182 resultados para Chest


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In modern medico-legal literature, only a small number of publications deal with fatal injuries from black powder guns. Most of them focus on the morphological features such as intense soot soiling, blast tattooing and burn effects in close-range shots or describe the wound ballistics of spherical lead bullets. Another kind of "unusual" and potentially lethal weapons are handguns destined for firing only blank cartridges such as starter and alarm pistols. The dangerousness of these guns is restricted to very close and contact range shots and results from the gas jet produced by the deflagration of the propellant. The present paper reports on a suicide committed with a muzzle-loading percussion pistol cal. 45. An unusually large stellate entrance wound was located in the precordial region, accompanied by an imprint mark from the ramrod and a faint greenish discoloration (apparently due to the formation of sulfhemoglobin). Autopsy revealed an oversized powder cavity, multiple fractures of the anterior thoracic wall as well as ruptures of the heart, the aorta, the left hepatic lobe and the diaphragm. In total, the zone of mechanical destruction had a diameter of approx. 15 cm. As there was no exit wound and no bullet lodged in the body, the injury was caused exclusively by the inrushing combustion gases of the propellant (black powder) comparable with the gas jet of a blank cartridge gun. In contact shots to ballistic gelatine using the suicide's pistol loaded with black powder but no projectile, the formation of a nearly spherical cavity could be demonstrated by means of a high-speed camera. The extent of the temporary cavity after firing with 5 g of black powder roughly corresponded to the zone of destruction found in the suicide's body.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a rare case of pulmonary intimal sarcoma mimicking pulmonary embolism in a 40-year-old woman. Although extremely rare, these tumors must be considered in patients who present inappropriate imaging findings that suggest embolism. Chest computed tomography is the modality of choice to determine the extent of the tumor. We present a female patient with suspected embolism that was in fact found to be an endothelial sarcoma of the pulmonary arteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. MATERIALS AND METHODS We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. RESULTS A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1% ± 2.2% versus 85.6% ± 5.6% (p = 0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7% ± 8.1% (with bone suppression, 46.1% ± 8%; p = 0.94); for microdose CT, nodule sensitivity was 83.6% ± 9% without MIP (with additional MIP, 92.5% ± 6%; p < 10(-3)). Individual sensitivities of microdose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (p < 10(-6)). The effective dose for chest radiography including dual-energy subtraction was 0.242 mSv; for microdose CT, the applied dose was 0.1323 mSv. CONCLUSION Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Abnormal ECG findings suggestive of cardiac disease are frequent in patients with funnel chest, although structural heart disease is rare. Electrocardiographic characteristics and changes following new surgical treatments in young adults are not described so far. The aim of the study was to analyze electrocardiographic characteristics of patients with funnel chest before and after minimally invasive funnel chest correction by the Nuss procedure. METHODS Twenty-six patients with surgical correction of funnel chest using pectus bar were included. Twelve-lead ECGs before and later than one year after surgery were analyzed. RESULTS In postoperative ECGs, amplitude of P wave in lead II and negative terminal amplitude of P wave in lead V1 decreased from 0.13 to 0.10mV (p=0.03), and from 0.10 to 0.04mV (p<0.001), respectively. Mean QRS duration decreased from 108ms to 98ms (p=0.003) after correction. A pathological left and right Sokolow-Lyon index was observed in 35% and 23% of patients before, versus 8% (p=0.04) and 0% (p=0.01) after correction, respectively. In contrast, the rate of patients with J wave pattern in precordial leads V4-V6 increased from 8% before to 42% after surgery (p=0.004). CONCLUSIONS ECG abnormalities in patients with funnel chest are frequent, and can normalize after surgical correction by the Nuss procedure. De novo J wave pattern in precordial leads V4-V6 is a frequent finding after surgical funnel chest correction using pectus bar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic mountain sickness (CMS) is an important public health problem and is characterized by exaggerated hypoxemia, erythrocytosis, and pulmonary hypertension. While pulmonary hypertension is a leading cause of morbidity and mortality in patients with CMS, it is relatively mild and its underlying mechanisms are not known. We speculated that during mild exercise associated with daily activities, pulmonary hypertension in CMS is much more pronounced.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Acute coronary syndromes (ACS) in very young patients have been poorly described. We therefore evaluate ACS in patients aged 35 years and younger. Methods: In this prospective cohort study, 76 hospitals treating ACS in Switzerland enrolled 28,778 patients with ACS between January 1, 1997, and October 1, 2008. ACS definition included ST-segment elevation myocardial infarction (STEMI), non-ST-segment elevation myocardial infarction (NSTEMI), and unstable angina (UA). Results: 195 patients (0.7%) were 35 years old or younger. Compared to patients N35 years, these patients were more likely to present with chest pain (91.6% vs. 83.7%; P=0.003) and less likely to have heart failure (Killip class II to IV in 5.2% vs. 23.0%; Pb0.001). STEMI was more prevalent in younger than in older patients (73.1% vs. 58.3%; Pb0.001). Smoking, family history of CAD, and/or dyslipidemia were important cardiovascular risk factors in young patients (prevalence 77.2%, 55.0%, and 44.0%). The prevalence of overweight among young patients with ACS was high (57.8%). Cocaine abuse was associated with ACS in some young patients. Compared to older patients, young patients were more likely to receive early percutaneous coronary interventions and had better outcome with fewer major adverse cardiac events. Conclusions: Young patients with ACS differed from older patients in that the younger often presented with STEMI, received early aggressive treatment, and had favourable outcomes. Primary prevention of smoking, dyslipidemia and overweight should be more aggressively promoted in adolescence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Several adverse consequences are caused by mild perioperative