29 resultados para spray arc


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement association and initial orbit determination is a fundamental task when building up a database of space objects. This paper proposes an efficient and robust method to determine the orbit using the available information of two tracklets, i.e. their line-of-sights and their derivatives. The approach works with a boundary-value formulation to represent hypothesized orbital states and uses an optimization scheme to find the best fitting orbits. The method is assessed and compared to an initial-value formulation using a measurement set taken by the Zimmerwald Small Aperture Robotic Telescope of the Astronomical Institute at the University of Bern. False associations of closely spaced objects on similar orbits cannot be completely eliminated due to the short duration of the measurement arcs. However, the presented approach uses the available information optimally and the overall association performance and robustness is very promising. The boundary-value optimization takes only around 2% of computational time when compared to optimization approaches using an initial-value formulation. The full potential of the method in terms of run-time is additionally illustrated by comparing it to other published association methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given a short-arc optical observation with estimated angle-rates, the admissible region is a compact region in the range / range-rate space defined such that all likely and relevant orbits are contained within it. An alternative boundary value problem formulation has recently been proposed where range / range hypotheses are generated with two angle measurements from two tracks as input. In this paper, angle-rate information is reintroduced as a means to eliminate hypotheses by bounding their constants of motion before a more computationally costly Lambert solver or differential correction algorithm is run.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Homogeneously reprocessed combined GPS/GLONASS 1- and 3-day solutions from 1994 to 2013, generated by the Center for Orbit Determination in Europe (CODE) in the frame of the second reprocessing campaign REPRO-2 of the International GNSS Service, as well as GPS- and GLONASS-only 1- and 3-day solutions for the years 2009 to 2011 are analyzed to assess the impact of the arc length on the estimated Earth Orientation Parameters (EOP, namely polar motion and length of day), on the geocenter, and on the orbits. The conventional CODE 3-day solutions assume continuity of orbits, polar motion components, and of other parameters at the day boundaries. An experimental 3-day solution, which assumes continuity of the orbits, but independence from day to day for all other parameters, as well as a non-overlapping 3-day solution, is included into our analysis. The time series of EOPs, geocenter coordinates, and orbit misclosures, are analyzed. The long-arc solutions were found to be superior to the 1-day solutions: the RMS values of EOP and geocenter series are typically reduced between 10 and 40 %, except for the polar motion rates, where RMS reductions by factors of 2–3 with respect to the 1-day solutions are achieved for the overlapping and the non-overlapping 3-day solutions. In the low-frequency part of the spectrum, the reduction is even more important. The better performance of the orbits of 3-day solutions with respect to 1-day solutions is also confirmed by the validation with satellite laser ranging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nasal spray from lemon and quince (LQNS) is used to treat hay fever symptoms and has been shown to inhibit histamine release from mast cells in vitro. Forty-three patients with grass pollen allergy (GPA) were randomized to be treated either with placebo or LQNS for one week, respectively, in a cross-over study. At baseline and after the respective treatments patients were provoked with grass pollen allergen. Outcome parameters were nasal flow measured with rhinomanometry (primary), a nasal symptom score, histamine in the nasal mucus and tolerability. In the per protocol population absolute inspiratory nasal flow 10 and 20 min after provocation was higher with LQNS compared to placebo (-37 ± 87 mL/s; p = 0.027 and -44 ± 85 mL/s; p = 0.022). The nasal symptom score showed a trend (3.3 ± 1.8 in the placebo and 2.8 ± 1.5 in the LQNS group; p = 0.070) in favor of LQNS; the histamine concentration was not significantly different between the groups. Tolerability of both, LQNS and placebo, was rated as very good. LQNS seems to have an anti-allergic effect in patients with GPA. Copyright © 2016 John Wiley & Sons, Ltd.