43 resultados para Screw Extrusion
Resumo:
OBJECTIVE To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks. MATERIALS AND METHODS Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044). CONCLUSIONS Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.
Resumo:
STUDY DESIGN Biomechanical cadaveric study. OBJECTIVE To determine whether augmentation positively influence screw stability or not. SUMMARY OF BACKGROUND DATA Implantation of pedicle screws is a common procedure in spine surgery to provide an anchorage of posterior internal fixation into vertebrae. Screw performance is highly correlated to bone quality. Therefore, polymeric cement is often injected through specifically designed perforated pedicle screws into osteoporotic bone to potentially enhance screw stability. METHODS Caudocephalic dynamic loading was applied as quasi-physiological alternative to classical pull-out tests on 16 screws implanted in osteoporotic lumbar vertebrae and 20 screws in nonosteoporotic specimen. Load was applied using 2 different configurations simulating standard and dynamic posterior stabilization devices. Screw performance was quantified by measurement of screwhead displacement during the loading cycles. To reduce the impact of bone quality and morphology, screw performance was compared for each vertebra and averaged afterward. RESULTS All screws (with or without cement) implanted in osteoporotic vertebrae showed lower performances than the ones implanted into nonosteoporotic specimen. Augmentation was negligible for screws implanted into nonosteoporotic specimen, whereas in osteoporotic vertebrae pedicle screw stability was significantly increased. For dynamic posterior stabilization system an increase of screwhead displacement was observed in comparison with standard fixation devices in both setups. CONCLUSION Augmentation enhances screw performance in patients with poor bone stock, whereas no difference is observed for patients without osteoporosis. Furthermore, dynamic stabilization systems have the possibility to fail when implanted in osteoporotic bone.
Resumo:
OBJECTIVES To compare the free-hand (FH) technique of placing interlocking screws to a commercially available electromagnetic (EM) targeting system in terms of operating time, radiation dose, and accuracy of screw placement. METHODS Between September 2011 and July 2012, we prospectively randomized 100 consecutive femur shaft fractures in 99 patients requiring intramedullary nails to either FH using fluoroscopy (n = 43) or EM targeting (n = 38; Sureshot). SETTING Single Level 1 University Hospital Trauma Center. MAIN OUTCOME MEASUREMENTS The 2 groups were assessed for distal locking with respect to time, radiation, and accuracy. RESULTS Eight-one fractures had data accurately recorded (38 EM/43 FH). The average total operative time was 50 minutes (range, 25-88 minutes; SD, 13.9 minutes) for the FH group and 57 minutes (range, 40-103 minutes; SD, 16.12 minutes) for the EM group. The average time for distal locking was 10 minutes (range, 4-16 minutes; SD, 3.56 minutes) with FH and 11 minutes (range, 6-28 minutes; SD, 10.24 minutes) with EM. Average radiation dose for distal locking was significantly less (P < 0.0001) for EM at 230.54 μGy (range, 51-660 μGy; SD, 0.17 μGy) compared with 690.27 μGy (range, 200-2310 μGy; SD, 0.52 μGy) for FH. There were 2 misplaced drill bits in FH and 3 in EM. This was not statistically significant (P = 0.888). CONCLUSIONS The electromagnetic targeting device (Sureshot) significantly reduced radiation exposure during placement of distal interlocking screws, without sacrificing operative time, and was equivalent in accuracy when compared with the FH technique. LEVEL OF EVIDENCE Therapeutic level II.
Resumo:
OBJECTIVE To assess intramedullary spinal pressure (IMP) in small breed dogs with thoracolumbar disk extrusion. STUDY DESIGN Prospective cohort study. ANIMALS Small breed dogs (n = 14) with thoracolumbar disk extrusion undergoing hemilaminectomy and healthy chondrodystrophic laboratory dogs (control; n = 3) without spinal disease. METHODS Diagnosis was based on clinical and neurological examinations and magnetic resonance imaging (MRI) and was confirmed intraoperatively. A standardized anesthesia protocol and surgical procedure were used to minimize factors that could influence IMP. Intramedullary pressure was measured through a minidurotomy at the site of spinal cord compression using a fiber optic catheter inserted perpendicular to the longitudinal axis of the spinal cord. Measurements were taken after hemilaminectomy and again after removal of extruded disk material. RESULTS Affected dogs had significantly higher IMP compared to control dogs (P = .008) and IMP decreased significantly post-decompression compared with initial values (P < .001). No correlation was found between IMP and neurologic grade, degree of spinal cord compression on MRI, or signal intensity changes on MRI. CONCLUSION Acute thoracolumbar disk extrusion is associated with increased IMP in small breed dogs and surgical decompression results in an immediate decrease of IMP.
