34 resultados para shot peening
Resumo:
OBJECTIVES: Implementation of an experimental model to compare cartilage MR imaging by means of histological analyses. MATERIAL AND METHODS: MRI was obtained from 4 patients expecting total knee replacement at 1.5 and/or 3T prior surgery. The timeframe between pre-op MRI and knee replacement was within two days. Resected cartilage-bone samples were tagged with Ethi((R))-pins to reproduce the histological cutting course. Pre-operative scanning at 1.5T included following parameters for fast low angle shot (FLASH: TR/TE/FA=33ms/6ms/30 degrees , BW=110kHz, 120mmx120mm FOV, 256x256 matrix, 0.65mm slice-thickness) and double echo steady state (DESS: TR/TE/FA=23.7ms/6.9ms/40 degrees , BW=130kHz, 120x120mm FOV, 256x256 matrix, 0.65mm slice-thickness). At 3T, scan parameters were: FLASH (TR/TE/FA=12.2ms/5.1ms/10 degrees , BW=130kHz, 170x170mm FOV, 320x320, 0.5mm slice-thickness) and DESS (TR/TE/FA=15.6ms/4.5ms/25 degrees , BW=200kHz, 135mmx150mm FOV, 288x320matrix, 0.5mm slice-thickness). Imaging of the specimens was done the same day at 1.5T. MRI (Noyes) and histological (Mankin) score scales were correlated using the paired t-test. Sensitivity and specificity for the detection of different grades of cartilage degeneration were assessed. Inter-reader and intra-reader reliability was determined using Kappa analysis. RESULTS: Low correlation (sensitivity, specificity) was found for both sequences in normal to mild Mankin grades. Only moderate to severe changes were diagnosed with higher significance and specificity. The use of higher field-strengths was advantageous for both protocols with sensitivity values ranging from 13.6% to 93.3% (FLASH) and 20.5% to 96.2% (DESS). Kappa values ranged from 0.488 to 0.944. CONCLUSIONS: Correlating MR images with continuous histological slices was feasible by using three-dimensional imaging, multi-planar-reformat and marker pins. The capability of diagnosing early cartilage changes with high accuracy could not be proven for both FLASH and DESS.
Resumo:
OBJECTIVE: To obtain precise information on the optimal time window for surgical antimicrobial prophylaxis. SUMMARY BACKGROUND DATA: Although perioperative antimicrobial prophylaxis is a well-established strategy for reducing the risk of surgical site infections (SSI), the optimal timing for this procedure has yet to be precisely determined. Under today's recommendations, antibiotics may be administered within the final 2 hours before skin incision, ideally as close to incision time as possible. METHODS: In this prospective observational cohort study at Basel University Hospital we analyzed the incidence of SSI by the timing of antimicrobial prophylaxis in a consecutive series of 3836 surgical procedures. Surgical wounds and resulting infections were assessed to Centers for Disease Control and Prevention standards. Antimicrobial prophylaxis consisted in single-shot administration of 1.5 g of cefuroxime (plus 500 mg of metronidazole in colorectal surgery). RESULTS: The overall SSI rate was 4.7% (180 of 3836). In 49% of all procedures antimicrobial prophylaxis was administered within the final half hour. Multivariable logistic regression analyses showed a significant increase in the odds of SSI when antimicrobial prophylaxis was administered less than 30 minutes (crude odds ratio = 2.01; adjusted odds ratio = 1.95; 95% confidence interval, 1.4-2.8; P < 0.001) and 120 to 60 minutes (crude odds ratio = 1.75; adjusted odds ratio = 1.74; 95% confidence interval, 1.0-2.9; P = 0.035) as compared with the reference interval of 59 to 30 minutes before incision. CONCLUSIONS: When cefuroxime is used as a prophylactic antibiotic, administration 59 to 30 minutes before incision is more effective than administration during the last half hour.
