64 resultados para Brett Horton
Resumo:
BACKGROUND: Unlike most antihyperglycaemic drugs, glucagon-like peptide-1 (GLP-1) receptor agonists have a glucose-dependent action and promote weight loss. We compared the efficacy and safety of liraglutide, a human GLP-1 analogue, with exenatide, an exendin-based GLP-1 receptor agonist. METHODS: Adults with inadequately controlled type 2 diabetes on maximally tolerated doses of metformin, sulphonylurea, or both, were stratified by previous oral antidiabetic therapy and randomly assigned to receive additional liraglutide 1.8 mg once a day (n=233) or exenatide 10 microg twice a day (n=231) in a 26-week open-label, parallel-group, multinational (15 countries) study. The primary outcome was change in glycosylated haemoglobin (HbA(1c)). Efficacy analyses were by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT00518882. FINDINGS: Mean baseline HbA(1c) for the study population was 8.2%. Liraglutide reduced mean HbA(1c) significantly more than did exenatide (-1.12% [SE 0.08] vs -0.79% [0.08]; estimated treatment difference -0.33; 95% CI -0.47 to -0.18; p<0.0001) and more patients achieved a HbA(1c) value of less than 7% (54%vs 43%, respectively; odds ratio 2.02; 95% CI 1.31 to 3.11; p=0.0015). Liraglutide reduced mean fasting plasma glucose more than did exenatide (-1.61 mmol/L [SE 0.20] vs -0.60 mmol/L [0.20]; estimated treatment difference -1.01 mmol/L; 95% CI -1.37 to -0.65; p<0.0001) but postprandial glucose control was less effective after breakfast and dinner. Both drugs promoted similar weight losses (liraglutide -3.24 kg vs exenatide -2.87 kg). Both drugs were well tolerated, but nausea was less persistent (estimated treatment rate ratio 0.448, p<0.0001) and minor hypoglycaemia less frequent with liraglutide than with exenatide (1.93 vs 2.60 events per patient per year; rate ratio 0.55; 95% CI 0.34 to 0.88; p=0.0131; 25.5%vs 33.6% had minor hypoglycaemia). Two patients taking both exenatide and a sulphonylurea had a major hypoglycaemic episode. INTERPRETATION: Liraglutide once a day provided significantly greater improvements in glycaemic control than did exenatide twice a day, and was generally better tolerated. The results suggest that liraglutide might be a treatment option for type 2 diabetes, especially when weight loss and risk of hypoglycaemia are major considerations.
Resumo:
Delivering cochlear implants through a minimally invasive tunnel (1.8 mm in diameter) from the mastoid surface to the inner ear is referred to as direct cochlear access (DCA). Based on cone beam as well as micro-computed tomography imaging, this in vitro study evaluates the feasibility and efficacy of manual cochlear electrode array insertions via DCA. Free-fitting electrode arrays were inserted in 8 temporal bone specimens with previously drilled DCA tunnels. The insertion depth angle, procedural time, tunnel alignment as well as the inserted scala and intracochlear trauma were assessed. Seven of the 8 insertions were full insertions, with insertion depth angles higher than 520°. Three cases of atraumatic scala tympani insertion, 3 cases of probable basilar membrane rupture and 1 case of dislocation into the scala vestibuli were observed (1 specimen was damaged during extraction). Manual electrode array insertion following a DCA procedure seems to be feasible and safe and is a further step toward clinical application of image-guided otological microsurgery.
Resumo:
The development of susceptibility maps for debris flows is of primary importance due to population pressure in hazardous zones. However, hazard assessment by process-based modelling at a regional scale is difficult due to the complex nature of the phenomenon, the variability of local controlling factors, and the uncertainty in modelling parameters. A regional assessment must consider a simplified approach that is not highly parameter dependant and that can provide zonation with minimum data requirements. A distributed empirical model has thus been developed for regional susceptibility assessments using essentially a digital elevation model (DEM). The model is called Flow-R for Flow path assessment of gravitational hazards at a Regional scale (available free of charge under http://www.flow-r.org) and has been successfully applied to different case studies in various countries with variable data quality. It provides a substantial basis for a preliminary susceptibility assessment at a regional scale. The model was also found relevant to assess other natural hazards such as rockfall, snow avalanches and floods. The model allows for automatic source area delineation, given user criteria, and for the assessment of the propagation extent based on various spreading algorithms and simple frictional laws. We developed a new spreading algorithm, an improved version of Holmgren's direction algorithm, that is less sensitive to small variations of the DEM and that is avoiding over-channelization, and so produces more realistic extents. The choices of the datasets and the algorithms are open to the user, which makes it compliant for various applications and dataset availability. Amongst the possible datasets, the DEM is the only one that is really needed for both the source area delineation and the propagation assessment; its quality is of major importance for the results accuracy. We consider a 10 m DEM resolution as a good compromise between processing time and quality of results. However, valuable results have still been obtained on the basis of lower quality DEMs with 25 m resolution.
