69 resultados para L33 - Comparison of Public and Private Enterprises
Resumo:
BACKGROUND AND PURPOSE: It is unclear whether intraarterial (IAT) or intravenous (IVT) thrombolysis is more effective for ischemic stroke with hyperdense middle cerebral artery sign (HMCAS) on computed tomography (CT). The aim of this study was to compare IAT and IVT in stroke patients with HMCAS. METHODS: Comparison of data from 2 stroke units with similar management of stroke associated with HMCAS, except that 1 unit performed IAT with urokinase and the other IVT with plasminogen activator. Time to treatment was up to 6 hours for IAT and up to 3 hours for IVT. Outcome was measured by mortality and the modified Rankin Scale (mRS), dichotomized at 3 months into favorable (mRS 0 to 2) and unfavorable (mRS 3 to 6). RESULTS: One hundred twelve patients exhibited a HMCAS, 55 of 268 patients treated with IAT and 57 of 249 patients who underwent IVT. Stroke severity at baseline and patient age were similar in both groups. Mean time to treatment was longer in the IAT group (244+/-63 minutes) than in the IVT group (156+/-21 minutes; P=0.0001). However, favorable outcome was more frequent after IAT (n=29, 53%) than after IVT (n=13, 23%; P=0.001), and mortality was lower after IAT (n=4, 7%) than after IVT (n=13, 23%; P=0.022). After multiple regression analysis IAT was associated with a more favorable outcome than IVT (P=0.003) but similar mortality (P=0.192). CONCLUSIONS: In this observational study intraarterial thrombolysis was more beneficial than IVT in the specific group of stroke patients presenting with HMCAS on CT, even though IAT was started later. Our results indicate that a randomized trial comparing both thrombolytic treatments in patients with middle cerebral artery occlusion is warranted.
Resumo:
BACKGROUND: An age-controlled comparison concerning patient satisfaction and electrical performance of microfibres (DTL) and rigid contact lens (Henkes) corneal ERG electrodes was carried out. METHODS: 36 test persons underwent complete ophthalmological examination and were equally distributed into 3 age groups. Electroretinograms were recorded according to ISCEV standards. Randomly, in one eye a Henkes electrode was used and in the other eye a DTL electrode. Amplitudes of a- and b-waves and implicit times were measured and compared for the two electrode types. RESULTS: 34 of 36 test persons preferred DTL electrodes. Electrical performance concerning b-wave amplitudes was comparable. Statistically significant differences were detected only for scotopic combined cone-rod stimulation in the age groups 20 - 40 and 41 - 60 years between the different electrodes. Other recordings did not show differences. A statistically significant reduction of signal amplitudes with age was detected for scotopic isolated rod signals and combined cone-rod signals. Significance level was p < 0.05. No conjunctival or corneal erosions were found after ERG recordings for either electrode. CONCLUSIONS: Electrical performance is comparable between electrodes. For scotopic stimulations age was a significant influencing factor for signal amplitude and should be respected for normative values. DTL electrodes were preferred by the vast majority of patients. No adverse clinical effects were observed for either electrode. DTL electrodes should be preferred due to hygienic reasons (single use) and patient comfort.
Resumo:
OBJECTIVES: Lymph node status is an important prognostic factor in patients with squamous cell carcinoma (SCC) of the vulva. Complete inguinofemoral lymph node dissection (ILND) is accompanied by a high morbidity. Sentinel lymph node biopsy (SLNB) was established for less invasive lymph node (LN) staging. The aim of this study was to evaluate safety of SLNB in terms of accuracy and outcome in a clinical routine setting. METHODS: We retrospectively reviewed the data of patients who underwent SLNB and/or ILND for vulvar SCC in the years 1990-2007. Clinical follow-up was evaluated for histological nodal-negative patients with tumor stage T1 or T2. The false negative rate of SLNB was determined in patients who underwent both SLNB and ILND. RESULTS: Preoperative sentinel lymph node (SLN) visualization by scintigraphy was successful in 95% of all patients. SLNB was false negative in 1/45 inguinae (2.2%). All SLN were detected intraoperatively. During the follow-up period (median 24 months for SLNB and 111 months for ILND), no groin recurrences in initially nodal negative patients occurred (n=34, 59 inguinae). Transient lymph edema occurred in 7/18 patients after ILND (39%) and 2/16 patients (13%) after SLNB. No persistent edemas were found after SLNB and ILND. CONCLUSION: According to our experience SLNB is feasible and accurately predicts LN status of vulvar SCC under clinical routine conditions. SLNB in vulvar cancer seems to be a safe alternative to ILND in order to reduce morbidity of surgical treatment.
