55 resultados para Image-based control


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: In contrast to hypnosis, there is no surrogate parameter for analgesia in anesthetized patients. Opioids are titrated to suppress blood pressure response to noxious stimulation. The authors evaluated a novel model predictive controller for closed-loop administration of alfentanil using mean arterial blood pressure and predicted plasma alfentanil concentration (Cp Alf) as input parameters. METHODS: The authors studied 13 healthy patients scheduled to undergo minor lumbar and cervical spine surgery. After induction with propofol, alfentanil, and mivacurium and tracheal intubation, isoflurane was titrated to maintain the Bispectral Index at 55 (+/- 5), and the alfentanil administration was switched from manual to closed-loop control. The controller adjusted the alfentanil infusion rate to maintain the mean arterial blood pressure near the set-point (70 mmHg) while minimizing the Cp Alf toward the set-point plasma alfentanil concentration (Cp Alfref) (100 ng/ml). RESULTS: Two patients were excluded because of loss of arterial pressure signal and protocol violation. The alfentanil infusion was closed-loop controlled for a mean (SD) of 98.9 (1.5)% of presurgery time and 95.5 (4.3)% of surgery time. The mean (SD) end-tidal isoflurane concentrations were 0.78 (0.1) and 0.86 (0.1) vol%, the Cp Alf values were 122 (35) and 181 (58) ng/ml, and the Bispectral Index values were 51 (9) and 52 (4) before surgery and during surgery, respectively. The mean (SD) absolute deviations of mean arterial blood pressure were 7.6 (2.6) and 10.0 (4.2) mmHg (P = 0.262), and the median performance error, median absolute performance error, and wobble were 4.2 (6.2) and 8.8 (9.4)% (P = 0.002), 7.9 (3.8) and 11.8 (6.3)% (P = 0.129), and 14.5 (8.4) and 5.7 (1.2)% (P = 0.002) before surgery and during surgery, respectively. A post hoc simulation showed that the Cp Alfref decreased the predicted Cp Alf compared with mean arterial blood pressure alone. CONCLUSION: The authors' controller has a similar set-point precision as previous hypnotic controllers and provides adequate alfentanil dosing during surgery. It may help to standardize opioid dosing in research and may be a further step toward a multiple input-multiple output controller.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

2D-3D registration of pre-operative 3D volumetric data with a series of calibrated and undistorted intra-operative 2D projection images has shown great potential in CT-based surgical navigation because it obviates the invasive procedure of the conventional registration methods. In this study, a recently introduced spline-based multi-resolution 2D-3D image registration algorithm has been adapted together with a novel least-squares normalized pattern intensity (LSNPI) similarity measure for image guided minimally invasive spine surgery. A phantom and a cadaver together with their respective ground truths were specially designed to experimentally assess possible factors that may affect the robustness, accuracy, or efficiency of the registration. Our experiments have shown that it is feasible for the assessed 2D-3D registration algorithm to achieve sub-millimeter accuracy in a realistic setup in less than one minute.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a novel variable decomposition approach for pose recovery of the distal locking holes using single calibrated fluoroscopic image. The problem is formulated as a model-based optimal fitting process, where the control variables are decomposed into two sets: (a) the angle between the nail axis and its projection on the imaging plane, and (b) the translation and rotation of the geometrical model of the distal locking hole around the nail axis. By using an iterative algorithm to find the optimal values of the latter set of variables for any given value of the former variable, we reduce the multiple-dimensional model-based optimal fitting problem to a one-dimensional search along a finite interval. We report the results of our in vitro experiments, which demonstrate that the accuracy of our approach is adequate for successful distal locking of intramedullary nails.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. METHODS AND MATERIALS: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. RESULTS: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). CONCLUSIONS: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: In order to use a single implant with one treatment plan in fractionated high-dose-rate brachytherapy (HDR-B), applicator position shifts must be corrected prior to each fraction. The authors investigated the use of gold markers for X-ray-based setup and position control between the single fractions. PATIENTS AND METHODS: Caudad-cephalad movement of the applicators prior to each HDR-B fraction was determined on radiographs using two to three gold markers, which had been inserted into the prostate as intraprostatic reference, and one to two radiopaque-labeled reference applicators. 