45 resultados para LEAKAGE ERRORS


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The range of patient setup errors in six dimensions detected in clinical routine for cranial as well as for extracranial treatments, were analyzed while performing linear accelerator based stereotactic treatments with frameless patient setup systems. Additionally, the need for re-verification of the patient setup for situations where couch rotations are involved was analyzed for patients treated in the cranial region. METHODS AND MATERIALS A total of 2185 initial (i.e. after pre-positioning the patient with the infrared system but before image guidance) patient setup errors (1705 in the cranial and 480 in the extracranial region) obtained by using ExacTrac (BrainLAB AG, Feldkirchen, Germany) were analyzed. Additionally, the patient setup errors as a function of the couch rotation angle were obtained by analyzing 242 setup errors in the cranial region. Before the couch was rotated, the patient setup error was corrected at couch rotation angle 0° with the aid of image guidance and the six degrees of freedom (6DoF) couch. For both situations attainment rates for two different tolerances (tolerance A: ± 0.5mm, ± 0.5°; tolerance B: ± 1.0 mm, ± 1.0°) were calculated. RESULTS The mean (± one standard deviation) initial patient setup errors for the cranial cases were -0.24 ± 1.21°, -0.23 ± 0.91° and -0.03 ± 1.07° for the pitch, roll and couch rotation axes and 0.10 ± 1.17 mm, 0.10 ± 1.62 mm and 0.11 ± 1.29 mm for the lateral, longitudinal and vertical axes, respectively. Attainment rate (all six axes simultaneously) for tolerance A was 0.6% and 13.1% for tolerance B, respectively. For the extracranial cases the corresponding values were -0.21 ± 0.95°, -0.05 ± 1.08° and -0.14 ± 1.02° for the pitch, roll and couch rotation axes and 0.15 ± 1.77 mm, 0.62 ± 1.94 mm and -0.40 ± 2.15 mm for the lateral, longitudinal and vertical axes. Attainment rate (all six axes simultaneously) for tolerance A was 0.0% and 3.1% for tolerance B, respectively. After initial setup correction and rotation of the couch to treatment position a re-correction has to be performed in 77.4% of all cases to fulfill tolerance A and in 15.6% of all cases to fulfill tolerance B. CONCLUSION The analysis of the data shows that all six axes of a 6DoF couch are used extensively for patient setup in clinical routine. In order to fulfill high patient setup accuracies (e.g. for stereotactic treatments), a 6DoF couch is recommended. Moreover, re-verification of the patient setup after rotating the couch is required in clinical routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to identify common risk factors for patient-reported medical errors across countries. In country-level analyses, differences in risks associated with error between health care systems were investigated. The joint effects of risks on error-reporting probability were modelled for hypothetical patients with different health care utilization patterns. DESIGN Data from the Commonwealth Fund's 2010 lnternational Survey of the General Public's Views of their Health Care System's Performance in 11 Countries. SETTING Representative population samples of 11 countries were surveyed (total sample = 19,738 adults). Utilization of health care, coordination of care problems and reported errors were assessed. Regression analyses were conducted to identify risk factors for patients' reports of medical, medication and laboratory errors across countries and in country-specific models. RESULTS Error was reported by 11.2% of patients but with marked differences between countries (range: 5.4-17.0%). Poor coordination of care was reported by 27.3%. The risk of patient-reported error was determined mainly by health care utilization: Emergency care (OR = 1.7, P < 0.001), hospitalization (OR = 1.6, P < 0.001) and the number of providers involved (OR three doctors = 2.0, P < 0.001) are important predictors. Poor care coordination is the single most important risk factor for reporting error (OR = 3.9, P < 0.001). Country-specific models yielded common and country-specific predictors for self-reported error. For high utilizers of care, the probability that errors are reported rises up to P = 0.68. CONCLUSIONS Safety remains a global challenge affecting many patients throughout the world. Large variability exists in the frequency of patient-reported error across countries. To learn from others' errors is not only essential within countries but may also prove a promising strategy internationally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies of memory-guided saccades in monkeys show an upward bias, while studies of antisaccades in humans show a diagonal effect, a deviation of endpoints toward the 45° diagonal. To determine if these two different spatial biases