Resumo:
OBJECTIVE: Measures to reduce radiation exposure and injected iodine mass are becoming more important with the widespread and often repetitive use of pulmonary CT angiography (CTA) in patients with suspected pulmonary embolism. In this retrospective study, we analyzed the capability of 2 low-kilovoltage CTA-protocols to achieve these goals. MATERIALS AND METHODS: Ninety patients weighing less than 100 kg were examined by a pulmonary CTA protocol using either 100 kVp (group A) or 80 kVp (group B). Volume and flow rate of contrast medium were reduced in group B (75 mL at 3 mL/s) compared with group A (100 mL at 4 mL/s). Attenuation was measured in the central and peripheral pulmonary arteries, and the contrast-to-noise ratios (CNR) were calculated. Entrance skin dose was estimated by measuring the surface dose in an ovoid-cylindrical polymethyl methacrylate chest phantom with 2 various dimensions corresponding to the range of chest diameters in our patients. Quantitative image parameters, estimated effective dose, and skin dose in both groups were compared by the t test. Arterial enhancement, noise, and overall quality were independently assessed by 3 radiologists, and results were compared between the groups using nonparametric tests. RESULTS: Mean attenuation in the pulmonary arteries in group B (427.6 +/- 116 HU) was significantly higher than in group A (342.1 +/- 87.7 HU; P < 0.001), whereas CNR showed no difference (group A, 20.6 +/- 7.3 and group B, 22.2 +/- 7.1; P = 0.302). Effective dose was lower by more than 40% with 80 kVp (1.68 +/- 0.23 mSv) compared with 100 kVp (2.87 +/- 0.88 mSv) (P < 0.001). Surface dose was significantly lower at 80 kVp compared with 100 kVp at both phantom dimensions (2.75 vs. 3.22 mGy; P = 0.027 and 2.22 vs. 2.73 mGy; P = 0.005, respectively). Image quality did not differ significantly between the groups (P = 0.151). CONCLUSIONS: Using 80 kVp in pulmonary CTA permits reduced patient exposure by 40% and CM volume by 25% compared with 100 kVp without deterioration of image quality in patients weighing less than 100 kg.
Resumo:
OBJECTIVE: The objective of this prospective study was to compare the clinical value of procalcitonin (PCT) and C-reactive protein (CrP) plasma concentrations in their postoperative course after decortication. METHODS: Twenty-two patients requiring surgery for pleural empyema were chosen for this prospective study. Routine blood samples including CrP and PCT plasma concentrations were taken before the operation and on the 1st, 2nd, 3rd, and 7th postoperative day. RESULTS: Due to infection PCT and CrP were elevated preoperatively. In the postoperative course both PCT and CrP reached peak-levels on day 2 with values up to 43.55 ng/ml and 384.00 mg/l, respectively. In PCT the rise was followed by a clear decrease in 20 (90.9 %) patients until day 7. In contrast the CrP levels decreased slowly and only seven (54.5%) patients had values of 100 mg/l or below on day 7. PCT showed a better correlation with the clinic in case of septic course than CrP does. CONCLUSIONS: PCT reflects postoperative clinical course more accurately than CrP. Therefore, PCT is a more appropriate laboratory parameter to monitor patients after surgery for pleural empyema.
Resumo:
In diacetylmorphine prescription programs for heavily dependent addicts, diacetylmorphine is usually administered intravenously, but this may not be possible due to venosclerosis or when heroin abuse had occurred via non-intravenous routes. Since up to 25% of patients administer diacetylmorphine orally, we characterised morphine absorption after single oral doses of immediate and extended release diacetylmorphine in 8 opioid addicts. Plasma concentrations were determined by liquid chromatography-mass spectrometry. Non-compartmental methods and deconvolution were applied for data analysis. Mean (+/-S.D.) immediate and extended release doses were 719+/-297 and 956+/-404 mg, with high absolute morphine bioavailabilities of 56-61%, respectively. Immediate release diacetylmorphine caused rapid morphine absorption, peaking at 10-15 min. Morphine absorption was considerably slower and more sustained for extended release diacetylmorphine, with only approximately 30% of maximal immediate release absorption being reached after 10 min and maintained for 3-4h, with no relevant food interaction. The relative extended to immediate release bioavailability was calculated to be 86% by non-compartmental analysis and 93% by deconvolution analysis. Thus, immediate and extended release diacetylmorphine produce the intended morphine exposures. Both are suitable for substitution treatments. Similar doses can be applied if used in combination or sequentially.
