS, but with greater ambivalence arising from the need to alter patient interaction styles. There was little variation in results across participating centers, and no differences between neurologists and nurses. Conclusions: In typical clinical settings, ASSESS MS is usable and acceptable to both patients and health professionals, generating data of a quality suitable for clinical analysis. An iterative design process appears to have been successful in accounting for factors that permit ASSESS MS to be used by a range of health professionals in new settings with minimal training. The study shows the potential of shifting ubiquitous sensing technologies from research into the clinic through a design approach that gives appropriate attention to the clinic environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To analyze the prevalence of urinary tract endometriosis (UTE) in patients with deep infiltrating endometriosis (DIE) and to define potential criteria for preoperative workup. DESIGN Retrospective study. SETTING University hospital. PATIENT(S) Six hundred ninety-seven patients with endometriosis. INTERVENTION(S) Excision of all endometriotic lesions. MAIN OUTCOME MEASURE(S) Correlation of preoperative features and intraoperative findings in patients with UTE. RESULT(S) Out of 213 patients presenting DIE, 52.6% suffered from UTE. In patients with ureteral endometriosis, symptoms were not specific. Among the patients with bladder endometriosis, 68.8% complained of urinary symptoms compared to 7.9% in the group of patients without UTE. In patients with rectovaginal endometriosis, the probability of ureterolysis showed a linear correlation with the size of the nodule. We found that 3 cm in diameter provided a specific cutoff value for the likelihood of ureteric involvement. CONCLUSION(S) The prevalence of UTE has often been underestimated. Preoperative questioning is important in the search for bladder endometriosis. The size of the nodule is one of the few reliable criteria in preoperative assessment that can suggest ureteric involvement. We propose a classification of ureteral endometriosis that will allow the standardization of terminology and help to compare the outcome of different surgical treatment in randomized studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Workshop Overview The use of special effects (moulage) is a way to augment the authenticity of a scenario in simulation. This workshop will introduce different techniques of moulage (oil based cream colors, watercolors, transfer tattoos and 3D Prosthetics). The participants will have the opportunity to explore these techniques by applying various moulages. They will compare the techniques and discuss their advantages and disadvantages. Moreover, strategies for standardization and quality assurance will be discussed. Workshop Rationale Moulage supports the sensory perception in an scenario (1). It can provide evaluation clues (2) and help learners (and SPs) to engage in the simulation. However, it is of crucial importance that the simulated physical pathologies are represented accurate and reliable. Accuracy is achieved by using the appropriate technique, which requires knowledge and practice . With information about different moulage techniques, we hope to increases the knowledge of moulage during the workshop. By applying moulages in various techniques we will practice together. As standardization is critical for simulation scenarios in assessment (3, 4) strategies for standardization of moulage will be introduced and discussed. Workshop Objectives During the workshop participants will: - gain knowledge about different techniques of moulages - practice moulages in various techniques - discuss the advantages and disadvantages of moulage techniques - describe strategies for standardization and quality assurance of moulage Planned Format 5 min Introduction 15 min Overview – Background & Theory (presentation) 15 min Application of moulage for ankle sprain in 4 different techniques (oil based cream color, water color, temporary tatoo, 3D prosthetic) in small groups 5 min Comparing the results by interactive viewing of prepared moulages 15 min Application of moulages for burn in different techniques in small groups 5 min Comparing results the results by interactive viewing of prepared moulages 5 min Sharing experiences with different techniques in small groups 20 min Discussion of the techniques including standardization and quality assurance strategies (plenary discussion) 5 min Summary / Take home points

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pregnant BALB/c mice have been widely used as an in vivo model to study Neospora caninum infection biology and to provide proof-of-concept for assessments of drugs and vaccines against neosporosis. The fact that this model has been used with different isolates of variable virulence, varying infection routes and differing methods to prepare the parasites for infection, has rendered the comparison of results from different laboratories impossible. In most studies, mice were infected with similar number of parasites (2 × 10(6)) as employed in ruminant models (10(7) for cows and 10(6) for sheep), which seems inappropriate considering the enormous differences in the weight of these species. Thus, for achieving meaningful results in vaccination and drug efficacy experiments, a refinement and standardization of this experimental model is necessary. Thus, 2 × 10(6), 10(5), 10(4), 10(3) and 10(2) tachyzoites of the highly virulent and well-characterised Nc-Spain7 isolate were subcutaneously inoculated into mice at day 7 of pregnancy, and clinical outcome, vertical transmission, parasite burden and antibody responses were compared. Dams from all infected groups presented nervous signs and the percentage of surviving pups at day 30 postpartum was surprisingly low (24%) in mice infected with only 10(2) tachyzoites. Importantly, infection with 10(5) tachyzoites resulted in antibody levels, cerebral parasite burden in dams and 100% mortality rate in pups, which was identical to infection with 2 × 10(6) tachyzoites. Considering these results, it is reasonable to lower the challenge dose to 10(5) tachyzoites in further experiments when assessing drugs or vaccine candidates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Glycogen is a major substrate in energy metabolism and particularly important to prevent hypoglycemia in pathologies of glucose homeostasis such as type 1 diabetes mellitus (T1DM). (13) C-MRS is increasingly used to determine glycogen in skeletal muscle and liver non-invasively; however, the low signal-to-noise ratio leads to long acquisition times, particularly when glycogen levels are determined before and after interventions. In order to ease the requirements for the subjects and to avoid systematic effects of the lengthy examination, we evaluated if a standardized preparation period would allow us to shift the baseline (pre-intervention) experiments to a preceding day. Based on natural abundance (13) C-MRS on a clinical 3 T MR system the present study investigated the test-retest reliability of glycogen measurements in patients with T1DM and matched controls (n = 10 each group) in quadriceps muscle and liver. Prior to the MR examination, participants followed a standardized diet and avoided strenuous exercise for two days. The average coefficient of variation (CV) of myocellular glycogen levels was 9.7% in patients with T1DM compared with 6.6% in controls after a 2 week period, while hepatic glycogen variability was 13.3% in patients with T1DM and 14.6% in controls. For comparison, a single-session test-retest variability in four healthy volunteers resulted in 9.5% for skeletal muscle and 14.3% for liver. Glycogen levels in muscle and liver were not statistically different between test and retest, except for hepatic glycogen, which decreased in T1DM patients in the retest examination, but without an increase of the group distribution. Since the CVs of glycogen levels determined in a "single session" versus "within weeks" are comparable, we conclude that the major source of uncertainty is the methodological error and that physiological variations can be minimized by a pre-study standardization. For hepatic glycogen examinations, familiarization sessions (MR and potentially strenuous interventions) are recommended. Copyright © 2016 John Wiley & Sons, Ltd.