46 resultados para software quality assurance


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present paper describes standardized procedures within clinical sleep medicine. As such, it is a continuation of the previously published European guidelines for the accreditation of sleep medicine centres and European guidelines for the certification of professionals in sleep medicine, aimed at creating standards of practice in European sleep medicine. It is also part of a broader action plan of the European Sleep Research Society, including the process of accreditation of sleep medicine centres and certification of sleep medicine experts, as well as publishing the Catalogue of Knowledge and Skills for sleep medicine experts (physicians, non-medical health care providers, nurses and technologists), which will be a basis for the development of relevant educational curricula. In the current paper, the standard operational procedures sleep medicine centres regarding the diagnostic and therapeutic management of patients evaluated at sleep medicine centres, accredited according to the European Guidelines, are based primarily on prevailing evidence-based medicine principles. In addition, parts of the standard operational procedures are based on a formalized consensus procedure applied by a group of Sleep Medicine Experts from the European National Sleep Societies. The final recommendations for standard operational procedures are categorized either as 'standard practice', 'procedure that could be useful', 'procedure that is not useful' or 'procedure with insufficient information available'. Standard operational procedures described here include both subjective and objective testing, as well as recommendations for follow-up visits and for ensuring patients' safety in sleep medicine. The overall goal of the actual standard operational procedures is to further develop excellence in the practice and quality assurance of sleep medicine in Europe.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We recently reported on the Multi Wave Animator (MWA), a novel open-source tool with capability of recreating continuous physiologic signals from archived numerical data and presenting them as they appeared on the patient monitor. In this report, we demonstrate for the first time the power of this technology in a real clinical case, an intraoperative cardiopulmonary arrest following reperfusion of a liver transplant graft. Using the MWA, we animated hemodynamic and ventilator data acquired before, during, and after cardiac arrest and resuscitation. This report is accompanied by an online video that shows the most critical phases of the cardiac arrest and resuscitation and provides a basis for analysis and discussion. This video is extracted from a 33-min, uninterrupted video of cardiac arrest and resuscitation, which is available online. The unique strength of MWA, its capability to accurately present discrete and continuous data in a format familiar to clinicians, allowed us this rare glimpse into events leading to an intraoperative cardiac arrest. Because of the ability to recreate and replay clinical events, this tool should be of great interest to medical educators, researchers, and clinicians involved in quality assurance and patient safety.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Spine Tango is currently the only international spine registry in existence. It was developed under the auspices of Eurospine, the Spine Society of Europe, and is hosted at the University of Bern, Switzerland. The HJD Spine Center successfully tested Spine Tango during a 3-month pilot study and has since expanded documentation activities to more surgeons. Workflow integration and dedicated research staff are key factors for such an endeavor. Participation enables benchmarking against national and international peers and outcome research and quality assurance of surgical and non-surgical treatments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The architecture of European Plastic Surgery was published in 1996 [Nicolai JPA, Scuderi N. Plastic surgical Europe in an organogram. Eur J Plast Surg 1996; 19: 253-256.] It is the objective of this paper to update information of that article. Continuing medical education (CME), science, training, examination, quality assurance and relations with the European Commission and Parliament all are aspects covered by the organisations to be discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bacteria with antimicrobial resistance can be transferred from animals to humans and may compromise antimicrobial treatment in case of infection. To determine the antimicrobial resistance situation in bacteria from Swiss veal calves, faecal samples from 500 randomly selected calves originating from 129 farms were collected at four big slaughterhouses. Samples were cultured for Escherichia coli, Enterococcus sp. and Campylobacter sp. and isolated strains were tested for antimicrobial susceptibility to selected antimicrobial agents by the minimal inhibitory