Resumo:
INTRODUCTION In iliosacral screw fixation, the dimensions of solely intraosseous (secure) pathways, perpendicular to the ilio-sacral articulation (optimal) with corresponding entry (EP) and aiming points (AP) on lateral fluoroscopic projections, and the factors (demographic, anatomic) influencing these have not yet been described. METHODS In 100 CTs of normal pelvises, the height and width of the secure and optimal pathways were measured on axial and coronal views bilaterally (total measurements: n=200). Corresponding EP and AP were defined as either the location of the screw head or tip at the crossing of lateral innominate bones' cortices (EP) and sacral midlines (AP) within the centre of the pathway, respectively. EP and AP were transferred to the sagittal pelvic view using a coordinate system with the zero-point in the centre of the posterior cortex of the S1 vertebral body (x-axis parallel to upper S1 endplate). Distances are expressed in relation to the anteroposterior distance of the S1 upper endplate (in %). The influence of demographic (age, gender, side) and/or anatomic (PIA=pelvic incidence angle; TCA=transversal curvature angle, PID-Index=pelvic incidence distance-index; USW=unilateral sacral width-index) parameters on pathway dimensions and positions of EP and AP were assessed (multivariate analysis). RESULTS The width, height or both factors of the pathways were at least 7mm or more in 32% and 53% or 20%, respectively. The EP was on average 14±24% behind the centre of the posterior S1 cortex and 41±14% below it. The AP was on average 53±7% in the front of the centre of the posterior S1 cortex and 11±7% above it. PIA influenced the width, TCA, PID-Index the height of the pathways. PIA, PID-Index, and USW-Index significantly influenced EP and AP. Age, gender, and TCA significantly influenced EP. CONCLUSION Secure and optimal placement of screws of at least 7mm in diameter will be unfeasible in the majority of patients. Thoughtful preoperative planning of screw placement on CT scans is advisable to identify secure pathways with an optimal direction. For this purpose, the presented methodology of determining and transferring EPs and APs of corresponding pathways to the sagittal pelvic view using a coordinate system may be useful.
Resumo:
OBJECTIVE: Mechanical evaluation of a novel screw position used for repair in a type III distal phalanx fracture model and assessment of solar canal penetration (SCP). STUDY DESIGN: Experimental study. SAMPLE POPULATION: Disarticulated equine hooves (n = 24) and 24 isolated distal phalanges. METHODS: Hooves/distal phalanges cut in a sagittal plane were repaired with 1 of 2 different cortical screw placements in lag fashion. In group 1 (conventional screw placement), the screw was inserted halfway between the proximal border of the solar canal (SC) and the subchondral bone surface on a line parallel to the dorsal cortex, whereas in group 2, the screw was inserted more palmar/plantar, where a perpendicular line drawn from the group 1 position reached the palmar/plantar cortex. Construct strength was evaluated by 3-point bending to failure. SCP was assessed by CT imaging and macroscopically. RESULTS: Screws were significantly longer in group 2 and in forelimbs. Group 2 isolated distal phalanges had a significantly more rigid fixation compared with the conventional screw position (maximum point at failure 31%, bending stiffness 41% higher). Lumen reduction of the SC was observed in 13/52 specimens (all from group 2), of which 9 were forelimbs. CONCLUSIONS: More distal screw positioning compared with the conventionally recommended screw position for internal fixation of type III distal phalangeal fractures allows placement of a longer screw and renders a more rigid fracture fixation. The novel screw position, however, carries a higher risk of SCP
Resumo:
OBJECTIVE: To describe (1) preoperative findings and surgical technique, (2) intraoperative difficulties, and (3) postoperative complications and long-term outcome of equine cheek tooth extraction using a minimally invasive transbuccal screw extraction (MITSE) technique. STUDY DESIGN: Retrospective case series. ANIMALS: Fifty-four equids; 50 horses, 3 ponies, and 1 mule. METHODS: Fifty-eight MITSE procedures were performed to extract cheek teeth in 54 equids. Peri- and intraoperative difficulties, as well as short- (<1 month) and long-term (>6 months) postoperative complications were recorded. Followup information was obtained through telephone interviews, making specific inquiries about nasal discharge, facial asymmetry, and findings consistent with surgical site infection. RESULTS: Preoperative findings that prompted exodontia included 50 cheek teeth with apical infections, 48 fractures, 4 neoplasia, 2 displacements, and 1 supernumerary tooth. Previous oral extraction was attempted but had failed in 55/58 (95%) animals because of cheek tooth fracture in 28, or insufficient clinical crown for extraction with forceps in 27. MITSE was successful in removing the entire targeted dental structure in 47/58 (81%) procedures. However, MITSE failed to remove the entire targeted dental structure in 11/58 (19%) procedures and was followed by repulsion in 10/11 (91%). Short-term postoperative complications included bleeding (4/58 procedures, 7%) and transient facial nerve paralysis (4/58 procedures, 7%). Owners were satisfied with the functional and cosmetic outcome for 40/41 (98%) animals with followup. CONCLUSION: MITSE offers an alternate for cheek tooth extraction in equids, where conventional oral extraction is not possible or has failed. Overall, there was low morbidity, which compares favorably with invasive buccotomy or repulsion techniques
Resumo:
Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.