Resumo:
HYPOTHESIS A previously developed image-guided robot system can safely drill a tunnel from the lateral mastoid surface, through the facial recess, to the middle ear, as a viable alternative to conventional mastoidectomy for cochlear electrode insertion. BACKGROUND Direct cochlear access (DCA) provides a minimally invasive tunnel from the lateral surface of the mastoid through the facial recess to the middle ear for cochlear electrode insertion. A safe and effective tunnel drilled through the narrow facial recess requires a highly accurate image-guided surgical system. Previous attempts have relied on patient-specific templates and robotic systems to guide drilling tools. In this study, we report on improvements made to an image-guided surgical robot system developed specifically for this purpose and the resulting accuracy achieved in vitro. MATERIALS AND METHODS The proposed image-guided robotic DCA procedure was carried out bilaterally on 4 whole head cadaver specimens. Specimens were implanted with titanium fiducial markers and imaged with cone-beam CT. A preoperative plan was created using a custom software package wherein relevant anatomical structures of the facial recess were segmented, and a drill trajectory targeting the round window was defined. Patient-to-image registration was performed with the custom robot system to reference the preoperative plan, and the DCA tunnel was drilled in 3 stages with progressively longer drill bits. The position of the drilled tunnel was defined as a line fitted to a point cloud of the segmented tunnel using principle component analysis (PCA function in MatLab). The accuracy of the DCA was then assessed by coregistering preoperative and postoperative image data and measuring the deviation of the drilled tunnel from the plan. The final step of electrode insertion was also performed through the DCA tunnel after manual removal of the promontory through the external auditory canal. RESULTS Drilling error was defined as the lateral deviation of the tool in the plane perpendicular to the drill axis (excluding depth error). Errors of 0.08 ± 0.05 mm and 0.15 ± 0.08 mm were measured on the lateral mastoid surface and at the target on the round window, respectively (n =8). Full electrode insertion was possible for 7 cases. In 1 case, the electrode was partially inserted with 1 contact pair external to the cochlea. CONCLUSION The purpose-built robot system was able to perform a safe and reliable DCA for cochlear implantation. The workflow implemented in this study mimics the envisioned clinical procedure showing the feasibility of future clinical implementation.
Resumo:
The application of image-guided systems with or without support by surgical robots relies on the accuracy of the navigation process, including patient-to-image registration. The surgeon must carry out the procedure based on the information provided by the navigation system, usually without being able to verify its correctness beyond visual inspection. Misleading surrogate parameters such as the fiducial registration error are often used to describe the success of the registration process, while a lack of methods describing the effects of navigation errors, such as those caused by tracking or calibration, may prevent the application of image guidance in certain accuracy-critical interventions. During minimally invasive mastoidectomy for cochlear implantation, a direct tunnel is drilled from the outside of the mastoid to a target on the cochlea based on registration using landmarks solely on the surface of the skull. Using this methodology, it is impossible to detect if the drill is advancing in the correct direction and that injury of the facial nerve will be avoided. To overcome this problem, a tool localization method based on drilling process information is proposed. The algorithm estimates the pose of a robot-guided surgical tool during a drilling task based on the correlation of the observed axial drilling force and the heterogeneous bone density in the mastoid extracted from 3-D image data. We present here one possible implementation of this method tested on ten tunnels drilled into three human cadaver specimens where an average tool localization accuracy of 0.29 mm was observed.