are specific to different types of saccades, we studied prosaccades, antisaccades and memory-guided saccades in humans. The diagonal effect occurred not with prosaccades but with antisaccades and memory-guided saccades with long intervals, consistent with hypotheses that it originates in computations of goal location under conditions of uncertainty. There was a small upward bias for memory-guided saccades but not prosaccades or antisaccades. Thus this bias is not a general effect of target uncertainty but a property specific to memory-guided saccades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Clinicians involved in medical errors can experience significant distress. This study aims to examine (1) how medical errors impact anaesthesiologists in key work and life domains; (2) anaesthesiologists' attitudes regarding support after errors; (3) and which anaesthesiologists are most affected by errors. METHODS This study is a mailed cross-sectional survey completed by 281 of the 542 clinically active anaesthesiologists (52% response rate) working at Switzerland's five university hospitals between July 2012 and April 2013. RESULTS Respondents reported that errors had negatively affected anxiety about future errors (51%), confidence in their ability as a doctor (45%), ability to sleep (36%), job satisfaction (32%), and professional reputation (9%). Respondents' lives were more likely to be affected as error severity increased. Ninety per cent of respondents disagreed that hospitals adequately support them in coping with the stress associated with medical errors. Nearly all of the respondents (92%) reported being interested in psychological counselling after a serious error, but many identified barriers to seeking counselling. However, there were significant differences between departments regarding error-related stress levels and attitudes about error-related support. Respondents were more likely to experience certain distress if they were female, older, had previously been involved in a serious error, and were dissatisfied with their last error disclosure. CONCLUSION Medical errors, even minor errors and near misses, can have a serious effect on clinicians. Health-care organisations need to do more to support clinicians in coping with the stress associated with medical errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND There is limited research on anaesthesiologists' attitudes and experiences regarding medical error communication, particularly concerning disclosing errors to patients. OBJECTIVE To characterise anaesthesiologists' attitudes and experiences regarding disclosing errors to patients and reporting errors within the hospital, and to examine factors influencing their willingness to disclose or report errors. DESIGN Cross-sectional survey. SETTING Switzerland's five university hospitals' departments of anaesthesia in 2012/2013. PARTICIPANTS Two hundred and eighty-one clinically active anaesthesiologists. MAIN OUTCOME MEASURES Anaesthesiologists' attitudes and experiences regarding medical error communication. RESULTS The overall response rate of the survey was 52% (281/542). Respondents broadly endorsed disclosing harmful errors to patients (100% serious, 77% minor errors, 19% near misses), but also reported factors that might make them less likely to actually disclose such errors. Only 12% of respondents had previously received training on how to disclose errors to patients, although 93% were interested in receiving training. Overall, 97% of respondents agreed that serious errors should be reported, but willingness to report minor errors (74%) and near misses (59%) was lower. Respondents were more likely to strongly agree that serious errors should be reported if they also thought that their hospital would implement systematic changes after errors were reported [(odds ratio, 2.097 (95% confidence interval, 1.16 to 3.81)]. Significant differences in attitudes between departments regarding error disclosure and reporting were noted. CONCLUSION Willingness to disclose or report errors varied widely between hospitals. Thus, heads of department and hospital chiefs need to be aware of the importance of local culture when it comes to error communication. Error disclosure training and improving feedback on how error reports are being used to improve patient safety may also be important steps in increasing anaesthesiologists' communication of errors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Charcoal particles in pollen slides are often abundant, and thus analysts are faced with the problem of setting the minimum counting sum as small as possible in order to save time. We analysed the reliability of charcoal-concentration estimates based on different counting sums, using simulated low-to high-count samples. Bootstrap simulations indicate