Resumo:
Physical fitness can be evaluated in competitive and school sports with different field tests under different conditions and goals. To produce valid results, a field test must be practical and reach high standards of test criteria (objectivity, reliability, validity). The purpose of this study was to investigate the test criteria and the practicability of a group of field tests called «SUISSE Sport Test Konzept Basis Feldtestbatterie». For 20-m sprint, ventral trunk muscle test, standing long jump, 2-kg medicine ball shot, obstacle course and cooper-test, test quality and practicability were evaluated. 221 children and adolescents from competitive sports and different school levels took part in the study. According to school level, they were divided into 3 groups (P: 7–11.5 y, S1: 11.6–15.5 y, S2: 15.6–21.8 y). Objectivity was tested for time or distance measurement in all tests as well as for error rating in obstacle test. For reliability measurement, 162 subjects performed the field tests twice within a few weeks. For validity results of standing long jump were compared with counter movement jump performance on a force plate. Correlation analysis was performed and level of significance was set for p < 0.05. For accuracy standard error was calculated. All tests achieved sufficient to excellent objectiv - ity with correlation-coefficient (r) lying between 0.85 and 0.99. Reliability was very good (r = 0.84–0.97). In cooper- and trunk test, reliability was higher for athletes than for pupils (trunk test: r = 0.95 vs. r = 0.62, cooper-test: r = 0.90 vs. r = 0.78). In those tests the reliability decreases with increasing age (cooper-test: P: r = 0.84, S1: r = 0.69, S2: r = 0.52; trunk-test: P: r = 0.69, S1: r = 0.71; S2: r = 0.39). Validity for standing long jump was good (r = 0.75–0.86). The standard error of the mean was between 4–8%, with the exception for cooper-test (athletes: 6%, pupils: 11%) and trunk test (athletes: 14%, pupils: 46%). The results show that the evaluated group of field tests is a practicable, objective and reliable tool to determine physical skills in young athletes as well as in a scholar setting over a broad age range. Most of the tests achieved the test criteria with the grades good to excellent. The lower coefficient of reliability for cooper- and trunk test by the pupils could be explained by motivational problems in this setting. For up to 20 subjects, a tester can accomplish the tests within 3 h. Finally, age-dependent grades were elaborated
Resumo:
Two technical solutions using single or dual shot offer different advantages and disadvantages for dual energy subtraction. The principles of these are explained and the main clinical applications with results are demonstrated. Elimination of overlaying bone and proof or exclusion of calcification are the primary aims of energy subtraction chest radiography, offering unique information in different clinical situations.
Resumo:
Sarcoptic mange is a highly contagious skin disease that can have a devastating impact on affected wild mammal populations. There are notable variations in the clinical and pathologic picture of sarcoptic mange among species and among conspecifics. However, the origin of these variations is unclear. We propose a classification scheme for skin lesions associated with Sarcoptes scabiei infestation to provide a basis for a subsequent risk factor analysis. We conducted a case-control study focused on macroscopic and histologic examination of the skin, using 279 red foxes (Vulpes vulpes) found dead or shot in Switzerland between November 2004 and February 2006. All animals were submitted to gross necropsy following a detailed protocol. Selection criteria for cases (n=147) vs. controls (n=111) were the presence or absence of mange-like lesions, mite detection by isolation or histologic examination, and serologic testing for S. scabiei antibodies. Characteristic features of mange lesions were scored macroscopically in all foxes and histologically in 67 cases and 15 controls. We classified skin lesions and associated necropsy findings into three types of mange: A) early stage (n=45): focal-extensive skin lesions, thin crusts, mild to moderate alopecia, few mites, numerous eosinophils, and mild lymph node enlargement; B) hyperkeratotic, fatal form (n=86): generalized skin lesions, thick crusts with or without alopecia, foul odor, abundance of mites, numerous bacteria and yeasts, numerous lymphocytes and mast cells, severe lymph node enlargement, and emaciation; C) alopecic, healing form (n=16): focal lesions, no crusts, severe alopecia, hyperpigmentation and lichenification, absence of mites, mixed cell infiltration, and rare mild lymph node enlargement. We hypothesize that after stage A, the animal either enters stage B and dies, or stage C and survives, depending on largely unknown extrinsic or intrinsic factors affecting the host ability to control mite infestation.
