73 resultados para Load analyser
Resumo:
OBJECTIVES: To synthesize the evidence on the risk of HIV transmission through unprotected sexual intercourse according to viral load and treatment with combination antiretroviral therapy (ART). DESIGN: Systematic review and meta-analysis. METHODS: We searched Medline, Embase and conference abstracts from 1996-2009. We included longitudinal studies of serodiscordant couples reporting on HIV transmission according to plasma viral load or use of ART and used random-effects Poisson regression models to obtain summary transmission rates [with 95% confidence intervals, (CI)]. If there were no transmission events we estimated an upper 97.5% confidence limit. RESULTS: We identified 11 cohorts reporting on 5021 heterosexual couples and 461 HIV-transmission events. The rate of transmission overall from ART-treated patients was 0.46 (95% CI 0.19-1.09) per 100 person-years, based on five events. The transmission rate from a seropositive partner with viral load below 400 copies/ml on ART, based on two studies, was zero with an upper 97.5% confidence limit of 1.27 per 100 person-years, and 0.16 (95% CI 0.02-1.13) per 100 person-years if not on ART, based on five studies and one event. There were insufficient data to calculate rates according to the presence or absence of sexually transmitted infections, condom use, or vaginal or anal intercourse. CONCLUSION: Studies of heterosexual discordant couples observed no transmission in patients treated with ART and with viral load below 400 copies/ml, but data were compatible with one transmission per 79 person-years. Further studies are needed to better define the risk of HIV transmission from patients on ART.
Resumo:
BACKGROUND: In high-income countries, viral load is routinely measured to detect failure of antiretroviral therapy (ART) and guide switching to second-line ART. Viral load monitoring is not generally available in resource-limited settings. We examined switching from nonnucleoside reverse transcriptase inhibitor (NNRTI)-based first-line regimens to protease inhibitor-based regimens in Africa, South America and Asia. DESIGN AND METHODS: Multicohort study of 17 ART programmes. All sites monitored CD4 cell count and had access to second-line ART and 10 sites monitored viral load. We compared times to switching, CD4 cell counts at switching and obtained adjusted hazard ratios for switching (aHRs) with 95% confidence intervals (CIs) from random-effects Weibull models. RESULTS: A total of 20 113 patients, including 6369 (31.7%) patients from 10 programmes with access to viral load monitoring, were analysed; 576 patients (2.9%) switched. Low CD4 cell counts at ART initiation were associated with switching in all programmes. Median time to switching was 16.3 months [interquartile range (IQR) 10.1-26.6] in programmes with viral load monitoring and 21.8 months (IQR 14.0-21.8) in programmes without viral load monitoring (P < 0.001). Median CD4 cell counts at switching were 161 cells/microl (IQR 77-265) in programmes with viral load monitoring and 102 cells/microl (44-181) in programmes without viral load monitoring (P < 0.001). Switching was more common in programmes with viral load monitoring during months 7-18 after starting ART (aHR 1.38; 95% CI 0.97-1.98), similar during months 19-30 (aHR 0.97; 95% CI 0.58-1.60) and less common during months 31-42 (aHR 0.29; 95% CI 0.11-0.79). CONCLUSION: In resource-limited settings, switching to second-line regimens tends to occur earlier and at higher CD4 cell counts in ART programmes with viral load monitoring compared with programmes without viral load monitoring.
Resumo:
We used a PCR method to quantify the loads of Chlamydia trachomatis organisms in self-collected urine and vulvovaginal swab (VVS) samples from 93 women and 30 men participating in the Chlamydia Screening Studies Project, a community-based study of individuals not seeking health care. For women, self-collected VVS had a higher mean chlamydial load (10,405 organisms/ml; 95% confidence interval [95% CI], 5,167 to 21,163 organisms/ml) than did first-void urines (FVU) (503 organisms/ml; 95% CI, 250 to 1,022 organisms/ml; P < 0.001). Chlamydial loads in female and male self-collected FVU specimens were similar (P = 0.634). The mean chlamydial load in FVU specimens decreased with increasing age in females and males. There was no strong statistical evidence of differences in chlamydial load in repeat male and female FVU specimens taken when patients attended for treatment a median of 23.5 (range, 14 to 62) and 28 (range, 13 to 132) days later, respectively, or in VVS taken a median of 35 (range, 14 to 217) days later. In this study, chlamydial load values for infected persons in the community who were not seeking treatment were lower than those published in other studies involving symptomatic patients attending clinical settings. This might have implications for estimates of the infectiousness of chlamydia. The results of this study provide a scientific rationale for preferring VVS to FVU specimens from women.