35 prostate cancer patients, treated by HDR-B as a monotherapy between 10/2003 and 06/2006 with four fractions of 9.5 Gy each, were analyzed. Toxicity was scored according to the CTCAE Score, version 3.0. Median follow-up was 3 years. RESULTS: The mean change of applicators positions compared to baseline varied substantially between HDR-B fractions, being 1.4 mm before fraction 1 (range, -4 to 2 mm), -13.1 mm before fraction 2 (range, -36 to 0 mm), -4.1 mm before fraction 3 (range, -21 to 9 mm), and -2.6 mm at fraction 4 (range, -16 to 9 mm). The original position of the applicators could be readjusted easily prior to each fraction in every patient. In 18 patients (51%), the applicators were at least once readjusted > 10 mm, however, acute or late grade > or = 2 genitourinary toxicity was not increased (p = 1.0) in these patients. CONCLUSION: Caudad position shifts up to 36 mm were observed. Gold markers represent a valuable tool to ensure setup accuracy and precise dose delivery in fractionated HDR-B monotherapy of prostate cancer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, an Insulin Infusion Advisory System (IIAS) for Type 1 diabetes patients, which use insulin pumps for the Continuous Subcutaneous Insulin Infusion (CSII) is presented. The purpose of the system is to estimate the appropriate insulin infusion rates. The system is based on a Non-Linear Model Predictive Controller (NMPC) which uses a hybrid model. The model comprises a Compartmental Model (CM), which simulates the absorption of the glucose to the blood due to meal intakes, and a Neural Network (NN), which simulates the glucose-insulin kinetics. The NN is a Recurrent NN (RNN) trained with the Real Time Recurrent Learning (RTRL) algorithm. The output of the model consists of short term glucose predictions and provides input to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. For the development and the evaluation of the IIAS, data generated from a Mathematical Model (MM) of a Type 1 diabetes patient have been used. The proposed control strategy is evaluated at multiple meal disturbances, various noise levels and additional time delays. The results indicate that the implemented IIAS is capable of handling multiple meals, which correspond to realistic meal profiles, large noise levels and time delays.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Quantitative characterisation of carotid atherosclerosis and classification into symptomatic or asymptomatic is crucial in planning optimal treatment of atheromatous plaque. The computer-aided diagnosis (CAD) system described in this paper can analyse ultrasound (US) images of carotid artery and classify them into symptomatic or asymptomatic based on their echogenicity characteristics. The CAD system consists of three modules: a) the feature extraction module, where first-order statistical (FOS) features and Laws' texture energy can be estimated, b) the dimensionality reduction module, where the number of features can be reduced using analysis of variance (ANOVA), and c) the classifier module consisting of a neural network (NN) trained by a novel hybrid method based on genetic algorithms (GAs) along with the back propagation algorithm. The hybrid method is able to select the most robust features, to adjust automatically the NN architecture and to optimise the classification performance. The performance is measured by the accuracy, sensitivity, specificity and the area under the receiver-operating characteristic (ROC) curve. The CAD design and development is based on images from 54 symptomatic and 54 asymptomatic plaques. This study demonstrates the ability of a CAD system based on US image analysis and a hybrid trained NN to identify atheromatous plaques at high risk of stroke.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE Patients with Alzheimer's disease (AD) have an increased risk of developing seizures or epilepsy. Little is known about the role of risk factors and about the risk of developing seizures/epilepsy in patients with vascular dementia (VD). The aim of this study was to assess incidence rates (IRs) of seizures/epilepsy in patients with AD, VD, or without dementia, and to identify potential risk factors of seizures or epilepsy. METHODS We conducted a follow-up study with a nested case-control analysis using the United Kingdom-based General Practice Research Database (GPRD). We identified patients aged ≥65 years with an incident diagnosis of AD or VD between 1998 and 2008 and a matched comparison group of dementia-free patients. Conditional logistic regression was used to estimate the odds ratio (OR) with a 95% confidence interval (CI) of developing seizures/epilepsy in patients with AD or VD, stratified by age at onset and duration of dementia as well as by use of antidementia drugs. KEY FINDINGS Among 7,086 cases with AD, 4,438 with VD, and 11,524 matched dementia-free patients, we identified 180 cases with an incident diagnosis of seizures/epilepsy. The IRs of epilepsy/seizures for patients with AD or VD were 5.6/1,000 person-years (py) (95% CI 4.6-6.9) and 7.5/1,000 py (95% CI 5.7-9.7), respectively, and 0.8/1,000 py (95% CI 0.6-1.1) in the dementia-free group. In the nested case-control analysis, patients with longer standing (≥3 years) AD had a slightly higher risk of developing seizures or epilepsy than those with a shorter disease duration, whereas in patients with VD the contrary was observed. SIGNIFICANCE Seizures or epilepsy were substantially more common in patients with AD and VD than in dementia-free patients. The role of disease duration as a risk factor for seizures/epilepsy seems to differ between AD and VD.