Resumo:
The analysis and reconstruction of forensically relevant events, such as traffic accidents, criminal assaults and homicides are based on external and internal morphological findings of the injured or deceased person. For this approach high-tech methods are gaining increasing importance in forensic investigations. The non-contact optical 3D digitising system GOM ATOS is applied as a suitable tool for whole body surface and wound documentation and analysis in order to identify injury-causing instruments and to reconstruct the course of event. In addition to the surface documentation, cross-sectional imaging methods deliver medical internal findings of the body. These 3D data are fused into a whole body model of the deceased. Additional to the findings of the bodies, the injury inflicting instruments and incident scene is documented in 3D. The 3D data of the incident scene, generated by 3D laser scanning and photogrammetry, is also included into the reconstruction. Two cases illustrate the methods. In the fist case a man was shot in his bedroom and the main question was, if the offender shot the man intentionally or accidentally, as he declared. In the second case a woman was hit by a car, driving backwards into a garage. It was unclear if the driver drove backwards once or twice, which would indicate that he willingly injured and killed the woman. With this work, we demonstrate how 3D documentation, data merging and animation enable to answer reconstructive questions regarding the dynamic development of patterned injuries, and how this leads to a real data based reconstruction of the course of event.
Resumo:
Backspatter from wounds caused by contact shots against a biological target had before been shown to be propelled into firearms' barrels where they can persist and be retrieved from as relevant forensic evidence. Herein, that insight was applied to the investigation of a case of multiple familial homicide with a firearm. Samples of backspatter were collected from the firearm using DNA-free swabs. DNA was extracted from the swabs, and 16 STR systems were PCR-amplified to generate DNA profiles of all victims shot by the firearm. The quality of the resulting DNA profiles was sufficient to exclude the perpetrator as donor and to differentiate the three closely related victims thereby proving that all three victims had been shot by the same firearm from very close or contact distance. A key insight gained from this case was that not only a firearms' barrel inside but other inner surfaces may be charged with profilable DNA.
Resumo:
Mass spectrometric analysis of elemental and isotopic compositions of several NIST standards is performed by a miniature laser ablation/ionisation reflectron-type time-of-flight mass spectrometer (LMS) using a fs-laser ablation ion source (775 nm, 190 fs, 1 kHz). The results of the mass spectrometric studies indicate that in a defined range of laser irradiance (fluence) and for a certain number of accumulations of single laser shot spectra, the measurements of isotope abundances can be conducted with a measurement accuracy at the per mill level and at the per cent level for isotope concentrations higher and lower than 100 ppm, respectively. Also the elemental analysis can be performed with a good accuracy. The LMS instrument combined with a fs-laser ablation ion source exhibits similar detection efficiency for both metallic and non-metallic elements. Relative sensitivity coefficients were determined and found to be close to one, which is of considerable importance for the development of standard-less instruments. Negligible thermal effects, sample damage and excellent characteristics of the fs-laser beam are thought to be the main reason for substantial improvement of the instrumental performance compared to other laser ablation mass spectrometers.