hypothermia. Maintaining normothermia with patient warming systems, today mostly with forced air (FA), has thus become a standard procedure during anesthesia. Recently, a polymer-based resistive patient warming system was developed. We compared the efficacy of a widely distributed FA system with the resistive-polymer (RP) system in a prospective, randomized clinical study. METHODS: Eighty patients scheduled for orthopedic surgery were randomized to either FA warming (Bair Hugger warming blanket #522 and blower #750, Arizant, Eden Prairie, MN) or RP warming (Hot Dog Multi-Position Blanket and Hot Dog controller, Augustine Biomedical, Eden Prairie, MN). Core temperature, skin temperature (head, upper and lower arm, chest, abdomen, back, thigh, and calf), and room temperature (general and near the patient) were recorded continuously. RESULTS: After an initial decrease, core temperatures increased in both groups at comparable rates (FA: 0.33 degrees C/h +/- 0.34 degrees C/h; RP: 0.29 degrees C/h +/- 0.35 degrees C/h; P = 0.6). There was also no difference in the course of mean skin and mean body (core) temperature. FA warming increased the environment close to the patient (the workplace of anesthesiologists and surgeons) more than RP warming (24.4 degrees C +/- 5.2 degrees C for FA vs 22.6 degrees C +/- 1.9 degrees C for RP at 30 minutes; P(AUC) <0.01). CONCLUSION: RP warming performed as efficiently as FA warming in patients undergoing orthopedic surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spontaneous pneumomediastinum is an uncommon benign condition that is occasionally associated with air within the spinal canal. We describe a further case in a 14-year-old girl and suggest a classification system based on a detailed review of the previous literature. Forty-eight patients with spontaneous pneumomediastinum and intraspinal air accumulation (36 men and 12 women, age range 4-72 years, median age 18 years) were grouped into those with underlying lung disease (n = 13), those with other underlying etiologic factors (n = 22), and those arising spontaneously (n = 13). Neurologic symptoms or signs were noted in one case. The remaining cases were successfully managed conservatively. In spontaneous pneumomediastinum, accumulation of air within the spinal canal is self-limiting and benign. The same management is advised in spontaneous pneumomediastinum with and without intraspinal air accumulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To identify the occurrence, types, and severity of associated injuries outside the facial region among patients diagnosed with facial fractures, and to analyze whether there are any factors related to associated injuries. MATERIALS AND METHODS: This was a cross-sectional study of 401 patients diagnosed with facial fractures during the 2-year period from 2003 to 2004. RESULTS: Associated injuries were observed in 101 patients (25.2%). The most common type of injury was a limb injury (13.5%), followed by brain (11.0%), chest (5.5%), spine (2.7%), and abdominal (0.8%) injuries. Multiple associated injuries were observed in 10% and polytrauma in 7.5%. The mortality rate was 0.2%. The occurrence of associated injury correlated significantly with trauma mechanism and fracture type; high-speed accidents and severe facial fractures were significant predictors of associated injury. CONCLUSIONS: Associated injuries are frequent among patients who have sustained facial fractures. The results underscore the importance of multiprofessional collaboration in diagnosis and sequencing of treatment, but also the importance of arranging appropriate clinical rotations for maxillofacial residents in training.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The inflammatory myofibroblastic tumour of the lung is considered a rare diagnosis of lung masses. We report the case of a five-year-old girl who presented with recurrent pyrexia, dry cough, and shortness of breath. Chest X-ray and computed tomography showed a total atelectasis of the left lower lobe and a segmental atelectasis of the left upper lobe. The mass was removed in toto, histopathology revealed the diagnosis of an inflammatory myofibroblastic tumour of the lung. The patient is without any signs of relapse 30 months after surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Non-contrast post-mortem computed tomography (pm-CT) is useful in the evaluation of bony pathologies, whereas minimally invasive pm-CT-angiography allows for the detection of subtle vascular lesions. We present a case of an accidentally self-inflicted fatal bullet wound to the chest where pm-CT-angiography revealed a small laceration of the anterior interventricular branch of the left coronary artery and a tiny disruption of the right ventricle with pericardial and pleural effusion. Subsequent autopsy confirmed our radiological findings. Post-mortem CT-angiography has a great potential for the detection of vascular lesions and can be considered equivalent to autopsy for selected cases in forensic medicine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neurally adjusted ventilatory assist (NAVA) delivers airway pressure (Paw) in proportion to neural inspiratory drive as reflected by electrical activity of the diaphragm (EAdi). Changing positive end-expiratory pressure (PEEP) impacts respiratory muscle load and function and, hence, EAdi. We aimed to evaluate how PEEP affects the breathing pattern and neuroventilatory efficiency during NAVA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this article is to disclose the characteristics of postmortem forensic imaging; give an overview of the several possible findings in postmortem imaging, which are uncommon or new to clinical radiologists; and discuss the possible pitfalls. Unspecific postmortem signs are enlisted and specific signs shall be presented, which are typical for one cause of death. Unspecific signs. Livor mortis may not only be seen from the outside, but also inside the body in the lungs: in chest CT internal livor mortis appear as ground glass opacity in the dependent lower lobes. The aortic wall is often hyperdense in postmortem CT due to wall contraction and loss of luminal pressure. Gas bubbles are very common postmortem due to systemic gas embolism after major open trauma, artificial respiration or initial decomposition; in particular putrefaction produces gas bubbles globally. Specific signs. Intracranial bleeding is hyperattenuating both in radiology and in postmortem imaging. Signs of strangulation are hemorrhage in the soft tissue of the neck like skin, subcutaneous tissue, platysma muscle and lymph nodes. The "vanishing" aorta is indicative for exsanguination. Fluid in the airways with mosaic lung densities and emphysema (aquosum) is typical for fresh-water drowning.