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES It is still debated if pre-existing minority drug-resistant HIV-1 variants (MVs) affect the virological outcomes of first-line NNRTI-containing ART. METHODS This Europe-wide case-control study included ART-naive subjects infected with drug-susceptible HIV-1 as revealed by population sequencing, who achieved virological suppression on first-line ART including one NNRTI. Cases experienced virological failure and controls were subjects from the same cohort whose viraemia remained suppressed at a matched time since initiation of ART. Blinded, centralized 454 pyrosequencing with parallel bioinformatic analysis in two laboratories was used to identify MVs in the 1%-25% frequency range. ORs of virological failure according to MV detection were estimated by logistic regression. RESULTS Two hundred and sixty samples (76 cases and 184 controls), mostly subtype B (73.5%), were used for the analysis. Identical MVs were detected in the two laboratories. 31.6% of cases and 16.8% of controls harboured pre-existing MVs. Detection of at least one MV versus no MVs was associated with an increased risk of virological failure (OR = 2.75, 95% CI = 1.35-5.60, P = 0.005); similar associations were observed for at least one MV versus no NRTI MVs (OR = 2.27, 95% CI = 0.76-6.77, P = 0.140) and at least one MV versus no NNRTI MVs (OR = 2.41, 95% CI = 1.12-5.18, P = 0.024). A dose-effect relationship between virological failure and mutational load was found. CONCLUSIONS Pre-existing MVs more than double the risk of virological failure to first-line NNRTI-based ART.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE Use of diuretics has been associated with an increased risk of gout. Data on different types of diuretics are scarce. We undertook this study to investigate the association between use of loop diuretics, thiazide or thiazide-like diuretics, and potassium-sparing agents and the risk of developing incident gout. METHODS We conducted a retrospective population-based case-control analysis using the General Practice Research Database established in the UK. We identified case patients who were diagnosed as having incident gout between 1990 and 2010. One control patient was matched to each case patient for age, sex, general practice, calendar time, and years of active history in the database. We used conditional logistic regression to calculate odds ratios (ORs) and 95% confidence intervals (95% CIs), and we adjusted for potential confounders. RESULTS We identified 91,530 incident cases of gout and the same number of matched controls. Compared to past use of diuretics from each respective drug class, adjusted ORs for current use of loop diuretics, thiazide diuretics, thiazide-like diuretics, and potassium-sparing diuretics were 2.64 (95% CI 2.47-2.83), 1.70 (95% CI 1.62-1.79), 2.30 (95% CI 1.95-2.70), and 1.06 (95% CI 0.91-1.23), respectively. Combined use of loop diuretics and thiazide diuretics was associated with the highest relative risk estimates of gout (adjusted OR 4.65 [95% CI 3.51-6.16]). Current use of calcium channel blockers or losartan slightly attenuated the risk of gout in patients who took diuretics. CONCLUSION Use of loop diuretics, thiazide diuretics, and thiazide-like diuretics was associated with an increased risk of incident gout, although use of potassium-sparing agents was not.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to explore the risk of incident gout in patients with type 2 diabetes mellitus (T2DM) in association with diabetes duration, diabetes severity and antidiabetic drug treatment. METHODS We conducted a case-control study in patients with T2DM using the UK-based Clinical Practice Research Datalink (CPRD). We identified case patients aged ≥18 years with an incident diagnosis of gout between 1990 and 2012. We matched to each case patient one gout-free control patient. We used conditional logistic regression analysis to calculate adjusted ORs (adj. ORs) with 95% CIs and adjusted our analyses for important potential confounders. RESULTS The study encompassed 7536 T2DM cases with a first-time diagnosis of gout. Compared to a diabetes duration <1 year, prolonged diabetes duration (1-3, 3-6, 7-9 and ≥10 years) was associated with decreased adj. ORs of 0.91 (95% CI 0.79 to 1.04), 0.76 (95% CI 0.67 to 0.86), 0.70 (95% CI 0.61 to 0.86), and 0.58 (95% CI 0.51 to 0.66), respectively. Compared to a reference A1C level of <7%, the risk estimates of increasing A1C levels (7.0-7.9, 8.0-8.9 and ≥9%) steadily decreased with adj. ORs of 0.79 (95% CI 0.72 to 0.86), 0.63 (95% CI 0.55 to 0.72), and 0.46 (95% CI 0.40 to 0.53), respectively. Neither use of insulin, metformin, nor sulfonylureas was associated with an altered risk of incident gout. CONCLUSIONS Increased A1C levels, but not use of antidiabetic drugs, was associated with a decreased risk of incident gout among patients with T2DM.