Resumo:
Introduction Current empirical findings indicate that the efficiency of decision making (both for experts and near-experts) in simple situations is reduced under increased stress (Wilson, 2008). Explaining the phenomenon, the Attentional Control Theory (ACT, Eysenck et al., 2007) postulates an impairment of attentional processes resulting in a less efficient processing of visual information. From a practitioner’s perspective, it would be highly relevant to know whether this phenomenon can also be found in complex sport situations like in the game of football. Consequently, in the present study, decision making of football players was examined under regular vs. increased anxiety conditions. Methods 22 participants (11 experts and 11 near-experts) viewed 24 complex football situations (counterbalanced) in two anxiety conditions from the perspective of the last defender. They had to decide as fast and accurate as possible on the next action of the player in possession (options: shot on goal, dribble or pass to a designated team member) for equal numbers of trials in a near and far distance condition (based on the position of the player in possession). Anxiety was manipulated via a competitive environment, false feedback as well as ego threats. Decision time and accuracy, gaze behaviour (e.g., fixation duration on different locations) as well as state anxiety and mental effort were used as dependent variables and analysed with 2 (expertise) x 2 (distance) x 2 (anxiety) ANOVAs with repeated measures on the last two factors. Besides expertise differences, it was hypothesised that, based on ACT, increased anxiety reduces performance efficiency and impairs gaze behaviour. Results and Discussion Anxiety was manipulated successfully, indicated by higher ratings of state anxiety, F(1, 20) = 13.13, p < .01, ηp2 = .40. Besides expertise differences in decision making – experts responded faster, F(1, 20) = 11.32, p < .01, ηp2 = .36, and more accurate, F(1,20) = 23.93, p < .01, ηp2 = .55, than near-experts – decision time, F(1, 20) = 9.29, p < .01, ηp2 = .32, and mental effort, F(1, 20) = 7.33, p = .01, ηp2 = .27, increased for both groups in the high anxiety condition. This result confirms the ACT assumption that processing efficiency is reduced when being anxious. Replicating earlier findings, a significant expertise by distance interaction could be observed, F(1, 18) = 18.53, p < .01, ηp2 = .51), with experts fixating longer on the player in possession or the ball in the near distance and longer on other opponents, teammates and free space in the far distance condition. This shows that experts are able to adjust their gaze behaviour to affordances of displayed playing patterns. Additionally, a three way interaction was found, F(1, 18) = 7.37 p = .01, ηp2 = .29, revealing that experts utilised a reduced number of fixations in the far distance condition when being anxious indicating a reduced ability to pick up visual information. Since especially the visual search behaviour of experts was impaired, the ACT prediction that particularly top-down processes are affected by anxiety could be confirmed. Taken together, the results show that sports performance is negatively influenced by anxiety since longer response times, higher mental effort and inefficient visual search behaviour were observed. From a practitioner’s perspective, this finding might suggest preferring (implicit) perceptual cognitive training; however, this recommendation needs to be empirically supported in intervention studies. References: Eysenck, M. W., Derakshan, N., Santos, R., & Calvo, M. G. (2007). Anxiety and cognitive performance: Attentional control theory. Emotion, 7, 336-353. Wilson, M. (2008). From processing efficiency to attentional control: A mechanistic account of the anxiety-performance relationship. Int. Review of Sport and Exercise Psychology, 1, 184-201.
