108 resultados para Radiography, Panoramic.
Resumo:
OBJECTIVE: In this experimental study we assessed the diagnostic performance of digital linear slit scanning radiography compared with computed radiography (CR) for the detection of urinary calculi in an anthropomorphic phantom imitating patients weighing approximately 58-88 kg. CONCLUSION: Compared with CR, linear slit scanning radiography is superior for the detection of urinary stones and may be used for pretreatment localization and follow-up at a lower patient exposure.
Resumo:
The purpose of this retrospective study was to intra-individually compare the image quality of computed radiography (CR) and low-dose linear-slit digital radiography (LSDR) for supine chest radiographs. A total of 90 patients (28 female, 62 male; mean age, 55.1 years) imaged with CR and LSDR within a mean time interval of 2.8 days +/- 3.0 were included in this study. Two independent readers evaluated the image quality of CR and LSDR based on modified European Guidelines for Quality Criteria for chest X-ray. The Wilcoxon test was used to analyse differences between the techniques. The overall image quality of LSDR was significantly better than the quality of CR (9.75 vs 8.16 of a maximum score of 10; p < 0.001). LSDR performed significantly better than CR for delineation of anatomical structures in the mediastinum and the retrocardiac lung (p < 0.001). CR was superior to LSDR for visually sharp delineation of the lung vessels and the thin linear structures in the lungs. We conclude that LSDR yields better image quality and may be more suitable for excluding significant pathological features of the chest in areas with high attenuation compared with CR.
Resumo:
This paper presents a clinical and anatomical review of the mental foramen (MF) based on recent publications (since 1990). Usually, the MF is located below the 2nd premolar or between the two premolars, but it may also be positioned below the 1st premolar or below the mesial root of the 1st molar. At the level of the MF, lingual canals may join the mandibular canal (hence the term "crossroads"). Accessory MF are frequently described in the literature with large ethnic variations in incidence. The emergence pattern of the mental canal usually has an upward and posterior direction. The presence and extent of an "anterior loop" of the mental canal may be overestimated with panoramic radiography. Limited cone-beam computed tomography currently appears to be the most precise radiographic technique for assessment of the "anterior loop". The mental nerve exiting the MF usually has three to four branches for innervation of the soft tissues of the chin, lower lip, facial gingiva and mucosa in the anterior mandible. The clinician is advised to observe a safety distance when performing incisions and osteotomies in the vicinity of the MF.
Resumo:
OBJECTIVES To assess the diagnostic value of panoramic views (2D) of patients with impacted maxillary canines by a group of trained orthodontists and oral surgeons, and to quantify the subjective need and reasons for further three-dimensional (3D) imaging. MATERIALS AND METHODS The study comprises 60 patients with panoramic radiographs (2D) and cone beam computed tomography (CBCT) scans (3D), and a total of 72 impacted canines. Data from a standardized questionnaire were compared within (intragroup) and between (intergroup) a group of orthodontists and oral surgeons to assess possible correlations and differences. Furthermore, the questionnaire data were compared with the findings from the CBCT scans to estimate the correlation within and between the two specialties. Finally, the need and reasons for further 3D imaging was analysed for both groups. RESULTS When comparing questionnaire data with the analysis of the respective CBCT scans, orthodontists showed probability (Pr) values ranging from 0.443 to 0.943. Oral surgeons exhibited Pr values from 0.191 to 0.946. Statistically significant differences were found for the labiopalatal location of the impacted maxillary canine (P = 0.04), indicating a higher correlation in the orthodontist group. The most frequent reason mentioned for the further need of 3D analysis was the labiopalatal location of the impacted canines. Oral surgeons were more in favour of performing further 3D imaging (P = 0.04). CONCLUSIONS Orthodontists were more likely to diagnose the exact labiopalatal position of impacted maxillary canines when using panoramic views only. Generally, oral surgeons more often indicated the need for further 3D imaging.