Resumo:
OBJECTIVE To determine the biomechanical effect of an intervertebral spacer on construct stiffness in a PVC model and cadaveric canine cervical vertebral columns stabilized with monocortical screws/polymethylmethacrylate (PMMA). STUDY DESIGN Biomechanical study. SAMPLE POPULATION PVC pipe; cadaveric canine vertebral columns. METHODS PVC model-PVC pipe was used to create a gap model mimicking vertebral endplate orientation and disk space width of large-breed canine cervical vertebrae; 6 models had a 4-mm gap with no spacer (PVC group 1); 6 had a PVC pipe ring spacer filling the gap (PCV group 2). Animals-large breed cadaveric canine cervical vertebral columns (C2-C7) from skeletally mature dogs without (cadaveric group 1, n = 6, historical data) and with an intervertebral disk spacer (cadaveric group 2, n = 6) were used. All PVC models and cadaver specimens were instrumented with monocortical titanium screws/PMMA. Stiffness of the 2 PVC groups was compared in extension, flexion, and lateral bending using non-destructive 4-point bend testing. Stiffness testing in all 3 directions was performed of the unaltered C4-C5 vertebral motion unit in cadaveric spines and repeated after placement of an intervertebral cortical allograft ring and instrumentation. Data were compared using a linear mixed model approach that also incorporated data from previously tested spines with the same screw/PMMA construct but without disk spacer (cadaveric group 1). RESULTS Addition of a spacer increased construct stiffness in both the PVC model (P < .001) and cadaveric vertebral columns (P < .001) compared to fixation without a spacer. CONCLUSIONS Addition of an intervertebral spacer significantly increased construct stiffness of monocortical screw/PMMA fixation.
Resumo:
OBJECTIVE To compare biomechanical stiffness of cadaveric canine cervical spine constructs stabilized with bicortical stainless steel pins and polymethylmethacrylate (PMMA), monocortical stainless steel screws with PMMA, or monocortical titanium screws with PMMA. STUDY DESIGN Biomechanical cadaver study. ANIMALS Eighteen canine cervical vertebral columns (C2-C7) were collected from skeletally mature dogs (weighing 22-32 kg). METHODS Specimens were radiographed and examined by dual energy X-ray absorptiometry. Stiffness of the unaltered C4-C5 intervertebral motion unit was measured in extension, flexion and lateral bending using non-destructive 4-point bend testing. Specimens were then stabilized by (1) bicortical stainless steel pins/PMMA, (2) monocortical stainless steel screws/PMMA, or (3) monocortical titanium screws/PMMA. Mechanical testing was repeated and stiffness data from unaltered specimens and the 3 treatment groups were compared. RESULTS All 3 surgical methods significantly increased stiffness of the C4-C5 motion unit compared with the unaltered specimen (P < .001 for all treatments), but stiffness was not significantly different among the 3 fixation groups (P = .578). CONCLUSIONS In this model, monocortical screw fixation (with stainless steel or titanium screws) was biomechanically equivalent to bicortical fixation.
