79 resultados para Basophil Degranulation Test -- methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: A false-positive sweat test in patients with deficiency of glucose-6-phosphate-1-dehydrogenase (EC 1.1.1.49; G6PD) is repeatedly reported. METHODS: Sweat chloride or conductivity was measured in 11 patients with G6PD deficiency. RESULTS: Mean (SD) chloride level (n = 8, median age 9.2 years, range 1.9-48.5) was 18.8 (9.6 mmol/l) and, mean (SD) sodium level was 26.0 (10.0 mmol/l), respectively, and mean (SD) conductivity (n = 3, median age 6.6 years, range 1.9-40.5) was 34.3 (6.5 mmol/l). CONCLUSION: In sweat of 11 patients with G6PD deficiency we did not find any abnormality. The reason for alleged false-positive sweat test in patients with G6PD deficiency is not known and we were unable to identify any original reference. It appears that tables of putative false-positive sweat tests in several disease states have been directly "copied and pasted" from one paper or textbook to another without verifying the original literature, a phenomenon one can call "chain citation".

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: To determine the value of the distance doubling visual acuity test in the diagnosis of nonorganic visual loss in a comparative observational case series. METHODS: Twenty-one consecutive patients with nonorganic visual acuity loss and 21 subjects with organic visual loss as controls were included. Best corrected visual acuity was tested at the normal distance of 5 meters using Landolt Cs. The patient was then repositioned and best corrected visual acuity was tested with the previous optotypes at double the distance via a mirror. RESULTS: Nonorganic visual acuity loss was identified in 21 of 21 patients. Sensitivity and specificity of distance-doubling visual acuity test in functional visual loss were found to be 100% (CI; 83%-100%) and 100% (CI; 82%-100%), respectively. CONCLUSION: Distance doubling visual acuity test is widely used to detect nonorganic visual loss. Our results show that this test has a high specificity and sensitivity to detect nonorganic visual impairment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The STAndards for Reporting studies of Diagnostic accuracy (STARD) for investigators and editors and the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) for reviewers and readers offer guidelines for the quality and reporting of test accuracy studies. These guidelines address and propose some solutions to two major threats to validity: spectrum bias and test review bias. STUDY DESIGN AND SETTING: Using a clinical example, we demonstrate that these solutions fail and propose an alternative solution that concomitantly addresses both sources of bias. We also derive formulas that prove the generality of our arguments. RESULTS: A logical extension of our ideas is to extend STARD item 23 by adding a requirement for multivariable statistical adjustment using information collected in QUADAS items 1, 2, and 12 and STARD items 3-5, 11, 15, and 18. CONCLUSION: We recommend reporting not only variation of diagnostic accuracy across subgroups (STARD item 23) but also the effects of the multivariable adjustments on test performance. We also suggest that the QUADAS be supplemented by an item addressing the appropriateness of statistical methods, in particular whether multivariable adjustments have been included in the analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The simple bedside method for sampling undiluted distal pulmonary edema fluid through a normal suction catheter (s-Cath) has been experimentally and clinically validated. However, there are no data comparing non-bronchoscopic bronchoalveolar lavage (mini-BAL) and s-Cath for assessing lung inflammation in acute hypoxaemic respiratory failure. We designed a prospective study in two groups of patients, those with acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) and those with acute cardiogenic lung edema (ACLE), designed to investigate the clinical feasibility of these techniques and to evaluate inflammation in both groups using undiluted sampling obtained by s-Cath. To test the interchangeability of the two methods in the same patient for studying the inflammation response, we further compared mini-BAL and s-Cath for agreement of protein concentration and percentage of polymorphonuclear cells (PMNs). METHODS: Mini-BAL and s-Cath sampling was assessed in 30 mechanically ventilated patients, 21 with ALI/ARDS and 9 with ACLE. To analyse agreement between the two sampling techniques, we considered only simultaneously collected mini-BAL and s-Cath paired samples. The protein concentration and polymorphonuclear cell (PMN) count comparisons were performed using undiluted sampling. Bland-Altman plots were used for assessing the mean bias and the limits of agreement between the two sampling techniques; comparison between groups was performed by using the non-parametric Mann-Whitney-U test; continuous variables were compared by using the Student t-test, Wilcoxon signed rank test, analysis of variance or Student-Newman-Keuls test; and categorical variables were compared by using chi-square analysis or Fisher exact test. RESULTS: Using protein content and PMN percentage as parameters, we identified substantial variations between the two sampling techniques. When the protein concentration in the lung was high, the s-Cath was a more sensitive method; by contrast, as inflammation increased, both methods provided similar estimates of neutrophil percentages in the lung. The patients with ACLE showed an increased PMN count, suggesting that hydrostatic lung edema can be associated with a concomitant inflammatory process. CONCLUSIONS: There are significant differences between the s-Cath and mini-BAL sampling techniques, indicating that these procedures cannot be used interchangeably for studying the lung inflammatory response in patients with