Resumo:
HYPOTHESIS Facial nerve monitoring can be used synchronous with a high-precision robotic tool as a functional warning to prevent of a collision of the drill bit with the facial nerve during direct cochlear access (DCA). BACKGROUND Minimally invasive direct cochlear access (DCA) aims to eliminate the need for a mastoidectomy by drilling a small tunnel through the facial recess to the cochlea with the aid of stereotactic tool guidance. Because the procedure is performed in a blind manner, structures such as the facial nerve are at risk. Neuromonitoring is a commonly used tool to help surgeons identify the facial nerve (FN) during routine surgical procedures in the mastoid. Recently, neuromonitoring technology was integrated into a commercially available drill system enabling real-time monitoring of the FN. The objective of this study was to determine if this drilling system could be used to warn of an impending collision with the FN during robot-assisted DCA. MATERIALS AND METHODS The sheep was chosen as a suitable model for this study because of its similarity to the human ear anatomy. The same surgical workflow applicable to human patients was performed in the animal model. Bone screws, serving as reference fiducials, were placed in the skull near the ear canal. The sheep head was imaged using a computed tomographic scanner and segmentation of FN, mastoid, and other relevant structures as well as planning of drilling trajectories was carried out using a dedicated software tool. During the actual procedure, a surgical drill system was connected to a nerve monitor and guided by a custom built robot system. As the planned trajectories were drilled, stimulation and EMG response signals were recorded. A postoperative analysis was achieved after each surgery to determine the actual drilled positions. RESULTS Using the calibrated pose synchronized with the EMG signals, the precise relationship between distance to FN and EMG with 3 different stimulation intensities could be determined for 11 different tunnels drilled in 3 different subjects. CONCLUSION From the results, it was determined that the current implementation of the neuromonitoring system lacks sensitivity and repeatability necessary to be used as a warning device in robotic DCA. We hypothesize that this is primarily because of the stimulation pattern achieved using a noninsulated drill as a stimulating probe. Further work is necessary to determine whether specific changes to the design can improve the sensitivity and specificity.
Resumo:
OBJECTIVE To examine the degree to which use of β blockers, statins, and diuretics in patients with impaired glucose tolerance and other cardiovascular risk factors is associated with new onset diabetes. DESIGN Reanalysis of data from the Nateglinide and Valsartan in Impaired Glucose Tolerance Outcomes Research (NAVIGATOR) trial. SETTING NAVIGATOR trial. PARTICIPANTS Patients who at baseline (enrolment) were treatment naïve to β blockers (n=5640), diuretics (n=6346), statins (n=6146), and calcium channel blockers (n=6294). Use of calcium channel blocker was used as a metabolically neutral control. MAIN OUTCOME MEASURES Development of new onset diabetes diagnosed by standard plasma glucose level in all participants and confirmed with glucose tolerance testing within 12 weeks after the increased glucose value was recorded. The relation between each treatment and new onset diabetes was evaluated using marginal structural models for causal inference, to account for time dependent confounding in treatment assignment. RESULTS During the median five years of follow-up, β blockers were started in 915 (16.2%) patients, diuretics in 1316 (20.7%), statins in 1353 (22.0%), and calcium channel blockers in 1171 (18.6%). After adjusting for baseline characteristics and time varying confounders, diuretics and statins were both associated with an increased risk of new onset diabetes (hazard ratio 1.23, 95% confidence interval 1.06 to 1.44, and 1.32, 1.14 to 1.48, respectively), whereas β blockers and calcium channel blockers were not associated with new onset diabetes (1.10, 0.92 to 1.31, and 0.95, 0.79 to 1.13, respectively). CONCLUSIONS Among people with impaired glucose tolerance and other cardiovascular risk factors and with serial glucose measurements, diuretics and statins were associated with an increased risk of new onset diabetes, whereas the effect of β blockers was non-significant.
Resumo:
Beginning with a brief historical background, the chapter then offers the reader a practical overview of established procedures using image-guided surgery (IGS) in otorhinolaryngology. American and European recommendations for the use of IGS already exist and will be critically discussed in the light that a skilled hand and detailed knowledge of the anatomy by an experienced surgeon cannot yet be replaced by technology alone. Finally, a selected sample of new trends of experimental applications of intraoperative imaging and image-guided therapy will be given.
Resumo:
Traditionally, critical swimming speed has been defined as the speed when a fish can no longer propel itself forward, and is exhausted. To gain a better understanding of the metabolic processes at work during a U(crit) swim test, and that lead to fatigue, we developed a method using in vivo (31)P-NMR spectroscopy in combination with a Brett-type swim tunnel. Our data showed that a metabolic transition point is reached when the fish change from using steady state aerobic metabolism to non-steady state anaerobic metabolism, as indicated by a significant increase in inorganic phosphate levels from 0.3+/-0.3 to 9.5+/-3.4 mol g(-1), and a drop in intracellular pH from 7.48+/-0.03 to 6.81+/-0.05 in muscle. This coincides with the point when the fish change gait from subcarangiform swimming to kick-and-glide bursts. As the number of kicks increased, so too did the Pi concentration, and the pH(i) dropped. Both changes were maximal at U(crit). A significant drop in Gibbs free energy change of ATP hydrolysis from -55.6+/-1.4 to -49.8+/-0.7 kJ mol(-1) is argued to have been involved in fatigue. This confirms earlier findings that the traditional definition of U(crit), unlike other critical points that are typically marked by a transition from aerobic to anaerobic metabolism, is the point of complete exhaustion of both aerobic and anaerobic resources.