Resumo:
Striated muscle exhibits a pronounced structural-functional plasticity in response to chronic alterations in loading. We assessed the implication of focal adhesion kinase (FAK) signalling in mechano-regulated differentiation of slow-oxidative muscle. Load-dependent consequences of FAK signal modulation were identified using a multi-level approach after electrotransfer of rat soleus muscle with FAK-expression plasmid vs. empty plasmid-transfected contralateral controls. Muscle fibre-targeted over-expression of FAK in anti-gravitational muscle for 9 days up-regulated transcript levels of gene ontologies underpinning mitochondrial metabolism and contraction in the transfected belly portion. Concomitantly, mRNA expression of the major fast-type myosin heavy chain (MHC) isoform, MHC2A, was reduced. The promotion of the slow-oxidative expression programme by FAK was abolished after co-expression of the FAK inhibitor FAK-related non-kinase (FRNK). Elevated protein content of MHC1 (+9%) and proteins of mitochondrial respiration (+165-610%) with FAK overexpression demonstrated the translation of transcript differentiation in targeted muscle fibres towards a slow-oxidative muscle phenotype. Coincidentally MHC2A protein was reduced by 50% due to protection of muscle from de-differentiation with electrotransfer. Fibre cross section in FAK-transfected muscle was elevated by 6%. The FAK-modulated muscle transcriptome was load-dependent and regulated in correspondence to tyrosine 397 phosphorylation of FAK. In the context of overload, the FAK-induced gene expression became manifest at the level of contraction by a slow transformation and the re-establishment of normal muscle force from the lowered levels with transfection. These results highlight the analytic power of a systematic somatic transgene approach by mapping a role of FAK in the dominant mechano-regulation of muscular motor performance via control of gene expression.
Resumo:
INTRODUCTION: It is unclear to which level mean arterial blood pressure (MAP) should be increased during septic shock in order to improve outcome. In this study we investigated the association between MAP values of 70 mmHg or higher, vasopressor load, 28-day mortality and disease-related events in septic shock. METHODS: This is a post hoc analysis of data of the control group of a multicenter trial and includes 290 septic shock patients in whom a mean MAP > or = 70 mmHg could be maintained during shock. Demographic and clinical data, MAP, vasopressor requirements during the shock period, disease-related events and 28-day mortality were documented. Logistic regression models adjusted for the geographic region of the study center, age, presence of chronic arterial hypertension, simplified acute physiology score (SAPS) II and the mean vasopressor load during the shock period was calculated to investigate the association between MAP or MAP quartiles > or = 70 mmHg and mortality or the frequency and occurrence of disease-related events. RESULTS: There was no association between MAP or MAP quartiles and mortality or the occurrence of disease-related events. These associations were not influenced by age or pre-existent arterial hypertension (all P > 0.05). The mean vasopressor load was associated with mortality (relative risk (RR), 1.83; confidence interval (CI) 95%, 1.4-2.38; P < 0.001), the number of disease-related events (P < 0.001) and the occurrence of acute circulatory failure (RR, 1.64; CI 95%, 1.28-2.11; P < 0.001), metabolic acidosis (RR, 1.79; CI 95%, 1.38-2.32; P < 0.001), renal failure (RR, 1.49; CI 95%, 1.17-1.89; P = 0.001) and thrombocytopenia (RR, 1.33; CI 95%, 1.06-1.68; P = 0.01). CONCLUSIONS: MAP levels of 70 mmHg or higher do not appear to be associated with improved survival in septic shock. Elevating MAP >70 mmHg by augmenting vasopressor dosages may increase mortality. Future trials are needed to identify the lowest acceptable MAP level to ensure tissue perfusion and avoid unnecessary high catecholamine infusions.
Resumo:
OBJECTIVES: An article by the Swiss AIDS Commission states that patients with stably suppressed viraemia [i.e. several successive HIV-1 RNA plasma concentrations (viral loads, VL) below the limits of detection during 6 months or more of highly active antiretroviral therapy (HAART)] are unlikely to be infectious. Questions then arise: how reliable is the undetectability of the VL, given the history of measures? What factors determine reliability? METHODS: We assessed the probability (henceforth termed reliability) that the n+1 VL would exceed 50 or 1000 HIV-1 RNA copies/mL when the nth one had been <50 copies/mL in 6168 patients of the Swiss HIV Cohort Study who were continuing to take HAART between 2003 and 2007. General estimating equations were used to analyse potential factors of reliability. RESULTS: With a cut-off at 50 copies/mL, reliability was 84.5% (n=1), increasing to 94.5% (n=5). Compliance, the current type of HAART and the first antiretroviral therapy (ART) received (HAART or not) were predictive factors of reliability. With a cut-off at 1000 copies/mL, reliability was 97.5% (n=1), increasing to 99.1% (n=4). Chart review revealed that patients had stopped their treatment, admitted to major problems with compliance or were taking non-HAART ART in 72.2% of these cases. Viral escape caused by resistance was found in 5.6%. No explanation was found in the charts of 22.2% of cases. CONCLUSIONS: After several successive VLs at <50 copies/mL, reliability reaches approximately 94% with a cut-off of 50 copies/mL and approximately 99% with a cut-off at 1000 copies/mL. Compliance is the most important factor predicting reliability.