acute hypoxaemic lung injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This methods paper outlines the overall design of a community-based multidisciplinary longitudinal study with the intent to stimulate interest and communication from scientists and practitioners studying the role of physical activity in preventive medicine. In adults, lack of regular exercise is a major risk factor in the development of chronic degenerative diseases and is a major contributor to obesity, and now we have evidence that many of our children are not sufficiently active to prevent early symptoms of chronic disease. The lifestyle of our kids (LOOK) study investigates how early physical activity contributes to health and development, utilizing a longitudinal design and a cohort of eight hundred and thirty 7-8-year-old (grade 2) school children followed to age 11-12 years (grade 6), their average family income being very close to that of Australia. We will test two hypotheses, that (a) the quantity and quality of physical activity undertaken by primary school children will influence their psychological and physical health and development; (b) compared with existing practices in primary schools, a physical education program administered by visiting specialists will enhance health and development, and lead to a more positive perception of physical activity. To test the first hypothesis we will monitor all children longitudinally over the 4 years. To test the second we will involve an intervention group of 430 children who receive two 50min physical education classes every week from visiting specialists and a control group of 400 who continue with their usual primary school physical education with their class-room teachers. At the end of grades 2, 4, and 6 we will measure several areas of health and development including blood risk factors for chronic disease, cardiovascular structure and function, physical fitness, psychological characteristics and perceptions of physical activity, bone structure and strength, motor control, body composition, nutritional intake, influence of teachers and family, and academic performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Resonance frequency analysis (RFA) offers the opportunity to monitor the osseointegration of an implant in a simple, noninvasive way. A better comprehension of the relationship between RFA and parameters related to bone quality would therefore help clinicians improve diagnoses. In this study, a bone analog made from polyurethane foam was used to isolate the influences of bone density and cortical thickness in RFA. MATERIALS AND METHODS: Straumann standard implants were inserted in polyurethane foam blocks, and primary implant stability was measured with RFA. The blocks were composed of two superimposed layers with different densities. The top layer was dense to mimic cortical bone, whereas the bottom layer had a lower density to represent trabecular bone. Different densities for both layers and different thicknesses for the simulated cortical layer were tested, resulting in eight different block combinations. RFA was compared with two other mechanical evaluations of primary stability: removal torque and axial loading response. RESULTS: The primary stability measured with RFA did not correlate with the two other methods, but there was a significant correlation between removal torque and the axial loading response (P < .005). Statistical analysis revealed that each method was sensitive to different aspects of bone quality. RFA was the only method able to detect changes in both bone density and cortical thickness. However, changes in trabecular bone density were easier to distinguish with removal torque and axial loading than with RFA. CONCLUSIONS: This study shows that RFA, removal torque, and axial loading are sensitive to different aspects of the bone-implant interface. This explains the absence of correlation among the methods and proves that no standard procedure exists for the evaluation of primary stability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To investigate the contribution of a real-time PCR assay for the detection of Treponema pallidum in various biological specimens with the secondary objective of comparing its value according to HIV status. METHODS: Prospective cohort of incident syphilis cases from three Swiss hospitals (Geneva and Bern University Hospitals, Outpatient Clinic for Dermatology of Triemli, Zurich) diagnosed between January 2006 and September 2008. A case-control study was nested into the cohort. Biological specimens (blood, lesion swab or urine) were taken at diagnosis (as clinical information) and analysed by real-time PCR using the T pallidum 47 kDa gene. RESULTS: 126 specimens were collected from 74 patients with primary (n = 26), secondary (n = 40) and latent (n = 8) syphilis. Among primary syphilis, sensitivity was 80% in lesion swabs, 28% in whole blood, 55% in serum and 29% in urine, whereas among secondary syphilis, it was 20%, 36%, 47% and 44%, respectively. Among secondary syphilis, plasma and cerebrospinal fluid were also tested and provided a sensitivity of 100% and 50%, respectively. The global sensitivity of T pallidum by PCR (irrespective of the compartment tested) was 65% during primary, 53% during secondary and null during latent syphilis. No difference regarding serology or PCR results was observed among HIV-infected patients. Specificity was 100%. CONCLUSIONS: Syphilis PCR provides better sensitivity in lesion swabs from primary syphilis and displays only moderate sensitivity in blood from primary and secondary syphilis. HIV status did not modify the internal validity of PCR for the diagnosis of primary or secondary syphilis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Enzootic pneumonia (EP) of pigs, caused by Mycoplasma hyopneumoniae has been a notifiable disease in Switzerland since May 2003. The diagnosis of EP has been based on