48 resultados para Oxo-biodegradable additives
Resumo:
BACKGROUND Refinements in stent design affecting strut thickness, surface polymer, and drug release have improved clinical outcomes of drug-eluting stents. We aimed to compare the safety and efficacy of a novel, ultrathin strut cobalt-chromium stent releasing sirolimus from a biodegradable polymer with a thin strut durable polymer everolimus-eluting stent. METHODS We did a randomised, single-blind, non-inferiority trial with minimum exclusion criteria at nine hospitals in Switzerland. We randomly assigned (1:1) patients aged 18 years or older with chronic stable coronary artery disease or acute coronary syndromes undergoing percutaneous coronary intervention to treatment with biodegradable polymer sirolimus-eluting stents or durable polymer everolimus-eluting stents. Randomisation was via a central web-based system and stratified by centre and presence of ST segment elevation myocardial infarction. Patients and outcome assessors were masked to treatment allocation, but treating physicians were not. The primary endpoint, target lesion failure, was a composite of cardiac death, target vessel myocardial infarction, and clinically-indicated target lesion revascularisation at 12 months. A margin of 3·5% was defined for non-inferiority of the biodegradable polymer sirolimus-eluting stent compared with the durable polymer everolimus-eluting stent. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT01443104. FINDINGS Between Feb 24, 2012, and May 22, 2013, we randomly assigned 2119 patients with 3139 lesions to treatment with sirolimus-eluting stents (1063 patients, 1594 lesions) or everolimus-eluting stents (1056 patients, 1545 lesions). 407 (19%) patients presented with ST-segment elevation myocardial infarction. Target lesion failure with biodegradable polymer sirolimus-eluting stents (69 cases; 6·5%) was non-inferior to durable polymer everolimus-eluting stents (70 cases; 6·6%) at 12 months (absolute risk difference -0·14%, upper limit of one-sided 95% CI 1·97%, p for non-inferiority <0·0004). No significant differences were noted in rates of definite stent thrombosis (9 [0·9%] vs 4 [0·4%], rate ratio [RR] 2·26, 95% CI 0·70-7·33, p=0·16). In pre-specified stratified analyses of the primary endpoint, biodegradable polymer sirolimus-eluting stents were associated with improved outcome compared with durable polymer everolimus-eluting stents in the subgroup of patients with ST-segment elevation myocardial infarction (7 [3·3%] vs 17 [8·7%], RR 0·38, 95% CI 0·16-0·91, p=0·024, p for interaction=0·014). INTERPRETATION In a patient population with minimum exclusion criteria and high adherence to dual antiplatelet therapy, biodegradable polymer sirolimus-eluting stents were non-inferior to durable polymer everolimus-eluting stents for the combined safety and efficacy outcome target lesion failure at 12 months. The noted benefit in the subgroup of patients with ST-segment elevation myocardial infarction needs further study. FUNDING Clinical Trials Unit, University of Bern, and Biotronik, Bülach, Switzerland.
Resumo:
OBJECTIVE To investigate clinical outcomes of coronary intervention using a biolimus-eluting stent (BES) compared with a sirolimus-eluting stent (SES) in patients with acute myocardial infarction (AMI) in the Limus Eluted from A Durable versus ERodable Stent (LEADERS) coating trial at the final 5-year follow-up. METHODS The LEADERS trial is a multicentre all-comer study, where patients (n=1707) were randomised to percutaneous intervention with either BES containing biodegradable polymer or SES containing durable polymer. Out of 1707 patients enrolled in this trial, 573 patients had percutaneous coronary intervention for AMI (BES=280, SES=293) and were included in the current analysis. Patient-oriented composite endpoint (POCE, including all death, all myocardial infarction (MI) and all revascularisations), major adverse cardiac events (MACE, including cardiac death, MI and clinically indicated target vessel revascularisation) and stent thrombosis were assessed at 5-year follow-up. RESULTS The baseline clinical, angiographic and procedural characteristics were well matched between BES and SES groups. In all patients with AMI, coronary intervention with a BES, compared with SES, significantly reduced POCE (28.9% vs 42.3%; relative risk (RR) 0.61, 95% CI 0.47 to 0.82, p=0.001) at 5-year follow-up. There was also a reduction in MACE rate in the BES group (18.2% vs 25.9%; RR 0.67, 95% CI 0.47 to 0.95, p=0.025); however, there was no difference in cardiac death and stent thrombosis. In patients with ST-elevation MI (STEMI), coronary intervention with BES significantly reduced POCE (24.4% vs 39.3%; RR 0.55, 95% CI 0.36 to 0.85, p=0.006), MACE (12.6% vs 25.0%; RR 0.47, 95% CI 0.26 to 0.83, p=0.008) and cardiac death (3.0% vs 11.4%; RR 0.25, 95% CI 0.08 to 0.75, p=0.007), along with a trend towards reduction in definite stent thrombosis (3.7% vs 8.6%; RR 0.41, 95% CI 0.15 to 1.18, p=0.088), compared with SES. CONCLUSIONS BES, compared with SES, significantly improved safety and efficacy outcomes in patients with AMI, especially those with STEMI, at 5-year follow-up. TRIAL REGISTRATION NUMBER NCT 00389220.