Resumo:
Previous studies have suggested that oral or intravenous glucose enhances salt and water retention following a saline load. To test this, we studied the effects of an oral glucose load on urinary sodium and water excretion and serum biochemistry in response to a 2l intravenous infusion of 0.9% saline in normal subjects.
Resumo:
Individual learning is central to the success of the transition phase in software mainte-nance offshoring projects. However, little is known on how learning activities, such as on-the-job training and formal presentations, are effectively combined during the tran-sition phase. In this study, we present and test propositions derived from cognitive load theory. The results of a multiple-case study suggest that learning effectiveness was highest when learning tasks such as authentic maintenance requests were used. Con-sistent with cognitive load theory, learning tasks were most effective when they imposed moderate cognitive load. Our data indicate that cognitive load was influenced by the expertise of the onsite coordinator, by intrinsic task complexity, by the degree of specifi-cation of tasks, and by supportive information. Cultural and semantic distances may in-fluence learning by inhibiting supportive information, specification, and the assignment of learning tasks.
Resumo:
BACKGROUND Monitoring of HIV viral load in patients on combination antiretroviral therapy (ART) is not generally available in resource-limited settings. We examined the cost-effectiveness of qualitative point-of-care viral load tests (POC-VL) in sub-Saharan Africa. DESIGN Mathematical model based on longitudinal data from the Gugulethu and Khayelitsha township ART programmes in Cape Town, South Africa. METHODS Cohorts of patients on ART monitored by POC-VL, CD4 cell count or clinically were simulated. Scenario A considered the more accurate detection of treatment failure with POC-VL only, and scenario B also considered the effect on HIV transmission. Scenario C further assumed that the risk of virologic failure is halved with POC-VL due to improved adherence. We estimated the change in costs per quality-adjusted life-year gained (incremental cost-effectiveness ratios, ICERs) of POC-VL compared with CD4 and clinical monitoring. RESULTS POC-VL tests with detection limits less than 1000 copies/ml increased costs due to unnecessary switches to second-line ART, without improving survival. Assuming POC-VL unit costs between US$5 and US$20 and detection limits between 1000 and 10,000 copies/ml, the ICER of POC-VL was US$4010-US$9230 compared with clinical and US$5960-US$25540 compared with CD4 cell count monitoring. In Scenario B, the corresponding ICERs were US$2450-US$5830 and US$2230-US$10380. In Scenario C, the ICER ranged between US$960 and US$2500 compared with clinical monitoring and between cost-saving and US$2460 compared with CD4 monitoring. CONCLUSION The cost-effectiveness of POC-VL for monitoring ART is improved by a higher detection limit, by taking the reduction in new HIV infections into account and assuming that failure of first-line ART is reduced due to targeted adherence counselling.
Resumo:
OBJECTIVES The aim was to study the impact of the defect size of endodontically treated incisors compared to dental implants as abutments on the survival of zirconia two-unit anterior cantilever-fixed partial dentures (2U-FPDs) during 10-year simulation. MATERIALS AND METHODS Human maxillary central incisors were endodontically treated and divided into three groups (n = 24): I, access cavities rebuilt with composite core; II, teeth decoronated and restored with composite; and III as II supported by fiber posts. In group IV, implants with individual zirconia abutments were used. Specimens were restored with zirconia 2U-FPDs and exposed to two sequences of thermal cycling and mechanical loading. Statistics: Kaplan-Meier; log-rank tests. RESULTS During TCML in group I two tooth fractures and two debondings with chipping were found. Solely chippings occurred in groups II (2×), IV (2×), and III (1×). No significant different survival was found for the different abutments (p = 0.085) or FPDs (p = 0.526). Load capability differed significantly between groups I (176 N) and III (670 N), and III and IV (324 N) (p < 0.024). CONCLUSION Within the limitations of an in vitro study, it can be concluded that zirconia-framework 2U-FPDs on decoronated teeth with/without post showed comparable in vitro reliability as restorations on implants. The results indicated that restorations on teeth with only access cavity perform worse in survival and linear loading. CLINICAL RELEVANCE Even severe defects do not justify per se a replacement of this particular tooth by a dental implant from load capability point of view.