Lavage prior to vertebral augmentation reduces the risk for cement leakage
Data(s) |
01/11/2016
|
---|---|
Resumo |
PURPOSE This study aimed at assessing the cement leakage rate and the filling pattern in patients treated with vertebroplasty, kyphoplasty and stentoplasty with and without a newly developed lavage technique. STUDY DESIGN Retrospective clinical case-control study. METHODS A newly developed bipedicular lavage technique prior to cement application was applied in 64 patients (45.1 %) with 116 vertebrae, ("lavage" group). A conventional bipedicular cement injection technique was used in 78 patients (54.9 %) with 99 levels ("controls"). The outcome measures were filling patterns and leakage rates. RESULTS The overall leakage rate (venous, cortical defect, intradiscal) was 37.9 % in the lavage and 83.8 % in the control group (p < 0.001). Venous leakage (lavage 12.9 % vs. controls 31.3 %; p = 0.001) and cortical defect leakage (lavage 17.2 % vs. controls 63.3 %; p < 0.001) were significantly lower in the lavage group compared to "controls," whereas intradiscal leakages were similar in both groups (lavage 12.1 % vs. controls 15.2 %; p = 0.51). For venous leakage multivariate logistic regression analysis showed lavage to be the only independent predictor. Lavage was associated with 0.33-times (95 % CI 0.16-0.65; p = 0.001) lower likelihood for leakage in compared to controls. CONCLUSIONS Vertebral body lavage prior to cement augmentation is a safe technique to reduce cement leakage in a clinical setting and has the potential to prevent pulmonary fat embolism. Moreover, a better filling pattern can be achieved. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/75689/8/Hoppe%20EurSpineJ%202016_p3463.pdf Hoppe, Sven; Elfiky, Tarek; Keel, Marius Johann Baptist; Aghayev, Emin; Ecker, Timo Michael; Benneker, Lorin Michael (2016). Lavage prior to vertebral augmentation reduces the risk for cement leakage. European spine journal, 25(11), pp. 3463-3469. Springer 10.1007/s00586-015-4191-8 <http://dx.doi.org/10.1007/s00586-015-4191-8> doi:10.7892/boris.75689 info:doi:10.1007/s00586-015-4191-8 info:pmid:26275998 urn:issn:0940-6719 |
Idioma(s) |
eng |
Publicador |
Springer |
Relação |
http://boris.unibe.ch/75689/ |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Hoppe, Sven; Elfiky, Tarek; Keel, Marius Johann Baptist; Aghayev, Emin; Ecker, Timo Michael; Benneker, Lorin Michael (2016). Lavage prior to vertebral augmentation reduces the risk for cement leakage. European spine journal, 25(11), pp. 3463-3469. Springer 10.1007/s00586-015-4191-8 <http://dx.doi.org/10.1007/s00586-015-4191-8> |
Palavras-Chave | #610 Medicine & health #360 Social problems & social services |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |