44 resultados para Multidimensional projection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complexity of the equine skull makes the temporomandibular joint a difficult area to evaluate radiographically. The goal of this study was to determine the optimal angle for a complementary radiographic projection of the equine temporomandibular joint based on a computed tomography (CT) cadaver study. CT was performed on six equine cadaver heads of horses that were euthanized for other reasons than temporomandibular joint disease. After the CT examination, 3D reconstruction of the equine skull was performed to subjectively determine the angle for a complementary radiographic projection of the temporomandibular joint. The angle was measured on the left and right temporomandibular joint of each head. Based on the measurements obtained from the CT images, a radiographic projection of the temporomandibular joint in a rostra-145 degrees ventral-caudodorsal oblique (R45 degrees V-CdDO) direction was developed by placing the X-ray unit 30 degrees laterally, maintaining at the same time the R45 degrees V-CdDO angle (R45 degrees V30 degrees L-CdDLO). This radiographic projection was applied to all cadaver heads and on six live horses. In three of the live horses abnormal findings associated with the temporomandibular joint were detected. We conclude that this new radiographic projection of the temporomandibular joint provides superior visualization of the temporomandibular joint space and the articular surface of the mandibular condyle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite efforts implicating the cationic channel transient receptor potential melastatin member 4 (TRPM4) to cardiac, nervous, and immunological pathologies, little is known about its structure and function. In this study, we optimized the requirements for purification and extraction of functional human TRPM4 protein and investigated its supra-molecular assembly. We selected the Xenopus laevis oocyte expression system because it lacks endogenous TRPM4 expression, it is known to overexpress functional human membrane channels, can be used for structure-function analysis within the same system, and is easily scaled to improve yield and develop moderate throughput capabilities through the use of robotics. Negative-stain electron microscopy (EM) revealed various sized low-resolution particles. Single particle analysis identified the majority of the projections represented the monomeric form with additional oligomeric structures potentially characterized as tetramers. Two-electrode voltage clamp electrophysiology demonstrated that human TRPM4 is functionally expressed at the oocyte plasma membrane. This study opens the door for medium-throughput screening and structure-function determination of this important therapeutically relevant target.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mesoscopic 3D imaging has become a widely used optical imaging technique to visualize intact biological specimens. Selective plane illumination microscopy (SPIM) visualizes samples up to a centimeter in size with micrometer resolution by 3D data stitching but is limited to fluorescent contrast. Optical projection tomography (OPT) works with fluorescent and nonfluorescent contrasts, but its resolution is limited in large samples. We present a hybrid setup (OPTiSPIM) combining the advantages of each technique. The combination of fluorescent and nonfluorescent high-resolution 3D data into integrated datasets enables a more extensive representation of mesoscopic biological samples. The modular concept of the OPTiSPIM facilitates incorporation of the transmission OPT modality into already established light sheet based imaging setups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an indicator for measuring multidimensional poverty in the Lao People’s Democratic Republic applying the Alkire–Foster methodology to the Lao Expenditure and Consumption Survey 2002/2003 and 2007/2008. We calculated a multidimensional poverty index (MPI) that includes three dimensions: education, health, and standard of living. Making use of the MPI’s decomposability, we analyse how much each of the different dimensions and its respective indicators contribute to the overall MPI. We find a marked reduction in the multidimensional poverty headcount ratio over the study period, regardless of how the indicators are weighted or how the deprivation and poverty cut-offs are set. This reduction is based on improvements regarding all indicators except cooking fuel and nutrition. We observe no significant reduction in the intensity of poverty, however; there are wide disparities between the country’s regions and between urban and rural areas. The proportion of poor people in rural areas is more than twice as high as that in urban areas. By complementing the traditional income-based poverty measure, we hope to provide useful information that can support knowledge-based decision-making for poverty alleviation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSES Geriatric problems frequently go undetected in older patients in emergency departments (EDs), thus increasing their risk of adverse outcomes. We evaluated a novel emergency geriatric screening (EGS) tool designed to detect geriatric problems. BASIC PROCEDURES The EGS tool consisted of short validated instruments used to screen 4 domains (cognition, falls, mobility, and activities of daily living). Emergency geriatric screening was introduced for ED patients 75 years or older throughout a 4-month period. We analyzed the prevalence of abnormal EGS and whether EGS increased the number of EGS-related diagnoses in the ED during the screening, as compared with a preceding control period. MAIN FINDINGS Emergency geriatric screening was performed on 338 (42.5%) of 795 patients presenting during screening. Emergency geriatric screening was unfeasible in 175 patients (22.0%) because of life-threatening conditions and was not performed in 282 (35.5%) for logistical reasons. Emergency geriatric screening took less than 5 minutes to perform in most (85.8%) cases. Among screened patients, 285 (84.3%) had at least 1 abnormal EGS finding. In 270 of these patients, at least 1 abnormal EGS finding did not result in a diagnosis in the ED and was reported for further workup to subsequent care. During screening, 142 patients (42.0%) had at least 1 diagnosis listed within the 4 EGS domains, significantly more than the 29.3% in the control period (odds ratio 1.75; 95% confidence interval, 1.34-2.29; P<.001). Emergency geriatric screening predicted nursing home admission after the in-hospital stay (odds ratio for ≥3 vs <3 abnormal domains 12.13; 95% confidence interval, 2.79-52.72; P=.001). PRINCIPAL CONCLUSIONS The novel EGS is feasible, identifies previously undetected geriatric problems, and predicts determinants of subsequent care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A number of liquid argon time projection chambers (LAr TPCs) are being built or are proposed for neutrino experiments