Resumo:
The Quiet Eye (QE; Vickers 1996) has been shown to underpin successful performance, differentiating both expertise (inter-individual) and proficiency (intra-individual), with experts and successful attempts characterised by longer QE durations. The QE is proposed to reflect the time needed to organise and fine tune the parameters of movement (e.g. force and direction). In order to examine this prediction and build upon previous research we experimentally manipulated the difficulty of a golf putting task; we hypothesised that if the QE is related to motor programming then a more difficult task should be associated with longer QE durations. 33 golfers (M age= 21.16, SD= 3.98) with an average handicap of 6.5 (SD= 6.02) performed putts in 4 conditions of increasing difficulty. We manipulated the length of the golf putt (short-4ft, long-8ft) and the contact point of the putter head (large-1.7cm, small-0.5cm,) giving increasingly difficult putting conditions of short-large [1], short-small [2], long-large [3] and long-small [4]. We measured performance (radial error from hole in cm) and QE (in ms) for 10 putts in each condition. A repeated measures ANOVA was performed on the performance and QE data. The performance data suggest that we were successful in increasing the difficulty of the task (F (3,93) = 26.46. p = .000), with the best performance in condition [1] (8.57cm), followed by [2] (9.10cm) followed by [3] (16.11cm) and finally the worst performance was in condition [4] (23.40cm). The QE data suggest that, in keeping with our hypothesis, the QE was lengthened as task difficulty increased (F (3,87) = 11.91, p = .043). The QE was shortest in condition [1] (1787.85ms) and increased to condition [2] (1939.78ms) and condition [3] (2076.51ms), with the longest QE in condition [4] (2164.08ms). More detailed analysis of the QE reveal that it was the proportion of the QE that occurred before movement initiation (pre-QE) which increased with shot difficulty, rather than the proportion that occurred during the swing (Online-QE; see Vine et al., 2013). Results support the notion that more complex tasks are associated with a longer QE duration, specifically participants appear to spend longer fixating the target prior to movement. This likely reflects the time needed to process visual information gathered in a pre-performance routine, to inhibit external distraction, and to pre-programme the increasingly difficult parameters of the movement. Vickers, J.N. (1996). Visual control when aiming at a far target. Journal of Experimental Psychology: Human Perception and Performance, 22, 342-354. Vine, S.J. et al. (2013). Quiet eye and choking: Online control breaks down at the point of performance failure. Medicine and Science in Sports and Exercise, 45, 1988-1994.
Resumo:
Backspatter from wounds caused by contact shots against a biological target had before been shown to be propelled into firearms' barrels where they can persist and be retrieved from as relevant forensic evidence. Herein, that insight was applied to the investigation of a case of multiple familial homicide with a firearm. Samples of backspatter were collected from the firearm using DNA-free swabs. DNA was extracted from the swabs, and 16 STR systems were PCR-amplified to generate DNA profiles of all victims shot by the firearm. The quality of the resulting DNA profiles was sufficient to exclude the perpetrator as donor and to differentiate the three closely related victims thereby proving that all three victims had been shot by the same firearm from very close or contact distance. A key insight gained from this case was that not only a firearms' barrel inside but other inner surfaces may be charged with profilable DNA.
Resumo:
High-resolution chemical depth profiling measurements of copper films are presented. The 10 μm thick copper test samples were electrodeposited on a Si-supported Cu seed under galvanostatic conditions in the presence of particular plating additives (SPS, Imep, PEI, and PAG) used in the semiconductor industry for the on-chip metallization of interconnects. To probe the trend of these plating additives toward inclusion into the deposit upon growth, quantitative elemental mass spectrometric measurements at trace level concentration were conducted by using a sensitive miniature laser ablation ionization mass spectrometer (LIMS), originally designed and developed for in situ space exploration. An ultrashort pulsed laser system (τ ∼ 190 fs, λ = 775 nm) was used for ablation and ionization of sample material. We show that with our LIMS system, quantitative chemical mass spectrometric analysis with an ablation rate at the subnanometer level per single laser shot can be conducted. The measurement capabilities of our instrument, including the high vertical depth resolution coupled with high detection sensitivity of ∼10 ppb, high dynamic range ≥10(8), measurement accuracy and precision, is of considerable interest in various fields of application, where investigations with high lateral and vertical resolution of the chemical composition of solid materials are required, these include, e.g., wafers from semiconductor industry or studies on space weathered samples in space research.