Resumo:
BACKGROUND Biodegradable polymers for release of antiproliferative drugs from drug-eluting stents aim to improve vascular healing. We assessed noninferiority of a novel ultrathin strut drug-eluting stent releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) compared with the durable polymer Xience Prime everolimus-eluting stent (X-EES) in terms of the primary end point in-stent late lumen loss at 9 months. METHODS AND RESULTS A total of 452 patients were randomly assigned 2:1 to treatment with O-SES (298 patients, 332 lesions) or X-EES (154 patients, 173 lesions) in a multicenter, noninferiority trial. The primary end point was in-stent late loss at 9 months. O-SES was noninferior to X-EES for the primary end point (0.10±0.32 versus 0.11±0.29 mm; difference=0.00063 mm; 95% confidence interval, -0.06 to 0.07; Pnoninferiority<0.0001). Clinical outcome showed similar rates of target-lesion failure at 1 year (O-SES 6.5% versus X-EES 8.0%; hazard ratio=0.82; 95% confidence interval, 0.40-1.68; log-rank test: P=0.58) without cases of stent thrombosis. A subgroup of patients (n=55) underwent serial optical coherence tomography at 9 months, which demonstrated similar neointimal thickness among lesions allocated to O-SES and X-EES (0.10±0.04 mm versus 0.11±0.04 mm; -0.01 [-0.04, -0.01]; P=0.37). Another subgroup of patients (n=56) underwent serial intravascular ultrasound at baseline and 9 months indicating a potential difference in neointimal area at follow-up (O-SES, 0.16±0.33 mm(2) versus X-EES, 0.43±0.56 mm(2); P=0.04). CONCLUSIONS Compared with durable polymer X-EES, novel biodegradable polymer-based O-SES was found noninferior for the primary end point in-stent late lumen loss at 9 months. Clinical event rates were comparable without cases of stent thrombosis throughout 1 year of follow-up. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01356888.
Resumo:
Lead is efficiently protected against cathodic corrosion by the addition of diammonium salts in the electrolyte. The cationic coating of the cathode allows the efficient electroreduction of benzamides to benzylamines. The electrochemical deoxygenation of the amide is achieved without the use of oxophilic agents or sacrificial anodes. The surface of the lead cathode stays smooth and the cathode can be reused for multiple runs, providing <2.5 ppm of the crude product. Cyclic voltammetry studies reveal a shift in the onset potential of the hydrogen evolution reaction by −157 mV.
Resumo:
BACKGROUND Ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES) proved noninferior to durable polymer everolimus-eluting stents (DP-EES) for a composite clinical end point in a population with minimal exclusion criteria. We performed a prespecified subgroup analysis of the Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation (BIOSCIENCE) trial to compare the performance of BP-SES and DP-EES in patients with diabetes mellitus. METHODS AND RESULTS BIOSCIENCE trial was an investigator-initiated, single-blind, multicentre, randomized, noninferiority trial comparing BP-SES versus DP-EES. The primary end point, target lesion failure, was a composite of cardiac death, target-vessel myocardial infarction, and clinically indicated target lesion revascularization within 12 months. Among a total of 2119 patients enrolled between February 2012 and May 2013, 486 (22.9%) had diabetes mellitus. Overall diabetic patients experienced a significantly higher risk of target lesion failure compared with patients without diabetes mellitus (10.1% versus 5.7%; hazard ratio [HR], 1.80; 95% confidence interval [CI], 1.27-2.56; P=0.001). At 1 year, there were no differences between BP-SES versus DP-EES in terms of the primary end point in both diabetic (10.9% versus 9.3%; HR, 1.19; 95% CI, 0.67-2.10; P=0.56) and nondiabetic patients (5.3% versus 6.0%; HR, 0.88; 95% CI, 0.58-1.33; P=0.55). Similarly, no significant differences in the risk of definite or probable stent thrombosis were recorded according to treatment arm in both study groups (4.0% versus 3.1%; HR, 1.30; 95% CI, 0.49-3.41; P=0.60 for diabetic patients and 2.4% versus 3.4%; HR, 0.70; 95% CI, 0.39-1.25; P=0.23, in nondiabetics). CONCLUSIONS In the prespecified subgroup analysis of the BIOSCIENCE trial, clinical outcomes among diabetic patients treated with BP-SES or DP-EES were comparable at 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01443104.
Resumo:
AIMS Our aim was to compare the safety and efficacy of a novel, ultrathin strut, biodegradable polymer sirolimus-eluting stent (BP-SES) with a thin strut, durable polymer everolimus-eluting stent (DP-EES) in a pre-specified subgroup of patients with acute ST-segment elevation myocardial infarction (STEMI) enrolled in the BIOSCIENCE trial. METHODS AND RESULTS The BIOSCIENCE trial is an investigator-initiated, single-blind, multicentre, randomised non-inferiority trial (NCT01443104). Randomisation was stratified according to the presence or absence of STEMI. The primary endpoint, target lesion failure (TLF), is a composite of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularisation within 12 months. Between February 2012 and May 2013, 407 STEMI patients were randomly assigned to treatment with BP-SES or DP-EES. At one year, TLF occurred in seven (3.4%) patients treated with BP-SES and 17 (8.8%) patients treated with DP-EES (RR 0.38, 95% CI: 0.16-0.91, p=0.024). Rates of cardiac death were 1.5% in the BP-SES group and 4.7% in the DP-EES group (RR 0.31, 95% CI: 0.08-1.14, p=0.062); rates of target vessel myocardial infarction were 0.5% and 2.6% (RR 0.18, 95% CI: 0.02-1.57, p=0.082), respectively, and rates of clinically indicated target lesion revascularisation were 1.5% in the BP-SES group versus 2.1% in the DP-EES group (RR 0.69, 95% CI: 0.16-3.10, p=0.631). There was no difference in the risk of definite stent thrombosis. CONCLUSIONS In this pre-specified subgroup analysis, BP-SES was associated with a lower rate of target lesion failure at one year compared to DP-EES in STEMI patients. These findings require confirmation in a dedicated STEMI trial.