multiple methods, including clinical, bacteriological and epidemiological findings as well as pathological examination of lungs (mosaic diagnosis). With the recent development of a real-time PCR (rtPCR) assay with 2 target sequences a new detection method for M. hyopneumoniae became available. This assay was tested for its applicability to nasal swab material from live animals. Pigs from 74 herds (average 10 pigs per herd) were tested. Using the mosaic diagnosis, 22 herds were classified as EP positive and 52 as EP negative. From the 730 collected swab samples we were able to demonstrate that the rtPCR test was 100% specific. In cases of cough the sensitivity on herd level of the rtPCR is 100%. On single animal level and in herds without cough the sensitivity was lower. In such cases, only a positive result would be proof for an infection with M. hyopneumoniae. Our study shows that the rtPCR on nasal swabs from live pigs allows a fast and accurate diagnosis in cases of suspected EP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A total of 272 staphylococcal isolates from cases of bovine mastitis (159 Staphylococcus aureus) belonging to 12 different species were identified with ID32 STAPH galleries, and 51 of them were confirmed by 16S rRNA gene (rrs) sequencing. The same isolates were examined for their hemolytic activity on sheep blood agar, DNase activity, and coagulase activity and with two rapid identification kits (Slidex Staph Plus kit and RAPIDEC Staph from Bio-Merieux). The results of this study confirm those obtained by other groups with hemolysis, DNase, and coagulase. Only 50% of S. aureus isolates from mastitis cases show coagulase activity after 4 h of incubation, and a 24-h incubation is necessary for the full sensitivity of this test. In contrast to results from other studies with human isolates, the Slidex Staph Plus kit was not sensitive enough for the identification of S. aureus from bovine mastitis samples. The aurease test of the RAPIDEC Staph kit showed 100% sensitivity and 100% specificity. Used in conjunction with hemolysis patterns, the RAPIDEC Staph kit is therefore very well adapted to rapid, efficient, and cost-effective identification of S. aureus in cultures from bovine mastitis samples. Sequencing of rrs genes also proved very efficient in identifying the Staphylococcus species encountered in these samples and confirming phenotypical identification results with unsatisfactory scores. With continuously improving technologies and decreasing costs, genetic identification methods like rrs gene sequencing will soon find a place in routine veterinary diagnostics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Little is known about the vasomotor function of human coronary collateral vessels. The purpose of this study was to examine collateral flow under a strong sympathetic stimulus (cold pressor test, CPT). METHODS In 30 patients (62 +/- 12 years) with coronary artery disease, two subsequent coronary artery occlusions were performed with random CPT during one of them. Two minutes before and during the 1 minute-occlusion, the patient's hand was immerged in ice water. For the calculation of a perfusion pressure-independent collateral flow index (CFI), the aortic (Pao), the central venous (CVP) and the coronary wedge pressure (Poccl) were measured: CFI = (Poccl - CVP)/(Pao - CVP). RESULTS CPT lead to an increase in Pao from 98 +/- 14 to 105 +/- 15 mm Hg (p = 0.002). Without and with CPT, CFI increased during occlusion from 14% +/- 10% to 16% +/- 10% (p = 0.03) and from 17% +/- 9% to 19% +/- 9% (p = 0.006), respectively, relative to normal flow. During CPT, CFI was significantly higher at the beginning as well as at the end of the occlusion compared to identical instants without CPT. CFI at the end of the control occlusion did not differ significantly from the CFI at the beginning of occlusion with CPT. CONCLUSIONS During balloon occlusion, collateral flow increased due to collateral recruitment independent of external sympathetic stimulation. Sympathetic stimulation using CPT additionally augmented collateral flow. The collateral-flow-increasing effect of CPT is comparable to the recruitment effect of the occlusion itself. This may reflect a coronary collateral vasodilation mediated by the sympathetic nervous system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND In adults it is well documented that there are substantial losses to the programme between HIV testing and start of antiretroviral therapy (ART). The magnitude and reasons for loss to follow-up and death between HIV diagnosis and start of ART in children are not well defined. METHODS We searched the PubMed and EMBASE databases for studies on children followed between HIV diagnosis and start of ART in low-income settings. We examined the proportion of children with a CD4 cell count/percentage after after being diagnosed with HIV infection, the number of treatment-eligible children starting ART and predictors of loss to programme. Data were extracted in duplicate. RESULTS Eight studies from sub-Saharan Africa and two studies from Asia with a total of 10,741 children were included. Median age ranged from 2.2 to 6.5 years. Between 78.0 and 97.0% of HIV-infected children subsequently had a CD4 cell count/percentage measured, 63.2 to 90.7% of children with an eligibility assessment met the eligibility criteria for the particular setting and time and 39.5 to 99.4% of the eligible children started ART. Three studies reported an association between low CD4 count/percentage and ART initiation while no association was reported for gender. Only two studies reported on pre-ART mortality and found rates of 13 and 6 per 100 person-years. CONCLUSION Most children who presented for HIV care met eligibility criteria for ART. There is an urgent need for strategies to improve the access to and retention to care of HIV-infected children in resource-limited settings.