Resumo:
OBJECTIVES To assess the literature on carotid calcifications defined from panoramic radiographs (PMX) and concurrent diagnosis of stroke and periodontitis. MATERIALS AND METHODS A literature search screening for publications using search terms such as PMX and carotid calcification, stroke and periodontitis was performed in November 2012. RESULTS A total of 189 articles were retrieved, among which 30 were included in the review. The sensitivity for PMX findings of carotid calcifications (CC) compared to a diagnosis by Doppler sonography varied between 31.1-100%. The specificity for PMX findings of carotid calcifications compared to a diagnosis by Doppler sonography varied between 21.4-87.5%. Individuals with CC findings from PMX have more periodontitis and risk for stroke. CONCLUSIONS There is a shortage of well-designed studies in older dentate individuals assessing the associations between periodontitis and radiographic evidence of CC and in relation to stroke or other cardiovascular diseases. STATEMENT OF CLINICAL RELEVANCE: Carotid calcifications are prevalent in patients with periodontitis and such individuals may have an increased risk for stroke. The absence of signs of carotid calcification on panoramic radiographs is indicative of no calcification of carotid arteries.
Resumo:
OBJECTIVE The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. MATERIALS AND METHODS We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. RESULTS A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1% ± 2.2% versus 85.6% ± 5.6% (p = 0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7% ± 8.1% (with bone suppression, 46.1% ± 8%; p = 0.94); for microdose CT, nodule sensitivity was 83.6% ± 9% without MIP (with additional MIP, 92.5% ± 6%; p < 10(-3)). Individual sensitivities of microdose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (p < 10(-6)). The effective dose for chest radiography including dual-energy subtraction was 0.242 mSv; for microdose CT, the applied dose was 0.1323 mSv. CONCLUSION Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.
Resumo:
In many designs for radioactive waste repositories, cement and clay will come into direct contact. The geochemical contrast between cement and clay will lead to mass fluxes across the interface, which consequently results in alteration of structural and transport properties of both materials that may affect the performance of the multi-barrier system. We present an experimental approach to study cement-clay interactions with a cell to accommodate small samples of cement and clay. The cell design allows both in situ measurement of water content across the sample using neutron radiography and measurement of transport parameters using through-diffusion tracer experiments. The aim of the high- resolution neutron radiography experiments was to monitor changes in water content (porosity) and their spatial extent. Neutron radiographs of several evolving cement-clay interfaces delivered quantitative data which allow resolving local water contents within the sample domain. In the present work we explored the uncertainties of the derived water contents with regard to various input parameters and with regard to the applied image correction procedures. Temporal variation of measurement conditions created absolute uncertainty of the water content in the order of ±0.1 (m3/m3), which could not be fully accounted for by correction procedures. Smaller relative changes in water content between two images can be derived by specific calibrations to two sample regions with different, invariant water contents.
Resumo:
BACKGROUND AND OBJECTIVES Despite the recommendations of national and international societies for the treatment of patients with acute neck and back pain, still too many radiologic examinations were performed. The purpose of this study was to analyze and optimize diagnostics and treatment of patients with acute back pain. METHODS The medical records of 484 patients presented to the emergency clinic with acute neck or back pain were analyzed for clinical history, physical examination, radiographic findings and therapy. RESULTS Radiographs of the lumbar, cervical, or thoracic spine were performed in 338 cases (70%). Radiographs were normal in 142 patients (42%) and degenerative changes were identified in 123 patients (36%). Only 2 patients (0.4%) had radiographic findings that had direct therapeutic relevance: 1 patient with metastatic disease and 1 patient with posttraumatic C1-C2 instability. For most patients without sensorimotor deficits and absent specific indications for radiography (“red flags”), therapy was not affected by the results of radiography. CONCLUSIONS Plain radiography of the spine was unnecessary in most patients initially evaluated with non-specific acute back pain and does not improve the clinical outcome. The implementation of national and international guidelines is a slow process, but helps to reduce costs and to protect patients from unnecessary ionizing radiation exposure.