that the variability of inferred charcoal concentrations increases progressively with decreasing sums. Below 200 items (i.e., the sum of charcoal particles and exotic marker grains), reconstructed fire incidence is either too high or too low. Statistical comparisons show that the means of bootstrap simulations stabilize after 200 counts. Moreover, a count of 200-300 items is sufficient to produce a charcoal-concentration estimate with less than+5% error if compared with high-count samples of 1000 items for charcoal/marker grain ratios 0.1-0.91. If, however, this ratio is extremely high or low (> 0.91 or < 0.1) and if such samples are frequent, we suggest that marker grains are reduced or added prior to new sample processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Leakage is the most common complication of percutaneous cement augmentation of the spine. The viscosity of the polymethylmethacrylate (PMMA) cement is strongly correlated with the likelihood of cement leakage. We hypothesized that cement leakage can be reduced by sequential cement injection in a vertebroplasty model. METHODS A standardized vertebral body substitute model, consisting of aluminum oxide foams coated by acrylic cement with a preformed leakage path, simulating a ventral vein, was developed. Three injection techniques of 6 ml PMMA were assessed: injection in one single step (all-in-one), injection of 1 ml at the first and 5 ml at the second step with 1 min latency in-between (two-step), and sequential injection of 0.5 ml with 1-min latency between the sequences (sequential). Standard PMMA vertebroplasty cement was used; each injection type was tested on ten vertebral body substitute models with two possible leakage paths per model. Leakage was assessed by radiographs using a zonal graduation: intraspongious = no leakage and extracortical = leakage. RESULTS The leakage rate was significantly lower in the "sequential" technique (2/20 leakages) followed by "two-step" (15/20) and "all-in-one" (20/20) techniques (p < 0.001). The RR for a cement leakage was 10.0 times higher in the "all-in-one" compared to the "sequential" group (95 % confidence intervals 2.7-37.2; p < 0.001). CONCLUSIONS The sequential cement injection is a simple approach to minimize the risk for leakage. Taking advantage of the temperature gradient between body and room temperature, it is possible to increase the cement viscosity inside the vertebra while keeping it low in the syringe. Using sequential injection of small cement volumes, further leakage paths are blocked before further injection of the low-viscosity cement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE This study aimed at assessing the cement leakage rate and the filling pattern in patients treated with vertebroplasty, kyphoplasty and stentoplasty with and without a newly developed lavage technique. STUDY DESIGN Retrospective clinical case-control study. METHODS A newly developed bipedicular lavage technique prior to cement application was applied in 64 patients (45.1 %) with 116 vertebrae, ("lavage" group). A conventional bipedicular cement injection technique was used in 78 patients (54.9 %) with 99 levels ("controls"). The outcome measures were filling patterns and leakage rates. RESULTS The overall leakage rate (venous, cortical defect, intradiscal) was 37.9 % in the lavage and 83.8 % in the control group (p < 0.001). Venous leakage (lavage 12.9 % vs. controls 31.3 %; p = 0.001) and cortical defect leakage (lavage 17.2 % vs. controls 63.3 %; p < 0.001) were significantly lower in the lavage group compared to "controls," whereas intradiscal leakages were similar in both groups (lavage 12.1 % vs. controls 15.2 %; p = 0.51). For venous leakage multivariate logistic regression analysis showed lavage to be the only independent predictor. Lavage was associated with 0.33-times (95 % CI 0.16-0.65; p = 0.001) lower likelihood for leakage in compared to controls. CONCLUSIONS Vertebral body lavage prior to cement augmentation is a safe technique to reduce cement leakage in a clinical setting and has the potential to prevent pulmonary fat embolism. Moreover, a better filling pattern can be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies have shown that the discriminability of successive time intervals depends on the presentation order of the standard (St) and the comparison (Co) stimuli. Also, this order affects the point of subjective equality. The first effect is here called the standard-position effect (SPE); the latter is known as the time-order error. In the present study, we investigated how these two effects vary across interval types and standard durations, using Hellström’s sensation-weighting model to describe the results and relate them to stimulus comparison mechanisms. In Experiment 1, four modes of interval presentation were