on long- and short baseline beams. For these detectors, a distortion in the drift field due to geometrical or physics reasons can affect the reconstruction of the events. Depending on the TPC geometry and electric drift field intensity, this distortion could be of the same magnitude as the drift field itself. Recently, we presented a method to calibrate the drift field and correct for these possible distortions. While straight cosmic ray muon tracks could be used for calibration, multiple coulomb scattering and momentum uncertainties allow only a limited resolution. A UV laser instead can create straight ionization tracks in liquid argon, and allows one to map the drift field along different paths in the TPC inner volume. Here we present a UV laser feed-through design with a steerable UV mirror immersed in liquid argon that can point the laser beam at many locations through the TPC. The straight ionization paths are sensitive to drift field distortions, a fit of these distortion to the linear optical path allows to extract the drift field, by using these laser tracks along the whole TPC volume one can obtain a 3D drift field map. The UV laser feed-through assembly is a prototype of the system that will be used for the MicroBooNE experiment at the Fermi National Accelerator Laboratory (FNAL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research on wordhood and morphosyntactic boundness suggests that the domains word and clitic do not lend themselves to cross-linguistic categorization but must be defined language specifically. In most languages, it is necessary to define word on two separate levels, the phonological word (p-word) and the grammatical word (g-word), and to describe mismatches between the two. This paper defines those domains for Garifuna, an Arawak language spoken in Honduras, Central America. Garifuna has auxiliary and classifier constructions which make up two p-words, and only one g-word. P-words made up of more than one g-word involve second position enclitics, word scope clitics, and proclitic connectives and prepositions. Garifuna clitics are typically unstressed, able to attach to hosts of any word class and able to string together into clusters. Enclitics are used to express tense-aspect, modality, and adverbial meanings, among others. In other languages, clitic clusters tend to display a fixed order; Garifuna clitic order seems quite free, although certain orders are preferred. Also, contrary to cross-linguistic tendencies, proclitic connectives can act as hosts for enclitic clusters, contradicting the commonly used definition of clitics as phonologically weak elements that need to attach to a host to form a p-word; such clitic-only p-words are problematic for traditional definitions of clitics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding nuclear and electronic dynamics of molecular systems has advanced considerably by probing their nonlinear responses with a suitable sequence of pulses. Moreover, the ability to control crucial parameters of the excitation pulses, such as duration, sequence, frequency, polarization, slowly varying envelope, or carrier phase, has led to a variety of advanced time-resolved spectroscopic methodologies. Recently, two-dimensional electronic spectroscopy with ultrashort pulses has become a more and more popular tool since it allows to obtain information on energy and coherence transfer phenomena, line broadening mechanisms, or the presence of quantum coherences in molecular complexes. Here, we present a high fidelity two-dimensional electronic spectroscopy setup designed for molecular systems in solution. It incorporates the versatility of pulse-shaping methods to achieve full control on the amplitude and phase of the individual exciting and probing pulses. Selective and precise amplitude- and phase-modulation is shown and applied to investigate electronic dynamics in several reference molecular systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To investigate whether the effects of hybrid iterative reconstruction (HIR) on coronary artery calcium (CAC) measurements using the Agatston score lead to changes in assignment of patients to cardiovascular risk groups compared to filtered back projection (FBP). MATERIALS AND METHODS 68 patients (mean age 61.5 years; 48 male; 20 female) underwent prospectively ECG-gated, non-enhanced, cardiac 256-MSCT for coronary calcium scoring. Scanning parameters were as follows: Tube voltage, 120 kV; Mean tube current time-product 63.67 mAs (50 - 150 mAs); collimation, 2 × 128 × 0.625 mm. Images were reconstructed with FBP and with HIR at all levels (L1 to L7). Two independent readers measured Agatston scores of all reconstructions and assigned patients to cardiovascular risk groups. Scores of HIR and FBP reconstructions were correlated (Spearman). Interobserver agreement and variability was assessed with ĸ-statistics and Bland-Altmann-Plots. RESULTS Agatston scores of HIR reconstructions were closely correlated with FBP reconstructions (L1, R = 0.9996; L2, R = 0.9995; L3, R = 0.9991; L4, R = 0.986; L5, R = 0.9986; L6, R = 0.9987; and L7, R = 0.9986). In comparison to FBP, HIR led to reduced Agatston scores between 97 % (L1) and 87.4 % (L7) of the FBP values. Using HIR iterations L1 - L3, all patients were assigned to identical risk groups as after FPB reconstruction. In 5.4 % of patients the risk group after HIR with the maximum iteration level was different from the group after FBP reconstruction. CONCLUSION There was an excellent correlation of Agatston scores after HIR and FBP with identical risk group assignment at levels 1 - 3 for all patients. Hence it appears that the application of HIR in routine calcium scoring does not entail any disadvantages. Thus, future studies are needed to demonstrate whether HIR is a reliable method for reducing radiation dose in coronary calcium scoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compares monetary and multidimensional poverty measures for the Lao People’s Democratic Republic. Using household data of 2007/2008, we compare the empirical outcomes of the country’s current official monetary poverty measure with those of a multidimensional poverty measure. We analyze which population subgroups are identified as poor by both measures and thus belong to the category of the poorest of the poor; and we look at which subgroups are identified as poor by only one of the measures and belong either to the category of the income-poor (identified as poor only by the monetary measure) or to that of the overlooked poor (identified as poor only by the multidimensional poverty measure). Furthermore, we examined drivers of these differences using a multinomial regression model and found that monetary poverty does not capture the multiple deprivations of ethnic minorities, who are only identified as poor when using a multidimensional poverty measure. We conclude that complementing the monetary poverty measure with a multidimensional poverty index would enable more effective targeting of poverty reduction efforts.