Resumo:
OBJECTIVE To compare the accuracy of radiography and computed tomography (CT) in predicting implant position in relation to the vertebral canal in the cervical and thoracolumbar vertebral column. STUDY DESIGN In vitro imaging and anatomic study. ANIMALS Medium-sized canine cadaver vertebral columns (n=12). METHODS Steinmann pins were inserted into cervical and thoracolumbar vertebrae based on established landmarks but without predetermination of vertebral canal violation. Radiographs and CT images were obtained and evaluated by 6 individuals. A random subset of pins was evaluated for ability to distinguish left from right pins on radiographs. The ability to correctly identify vertebral canal penetration for all pins was assessed both on radiographs and CT. Spines were then anatomically prepared and visual examination of pin penetration into the canal served as the gold standard. RESULTS Left/right accuracy was 93.1%. Overall sensitivity of radiographs and CT to detect vertebral canal penetration by an implant were significantly different and estimated as 50.7% and 93.4%, respectively (P<.0001). Sensitivity was significantly higher for complete versus partial penetration and for radiologists compared with nonradiologists for both imaging modalities. Overall specificity of radiographs and CT to detect vertebral canal penetration was 82.9% and 86.4%, respectively (P=.049). CONCLUSIONS CT was superior to radiographic assessment and is the recommended imaging modality to assess penetration into the vertebral canal. CLINICAL RELEVANCE CT is significantly more accurate in identifying vertebral canal violation by Steinmann pins and should be performed postoperatively to assess implant position.
Resumo:
In clinical medicine, plane radiography is used for detecting the remains of medications in the stomach in oral medication intoxication cases. Since postmortem computed tomography (CT), performed prior to autopsy, is currently intensively entering the forensic routine, the technique was applied to three fatal cases of oral medication intoxication. Here we report CT and autopsy findings for these cases. In all three cases, hyperdense areas within the stomach content were documented. The measurement of Hounsfield Units (HU) beyond 74HU showed mean values of 338, 88 and 98HU. Postmortem CT also showed brain edema and pulmonary aspiration in one case. At autopsy, tablet remains in the stomach were detected microscopically in all three cases. The ex vivo CT scans of the ingested medicaments showed similar HU values. Despite the fact that further case studies are necessary beyond this one, and in spite of its limitations, postmortem CT was found to be a useful screening and documentation method for stomach contents in oral medication intoxication.
Resumo:
Musculoskeletal ultrasonography (US) is an established and validated imaging technique in rheumatology. Ultrasonography is able to directly visualize soft tissue pathologies such as synovial tissue changes. Pathological findings in superficial cartilage, bone lesions and synovial tissue changes in the context of rheumatoid arthritis, spondyloarthritis or crystal arthropathies may only be seen by sonography or detected earlier by ultrasonography compared to conventional imaging techniques. The activity of an inflammatory arthropathy can be visualized using Doppler and power Doppler US. US is helpful in the detection of early inflammatory changes, particularly in patients with undifferentiated arthritis and/or unremarkable conventional radiography. In addition to diagnosis in early arthritis and monitoring of therapy in rheumatoid arthritis, sonography is able to detect pivotal pathologies in spondyloarthritis and crystal deposition diseases such as gout, pseudogout and apatite deposition disease. Ultrasound-guided diagnostic and therapeutic interventions are characterized by their excellent accuracy and improvement of clinical effectiveness compared to unguided procedures. In conclusion, ultrasonography plays a pivotal role in the assessment and monitoring of therapy in rheumatic diseases.
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.
Resumo:
A 19-year old female patient was referred for removal of her wisdom teeth. The panoramic radiograph showed bilateral retromolar canals in the mandible. Since the retromolar canal is neglected in anatomical textbooks and is rarely documented in scientific publications, the case prompted us to perform further diagnostic examinations with informed consent by the patient. A limited cone beam computed tomography was made and, during the surgical removal of the patient's lower right wisdom tooth, a biopsy of the soft tissue bundle emerging from the retromolar foramen was taken. In accordance with the literature, the histology revealed myelinated nerve fibers, small arteries and venules. The limited data available in the literature about the retromolar canal report that this bony canal may convey an aberrant buccal nerve. In addition, sensory nerve fibers entering the retromolar canal from above and branching to the mandibular molars may evade a block anesthesia at the mandibular foramen. These rare anatomic features may explain why the elements of the retromolar canal account for failures of mandibular block anesthesia or postsurgical sensitivity changes in the supply area of the buccal nerve.