used, factorially combining interval type (filled, empty) and sensory modality (auditory, visual). For each mode, two presentation orders (St–Co, Co–St) and two standard durations (100 ms, 1,000 ms) were used; half of the participants received correctness feedback, and half of them did not. The interstimulus interval was 900 ms. The SPEs were negative (i.e., a smaller difference limen for St–Co than for Co–St), except for the filled-auditory and empty-visual 100-ms standards, for which a positive effect was obtained. In Experiment 2, duration discrimination was investigated for filled auditory intervals with four standards between 100 and 1,000 ms, an interstimulus interval of 900 ms, and no feedback. Standard duration interacted with presentation order, here yielding SPEs that were negative for standards of 100 and 1,000 ms, but positive for 215 and 464 ms. Our findings indicate that the SPE can be positive as well as negative, depending on the interval type and standard duration, reflecting the relative weighting of the stimulus information, as is described by the sensation-weighting model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sentinel-5 (S5) and its precursor (S5P) are future European satellite missions aiming at global monitoring of methane (CH4) column-average dry air mole fractions (XCH4). The spectrometers to be deployed onboard the satellites record spectra of sunlight backscattered from the Earth's surface and atmosphere. In particular, they exploit CH4 absorption in the shortwave infrared spectral range around 1.65 mu m (S5 only) and 2.35 mu m (both S5 and S5P) wavelength. Given an accuracy goal of better than 2% for XCH4 to be delivered on regional scales, assessment and reduction of potential sources of systematic error such as spectroscopic uncertainties is crucial. Here, we investigate how spectroscopic errors propagate into retrieval errors on the global scale. To this end, absorption spectra of a ground-based Fourier transform spectrometer (FTS) operating at very high spectral resolution serve as estimate for the quality of the spectroscopic parameters. Feeding the FTS fitting residuals as a perturbation into a global ensemble of simulated S5- and S5P-like spectra at relatively low spectral resolution, XCH4 retrieval errors exceed 0.6% in large parts of the world and show systematic correlations on regional scales, calling for improved spectroscopic parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The decomposition technique introduced by Blinder (1973) and Oaxaca (1973) is widely used to study outcome differences between groups. For example, the technique is commonly applied to the analysis of the gender wage gap. However, despite the procedure's frequent use, very little attention has been paid to the issue of estimating the sampling variances of the decomposition components. We therefore suggest an approach that introduces consistent variance estimators for several variants of the decomposition. The accuracy of the new estimators under ideal conditions is illustrated with the results of a Monte Carlo simulation. As a second check, the estimators are compared to bootstrap results obtained using real data. In contrast to previously proposed statistics, the new method takes into account the extra variation imposed by stochastic regressors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medial penetration of the helical blade into the hip joint after fixation of trochanteric fractures using the proximal femur nail antirotation (PFN-A) is a potential failure mode. In low demand patients a blade exchange with cement augmentation may be an option if conversion to total hip arthroplasty is unfeasible to salvage the cut-through. This article describes a technique to avoid intraarticular cement leakage using a cement plug to close the defect in the femoral head caused by the cut-through.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leakage from field-grown wheat was investigated during two seasons differing considerably in their rainfall patterns. For all solutes analyzed, these losses were low from non-senescing plant parts, increased after the onset of senescence and became maximal in fully senesced (dry, brown) organs. The cumulative losses of potassium by leakage in the rain were 65% of the content at anthesis for the flag leaf and 95% for the third leaf from the top, while these relative values were lower for magnesium (50 to 80%) and calcium (around 55%) and extremely low for sodium (<10%). The differences between potassium and sodium may be due to a different compartmentation on the tissue level or on the subcellular level. It became evident that for certain nutrients (e.g. potassium or magnesium) leakage in the rain may represent a major loss from senescing leaves and can be a relevant flux in maturing wheat.