Resumo:
Fragestellung/Einleitung: Die Eidgenössische Prüfung Humanmedizin (EP) wurde zwischenzeitlich dreimal erfolgreich durchgeführt. Daten zu Stärken, Schwächen und dem Weiterentwicklungsbedarf lagen bisher nur spärlich vor. Deshalb sollten diese anhand einer qualitativen Studie unter den involvierten Experten und bildungspolitischen Entscheidungsträgern erhoben werden. Methoden: Vier Fokus-Gruppen mit insgesamt 25 Teilnehmern wurden entsprechend internationaler Standards durchgeführt, um die Einschätzungen involvierter Experten und bildungspolitischer Entscheidungsträger bzgl. den erfahrenen Stärken, Einflüssen und dem Weiterentwicklungsbedarf der EP zu erhalten. Die Fokusgruppendiskussionen wurden wörtlich transkribiert und anhand von Inhaltsanalyse ausgewertet. Ergebnisse: Erfahrene Stärken waren v.a. die Kombination der beiden Prüfungs-Teile „Multiple Choice“ (MC) und „Clinical Skills“ (CS), die formatspezifischen Stärken der MC- und CS-Prüfung und die kollaborative Herangehensweise. Erfahrene Einflüsse der EP waren v.a. auf das studentische Lernverhalten, die Prüfer, den Lehrkörper, die Reform der Curricula, die Zusammenarbeit der Fakultäten und die erfahrene Wichtigkeit des Schweizer Lernzielkatalogs (SCLO). Bedarf zur Weiterentwicklung wurde v.a. in Folgendem gesehen: Dass Modifikationen nur angegangen werden, wenn diese wohlüberlegt und evidenzbasiert sind, in einer verbesserten Authentizität der CS-Prüfung, in weiteren Examensformaten, in einer verbesserten Kommunikationsstrategie, in der weiteren Revision des SCLO, in der Anerkennung der Limitationen eines „Single Shot Examens“ und im Aufbau einer Incentives-Struktur für die Kliniker, die aktiv die EP mitgestalten. Diskussion/Schlussfolgerung: Insgesamt wird die EP als geeignet für ihre Aufgaben angesehen. Diese Prüfung hat Einflüsse auf die Medizinstudierendenausbildung in der Schweiz auch über die direkten summativen Prüfungsaspekte hinaus. Es wurde ein Bedarf zur Weiterentwicklung gesehen, jedoch sollten die Veränderungen wohl begründet sein.
Resumo:
Trichinellosis is one of the most important foodborne parasitic zoonoses, caused by nematodes of the genus Trichinella. Pigs and other domestic and wild animals, including red foxes (Vulpes vulpes), are sources of Trichinella infection for human beings. Trichinella britovi is the major agent of infection in sylvatic animals and the most important species circulating in the European wildlife. The present study aimed at assessing Trichinella spp. infection in red foxes from the North of Portugal. Forty-seven carcasses of wild red foxes shot during the official hunting season or killed in road accidents were obtained between November 2008 and March 2010. In order to identify the presence of Trichinella spp. larvae in red foxes, an individual artificial digestion was performed using approximately 30g of muscle samples. Larvae of Trichinella spp. were detected in one (2.1%) out of the 47 assessed foxes. After a multiplex polymerase chain reaction analysis, T. britovi was molecularly identified as the infecting species. The recognition of T. britovi in a red fox confirms that a sylvatic cycle is present in the North of Portugal and that the local prevalence of Trichinella infection in wildlife must not be ignored due to its underlying zoonotic risks.
Resumo:
In contact shots, the muzzle imprint is an informative finding associated with the entrance wound. It typically mirrors the constructional components being in line with the muzzle or just behind. Under special conditions, other patterned skin marks located near a gunshot entrance wound may give the impression to be part of the muzzle imprint. A potential mechanism causing a patterned pressure abrasion in close proximity to the bullet entrance site is demonstrated on the basis of a suicidal shot to the temple. The skin lesion in question appeared as a ring-shaped excoriation with a diameter corresponding to that of the cartridge case. Two hypotheses concerning the causative mechanism were investigated by test shots: - After being ejected, the cartridge case ricocheted inside a confined space (car cabin in the particular case) and secondarily hit the skin near the gunshot entrance wound. - The ejection of the cartridge case failed so that the case became stuck in the ejection port and its mouth contacted the skin when the body collapsed after being hit.