Resumo:
In this paper we compare the performance of two image classification paradigms (object- and pixel-based) for creating a land cover map of Asmara, the capital of Eritrea and its surrounding areas using a Landsat ETM+ imagery acquired in January 2000. The image classification methods used were maximum likelihood for the pixel-based approach and Bhattacharyya distance for the object-oriented approach available in, respectively, ArcGIS and SPRING software packages. Advantages and limitations of both approaches are presented and discussed. Classifications outputs were assessed using overall accuracy and Kappa indices. Pixel- and object-based classification methods result in an overall accuracy of 78% and 85%, respectively. The Kappa coefficient for pixel- and object-based approaches was 0.74 and 0.82, respectively. Although pixel-based approach is the most commonly used method, assessment and visual interpretation of the results clearly reveal that the object-oriented approach has advantages for this specific case-study.
Resumo:
Multilocus sequence typing (MLST) and antibiotic resistance patterns of Campylobacter jejuni and Campylobacter coli from retail chicken meat showed high overlap with isolates collected at slaughterhouses, indicating little selection along the production chain. They also showed significant common sequence types with human clinical isolates, revealing chicken meat as a likely source for human infection.
Resumo:
The extents of functional surfaces (villi, microvilli) have been estimated at different longitudinal sites, and in the entire small intestine, for three species of bats belonging to two feeding groups: insect- and fruit-eaters. In all species, surface areas and other structural quantities tended to be greatest at more cranial sites and to decline caudally. The entomophagous bat (Miniopterus inflatus) had a mean body mass (coefficient of variation) of 8.9 g (5%) and a mean intestinal length of 20 cm (6%). The surface area of the basic intestinal tube (primary mucosa) was 9.1 cm2 (10%) but this was amplified to 48 cm2 (13%) by villi and to 0.13 m2 (20%) by microvilli. The total number of microvilli per intestine was 4 x 10(11) (20%). The average microvillus had a diameter of 8 nm (10%), a length of 1.1 microns (22%) and a membrane surface area of 0.32 micron 2 (31%). In two species of fruit bats (Epomophorus wahlbergi and Lisonycteris angolensis), body masses were greater and intestines longer, the values being 76.0 g (18%) and 76.9 g (4%), and 73 cm (16%) and 72 cm (7%), respectively. Surface areas were also greater, amounting to 76 cm2 (26%) and 45 cm2 (8%) for the primary mucosa, 547 cm2 (29%) and 314 cm2 (16%) for villi and 2.7 m2 (23%) and 1.5 m2 (18%) for microvilli. An increase in the number of microvilli, 33 x 10(11) (19%) and 15 x 10(11) (24%) per intestine, contributed to the more extensive surface area but there were concomitant changes in the dimensions of microvilli. Mean diameters were 94 nm (8%) and 111 nm (4%), and mean lengths were 2.8 microns (12%) and 2.9 microns (10%), respectively. Thus, an increase in the surface area of the average microvillus to 0.83 micron 2 (12%) and 1.02 microns 2 (11%) also contributed to the greater total surface area of microvilli. The lifestyle-related differences in total microvillous surface areas persisted when structural quantities were normalised for the differences in body masses. The values for total microvillous surface area were 148 cm2g-1 (20%) in the entomophagous bat, 355 cm2g-1 (20%) in E. wahlbergi and 192 cm2g-1 (17%) in L. angolensis. This was true despite the fact that the insecteater possessed a greater length of intestine per unit of body mass: 22 mm g-1 (8%) versus 9-10 mm g-1 (9-10%) for the fruit-eaters.
Resumo:
The importance of direct and indirect alcohol markers to evaluate alcohol consumption in clinical and forensic settings is increasingly recognized. While some markers are used to prove abstinence from ethanol, other markers are suitable for detection of alcohol misuse. Phosphatidyl ethanol (PEth) is ranked among the latter. There is only little information about the correlation between PEth and other currently used markers (ethyl glucuronide, ethyl sulfate, carbohydrate deficient transferrin, gamma-glutamyl transpeptidase, and methanol) and about their decline during detoxification. To get more information, 18 alcohol-dependent patients in withdrawal therapy were monitored for These parameters in blood and urine for up to 19 days. There was no correlation between the different markers. PEth showed a rapid decrease at the beginning of the intervention, a slow decline after the first few days, and could still be detected after 19 days of abstinence from ethanol.