Resumo:
Endometriosis is an extremely prevalent disorder characterized by the growth of endometrial tissue at ectopic locations. Glycolysis is an energy-producing mechanism that occurs in almost all cells and requires an adequate uptake of glucose mediated by glucose transporter (GLUT) proteins. At present, however, very little is known about their expression in either the endometrium or the endometriotic lesions. The objective of this study was to examine the expression of SLC2A genes in the endometrium of women with and without endometriosis and in the matching ectopic tissue, and to confirm the presence of the GLUT proteins in ectopic lesions. There was a significantly higher expression of SLC2A3 and a significantly lower expression of SLC2A4 in women with endometriosis compared with those without. In women with endometriosis, the ectopic expression of SLC2A3, SLC2A4 and SLC2A5 was significantly higher than that observed in the matching eutopic tissue. GLUT1 protein expression was present in both epithelial and stromal cells and GLUT3 was confined to CD45-positive leukocytes. GLUT4 expression was strong in both ectopic epithelial and stromal cells and localized to the cellular membrane in epithelial cells. These results show that GLUT expression is altered between eutopic and ectopic tissue and between women with and without endometriosis, and that GLUT4 may represent a significant entry route for glucose into the endometriotic epithelial cells. The inducible nature of GLUT4 and its limited cellular expression may make GLUT4 an attractive target for non-hormone-based treatments of endometriosis.
Resumo:
Endometriosis is an estrogen-dependent disease that can lead to chronic pain and subfertility. Endometriotic lesions found in different locations are heterogeneous and may represent a collection of related but distinct conditions. Whether there is a relationship between hormonal contraceptive (HC) use and endometriosis is still controversial. The purpose of this study was to determine whether HC use affected the prevalence of endometriotic lesions differently based on lesion location. Data was retrospectively collected from 161 patients presenting to the Berne University Women's Hospital between 2008 and 2012 for laparoscopic investigation. Women with histologically proven endometriosis were included in the study and patients were grouped according to lesion location and HC use. The results of the study indicate that HC users are significantly less likely to have endometriotic lesions on the ovaries, although in contrast, no difference was observed in the incidence of lesions in the rectovaginal septum (RVS) or peritoneal region. In addition, women using HC who were diagnosed with endometriotic lesions on the peritoneum were significantly younger than women with lesions in other locations. In conclusion, women with endometriosis who are currently using HC are less likely to have ovarian endometriotic lesions than in alternate locations.
Resumo:
Endometriosis is characterised by the growth of ectopic lesions at multiple locations outside the uterine cavity and may be considered a collection of distinct but related conditions. The exact aetiology of endometriosis is still not clear although a role for inflammation is increasingly accepted. We therefore investigated the inflammatory activity of eutopic tissue and that of the matching ectopic lesions from different locations by measuring the genetic expression of inflammatory chemokines and cytokines. The gene expression in matching eutopic and ectopic tissue was compared, as was the gene expression in lesions from different locations. A significantly higher mRNA expression of the chemokines ENA-78 and RANTES and the cytokines IL-6 and TNF α was observed in endometriotic lesions of the rectovaginal septum (RVS) compared to that of matching eutopic tissue. Comparisons across lesion locations showed a significantly higher expression of IL-6 and TNF α in the RVS compared to lesions from either the ovaries or the peritoneum. These results show that the production of some inflammatory chemokines and cytokines is significantly increased in the ectopic endometrial tissue compared to matching eutopic tissue. Furthermore, IL-6 and TNF α are produced in significantly higher quantities in RVS lesions compared to other lesions.
Resumo:
OBJECTIVE To investigate the effect of gonadotropin-releasing hormone analogues (GnRHa) on the peritoneal fluid microenvironment in women with endometriosis. STUDY DESIGN Peritoneal fluid was collected from 85 women with severe endometriosis (rAFS stage III and IV) during laparoscopic surgery during the proliferative phase. Prior to surgery clinical data were collected. The concentrations of specific markers for endometriosis in the peritoneal fluid were determined using an ELISA and a comparison between peritoneal fluid markers in women using GnRHa and no hormonal treatment was performed using a non-parametric Mann-Whitney U test. RESULTS The study included peritoneal fluid from 39 patients who had been administered GnRHa (Zoladex(®)) in the three months prior to surgery and 46 from women with no hormonal treatment in this period. Concentrations of IL-8, PAPP-A, glycodelin-A and midkine were significantly reduced in the GnRHa treatment group compared to women receiving no hormonal treatment. RANTES, MCP-1, ENA-78, TNF-α, OPG, IP-10 and defensin showed no significant change between the two groups. CONCLUSIONS GnRHa mediate a significant regression in the inflammatory nature of the peritoneal microenvironment in women with endometriosis.