concentration technique using the broth microdilution method. From 100 farms, data on farm management, animal husbandry and antimicrobial treatments of the calves were collected by questionnaire. Risk factors associated with antimicrobial resistance were identified by logistic regression. In total, 467 E. coli, 413 Enterococcus sp. and 202 Campylobacter sp. were isolated. Of those, 68.7%, 98.7% and 67.8%, respectively, were resistant to at least one of the tested antimicrobial agents. Resistance was mainly observed to antimicrobials frequently used in farm animals. Prevalence of resistance to antimicrobials important for human treatment was generally low. However, a rather high number of quinupristin/dalfopristin-resistant Enterococcus faecium and ciprofloxacin-resistant Campylobacter sp. were detected. External calf purchase, large finishing groups, feeding of milk by-products and administration of antimicrobials through feed upon arrival of the animals on the farm significantly increased the risk of antimicrobial resistance at farm level. Participation in a quality assurance programme and injection of a macrolide upon arrival of the animals on the farm had a protective effect. The present study showed that veal calves may serve as a reservoir for resistant bacteria. To ensure food safety, veal calves should be included in the national monitoring programme for antimicrobial resistance in farm animals. By improving farm management and calf husbandry the prevalence of resistance may be reduced.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In climate research the interest on carbonaceous particles has increased over the last years because of their influence on the radiation balance of the earth. Nevertheless, there is a paucity of available data regarding their concentrations and sources in the past. Such data would be important for a better understanding of their effects and for estimating their influence on future climate. Here, a technique is described to extract carbonaceous particles from ice core samples with subsequent separation of the two main constituents into organic carbon (OC) and elemental carbon (EC) for analysis of their concentrations in the past. This is combined with further analysis of OC and EC 14C/12C ratios by accelerator mass spectrometry (AMS), what can be used for source apportionment studies of past emissions. We further present how 14C analysis of the OC fraction could be used in the future to date any ice core extracted from a high-elevation glacier. Described sample preparation steps to final analysis include the combustion of micrograms of water–insoluble carbonaceous particles, primary collected by filtration of melted ice samples, the graphitisation of the obtained CO2 to solid AMS target material and final AMS measurements. Possible fractionation processes were investigated for quality assurance. Procedural blanks were reproducible and resulted in carbon masses of 1.3 ± 0.6 μg OC and 0.3 ± 0.1 μg EC per filter. The determined fraction of modern carbon (fM) for the OC blank was 0.61 ± 0.13. The analysis of processed IAEA-C6 and IAEA-C7 reference material resulted in fM = 1.521 ± 0.011 and δ13C = −10.85 ± 0.19‰, and fM = 0.505 ± 0.011 and δ13C = −14.21 ± 0.19‰, respectively, in agreement with consensus values. Initial carbon contents were thereby recovered with an average yield of 93%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The radiation burden of an individual patient caused by a radiological examination depends strongly on the technical parameters, such as kV and mAs. As an inquiry among 150 swiss physicians showed, rather different irradiation techniques are used for the same examination. Depending on these irradiation techniques, the doses may vary by almost a factor of ten. These large variations in dose indicate that in some clinics or hospitals the radiographic techniques and the film processing are at fault. This fact has to be accounted for by future efforts of quality assurance in diagnostic radiology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: High intercoder reliability (ICR) is required in qualitative content analysis for assuring quality when more than one coder is involved in data analysis. The literature is short of standardized procedures for ICR procedures in qualitative content analysis. OBJECTIVE: To illustrate how ICR assessment can be used to improve codings in qualitative content analysis. METHODS: Key steps of the procedure are presented, drawing on data from a qualitative study on patients' perspectives on low back pain. RESULTS: First, a coding scheme was developed using a comprehensive inductive and deductive approach. Second, 10 transcripts were coded independently by two researchers, and ICR was calculated. A resulting kappa value of .67 can be regarded as satisfactory to solid. Moreover, varying agreement rates helped to identify problems in the coding scheme. Low agreement rates, for instance, indicated that respective codes were defined too broadly and would need clarification. In a