Resumo:
OBJECTIVE To report findings and outcomes of dogs with reherniation of nuclear material within 7 days of hemilaminectomy for acute thoracolumbar (TL) intervertebral disk extrusion. STUDY DESIGN Retrospective case series. ANIMALS Chondrodystrophic dogs (n = 11). METHODS Dogs with acute neurologic decline within 1 week of surgical decompression for TL disk extrusion were identified. Advanced imaging was used to document extradural spinal cord compression at the previous surgery site. Ten dogs had a 2nd decompressive surgery to remove extruded nuclear material. RESULTS All dogs had acute neurologic deterioration (average, 2 neurologic grades) 2-7 days after initial hemilaminectomy. Computed tomography (CT; n = 10) or myelography (n = 1) documented extradural spinal cord compression compatible with extruded disk material at the previous hemilaminectomy site. Dogs that had a 2nd surgical decompression improved neurologically within 24 hours and were paraparetic at discharge. The single dog that did not have decompressive surgery did not regain deep nociception during 185-day follow-up. CONCLUSIONS Early reherniation at the site of previous hemilaminectomy can produce acute deterioration of neurologic function and should be investigated with diagnostic imaging. Repeat decompressive surgery can lead to functional recovery.
Resumo:
OBJECTIVE To determine whether body weight, body condition score, or various body dimensions were associated with acute thoracolumbar intervertebral disk extrusion or protrusion and whether any of these factors were associated with severity of clinical signs in Dachshunds. DESIGN Cross-sectional clinical study. ANIMALS 75 Dachshunds with (n = 39) or without (36) acute thoracolumbar intervertebral disk extrusion or protrusion. PROCEDURES Signalment, various body measurements, body weight, body condition score, and spinal cord injury grade were recorded at the time of initial examination. RESULTS Mean T1-S1 distance and median tuber calcaneus-to-patellar tendon (TC-PT) distance were significantly shorter in affected than in unaffected dogs. A 1-cm decrease in T1-S1 distance was associated with a 2.1-times greater odds of being affected, and a 1-cm decrease in TC-PT distance was associated with an 11.1-times greater odds of being affected. Results of multivariable logistic regression also indicated that affected dogs were taller at the withers and had a larger pelvic circumference than unaffected dogs, after adjusting for other body measurements. Results of ordinal logistic regression indicated that longer T1-S1 distance, taller height at the withers, and smaller pelvic circumference were associated with more severe spinal cord injury. CONCLUSIONS AND CLINICAL RELEVANCE Results suggest that certain body dimensions may be associated with acute thoracolumbar intervertebral disk extrusion or protrusion in Dachshunds and, in affected dogs, with severity of neurologic dysfunction.
Resumo:
BACKGROUND Little information is yet available on zirconia-based prostheses supported by implants. PURPOSE To evaluate technical problems and failures of implant-supported zirconia-based prostheses with exclusive screw-retention. MATERIAL AND METHODS Consecutive patients received screw-retained zirconia-based prostheses supported by implants and were followed over a time period of 5 years. The implant placement and prosthetic rehabilitation were performed in one clinical setting, and all patients participated in the maintenance program. The treatment comprised single crowns (SCs) and fixed dental prostheses (FDPs) of three to 12 units. Screw-retention of the CAD/CAM-fabricated SCs and FDPs was performed with direct connection at the implant level. The primary outcome was the complete failure of zirconia-based prostheses; outcome measures were fracture of the framework or extensive chipping resulting in the need for refabrication. A life table analysis was performed, the cumulative survival rate (CSR) calculated, and a Kaplan-Meier curve drawn. RESULTS Two hundred and ninety-four implants supported 156 zirconia-based prostheses in 95 patients (52 men, 43 women, average age 59.1 ± 11.7 years). Sixty-five SCs and 91 FDPs were identified, comprising a total of 441 units. Fractures of the zirconia framework and extensive chipping resulted in refabrication of nine prostheses. Nearly all the prostheses (94.2%) remained in situ during the observation period. The 5-year CSR was 90.5%, and 41 prostheses (14 SCs, 27 FDPs) comprising 113 units survived for an observation time of more than 5 years. Six SCs exhibited screw loosening, and polishing of minor chipping was required for five prostheses. CONCLUSIONS This study shows that zirconia-based implant-supported fixed prostheses exhibit satisfactory treatment outcomes and that screw-retention directly at the implant level is feasible.