third step, the results of the analysis were used to improve the coding scheme, leading to consistent and high-quality results. DISCUSSION: The quantitative approach of ICR assessment is a viable instrument for quality assurance in qualitative content analysis. Kappa values and close inspection of agreement rates help to estimate and increase quality of codings. This approach facilitates good practice in coding and enhances credibility of analysis, especially when large samples are interviewed, different coders are involved, and quantitative results are presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article reviews the diagnostic steps and risk stratification in acute coronary syndromes. Therapeutic measures according to risk stratification are discussed as well. The article also reviews quality assurance in Switzerland (AMIS Plus Registry). Potential future perspectives in the treatment of acute coronary syndromes are shown.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Screening for malignant disease aims to reduce the population risk of impaired health due to the tumor in question. Screening does not only entail testing but covers all steps required to achieve the intended reduction in risk, from the appropriate information of the population to a suitable therapy. Screening tests are performed in individuals free or unaware of any symptoms associated with the tumor. An essential condition is a recognizable pathological abnormality, which occurs without symptoms and represents a pre-clinical, early stage of the tumor. Overdiagnosis and overtreatment have only recently been recognized as important problems of screening for malignant disease. Overdiagnosis is defined as a screening-detected tumor that would never have led to symptoms. In prostate-specific antigen (PSA) screening for prostate cancer 50 % - 70 % of screening-detected cancers represent such overdiagnoses. Similarly, in the case of mammography screening 20 % - 30 % of screening-detected breast cancers are overdiagnoses. The evaluation of screening interventions is often affected by biases such as healthy screenee effects or length and lead time bias. Randomized controlled trials are therefore needed to examine the efficacy and effectiveness of screening interventions and to define the rate of adverse outcomes such as unnecessary diagnostic evaluations, overdiagnosis and overtreatment. Unfortunately there is no independent Swiss body comparable to the National Screening Committee in the United Kingdom or the United States Preventive Services Task Force, which examines screening tests and programs and develops recommendations. Clearly defined goals, a central organization responsible for inviting eligible individuals, documentation and quality assurance and balanced information of the public are important attributes of successful screening programs. In Switzerland the establishment of such programs is hampered by the highly fragmented, Federal health system which allows patients to access specialists directly.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Contagious Bovine Pleuropneumonia (CBPP) is the most important chronic pulmonary disease of cattle on the African continent causing severe economic losses. The disease, caused by infection with Mycoplasma mycoides subsp. mycoides is transmitted by animal contact and develops slowly into a chronic form preventing an early clinical diagnosis. Because available vaccines confer a low protection rate and short-lived immunity, the rapid diagnosis of infected animals combined with traditional curbing measures is seen as the best way to control the disease. While traditional labour-intensive bacteriological methods for the detection of M. mycoides subsp. mycoides have been replaced by molecular genetic techniques in the last two decades, these latter approaches require well-equipped laboratories and specialized personnel for the diagnosis. This is a handicap in areas where CBPP is endemic and early diagnosis is essential. RESULTS We present a rapid, sensitive and specific diagnostic tool for M. mycoides subsp. mycoides detection based on isothermal loop-mediated amplification (LAMP) that is applicable to field conditions. The primer set developed is highly specific and sensitive enough to diagnose clinical cases without prior cultivation of the organism. The LAMP assay detects M. mycoides subsp. mycoides DNA directly from crude samples of pulmonary/pleural fluids and serum/plasma within an hour using a simple dilution protocol. A photometric detection of LAMP products allows the real-time visualisation of the amplification curve and the application of a melting curve/re-association analysis presents a means of quality assurance based on the predetermined strand-inherent temperature profile supporting the diagnosis. CONCLUSION The CBPP LAMP developed in a robust kit format can be run on a battery-driven mobile device to rapidly detect M. mycoides subsp. mycoides infections from clinical or post mortem samples. The stringent innate quality control allows a conclusive on-site diagnosis of CBPP such as during farm or slaughter house inspections.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The development of a robust assay based on MEKC for cefepime in human serum and plasma with internal quality assurance is reported. Sample preparation comprises protein precipitation in the presence of SDS at pH 4.5. This is a gentle approach for which decomposition of cefepime during sample handling is negligible. After hydrodynamic sample injection of the supernatant, analysis occurs in a phosphate/borate buffer at pH 9.1 with 75 mM SDS using normal polarity and analyte detection at 257 nm. The MEKC run time interval and throughput are about 5 min and seven samples per hour, respectively. The calibration range for cefepime is 1-60 μg/mL, with 1 μg/mL being the LOQ. The performance of the assay with multilevel internal calibration was assessed with calibration and control samples. The assay is shown to be simple, inexpensive, reproducible, and robust. It was applied to determine cefepime levels in the sera of critically ill patients and to assess the instability of cefepime in patient and control samples. Our data revealed that serum containing cefepime can be stored at -20°C for a short time, whereas for long-term storage, samples have to be kept at -70°C.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The aim of this work is to evaluate the geometric accuracy of a prerelease version of a new six degrees of freedom (6DoF) couch. Additionally, a quality assurance method for 6DoF couches is proposed. Methods: The main principle of the performance tests was to request a known shift for the 6DoF couch and to compare this requested shift with the actually applied shift by independently measuring the applied shift using different methods (graph paper, laser, inclinometer, and imaging system). The performance of each of the six axes was tested separately as well as in combination with the other axes. Functional cases as well as realistic clinical cases were analyzed. The tests were performed without a couch load and with a couch load of up to 200 kg and shifts in the range between −4 and +4 cm for the translational axes and between −3° and +3° for the rotational axes were applied. The quality assurance method of the new 6DoF couch was performed using a simple cube phantom and the imaging system. Results: The deviations (mean ± one standard deviation) accumulated over all performance tests between the requested shifts and the measurements of the applied shifts were −0.01 ± 0.02, 0.01 ± 0.02, and 0.01 ± 0.02 cm for the longitudinal, lateral, and vertical axes, respectively. The corresponding values for the three rotational axes couch rotation, pitch, and roll were 0.03° ± 0.06°, −0.04° ± 0.12°, and −0.01° ± 0.08°, respectively. There was no difference found between the tests with and without a couch load of up to 200 kg. Conclusions: The new 6DoF couch is able to apply requested shifts with high accuracy. It has the potential to be used for treatment techniques with the highest demands in patient setup accuracy such as those needed in stereotactic treatments. Shifts can be applied efficiently and automatically. Daily quality assurance of the 6DoF couch can be performed in an easy and efficient way. Long-term stability has to be evaluated in further tests.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within ±1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Radiocarbon analysis of the carbonaceous aerosol allows an apportionment of fossil and non-fossil sources of airborne particulate matter (PM). A chemical separation of total carbon (TC) into its subfractions organic carbon (OC) and elemental carbon (EC) refines this powerful technique, as OC and EC originate from different sources and undergo different processes in the atmosphere. Although C-14 analysis of TC, EC, and OC has recently gained increasing attention, interlaboratory quality assurance measures have largely been missing, especially for the isolation of EC and OC. In this work, we present results from an intercomparison of 9 laboratories for C-14 analysis of carbonaceous aerosol samples on quartz fiber filters. Two ambient PM samples and 1 reference material (RM 8785) were provided with representative filter blanks. All laboratories performed C-14 determinations of TC and a subset of isolated EC and OC for isotopic measurement. In general, C-14 measurements of TC and OC agreed acceptably well between the laboratories, i.e. for TC within 0.015-0.025 (FC)-C-14 for the ambient filters and within 0.041 (FC)-C-14 for RM 8785. Due to inhomogeneous filter loading, RM 8785 demonstrated only limited applicability as a reference material for C-14 analysis of carbonaceous aerosols. C-14 analysis of EC revealed a large deviation between the laboratories of 28-79 as a consequence of different separation techniques. This result indicates a need for further discussion on optimal methods of EC isolation for C-14 analysis and a second stage of this intercomparison.